Tender Value
₹14.6 L
EMD Value
₹29,200
Closing Date
2 Jan 2020, 6:00 pmClosed
GE JUTOGH
GE JUTOGH JUTOGH CANTT SHIMLA (HP) 171008
PROVN OF LED SECURITY LIGHT WITH POLE AND OTHER CONNECTED ACCESSORIES FROM CHERRY CROSSING TO PUMP HOUSE JUTOGH UNDER GE JUTOGH
2019_MES_304236_1
GE/JUT-51/2019-20
Open Tender
Civil Works
Item Rate
180 days
JUTOGH
CLASS E CATEGORY b (i)
6 documents required · 6 mandatory
₹500
GE JUTOGH
₹29,200
Yes
21 Jan 2020
6 Dec 2019
4 Jan 2020
6 Dec 2019
2 Jan 2020
20 Dec 2019
Amount
Supply and errecting steel tubular swaged pole, type 410 SP 31, 9 m long, in true vertical shape complete with Mild steel base plate and finial taper plug, bolts, nuts, washers and screws as per IS 2713 (Part II) 1980 made out of mild steel tubing including two coat of Aluminium paint 1st quality over a coat of red oxide primer and painting with black & white alternate strips of 30cm wide each externally from ground level up to 1.5 mtr with synthetic enamel paint and marking pole No / MES SL on pole complete all as specified and directed. Note :- Excavation and earth work, returning filling in, disposal of surplus soil, PCC shall be measured and paid separately under relevent item of schedule.
Excavation in trenches n.exc 1.5 m wide and in depth and getting out in soft/loose soil for laying cables, errection of poles complete all as specefied and directed.
Excavation in trenches exc 1.5 m wide and n.exc 3.0 m in depth and getting out in soft/loose soil for laying cables, errection of poles complete all as specefied and directed.
Removing excavated materials (soil) to a distance n.exc 50m and depositing where directed at level n exc 1.5 mtr above the starting point complete all as specified and directed.
Returning filling in including spreading levelling, watering and well raming in layers n.exc 25 cm complete all as specefied and directed.
M&L for PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed.
M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in coping incl necessary form work complete all as specified and directed.
S&F energy efficeint LED Street Light Luminaries 120 watt fitting aesthetically designed for road lighting with main housing made of Pressure dia casting with uniform thickness and proper heat sink design to esure fast heat dissipation, The LEDs should be mounted on MCPCB and should be fixed to the body with proper thermal conductive paste to ensure quick transfer of heat to heat sink. The LED shall be provided with modular lens and toughened glass cover fixed with screw to the main housing ensuring required through and spread as per relevant IS Specification. Degre of protection IP 66 protection, CCT 5700K (+/- 300 K) with operating voltage range 90V to 300 V complete all as specified and directed by Engr In charge. Make :-Polycab cat part No PCGLS T1 120 / Havells cat part No ENDURA CITY LINE RNEOSL120W LED 757 SASYBOTG / Philips Cat part No BRP322 LED 122 CW HE MR PC S3 XT / Crompton cat part No LSTN-120-CDL-A
Note : (a) Make of luminaire and driver shall be same. The driver shall be potted type and phase to phase protection 400V up to 8 housrs shall be provided. (b) Lumen efficiency shall be min 100 lumens / watt (c) CRI Shall be min 70 (d) Power factor of luminarie shall be min 0.95 (e) THD shall be max 10% (f) LM-79 report as per IS 16106 and LM-80 report from LED manufacturer of fitting shall be submitted before execution. (g) Inbuilt surge protection of 4 KV should be provided with external SPD should be of 10KV. (h) LED chips Make : Cree / OSRAM
S&F street light bracket made out of 40mm GI pipe medium grade of length1.4mtr and bend to shape for fixing of street light fitting including two Nos of FI 50x6mm clamps with suitable nuts and bolts complete all as specified and directed.
M&L for flexible cable three core PVC insulated, PVC sheathed multi stranded copper conductor of size 2.5 Sqmm for connection junction box / Distribution box to security light with proper fixing in pole into GI Pipe, clamp etc complete all as specified and directed. Note : Cost of GI pipe shall be measured and paid seperately.
S&F KIOSK box weather proof made out of PVC make Sinterx cat pat no GS JB 3020 or equivalent in FINOLEX/UNIVERSAL Switch gear/ Sintex and including made out of one piece mounted SMC base and door pole mounted hinged door size 333 x 233 x 200mm out side and 300 x 200 x 105mm inside dimension comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 10 Amp MCB for controlling the street light fitting including FI clamps 30 x 4 mm with necessary MS nuts bolts and washer including embossing/painting of Danger notice of size not less than 10 cm x 7.5 cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as directed. Make : Sintex / Hensal / Universal / Finolex
Supply & laying steel tubing, galvanized light grade, for passing / hanging of earth strip under road, or PCC floor or fixed on wall/ on pole or drain etc or wherever protection is required including necessary clamps and nut bolts with GI fittings complete all as directed and specified for the following bore of pipes:-
GI pipe 50m dia
GI pipe 40mm dia
GI Pipe 20 mm dia
M & L for pole earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to earth lead of wire 4mm dia by means of nuts, bolts, check nuts & washers made of galvanised iron protection pipe light grade of 20 mm dia and watering pipe medium grade of 15 mm dia and filled alternate layer of charcoal or coke and salt , watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No 3 of SSR Part I of 2009 connected to earthing test point or as directed by Engr-in-charge all specified and indicated including necessary excavation and earth work in hard / dense soil complete all as specified and directed. Note : GI Wire from Earth pit to pole/panel will be included in the quoted rates
S&F or passing through pipe, XLPE insulated, armoured, electric power UG cable (heavy duty) with aluminium conductor, 1100 volts grade, nominal cross sectional area 70 sqmm 3.5 core including cable gland, terminal lug etc and testing complete all as specefied and as directed.
All as per Srl item No 16.00 above, but for 50 sqmm 3.5 Core.
All as per Srl item No 16.00 above, but for 35 sqmm 3.5 Core.
All as per Srl item No 16.00 above, but for 25 sqmm 4.0 Core
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia conforming to IS, approved colour complete with fittings for cable protection complete all as specified and directed. Make: Dura line /finolex/Tele Rex / Rex
All as per Srl item No 20.00 above, but 50mm dia.
All as per Srl item No 20 above, but 80mm dia.
M & L for cable route indicator made out of CI 15 cm dia disc shaped with embossed letter (LT Cable) fixed to MS angle iron 40 x 40 x 5mm and 1 Mtr Long embeded in ground with PCC 1:3:6 type C1 using 20 mm graded stone aggregate of size 25 x 250 x 200 mm complete all as specified and directed.
Cutting/ boring of roads / pavement / hard standing manually for insertion of GI pipe for cable and making good to the disturbed road / pavement by appropriate material, complete all as specified and directed. Note: Cost of material for making good to the road as per existing by filling cold ready mix bitumen or equivalent material shall be included in the quoted rates.
Supply installation testing and commissioning SMART LED SECURITY LIGHT CONTROL Panel board pillar box of suitable size out door type factory fabricated, cubical panel, floor mounted double door, dust and vermin proof CPRI approved made out of 3.15 mm thick CRCA sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets on all sides and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus Bar strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation with and including the following accessories at MRS Jutogh
INCOMING
MCCB 200 Amps AC 4 pole 415 Volt 50 KA breaking capacity as per IEC 60947-2 adjustable thermal magnetic trip unit (TMD) range 200 Amp - 01 Nos Make : Schneider or equivalent in Legrand / ABB
OUTGOING
MCCB 100 Amps, AC 4 pole 415 Volt 36 KA Breaking Capacity as per IEC 60947-2 adjustable thermal magnetic trip unit range 100 Amp - 03 Nos (Outgoing,01 Spare) Make : Schneider or equivalent in Legrand / ABB
Phase indicating lamp LED Type for incoming and each outgoing connections. Make : AE, L&T, Schneider
Smart LED security light on / off controler 3 Phase 10 KVA complete with on-off contactor for collective control, suitable MCB for individual circuit, 3 phase panel meter, remote data monitoring, notification of faults, suitable for surge protection, rotary switch for mannual operation complete mounted in panel complete as per OEM instruction. Make Polycab or equivalent in Siemens/ Legrand / Schneider / ABB
G M CONSTRUCTION COMPANY
M/S kuldeep kumar khullar
M/S JAI MAA JAGDHAMBA CONSTRUCTION
M/S JOHN VASSELLY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .