| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.5 LAccepted-AOC | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹93.6 L+₹5.0 L (5.61%)Rejected-Finance NOT SPECIFIED | L2 | Rejected-Finance Bidder not quoted L1 rates | |
| 3 | L3₹94.3 L+₹5.7 L (6.46%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Bidder not quoted L1 rates | |
| 4 | L4₹1.0 Cr+₹13.3 L (15.0%)Rejected-Finance | L4 | Rejected-Finance Bidder not quoted L1 rates | |
| 5 | L5₹1.1 Cr+₹17.2 L (19.4%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L5 | Rejected-Finance Bidder not quoted L1 rates |
| Sl No | Description | Qty | Unit | Prasur Electricals & Engineering Co. L8 | United Sales Corporation L2 | TIMES HYDRO-ELECTRIC COMPANY L4 | Nexus Infratech L6 | M/S. Niksun Electro-Infra Private Limited L3 | Star Electrical L1 | Electricals India L7 | Adinath Technical Services L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing and commissioning of plinth mounted step-down outdoor type distribution transformer complete with all standard fittings as per IS: 1180 and latest amendments thereafter, LEVEL II (Maximum Total loss as per table 6 of IS 1180 part I 2014 and latest amendments thereafter at impedance 4.5% , 22KV /433 V (at No load) of Capacity 315 KVA, AC, 3Ph, 50 Htz 4 wire, core type, copper wound (copper 99.9% Purity Electrolytic grade wound), oil immersed naturally air cooled, Oil natural/Air natural (ONAN) with external cooling tubes/fins, vector symbol Dyn-11, HV-delta, LV-Star connected complete with off load type tap changer (OCTC) hand operated winding Tap for voltage variation from + 5% to -10% in equal steps of + 2.5% of HV, Permissible temperature rise shall not exceed the limits of 45°C when measured by resistance method for transformer winding and 40°C measured by thermometer for top oil. The transformer shall be double wound, core type, non ageing, high permeability CRGO Prime core grade M-OH/ZDKH/TCH grade including of First filling of new transformer oil of suitable dielectric strength complete all as specified and as directed. | 1 | Each | 22,49,500 ₹22,49,500 | 15,75,000 ₹15,75,000 | 17,04,000 ₹17,04,000 | 18,32,000 ₹18,32,000 | 16,25,000 ₹16,25,000 | 13,82,000 ₹13,82,000 Lowest | 18,65,047 ₹18,65,047 | 18,30,000 ₹18,30,000 |
| 2.00 | All as per Ser Item No 1.00 above but for 250 KVA complete all as specified and directed. | 2 | Each | 19,99,500 ₹39,99,000 | 14,15,000 ₹28,30,000 | 15,48,000 ₹30,96,000 | 15,21,000 ₹30,42,000 | 13,35,000 ₹26,70,000 | 12,64,700 ₹25,29,400 Lowest | 17,13,470 ₹34,26,940 | 15,20,000 ₹30,40,000 |
| 3.00 | Supply, install, testing and commissioning of plinth mounted step-down outdoor type distribution transformer complete with all standard fittings as per IS: 1180 and latest amendments thereafter, LEVEL II (Maximum Total loss as per table 3 of IS 1180 part I 2014 and latest amendments thereafter at impedance 4.5% , 22KV /433 V (at No load) of Capacity 200 KVA , AC , 3Ph, 50 Htz4 wire, core type, copper wound (copper 99.9% Purity Electrolytic grade wound) , oil immersed naturally air cooled, Oil natural/Air natural (ONAN) with external cooling tubes/fins, vector symbol Dyn-11, HV-delta, LV-Star connected complete with off load type tap changer (OCTC) hand operated winding Tap for voltage variation from + 5% to -10% in equal steps of + 2.5% of HV, Permissible temperature rise shall not exceed the limits of 45°C when measured by resistance method for transformer winding and 40°C measured by thermometer for top oil. The transformer shall be double wound, core type, non ageing, high permeability CRGO Prime core grade M-OH/ZDKH/TCH grade including of First filling of new transformer oil of suitable dielectric strength complete all as specified and directed. | 1 | Each | 15,30,000 ₹15,30,000 | 12,65,000 ₹12,65,000 | 13,98,000 ₹13,98,000 | 13,63,000 ₹13,63,000 | 12,00,000 ₹12,00,000 | 11,30,000 ₹11,30,000 Lowest | 14,67,730 ₹14,67,730 | 13,60,000 ₹13,60,000 |
| 4.00 | All as per Ser Item No 3.00 above but for 160 KVA complete all as specified and directed. | 3 | Each | 11,87,500 ₹35,62,500 | 9,20,000 ₹27,60,000 | 10,60,500 ₹31,81,500 | 11,85,000 ₹35,55,000 | 10,00,000 ₹30,00,000 | 8,65,000 ₹25,95,000 Lowest | 11,40,000 ₹34,20,000 | 11,85,000 ₹35,55,000 |
| 4.01NOTES FOR SER. ITEM NO. 1.00 TO 4.00 ABOVE : (a) The OEM of the transformers should have in house LAB Certificate for Accreditation from National Accreditation Board for Testing and Calibration laboratories. (b) Manufacturer /OEM must have type test / short circuit reports for each & every rating from CPRI / ERDA (matching all the major parameters including the Loss Figure) shall not be older than 5 years. (c) CPRI Short circuit test report for exactly similar transformer (matching all major electrical parameters including Loss Figure) shall not be older than 5 years to be furnished). (d) OEM should be BIS and BEE certified for all the ratings of the transformer that are to be submitted. (e) Rate quoted includes the cost of making and Testing of control wiring connection at the Transformer and RMU/VCB for the Temperature alarm/Trip, Gas alarm/Trip. The Control cable shall be measured and paid separately under relevant item. (f) The above job include the removal of electric connection from Old transformer and shifting it to MES Store yard within up to 2.5 Km all as directed by Engr-in-charge. (g) The transformer shall have complete standard fittings such as two earthing terminals with earthing symbols for body, Air release device, rating and terminal marking plates, conservator tank with oil filling hole, filter type drain valve and oil level gauge. The transformer shall also have dehydrating breather with first fill of dehydrating agent (silica Gel), drain cum sampling valve, winding temperature indicator and oil temperature indicator, lifting lugs for the complete transformer as well as core and winding assembly, pressure release device/explosion vent, unidirectional flat rollers, inspection holes, LV earthing arrangement. (h) HT side cable box type consisting of 3 numbers of Porcelain bushing with Brass rods complete with nuts and washers, with cable glands suitable for reception / taping out 3 core HT cable 22 KV grade of size upto 185 Sqmm and a LT side cable box consisting of 4 numbers of porcelain bushing with Brass rods (Bimetallic flexible connecter and copper bus bar of suitable rated capacity with insulator support) and an additional neutral terminal brought outside the LV cable box for earthing etcwith complete with nuts and washers, with cable glands suitable for reception / taping out 3.5 core LT cable 1100 V grade of size upto 400 Sqmm. | |||||||||||
| 4.02NOTES FOR SER. ITEM NO. 1.00 TO 4.00 ABOVE CONTD.... (j) The contractor shall submit a letter of acceptance from the transformer manufacturer along with a sample, seeking approval. The manufacturer must clearly confirm in the letter that their company agrees to provide all requisite details and documentationand certification requirements as mentioned in the succeeding paragraphs. (k) Expenses/cost of FAT and necessary travel/freight/conveyance/stay expense for inspecting/testing officers as nominated by accepting officer for FAT shall be included in the rate quoted. (l) The existing transformer currently supplies power to vital installations as directed by EIC. Therefore, uninterrupted power supply must be ensured during the transition phase. Until the new transformer is fully installed and commissioned, the existing transformer must be temporarily shifted to a nearby suitable location to continue providing power. Man and material required for this temporary arrangement is deemed to be included in the abve work. Man and material for adequate temporary fencing is to be provided around the temporarily relocated transformer to ensure safety and prevent unauthorized access. (m) The contractor or his authorized representative shall submit the complete documentation and certificates to the Factory Acceptance Testing officer detailed by the department. The details shall include but not be limited to : (i) Rating of Tapping parameters/steps of the transformer. (ii) Maximum permissible temperature rise in the Core and Oil of transformer. (iii) Manufacturer details of the material used in core/winding conforming to CRGO specifications, including, Grade of CRGO, name of the manufacturer along with supporting documents such as invoice copy, mill test certificate, customs certificate, and any other relevant proof. (iv) Test report of the Flux density of the core. (v) Test report of the Overflux withstand capacity, including duration (in minutes) the transformer can sustain for in overflux conditions. (vi) Test report for Noise level of the transformer, as per standard norms. (vii) No-load current consumptionPercentage of the transformer. (viii) Burr level certificate indicating maximum burr level value in the transformer. (ix) Certification of purity of copper used in transformer winding. (n) All transformer test reports must clearly indicate that they pertain to the transformer itself, along with the acceptance parameters and the applicable Technical Authority or literature—such as IS 1180:2014 (Part I) and its subsequent amendments, IS/IEC 60076, CBIP Manual 317, NEMA standards, or any other recognized Government authorized body. | |||||||||||
| 5.00 | Material and labour for construction of plinth for transformer (to withstand load Upto 315 KVA transformer of size 2.0mx2.0mx1.5m, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete brick masonry in CM 1:6, the top of plinth shall consist of 100 mm thick PCC 1:2:4 type B-1(using 20 mm aggregate) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface duly placed on two numbers of medium channel of size MC 100mm on floor plinth across the length of plinth for equal distribution of transformer load including dismantling and removing debris of old unserviceable plinth and depositing within upto 5 Km outside the defence land complete all as specified and as directed. | 7 | Each | 30,000 ₹2,10,000 | 32,500 ₹2,27,500 | 31,470 ₹2,20,290 | 40,000 ₹2,80,000 | 45,000 ₹3,15,000 | 55,000 ₹3,85,000 | 29,700 ₹2,07,900 Lowest | 40,000 ₹2,80,000 |
| 6.00 | Supply and laying HT XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) 22000 Volts grade (earthed) with aluminium conductor 3 core 95 sqmm ISI marked confirming to IS 7098 laid in trenches, duct, through pipe, under floor, on pole including jointing, testing and taking down old unserviceable cable any type and size complete all as specified and as directed. | 140 | RM | 2,099 ₹2,93,860 | 1,575 ₹2,20,500 | 1,410 ₹1,97,400 | 1,520 ₹2,12,800 | 1,850 ₹2,59,000 | 1,350 ₹1,89,000 Lowest | 1,566 ₹2,19,240 | 1,520 ₹2,12,800 |
| 7.00 | Supply, fix and testing of heat shrinkable end jointing kit for 22 KV (Earthed) grade cable for outdoor type termination jointing and complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cables of size 95 sqmm complete all as specified and as directed. | 14 | Each | 7,500 ₹1,05,000 | 10,000 ₹1,40,000 | 8,430 ₹1,18,020 | 4,626 ₹64,764 Lowest | 6,800 ₹95,200 | 28,000 ₹3,92,000 | 8,640 ₹1,20,960 | 4,626 ₹64,764 Lowest |
| 8.00 | M & L for earthing for sub station with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and including galvanised iron strip 32x6mm as earthing lead and GI pipe 40 mm dia light grade for protection of earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I including RCC cover 50mm thick in 1:2:4 type B0 with reinforcement 8mm dia at 75mm c/c, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit including excavation and earth work in any type of soil and testing on completion etc complete all as specified and directed.
(Note : Cost of earth lead and protection pipe upto 7.5m shall deemed to be included in quoted rate.). | 14 | Each | 9,200 ₹1,28,800 | 7,500 ₹1,05,000 | 7,800 ₹1,09,200 | 6,500 ₹91,000 Lowest | 7,000 ₹98,000 | 6,500 ₹91,000 Lowest | 6,950 ₹97,300 | 6,500 ₹91,000 Lowest |
Tender Value
₹97.8 L
EMD Value
₹1.7 L
Closing Date
2 Oct 2025, 6:00 pmClosed
COMMANDER WORKS ENGINEER PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
86210 SPL REPAIRS/REPLACEMENT AGAINST BER TRANSFORMER BELOW 500 KVA CAPACITY ALONG WITH OTHER CONNECTED ACCESSORIES AT AFMC UNDER GE (CENTRAL) PUNE
2025_MES_729331_1
86210 CWE PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE (CENTRAL) PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE (CENTRAL)
₹1.7 L
Yes
10 Jan 2026
4 Sept 2025
9 Oct 2025
4 Sept 2025
2 Oct 2025
25 Sept 2025
4 Sept 2025 - 10 Sept 2025
Amount
Supply, install, testing and commissioning of plinth mounted step-down outdoor type distribution transformer complete with all standard fittings as per IS: 1180 and latest amendments thereafter, LEVEL II (Maximum Total loss as per table 6 of IS 1180 part I 2014 and latest amendments thereafter at impedance 4.5% , 22KV /433 V (at No load) of Capacity 315 KVA, AC, 3Ph, 50 Htz 4 wire, core type, copper wound (copper 99.9% Purity Electrolytic grade wound), oil immersed naturally air cooled, Oil natural/Air natural (ONAN) with external cooling tubes/fins, vector symbol Dyn-11, HV-delta, LV-Star connected complete with off load type tap changer (OCTC) hand operated winding Tap for voltage variation from + 5% to -10% in equal steps of + 2.5% of HV, Permissible temperature rise shall not exceed the limits of 45°C when measured by resistance method for transformer winding and 40°C measured by thermometer for top oil. The transformer shall be double wound, core type, non ageing, high permeability CRGO Prime core grade M-OH/ZDKH/TCH grade including of First filling of new transformer oil of suitable dielectric strength complete all as specified and as directed.
All as per Ser Item No 1.00 above but for 250 KVA complete all as specified and directed.
Supply, install, testing and commissioning of plinth mounted step-down outdoor type distribution transformer complete with all standard fittings as per IS: 1180 and latest amendments thereafter, LEVEL II (Maximum Total loss as per table 3 of IS 1180 part I 2014 and latest amendments thereafter at impedance 4.5% , 22KV /433 V (at No load) of Capacity 200 KVA , AC , 3Ph, 50 Htz4 wire, core type, copper wound (copper 99.9% Purity Electrolytic grade wound) , oil immersed naturally air cooled, Oil natural/Air natural (ONAN) with external cooling tubes/fins, vector symbol Dyn-11, HV-delta, LV-Star connected complete with off load type tap changer (OCTC) hand operated winding Tap for voltage variation from + 5% to -10% in equal steps of + 2.5% of HV, Permissible temperature rise shall not exceed the limits of 45°C when measured by resistance method for transformer winding and 40°C measured by thermometer for top oil. The transformer shall be double wound, core type, non ageing, high permeability CRGO Prime core grade M-OH/ZDKH/TCH grade including of First filling of new transformer oil of suitable dielectric strength complete all as specified and directed.
All as per Ser Item No 3.00 above but for 160 KVA complete all as specified and directed.
NOTES FOR SER. ITEM NO. 1.00 TO 4.00 ABOVE : (a) The OEM of the transformers should have in house LAB Certificate for Accreditation from National Accreditation Board for Testing and Calibration laboratories. (b) Manufacturer /OEM must have type test / short circuit reports for each & every rating from CPRI / ERDA (matching all the major parameters including the Loss Figure) shall not be older than 5 years. (c) CPRI Short circuit test report for exactly similar transformer (matching all major electrical parameters including Loss Figure) shall not be older than 5 years to be furnished). (d) OEM should be BIS and BEE certified for all the ratings of the transformer that are to be submitted. (e) Rate quoted includes the cost of making and Testing of control wiring connection at the Transformer and RMU/VCB for the Temperature alarm/Trip, Gas alarm/Trip. The Control cable shall be measured and paid separately under relevant item. (f) The above job include the removal of electric connection from Old transformer and shifting it to MES Store yard within up to 2.5 Km all as directed by Engr-in-charge. (g) The transformer shall have complete standard fittings such as two earthing terminals with earthing symbols for body, Air release device, rating and terminal marking plates, conservator tank with oil filling hole, filter type drain valve and oil level gauge. The transformer shall also have dehydrating breather with first fill of dehydrating agent (silica Gel), drain cum sampling valve, winding temperature indicator and oil temperature indicator, lifting lugs for the complete transformer as well as core and winding assembly, pressure release device/explosion vent, unidirectional flat rollers, inspection holes, LV earthing arrangement. (h) HT side cable box type consisting of 3 numbers of Porcelain bushing with Brass rods complete with nuts and washers, with cable glands suitable for reception / taping out 3 core HT cable 22 KV grade of size upto 185 Sqmm and a LT side cable box consisting of 4 numbers of porcelain bushing with Brass rods (Bimetallic flexible connecter and copper bus bar of suitable rated capacity with insulator support) and an additional neutral terminal brought outside the LV cable box for earthing etcwith complete with nuts and washers, with cable glands suitable for reception / taping out 3.5 core LT cable 1100 V grade of size upto 400 Sqmm.
NOTES FOR SER. ITEM NO. 1.00 TO 4.00 ABOVE CONTD.... (j) The contractor shall submit a letter of acceptance from the transformer manufacturer along with a sample, seeking approval. The manufacturer must clearly confirm in the letter that their company agrees to provide all requisite details and documentationand certification requirements as mentioned in the succeeding paragraphs. (k) Expenses/cost of FAT and necessary travel/freight/conveyance/stay expense for inspecting/testing officers as nominated by accepting officer for FAT shall be included in the rate quoted. (l) The existing transformer currently supplies power to vital installations as directed by EIC. Therefore, uninterrupted power supply must be ensured during the transition phase. Until the new transformer is fully installed and commissioned, the existing transformer must be temporarily shifted to a nearby suitable location to continue providing power. Man and material required for this temporary arrangement is deemed to be included in the abve work. Man and material for adequate temporary fencing is to be provided around the temporarily relocated transformer to ensure safety and prevent unauthorized access. (m) The contractor or his authorized representative shall submit the complete documentation and certificates to the Factory Acceptance Testing officer detailed by the department. The details shall include but not be limited to : (i) Rating of Tapping parameters/steps of the transformer. (ii) Maximum permissible temperature rise in the Core and Oil of transformer. (iii) Manufacturer details of the material used in core/winding conforming to CRGO specifications, including, Grade of CRGO, name of the manufacturer along with supporting documents such as invoice copy, mill test certificate, customs certificate, and any other relevant proof. (iv) Test report of the Flux density of the core. (v) Test report of the Overflux withstand capacity, including duration (in minutes) the transformer can sustain for in overflux conditions. (vi) Test report for Noise level of the transformer, as per standard norms. (vii) No-load current consumptionPercentage of the transformer. (viii) Burr level certificate indicating maximum burr level value in the transformer. (ix) Certification of purity of copper used in transformer winding. (n) All transformer test reports must clearly indicate that they pertain to the transformer itself, along with the acceptance parameters and the applicable Technical Authority or literature—such as IS 1180:2014 (Part I) and its subsequent amendments, IS/IEC 60076, CBIP Manual 317, NEMA standards, or any other recognized Government authorized body.
Material and labour for construction of plinth for transformer (to withstand load Upto 315 KVA transformer of size 2.0mx2.0mx1.5m, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete brick masonry in CM 1:6, the top of plinth shall consist of 100 mm thick PCC 1:2:4 type B-1(using 20 mm aggregate) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface duly placed on two numbers of medium channel of size MC 100mm on floor plinth across the length of plinth for equal distribution of transformer load including dismantling and removing debris of old unserviceable plinth and depositing within upto 5 Km outside the defence land complete all as specified and as directed.
Supply and laying HT XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) 22000 Volts grade (earthed) with aluminium conductor 3 core 95 sqmm ISI marked confirming to IS 7098 laid in trenches, duct, through pipe, under floor, on pole including jointing, testing and taking down old unserviceable cable any type and size complete all as specified and as directed.
Supply, fix and testing of heat shrinkable end jointing kit for 22 KV (Earthed) grade cable for outdoor type termination jointing and complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cables of size 95 sqmm complete all as specified and as directed.
M & L for earthing for sub station with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and including galvanised iron strip 32x6mm as earthing lead and GI pipe 40 mm dia light grade for protection of earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I including RCC cover 50mm thick in 1:2:4 type B0 with reinforcement 8mm dia at 75mm c/c, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit including excavation and earth work in any type of soil and testing on completion etc complete all as specified and directed. (Note : Cost of earth lead and protection pipe upto 7.5m shall deemed to be included in quoted rate.).
Supply, installation commisionning and testing of chemical earthing with GI electrode 3 m long consist of GI pipe outer dia 76 mm and GI pipe inner dia 32 mm . Inner space should be compacted with dry chemical compound for enhancing conductivity all including boring, installation, transportation, earth work and sufficient quantity of ground enhancing backfill compound testing of soil condition, PVC pit cover and GI strip 32x6mm upto 7.5 m long etc complete all as specified and directed.
Supply and fixing GI strip 32x6 mm for extention of earth and connected to equipment or panel complete all as specified and directed.
Excavation in trenches not exc 1.5 wide and not exc 1.5 m in depth for foundation etc or for laying cable etc not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level not exc 50m above the starting point complete all as specified and as directed.
Supply and laying 150 mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. (NOTE : Sample / make of DWC pipe shall be got approved by contractor from GE prior placing bulk order.)
Supply and lay pipe galvanized, “Light grade”, including fittings 100 mm dia for cable protection with clamps nut bolts to fixed by clamp/ nuts-bolts etc. against existing MS channel of HT structure complete all as specified and as directed.
United Sales Corporation (BID ID -3438608)
M/S. Niksun Electro-Infra Private Limited (BID ID -3440093)
TIMES HYDRO-ELECTRIC COMPANY (BID ID -3439262)
Adinath Technical Services (BID ID -3439393)
Nexus Infratech (BID ID -3439732)
Electricals India (BID ID -3440309)
Prasur Electricals & Engineering Co. (BID ID -3437068)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .