Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.2 L+₹1.2 L (3.09%)Rejected-Finance A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹40.6 L+₹1.7 L (4.28%)Rejected-Finance A 46 ARYA NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹43.1 L+₹4.1 L (10.5%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹43.3 L+₹4.4 L (11.2%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹87,000
Closing Date
17 Nov 2022, 6:00 pmClosed
GE Alwar
GE Alwar
SPECIAL REPAIR TO BLDG NO 715, 716, 717 AND 718 (COOK HOUSE) AND PROVN OF SANCTIONED WORK UNDER AGE B/R-II AT ITARANA, ALWAR
2022_MES_555217_2
8103/E8
Open Tender
Civil Works
Item Rate
180 days
Alwar
As per NIT
3 documents required · 3 mandatory
₹500
Yes
GE Alwar
₹87,000
Yes
7 Jan 2023
1 Nov 2022
19 Nov 2022
1 Nov 2022
17 Nov 2022
4 Nov 2022
1 Nov 2022 - 3 Nov 2022
Amount
Taking down cement or cement lime plaster, of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Demolition cement concrete (unreinforcement) in ground floor and paving n exc 15 cm thickness (below or above ground level) & removal complete all rubbish materials complete all as specified and directed.
Demolition of cement concrete (reinforced) in landing slab, chullah hoods, manhole covers, roofs, floors, beams, stair case, landing, chajja and similar suspended work complete all as specified & directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars & precast concrete masonry etc complete all as specified & directed.
Demolition of existing lime concrete/PCC padding, roof treatment of any thickness laid over RCC roof/Chajjas etc removing complete layer of bitumen under cocnrete/PCC padding, cleaning and washing of roof with water to remove dust etc as preparation to receive treatment all as directed and specified.
Taking down chowkats or frames with shutters (without taking off shutters frome the frames) n exc 1.5 but each complete all as specified & directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 but n exc 4 sqm each complete all as specified & directed.
Taking down shutters of any description exc 2 sqm each complete all as specified & directed.
Taking down shutters of any description exc 1 sqm & n exc 2 sqm each complete all as specified & directed.
Taking down of shutter and refixing exc 1 sqm and n exc 2 sqm each complete all as specified & directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar all as specified & directed.
Cutting holes into stone wall built in cement mortar or cement lime mortar for inserting hold fast and making good dismental portion in CM (1:3) or cement concrete (1:2:4) type B-1 exc half brick but n exc one brick as required complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-1 (using 12.5mm graded aggregate) as in levelling coarse of floors complete all as specified & directed.
M&L for 75 mm thick PCC 1:4:8 Type D-2 (using 40 mm graded stone agg ) as in sub base complete all as specified & directed..
M&L for providing 50mm thick cement concrete type B-0, 1:2:4 (using 12.5 graded stone aggregate) as in padding on roof. Roof padding shall be laid in two layers of 25mm thick each incl chiken wire mesh shall be placed between two layes of PCC padding. The surface of padding shall be finished even and smooth without using extra cement. False groove shall be made on top of padding complete all as specified & directed. Note : The quoted rates are deemed to be included of chiken wire mesh.
M&L cement cocnrete type C-1, 1:3:6 (using 20mm graded stone aggregate) as in plinth protection 75mm thick and surface to be finished even and smooth without using extra cement. Plinth protection shall be laid in pannels n.exc 1.50 mtr 6mm wide and 10mm deep joints shall be made between wall & pinth protection and between panels. Joint shall be filled with bitumen mastic and sand in proporation 1:3 (one part of bitumen and three part of sand) complete all as specified & directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate as in cills, coping steps, tank staging, sesmic and other similar courses, lacing courses parapet and railing upto 60cm ht kneeler kerb and alike including weathering, slightly rounded or chemfered angle and throating as directed.
M&L reinforced cement concrete (nominal mix) type B-1 1:2:4 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed.
M&L plain cement concrete 1:2:4 type B0 in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified & directed.
M&L 15mm thick cement plaster on external surface in CM 1:4 mixed with WPC 3% by weight of cement including finishing fair & even all as specified & directed.
Supply only water proofing compound as per IS-2645 complete all as specified & directed.
M&L for roughcast finish plaster on exterior walls in two layers, under layer 10mm cement plaster 1:3 (1 cement: 3 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer applying roughcast mixer consisting of crushed stone or fine gravel agg of size 6 to 10mm depending on texturer reqd mixed with coarse sand and cement in the ratio of 1:1:1 be applied and finish even complete all as specified & directed.
M&L for 15mm thick cement plaster in CM 1:6 on other than fair faces of brick work or concrete surface finished even and smooth without using extra cement complete all as specified & directed.
M&L for 10mm thick screed bed on fair faces of concrete/brick surfaces in CM 1:4 with water proofing compound @ 3 % of wt of cement finished even and smooth in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane finished complete all as specified (Note : Polymeric membrane and WPC shall be meausred and paid seperately here-in-after).
M&L for rendering 5 mm thick in CM (1:3) as in ceiling and finish the surface even and smooth without using extra cement complete all as specified & directed.
M&L for taking down and removal of loose / disintegrated old concrete / plaster and applying 3mm thick bonding coat of modified styrene butadiene emulsion (SBR Bonding agent i.e. Nitobond SBR 45) in proportion 1 (Nitobond SBR 45) : 1(water) : 3 (OPC) by volume with the brushes etc to bind New Cement plaster/ polymer Modified plaster/ concrete/ screed concrete with old surface etc complete.
M&L for applying 15mm thick plaster with polymer modified mortar fortified with SBR (Nitobond SBR 45) in proportion 1:3 by weight 5 litres Nit bond SBR 45 to added to 50 Kg cement with 13 litre water addition, finished surface to match with existing adjoining surface of ceiling, beams and alike complete.
M&L and applying two or more coats of 2 component zinc based epoxy rust preventer (Nitozinc Primer-M) on corroded reinforcement after cleaning and removing the rust from corroded reinforcement with the help of wire brush and treating it with rust remover (Reebaklens RR) including thoroughly cleaning washing air blowing brushing etc complete all as specified & directed. Note : Qty of zinc based epoxy rust prevent or only shall be taken into account for payment purpose on the basis of actual consumption.
M&L for glazed coloured ceramic tiles in vertical surface 300mm x 450mm x 7mm thick laid over and including 10 mm rendering in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed.
M&L for non skid ceramic tiles (coloured) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. laid over and including 15 mm screed bed or bedding layer in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile Complete all as specified and directed.
M&L for non skid ceramic tiles (coloured) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc laid over 15mm screed bed or bedding layer in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed.
M&L for non skid ceramic tiles (coloured) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting or vertical surface etc.laid over 10 mm screed bed or bedding layer in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile Complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 20 to 22mm thick as in floor,cooking platform, treads etc .laid over and including 20 mm screed bed or bedding layer in CM 1:6 set and jointed in neat cement slurry and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing upto mirror finish by machine complete all as specified and directed by Engr-in-charge
M&L for machine cut Kota stone 16-18 mm thick as in riser of steps, skirting, dado and pillar set over 10 mm rendering in CM 1:3 and jointed with grey cement slurry mixed with pigments to match the shade including rubbing and polishing complete all as specified by Engr-in-Charge.
M&L for 16-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over 15 mm screed bed or bedding layer in CM 1:3 complete all as specified and directed.
M&L for machine cut 20 to 25 mm thick kota stone in single piece as in shelves and similar works laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing including ball nosing of exposed edges and including dismantling old stone slabs complete all as specified and directed.
S&F factory made 35mm thick flush shutter, solid core construction, with block board core and plywood face panels, both face covered with deco rative face veneer with lipping/frame to match commercial type on both sides all as specified and directed.
M&L for factory made 2nd class glazed and skelton door shutter made out of stiles & rails of 35mm thick 2nd class hard wood, klin seasoned and chemically pressure treated & open reabted and prepared to receive glass/gauge etc (without sash bars), edges of framing plain,chamfered of rounded, fitted with and mitred beads for securing glass etc compelte, the SIze of members of shutter shall be as per IS-1003. The shutter shall be fitted to the chowkhats as directed by Engr-in-Charge.
S&F 35mm thick 2nd class hard wood factory made plain, framed,panelled shutter (two panel) with lock rail & panel of 9mm BWP commercial ply seasoned & chemically pressure treated/12mm veneered, particle board with commercial veneering on both faces. The size of rail & steel as per IS : 1003 (Part I) kiln seasoned & chemically pressure treated.
S&F factory made solid PVC moulded door shutters 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded PVC wood grain sheet on the front face & 2mm plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification & drawing.
S&F in repairs factory made steel window (box type) with side hung shutters including box type hinges, steel handles and peg stay complete with glazing bars dovetailed or welded incl fixing of lugs in PCC 1:2:4 type B1 using 20mm graded stone aggregate and making good walls & cills to match the existing complete all as specified and directed and shown in drg No TD/2013/01 sheet 1/3 to 3/3.
S&F in repair factory made steel window (box type) with side hung shutters including box type hinges, steel handles and peg stay complete without glazing bars dovetailed or welded incl fixing of lugs in PCC 1:2:4 type B1 using 20mm graded stone aggregate and making good walls & cills to match the existing complete all as specified and directed and shown in drg No TD/2013/01 sheet 1/3 to 3/3.
S&F in repair factory made steel ventilator (box type) with top hung shutter including hinges, steel peg stay, handle and peg stay complete with glazing bars dovetailed or welded incl fixing of lugs in PCC 1:2:4 type B1 using 20mm graded stone aggregate and making good walls & cills to match the existing complete all as specified and shown in drg No TD/2013/01 sheet 1/3 to 3/3.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples to wooden frames with beading complete all as specified & directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each pane complete all as specified and directed.
S&F 4mm thick sheet glass figured and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed.
S&F in repair vitreous china squatting pan of orrisa pattern size 580mm x 440mm white with integral foot rest (excluding flushing cistern and flush pipe complete incluidng provision of lime concrete bedding complete all as specified and directed.
S&F in repair PVC flushing cistern low level 10 ltr cap with inlet ball valve float and handle syphonic action type incl brackets and flush pipe of polythene of low or high density ISI marked complete all as specified and directed.
S&F in repair 15mm dia bib tap cast coper alloy chromium plated fancy type crutch or butter fly handle screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15mm dia angle valve of copper alloy fancy type chromium plated screwed down high pressure with crutch or butter fly handle screwed on both ends for iron pipe or for union.
S&F in repair swivel shower rose(fancy type) chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed.
S&F in repair 15mm dia concealed stop valve of copper alloy fancy type chromium plated with long shank and cup (concealed type) screwed down high pressure with crutch or butter fly handle screwed on both ends for iron pipe or for union complete all as specified & directed.
S&F WHB ovel type of size 580mm x 450mm incl pillar tap, brackets incl waste pipe cutting pinning in ends of brackets complete fixed in granite cutting top of granite as shape of WHB complete all as specified and directed.
S&F in repair 32 mm dia PVC flexible waste pipe for WHB/Sink 750 mm long with PVC coupling all as directed.
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long fixed on wall with PVC rawl & cadmium plated brass screws complete all as specified & directed
Taking up or down steel tubing and connections including cleaning for refixing or removal to store 20mm bore pipe complete all as specified & directed.
Refixing old steel tubing and connection in new or old position (walls, ceiling, floor etc) bore of pipe in 20mm dia complete all as specified & directed.
S&F tubes medium grade 'galvanised' with and including all fitting and fixed bore of 20 mm dia complete to walls and ceiling or laid in floors of 20 mm bore complete all as specified & directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store 15mm bore pipe complete all as specified & directed.
Refixing old steel tubing and connection in new or old position (walls, ceiling, floor etc) bore of pipe in 15mm dia complete all as specified & directed.
S&F tubes medium grade 'galvanised' with and including all fitting and fixed bore of 15mm dia complete to walls and ceiling or laid in floors of 15mm bore complete all as specified & directed.
S&F in repair sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or incluidng fixing contilever brackets and connecting union to pipe over all size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified & directed.
S&F in repair 20mm gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed.
Dismantling of water tanks of capacity exc 500 but n exc 1000 ltrs & removing to stores complete all as specified & directed.
S&F 1000 liters capacity rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top)vhoilsted and fixed in position including 02 Nos tank nipples inlet and outlet all as specified in SSR Part-I complete all as specified & directed.
S&F in repair ball valve brass high pressure with polythene float and fly nut screwed on iron pipe and fixed 20mm bore of pipe complete all as specified & directed.
S&F PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified & directed.
S&F in repair brass chromium plated tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified & directed.
S&F in repair grating doom 125 mm dia with waste hole of PTMT (Min wt 40 gms) all as specified and directed.
S&F in repair brass chromium plated soap dish complete all as specified.
S&F in repair brass CP mixer for sink with swan neck for mixing hot & cold water screwed down for iron pipe complete all as specified & directed.
S&F in repairs 15 mm bore fancy type long body bib tap, half turn, with wall flange, cast copper alloy with capstan heads, chromium plated, screwed for iron pipe or for brass ferrule, complete all as specified & as directed.
S&F UPVC (SWR) pipes of 75 mm nominal diameter (Type B with wall thickness 3.20 to 3.8 mm) single socketed in any length with rubber ring joints laid in trenches or in floors of 75mm pipe incl taking out old u/s PVC/CI pipe with fittings complete all as specified & directed.
S&F UPVC (SWR) pipes of 110 mm nominal diameter (Type B with wall thickness 3.20 to 3.8 mm) single socketed in any length with rubber ring joints laid in trenches or in floors of 110mm pipe incl taking out old u/s PVC/CI pipe with fittings complete all as specified & directed.
S&F UPVC (SWR) pipes of 75 mm bore single socketed in any length fixed to wall i/c taking out old u/s PVC/CI pipe with fittings complete all as specified & directed.
S&F UPVC (SWR) pipes of 110 mm bore single socketed in any length fixed to wall i/c taking out old u/s PVC/CI pipe with fittings complete all as specified & directed.
S&F UPVC (SWR) floor trap, plain with grating including joining with solvent cement 75 mm dia complete all as specified & directed.
S&F UPVC (SWR) bend 75mm bore of any radius complete all as specified & directed.
S&F UPVC (SWR) bend 75mm bore of any radius with access door complete all as specified & directed.
S&F UPVC (SWR) bend 110 mm bore of any radius complete all as specified & directed.
S&F UPVC (SWR) bend 110 mm bore of any radius with access door complete all as specified & directed.
S&F UPVC (SWR) vent cowl 110 mm complete all as specified & directed.
S&F in repair 110 mm stack clamp out of 50mmx 5 mm flat iron and 16 mm dia round iron stays incl bolts and nuts and securing ends of stays to walls or roof etc, complete all as specified and directed.
S&F for 75mm thick steel fibre reinforced (SFRC) man hole cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS standard, minimum load bearing capacity 5 ton/sqm, in square, rectangular or circular shape complete all as specified & as directed.
S&F in repairs salt glazed stone ware gully trap square or round mouthed type 'P' of size 150mm x 150mm with CI grating, setting & jointing with cement with grouting surrounding gully trap with PCC 1:3:6, type C1 block 30x30x45cm together with necessary form work, excavation & earth work in soft/loose soil, complete all as specified and as directed.
S&F in repair hasp and staple, 75mm size, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate & fixed with screws, complete all as specified.
S&F 125mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified & directed.
S&F 150mm long (size) aluminium anodised, barrel tower bolt of extruded section and fixed, complete all as specified.
S&F mild steel butt hinges medium weight colod rolled of size 100mm, ISI marked complete all as specified and directed.
S&F exctruted aluminum alloy with galavanisied mild steel hing pin Butt hinges 100mm long complete all as specified & directed.
S&F aluminum alloy, anodised, sliding door bolt with hasp and staples type, 300mm long and fixing clip of sheet cast or extruded sections and fixing bolts and sliding bolts of extructed section or cast aluminum alloy and fixed all as specified.
S&F aluminium anodised, barrel tower bolt 200mm long of extructed section and fixed complete.
S&F extructed aluminium alloy handle 150mm, fabricated type, anodised all as specified.
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed.
S&F 140mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, with vulcanised rubber piece fixed in floor as directed.
M&L for pressed steel cupboard shutter godraj pattern 1mm thick including pressed steel frame of 1.25 mm thick sheet, 12mm dia MS rod for locking, two Nos chromium plated handle and one mortise pattern lock inclu two coats of spary painting over a coat of shop primer complete all as shown on drg No TD/2004/29 sheet no 1/3 to 3/3.
S&F in repairs stainless steel drapery rod of 20 mm inner dia (in length as directed) of approved colour with & including decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beams including PVC curtain rings of matching colour @10 cm c/c all as specified and directed.
M&L for 50mm thick sand stone slab in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc not exc 2m in length, punched dressed on face and along exposed edges, self faced on the other SIde and set and pointed in cement mortar 1:4 complete.
M&L for TMT bars 10mm dia and over cut to length to shape required including cranking, bending spirally or hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9 mm dia all as specified.
All as per item No 102.00 above but 6mm to 8mm dia TMT bars.
All as per item No 102.00 above but 5mm dia and over upto & including 10mm dia in stirrups, spaces and binders
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in 1:4 as in half brick thick wall complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 mean radius, built in CM 1:6 complete all as specified & directed.
Dismantling boarding any description (board/plywood) fixed in any position with nails, complete all as specified.
S&F frame work such as grills, grating etc,with ends of bars shouldered &/or riveted or forged into spikes,framed guard bars, barred iron door ladder,frame balusters, walk ways, railing,frame work or water tanks & SImilar work conforming to Fe-290 Gde E-165 complete all as specified & directed.
M&L flat iron as in hold fast welded to angle iron door/window frames as directed.
M&L for framed work as in doors or gates angle or other covering door etc to be prepared for handing or sliding with including either hooks and hinges or steel hanging dor fittings (excluSIve of steel or othr covering, running rails and guides) and hanging also fastening and fixing complete conforming to FE-290 Gde E-165 complete.
M&L for pre polished vibration moulded precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment of any colour over and including 25 to 30mm thick sand cushioning layer complete.
M&L water proofing treatement to RCC roof slabincluding parapet comprising of following course of treatement/specified from bottom to top (a) Applying Bituminous primer @ 0.40 Ltr per sqm over plastered surfaces of roof including parapet surfaces. NOTE : Bituminous primer shall be 'TANK MASTIC' manufactured by M/S STP Ltd or 'EMW FLATE' M/S Texas India Ltd (b) Over the priming coat applying hot bitumenous 85/25 @ 1.20kg/sqm (c) laying one layer APP based polymeric membrane of approved manufacturer, 3 mm thick weight not less 3.0 Kgs/Sqm of make super thermolay manufactured by STP ltd or 'Hyper plus'(polyster) manufactured by M/S IWL Ltd or 'Shaliplas' manufctured by M/S Capital Steel and chemical Pvt Ltd as approved by GE reinforced with non woven polyester fabric torching overlap with a propane or a butane gas toarch with a overlap of 75mm at the sides and 100mm at the ends and sealing with bitumen coat membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flushing.
M&L for Preparation of old painted surfaces of steel and iron surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified..
S&F for preparation of new steel surface/old untreated of any description over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of newly wooden surfaces/old untreated of any description over 10 cm width or girth and applying two coats of synthetic enamel paint (of approved shade) over a coat of pink primer all as specified and directed.
M&L for preparation of old wooden surface of any description over 10 cm width or girth and applying one coats of synthetic enamel paint (of approved shade) all as specified and directed.
M&L for preparing newly plastered surfaces & applying two coats of oil emulsion distempering(OBD) over and including a coat of cement wall care putty 2 mm thick over a coat of primer on walls complete all as specified and directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efforsecent salt, trading oil grees spots etc using grinding machine on wall surfaces and preparation of old plastered wall surfaces and applying two coats of oil emulsion distemper (OBD) of approved shed/tint over and including a coat of white wall care putty 2mm thick complete over a coat of primer.
M&L for preparing newly plastered surfaces & applying three coat of white wash on ceiling complete all as specified & directed.
M&L for preparation of old surrfaces and applying two coats of white wash on ceiling complete all as specified & directed.
M&L for preparation of old surfaces of wall and applying two coats of white wash on wall complete all as specified & directed.
M&L for preparing newly plastered surfaces & applying three coats of white wash on walls complete all as specified & directed.
M&L for preparation of previously treated surfaces/old surface of wall and applying one coat cement base paint on old surface of wall complete all as specified & directed.
M&L for preparation of newly plastered surface of wall & applying two coats of cement base paint over a coat of primer complete as specified and directed.
M&L for machine cut 16 to 20 mm thick green marble stone slab in single piece as in shelves, cill, etc and similar works laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including ball nosing of exposed edges and including dismantling old stone slabs complete all as specified and directed.
M&L for providing post construction anti termite treatment alongwith external wall below concrete or masonry apron using chemical emulsion @ 2.25 Litres per linear metre including drilling and plugging holes etc in apron with cement mortar 1:2 (1 cement 2 coarse sand) complete all as specified and as directed.
M&L for anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement 2 coarse sand) to match the existing floors complete all as specified and as directed.
M&L for anti termite treatment of voids in masonry, alongwith wall below concrete or masonry apron using emulsion @ one litre per holes,soil under existing floors using emulsion @ one litre per hole, including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement 2 coarse sand) to match the existing floors complete all as specified and as directed.
M&L for anti termite treatment at point of contract of wood works by chemical (in oil or kerosene based solution @ 0.5 litre/hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new one 3mm thick glass panes with putty or fixed with beadings.
S&F in repair galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
M&L grinding and polishing of existing terrazo/kota stone in flooring and skirting/dado using suitable size of grinder stone butty as per requirement incl fillup of joints/disturbed portion with filling material of floor etc. (a) first stage : washing cleaning, joints filling (where required) by using grey /white cement and grinding the floor to achieve smooth and softness of surface. (b) Final stage : again cleaning, washing and grinding the floor by using suitable butty and polishing with bee wax polish to receive smooth floor as per direction by Engr-in charge.
S&F factory made PVC kitchen cabinet of required size including shutter fabricated by joining for 18mm thick PVC Celuka ply with each other using solvent cement adhesive and screws and 18mm thick sheet as backing of cabinet fixed with screws. Shutter of cabinet made out of prelaminated 18mm thick having density 600 kg/cbm bent at 90* and finish all edgesat level for making edge lipping 0.5mm thick PVC sheet leaping at all 4 edges using bonding tap etc incl 18mm thick PVC Shelves & Partation of required size and design approved by GE/Engr in Charge incl all necessary fittings and fixtures like nickle plated clip hinges, knobs, channels etc including dismantling boarding any description. Note : Items like cupboard knobs, stainless steel channel, CP plate clip hinges are included in the mentioned rates and as per specification. The measurement area shall be front elevation.
M&L surface dressing n. exc 15 cm deep in soft/loose soil.
Excavation in trenches n exc 1.5 m wide & n exc 1.5 m depth; for foundation etc and getting out in soft/loose soil complete all as specified.
M&L for plain cement concrete 1:4:8 type D-2 (40 mm graded stone aggt) as in foundations, filling & mass concrete complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified.
Removing excavated material, n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point at the descriation of contractor complete all as specified.
M&L for moorum/red bajri filling in floor or foundation, laid in layers n exc. 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in straight or curved on plan to any redius walls built in CM 1:4 complete all as specified & directed.
M&L for reinforcement cement concrete (Nominal Mix), 1:2:4, type B-1(20 mm graded stone aggrigate) as in slab supported on walls & columns, landings, balconies, deck slabs & in shelves, water trough & the like complete all as specified .
M&L for reinforcement cement concrete (Nominal Mix), 1:2:4, type B-1(20 mm graded stone aggrigate) as in beams, bands lintel over 1.5 m span complete all as specified.
M&L for Reinforcement cement concrete (Nominal Mix), 1:2:4, type B-1(20 mm graded stone aggt) as inFoundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
M&L for reinforced cement concrete 1:2:4 type B-1 (20mm graded aggregate) as in linColumns, pillars, piers, posts and strut complete all as specified.
Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified.
Form work to sides of concrete foundation, footings, bases of columns, raft & raft beams, sides and soffits (if any) of foundation & plinth beams and similar work, vertical or to batter- Rough finished surface of concrete : Flat complete all as specified.
Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified.
Form work to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified.
M&L precast kerb stone built in PCC 1:2:4 using 20mm graded stone aggregate and fixing in CM 1:4 all as specified and directed.
M&L for 80mm thick machine pressed precast interlocking paver blocks of any shape & size conforming to IS-15658-2006 of M-35 grade with grey cement & pigment complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement; 4 coarse sand) furrowing the under layer with scatching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately).
S&F factory made solid PVC Moulded door shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded Prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face complete.
S&F rotational moulded polyethylene 500 Ltrs water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I complete all as specified.
S&F vitreous china bowl urinal flat back, size of 465mm x 355mm x 265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified.
S&F 15 mm bore brass CP pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified.
S&F 20 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified.
S&F 32 mm bore waste fittings, brass, chromium plated for glazed ware basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified.
M&L Cutting into existing manholes for connecting new drains, making good to pipe 150mm bore and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified.
S&F 150mm dia salt-glazed stoneware drain pipes laid in trenches and jointed as specified.
M&L concrete bed to drain pipes 150 mm including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified.
PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified.
PVC (SWR) bends any radius 75 mm bore complete all as specified.
PVC (SWR) vent cowl complete all as specified.
PVC (SWR) floor trap plain with grating including jointing with solvent cement dia of outlet 75mm complete all as specified.
M&L for rendering 10mm thick on stone masonry, brick work or concrete surface in cement mortar 1:6 and finished smooth and even without using extra cement complete all as specified.
M&L for rendering 15 mm thk with WPC on stone masonry, brick work or concrete surface in cement mortar 1:4 and finished smooth and even without using extra cement complete all as specified.
M&L hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and lev- elled in layers n exc. 15 cm thick, watered and rolled/ rammed to a true surface complete all as specified.
M&L 50mm thick cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggt) as in plinth protection including forming groove 10 mm wide & 30 mm deep & filled with bitumenous filler complete all as specified without using extra cement complete all as specified.
S&F 5.5mm thick sheet glass of ordinary quality and glazing with oil putty/beads fixed with metal panel pins in square exc 0.50 sqm in each.
S&F sheet glass, ordinary quality 4.80 mm thick fixed with rubber beading and clips size of glass n.exc 2 sqm in each pane complete all as specified & directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
M&L for powder coated aluminium frame for door/ window with one or more rebated including jointing cleat for fixing etc complete all as specified and minium thickness of powder coating 50 micron) complete all as specified.
S&F powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21, 100mm long (2 No) suitable handle (1 No) complete all as specified
Taking down carefully copper/aluminium point wiring for one light /socket/power point and taking down of teak wood batten/ PVC casing caping and making good disturbed surfaces of walls/ ceiling/ floors etc including dismentling of fittings complete all as specified.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS and including wooden boxes fixed on wall with and including 3mm thick phenolic laminated sheet top cover for mounting switches, sockets, fan regulators etc complete all as specified.
All as per serial item No 175.00 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No 175.00 here-in-before but for one exhaust fan point controlled by one switch and regulator.
All as per serial item No 175.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
All as per serial item No 175.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item No 175.00 here-in-before but for one 3 pin socket outlet 15/16 Amps controlledby one 15/16 Amps switch on independent board with 2.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230 Volts complete all as specified and directed.
S&F switch piano flush type, single pole, two way, 5 Amp, 230 Volts complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230 Volts complete all as specified and directed.
S&F socket outlet for 3 pin (with 2 pin outlet also), 5/6 Amp, flush type 240 Volt complete all as specified and directed.
S&F socket outlet for 2 in 1, 3 pin 5 & 15 Amp, flush type 240 Volt complete all as specified and directed.
S&F ceiling rose surface bakelite 65 x 50mm two or three terminals complete all as specified and directed.
S&F decorative ultra slim liner LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for 16 Watt to 20 Watt with LED tube of model E-LITE LED Pride Plus and connecting up with and including three core, PVC insulated, sheathed copper conductore cable of required size and length from ceiling rose to fitting complete all as specified & directed. Make : Havells Cat Part No LHEXBHP71NW018 or equivalent of Philips/ Crompton Greaves /Bajaj/Wipro.
S&F LED type security light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED complete all as directed. Make Havells Superb Cat part No LHEXAYP7PN6K020 or equivalent of Philips/ Crompton Greaves/ Bajaj/ Syska
S&F LED bulb 10/11 watt complete all as specified and directed. Make : Havell's/Crompton/ Syska.
S&F lamp holder PVC/Polycarbonatetype with back plate suitable forbatten fittings complete all as specified.
S&F stepped type electronic fan regulator, flush type and connecting up ISI marked 240 volts complete all as specified & directed.
S&F sheet metal enclosures, double door type, suitable for fixing MCB SPN with 200 Amps rated bus bar, 8 way, 240 volts complete all as specified and directed.
S&F sheet metal enclosures, double door type, suitable for fixing MCB SPN with 200 Amps rated bus bar, 4 way, 240 volts complete all as specified and directed.
S&F MCB 63 Amps, triple pole & neutral, 415 Volts complete all as specified and directed. Make : Legrand/ Havells/ABB
S&F MCB 32/40 Amps, single pole & neutral, 240 Volts complete all as specified and directed. Make : Legrand/Havells/ABB
S&F MCB 6-40 Amps, single pole, 240 Volts 'C' curve, 10KA ISI marked as per IS/IEC 60898-1 2002 complete all as specified and directed. Make : Legrand /Havells /ABB
S&F sub main wiring on including passing throuh PVC conduit pipe 1100 volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 Sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to IS 694/1990 including taking down existing unserviceable sub main wiring. (Note : Two runs of cable with one run of earth wire and one run of PVC casing caping should measured as one length).
S&F 2nd class hard wood rectangular block open recessed of size 30 x 25 x 5 cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawlplug(4 Nos), complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty LT underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 25 sqmm 4 core laid in trenches, along poles through pipes etc complete all as specified & as directed. (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately including taking down old unserviceable XLPE cable. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty LT underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 10 sqmm 2 core laid in trenches, along poles through pipes etc complete all as specified & as directed. (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately including taking down old unserviceable XLPE cable. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Excavation in trenches n.exc 1.5M wide and n.exc 1.5M in depth for foundation and getting out in soft/loose soil all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25cm deep as in soft/loose soil copletete all as specified.
Removing excavated material n exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point.
M&L for brick work with fly ash bricks {As per IS-13757 (1993) burnt clay fly ash building bricks}, (Old size bricks) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection complete all as specified & directed.
M&L dry sand (tibba sand) and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L 40mm grade GI pipe (light grade) for protection of LT cable fixed to wall /pole /road crossing including clamps complete all as directed.
Disconnecting from elect connection and taking down carefully the existing electric energy meter of any capacity, any make, any size and depositing the same in AGE E/M Store Yard all as specified and directed by the Engineer-in-Charge. Refixing the same inside the old meter inside box carefully including necessary electric connections complete all as directed.
S&F ceiling fan 1200 mm sweep, 5 star rating suitable for 230 Volts, 50 Hz, AC supply with down rod & canopy including provision of fan hook in ceiling for fixing of ceiling fan including necessary electric connection with 1 Sqmm, three core, flexible copper multistranded conductor cable all as directed.
S&F exhaust fan of 300mm sweep heavy duty, 300 RPM, 240 volt, 50 Hz AC supply including provision of hole in wall of suitable size for fixing of exhaust fan all as directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/ equipment and testing on including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed.
M&L for form work to soffits of suspended slabs, such as in roof slab, floor slab, landing, shelves and the like in horizontal or vertical not exc. 200mm thick rough finish flat surface complete all as specified.
Hitesh Construction
M/s ASK Enterprises
M/S GAURI CONSTRUCTION
GAR CONSTRUCTIONS
M/s S Amarjit Singh
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .