Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 CrAccepted-AOC | ₹7.1 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹7.1 Cr+₹4.9 L (0.69%)Rejected-Finance | ₹7.1 Cr+₹4.9 L (0.69%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹7.2 Cr+₹11.1 L (1.56%)Rejected-Finance | ₹7.2 Cr+₹11.1 L (1.56%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹7.2 Cr+₹14.6 L (2.05%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹7.2 Cr+₹14.6 L (2.05%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹7.4 Cr+₹33.9 L (4.78%)Rejected-Finance | ₹7.4 Cr+₹33.9 L (4.78%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹7.3 Cr
EMD Value
₹6.9 L
Closing Date
30 Nov 2023, 6:00 pmClosed
Chief Engineer Lucknow Zone
Chief Engineer Lucknow Zone, 17, Carriappa Road, Lucknow - 226002
PROVN OF SINGLE ACCN (OTM) FOR 160 ADDL TRANSIENTS AT FATEHGARH CANTT
2023_MES_616431_2
CELZ/FAT/T-07 OF 2022-23
Open Tender
Construction Works
Lump-sum
540 days
Fatheharh
As per NIT
8 documents required · 8 mandatory
₹3,000
AGE (I) Fatehgarh
₹6.9 L
Yes
8 Jan 2024
4 Nov 2023
2 Dec 2023
4 Nov 2023
30 Nov 2023
18 Nov 2023
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V ( Path & Hardstanding)
Total amount of Sch 'A' Part VI (Area Drainage)
Total amount of Sch 'A' Part VII (Sewage Disposal)
Total amount of Sch 'A' Part VIII (External Water Supply )
Total amount of Sch 'A' Part IX (External Electrification)
Total amount of Sch 'A' Part X (Hot Water Supply)
Total amount of Sch 'A' Part XI (Rain Water Harvesting )
Sch 'A' Part - XII (Miscellaneous Items for B/R & E/M Works) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
S&F two way angle valve, cast copper alloy, chromium plated fancy type high pressure with crutch or butterfly handles screwed both ends for iron pipe or for brass ferrule 15 mm bore complete all as specified and directed.
S&F chromium plated, fancy type wall mixer 3 in 1 for mixing hot & cold water screwed both ends for iron pipe and fixed, complete all as specified and directed.
INTERNAL ELECTRIFICATION M&L for Point wiring complete for One light/Fan/Bell point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 8 points only.
M&L for Point wiring complete for One light point controlled by two way switches with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 8 points only.
M&L for point wiring for 5 Amp including socket point complete with PVC insulated and unsheathed, FRLSH cable 2.5 sqmm (nominal area), ISI marked, multi-stranded copper conductor single core including ISI marked 20mm dia medium grade PVC conduit concealed in wall and PVC conduit in roof/floor slab, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories and all as specified. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 4 points only.
M&L for point wiring complete with PVC insulated and unsheathed, FRLSH cable 2.5 sqmm (nominal area), ISI marked, multi-stranded copper conductor single core including ISI marked 20mm dia medium grade PVC conduit concealed in wall and PVC conduit in roof/floor slab, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories and all as specified. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max one points only.
Supply and fixing Switch flush piano type 5/6 Amps single pole two way complete all as specified and dierected.
Supply and fixing Ceiling fan 1200 mm sweep BLDC fan five star rating single phase 230V AC, ISI marked with minimum air dilivery 210 CFM alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long for connection complete all as specified and directed.
Supply and fixing Exhaust Fan heavy duty mettalic body, resistant to colour change 300 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed.
Supply and fixing LED light fitting,1X20/22 Watt, 220 volts, decrorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified .and directed.
M&L for Submain wiring with two single core 4 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 20 mm dia concealed in wall surface / ceiling for sub main connection including 4 sqmm PVC insulated multistranded unsheathed FRLSH copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Submain wiring with four single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit medium grade not less than 25 mm dia concealed in wall surface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor FRLSH used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Four single core 6 sqmm copper conductor, one run PVC conduit and two run of 6 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
S&F LED lights fitting mirror type with high out put diffuser 2 feet, 10/12 Walt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper condutor cable of suitable size from ceiling rose complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth strip 25mm x 4mm as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR 2009 part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Earth strip beyond 7.5m shall be measured and paid separately.
S&F LED light fitting 1x9W/ 1x10W bulk head luminaires including LED light driver lolder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing 25 watt ,5700K LED security light made out of pressure die cast aluminium housing with toughned glass , IP66 protection and impact resistance IK07 ,mounted on top of the pole with cap type bracket having lenght not less than 0.6 meter fixed with suitable fasteners having extended arm length not less than 1.5 meter and dia not more than 43 mm and angle between pole and extended arm should be 100 to 105 degrees including fabrication work for fixing Building security light . including PVC insulated three core 23/0.0076 copper cable and includinding suitable size of pvc flexible conduit from celling rose to building security light fittings complete all as specified and directed.
S&F VTPN DB 4 way double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete.including MCCB FP 160 Amp, 16 KA capacity all as specified and as directed.
S&F TPN DB 4 way double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with enclosure blank plates for unused way suitable for 4 way all as specified and directed
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 12 way ISI marked all as specified and directed
S&F 415V 10 KA 'B' curve MCB TPN 40 to 63 Amp and current carrying capacity in the DB complete with connection testing and commissioning all as specified and directed
Supply and Fixing 240V,10KA'B' curve MCB SPN current carrying capacity 40 Amp,in the MCB DB complete with connection testing and commissioning. 6-40 amps rating 'B' Series,10 KA 240 Volts,AC 50 Hz ,ISI marked all as specified and directed .
Supply and Fixing 240V,10KA'B' curve MCB SP, current carrying capacity 6-32 Amp,in the MCB DB complete with connection testing and commissioning. 6-32 amp rating 'B' Series,10 KA 240 Volts,AC 50 Hz ,ISI marked all as specified and directed .
Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Earthing wire beyond 7.5m shall be measured and paid separately.
SEWAGE DISPOSAL M&L for soakage well of size (3 M dia X 4.5 M effective depth) with and including necessory excavation and eath work complete all as specified and shown on drawing No TD/237 sheet 1/1 and as directed.
M&L for RCC Septic tank for 100 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as specified and shown on drawings TD/217 sheet 1/2 to 2/2 and as directed.
EXTERNAL WATER SUPPLY Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Cutting existing CI/GI pipe line 150 mm dia for insertion of tee of size 150 x 150 x 80 mm for branch connection including excavation and earth work complete all as specified and directed.
Supply and Fix sluice valves, 80 mm dia class PN 1.6 with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, laying in trenches/pipe/ on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS: 7098(Pt-II) with stranded aluminium conductor of size 185 sq mm 3.5 core and complete all as specified .
Supply, laying in trenches/pipe/ on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS: 7098(Pt-II) with stranded aluminium conductor of size 70 sq mm 3.5 core and complete all as specified .
Supply, laying in trenches/pipe/ on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS: 7098(Pt-II) with stranded aluminium conductor of size 10 sq mm 4 core and complete all as specified .
Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31, 9.00 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/6 sqmm 2 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and bolts with suitable busbar all as spcd and directed.
Supply, installation, testing and commissioning in replacement of out door type LT Feeder pillar box size 0.90 m x 0.75 m x 0.45 m in depth made out of 3.15mm thick CRCA sheet ( CPRI type tested) and MS structural section of 50 x50 x 6 mm comprising of copper bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted on suitable bus bar insulators, 200 Amps rating suitably drilled and tapped for bolts with openable two part front and rear shutter, hinged front and rear panels and locking arrangement, bottom plate provided with the requires numbers of cable entries / opening including cable glands and cable lugs with heat strinkable PVC sleeving having RYB-B colour code , powder coated painting complete embedded in PCC 1:3:6 type C-2 ( using 40 mm graded aggregate ) n. exc. 0.45 cum and provision of following accessories complete all as specified and as directed ( Note :-MCCB will be measured and paid separately.)
S & F MCCB of 160 Amps, 4 pole, 415 volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides complete all as specified and directed.
HOT WATER SUPPLY Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
RAIN WATER HARVESTING M&L loose filling with pea gravel of size 1/18" to 3/18" to as in filter bed complete all as specified
Drilling of hole in any strata by mechnical percussion or rotary ring method below GL including electric loging through any type of strata soil/rock disposal of soil within 10 mtr keeping space for pea gravel packing and including lowering and extraction of perforated PVC pipes of dia 200mm complete all as specified.
S&F Perforated PVC pipe 200mm dia in any length and fixed in any position including inverted earthen pots with holes on top complete all as specified.
BHARAT ASSOCIATES PVT LTD
VEE SONS BUILDERS PVT LTD
YAUK ENGINEERS
M/s Ram Singh Agarwal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .