Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAdmitted-Finance | ₹2.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.8 Cr+₹14.7 L (5.58%)Admitted-Finance | ₹2.8 Cr+₹14.7 L (5.58%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | LUCKY TRADERS CONTRACTORS AND ENGINEERS L2 | KHURSHEED AHMAD KUCHAY L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work in bulk excavation by mechanical means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge
All kinds of soil: | 473.46 | Cum | 180 ₹85,222.8 Lowest | 1,200 ₹5,68,152 |
| 2.00 | Extra for every additional lift of 1.5m or part thereof in Excavation/Banking excavated or staxcked material
All kinds of soils | 98.56 | Cum | 35 ₹3,449.6 Lowest | 400 ₹39,424 |
| 3.00 | Clearance of site of all the materials of existing/ damaged uprooted foundations of the towers including all required excavation of earth, this is also inclusive of removing of all “concrete work in the form stubs/tower legs, base rafts with included earth work by mechanical means/dewatering” what so ever gets involved and preparing the site for piling. The item is inclusive of disposal of the dismantled/excavated concrete and the close timbering operation if required. The material disposal is to be done in a way as not to invite any controversy.
Any serviceable dismantled material is to be returned to the divisional stores as per the directions of the engineer in charge. However the back filling charges are included seperately | 8 | I job/tower | 10,000 ₹80,000 Lowest | 15,000 ₹1,20,000 |
| 4.00 | Boring, providing and installing bored cast in situ reinforced cement concrete pile of specified grade, concrete mix diameter and length below the pile cap in M-35 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with casing and / or bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete including removal of excavated earth with lifts and leads (length of pile for payment shall be measured from top of shoe to the bottom of pile cap) 600 mm dia pile of varying length(from 8-15m) by percussion drilling using(DMC) or bailer and chisel technique by tripod and mechanical winch machine all complete. | 930 | RM | 7,950 ₹73,93,500 | 5,100 ₹47,43,000 Lowest |
| 5.00 | Vertical load testing of piles in accordance with SI-2911(PART-IV) including installation of loading platform By Kent ledge/anchor pile method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. Complete as per specifications and the direction of engineer in charge.
Routine test (test load 1.5 times the safe capacity)
Vertical load testing of piles | 3 | Per test | 50,000 ₹1,50,000 Lowest | 90,000 ₹2,70,000 |
| 6.00 | Dismantling of RCC work manually/by mechanical means including staking of steel bars and disposal of unserviceable items within 50 mtrs lead as per direction of engineer in charge for breaking of pile heads | 22.6 | Cum | 500 ₹11,300 Lowest | 1,500 ₹33,900 |
| 7.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers (each layer should not exceed 15cm)with intermediate layer of compacted earth (soil density 98%) consolidating each deposited layer by ramming and watering, as per the direction of engineer in charge | 897.4 | Cum | 50 ₹44,870 Lowest | 200 ₹1,79,480 |
| 8.00 | Supplying and filling in trenches with fine sand under floors including, watering, ramming, consolidating and dressing complete Supply of sand for meeting the requirement as in item no. 7, 25% only | 240 | Cum | 1,000 ₹2,40,000 Lowest | 1,500 ₹3,60,000 |
| 9.00 | Providing and laying stone soling layer under pile caps as per direction of engineer in charge | 53.3 | Cum | 1,200 ₹63,960 | 1,000 ₹53,300 Lowest |
| 10.00 | Providing and laying in position specified grade of cement concrete excluding the cost of centering, shuttering finishing and reinforcement M-10 | 27.17 | Cum | 4,200 ₹1,14,114 Lowest | 5,200 ₹1,41,284 |
Tender Value
₹2.5 Cr
EMD Value
₹4.9 L
Closing Date
21 May 2026, 2:00 pmClosed
Executive Engineer TLMD VII
Office of Executive Engineer TLMD VII Bemina Srinagar
As per SBD
2026_PDD_307321_3
TLMD-7/TS/01 of 2026-27
Open Tender
Civil Works - Others
Turn-key
83 days
TLMD-VII
As per SBD
9 documents required · 9 mandatory
₹2,500
Executive Engineer TLMD-VII Sgr. 0367010200000182
₹4.9 L
Yes
18 Jul 2026
17 Apr 2026
22 May 2026
17 Apr 2026
21 May 2026
17 Apr 2026
17 Apr 2026 - 18 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work in bulk excavation by mechanical means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge
All kinds of soil: | 473.46 | Cum | - | - |
| 2 | Extra for every additional lift of 1.5m or part thereof in Excavation/Banking excavated or staxcked material
All kinds of soils | 98.56 | Cum | - | - |
| 3 | Clearance of site of all the materials of existing/ damaged uprooted foundations of the towers including all required excavation of earth, this is also inclusive of removing of all “concrete work in the form stubs/tower legs, base rafts with included earth work by mechanical means/dewatering” what so ever gets involved and preparing the site for piling. The item is inclusive of disposal of the dismantled/excavated concrete and the close timbering operation if required. The material disposal is to be done in a way as not to invite any controversy.
Any serviceable dismantled material is to be returned to the divisional stores as per the directions of the engineer in charge. However the back filling charges are included seperately | 8 | I job/tower | - | - |
| 4 | Boring, providing and installing bored cast in situ reinforced cement concrete pile of specified grade, concrete mix diameter and length below the pile cap in M-35 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with casing and / or bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete including removal of excavated earth with lifts and leads (length of pile for payment shall be measured from top of shoe to the bottom of pile cap) 600 mm dia pile of varying length(from 8-15m) by percussion drilling using(DMC) or bailer and chisel technique by tripod and mechanical winch machine all complete. | 930 | RM | - | - |
| 5 | Vertical load testing of piles in accordance with SI-2911(PART-IV) including installation of loading platform By Kent ledge/anchor pile method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. Complete as per specifications and the direction of engineer in charge.
Routine test (test load 1.5 times the safe capacity)
Vertical load testing of piles | 3 | Per test | - | - |
| 6 | Dismantling of RCC work manually/by mechanical means including staking of steel bars and disposal of unserviceable items within 50 mtrs lead as per direction of engineer in charge for breaking of pile heads | 22.6 | Cum | - | - |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers (each layer should not exceed 15cm)with intermediate layer of compacted earth (soil density 98%) consolidating each deposited layer by ramming and watering, as per the direction of engineer in charge | 897.4 | Cum | - | - |
| 8 | Supplying and filling in trenches with fine sand under floors including, watering, ramming, consolidating and dressing complete Supply of sand for meeting the requirement as in item no. 7, 25% only | 240 | Cum | - | - |
| 9 | Providing and laying stone soling layer under pile caps as per direction of engineer in charge | 53.3 | Cum | - | - |
| 10 | Providing and laying in position specified grade of cement concrete excluding the cost of centering, shuttering finishing and reinforcement M-10 | 27.17 | Cum | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
SBD01.pdf
Tender Documents • 3.16 MB
BOQ_998781.xls
BOQ • 0.32 MB
Ext0301.pdf
PDF • 2.37 MB
Ext0201.pdf
PDF • 2.39 MB
Ext0101.pdf
PDF • 2.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .