Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC GF AKRITI TOWER 19 B VIDHAN SABHA MARG LUCKNOW PIN 226001 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹9.3 L+₹1.4 L (17.8%)Rejected-AOC | L2 | Rejected-AOC not lowest | |
| 3 | L3₹9.5 L+₹1.6 L (20.0%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L3 | Rejected-AOC not lowest | |
| 4 | Rejected-Technical RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | - | Rejected-Technical Due to not enlisted in eligible category |
Tender Value
₹7.3 L
EMD Value
₹14,600
Closing Date
4 Nov 2019, 6:00 pmClosed
AGE I CG
NOIDA
REPAIR AND MAINT OF FIRE FIGHTING SYSTEM UNDER AGE (I) CG NOIDA
2019_MES_289576_1
AGE I CGN 31 19 20
Open Tender
Miscellaneous Works
Item Rate
90 days
NOIDA
E c vi
7 documents required · 7 mandatory
₹500
AGE I CG
₹14,600
7 Aug 2020
16 Oct 2019
5 Nov 2019
16 Oct 2019
4 Nov 2019
23 Oct 2019
Amount
Comprehensive maintence, testing/Servicing and repair including preventive and periodical maint with renewals and replacement of defective parts of all existing fire protection and fire fighting system complete consisting of main fire control panels of 12.5HP & 75 HP Motor and Engine pump 62KW by necessary decarbonising ,cleaning, tightening & 100 % servicing of of all loose contact , sub panels,smoke/heat detector/response indicator Electric driven pump 55 KW, Diesel driven pump with 62 KW , Jockey pump, pressure switch, presure vessels, fire hydrents, hose reels, canvas hose pipes, gunmetals valves shut of nozzels sprenklers etc with control panel, starters and to keep Fire fighting system and fire alarm system auto run mode on variation in pressure to make 100% serviceability of the complete including checking, cleaning of fire detector by removing dust or dirt, cleaning of heavy greasy deposit if any, checking the connection of battaries, specific gravity of electrolyte, the alarm function control panel and indicating eqpts be checked by the opration of trigger device in each zone as described the system installed at Kamath Enclave offrs md accn (G+13 story Bldg) of CG Sec 52 of Noida every month during first or Last week as directed by Enginer -in-Charge. Note :- (a) Cost of new components shall be paid for separately under relevant item of shchedule 'A' (b) Contractor's rep will visit minimum once in a month to every panel and take servicibility certificate duly signed by the users and MES Rep. Additional visit as and when required will not be paid as extra. (c) Cost of minor spares any type not costing more than Rs 2500.00 per month in total deemed to be included in the quoted rate. (d) Payment will be processed on production of servicibilty certififace only and a panel recovery @ double the quoted rate will be charged for non carrying out of monthly serviceability check
NOTE :- (i) The rate quoted above shall be inclusive of minimum material as mentioned above and labour for unserviceable items, replacement of unserviceable eqpts and any other item not mentioned in the schedule but required to be replaced to make the Fire Fighting system serviceable complete all as directed. (ii) The bidder are requested to inspect the FF system to accertain the servicebility of all the equipments if any itesms required to be repaired or replaced are deemed to be included in the quoted rate. (iii) The rates quoted shall be inclusive T&P required for carrying repairs and stationery for maintaining records such as daily ,fortnightly,monthly,quarterly and yearly maintenence, complaints book etc all as described by the Engr in charge. (iv) Normally maintaenance shall be carried out in day time but in case of emergency /breakdown, it should be attenend at odd hrs/night times and additional manpower if required will be arranged by the contractor without any extra cost & rates. (v) The contractor shall provide the service of trained personnel, ITI qualified mechanic and oprator with 3 yrs exeperience & helper shall 12th pass and supervisor shall be minimum diploma certificate holder with 3 yrs exeperience in the trade. (vi) The contractor shall carry out daily routine checking of the complete system and rectify the minor /major defects noticed immediately. One seprate register to be maintained as complaint registor received from department /user user signature shall be obtained after rectifying defects, each time. If complaints are not attended within 24 hours, following penalties will be imposed and deducted from payment to the contractors ;- contractor on the contractor quoted rates shall be deemed to include the cost of daily routine checking of complete system, rectification of defects and cleaning of installation from inside and outside with cleaning materials. Rs 500/- for not attending the complaint and keeping it pending beyond 24 hours per complaint per day. (vii) All consumable & maint material such as oil, lubricants, grease, thimbles etc will be deemed to be included in the rate quoted against above schedule. (viii) The contractor will use only genuine/original new parts as approved by original equipment manufacturer during repair and old unserviceable materials should be kept at site till verifiaction and proper register to be maintained complete all as specified and directed by Engr-in-charge.
Comprehensive maintence, testing/Servicing and repair including preventive and periodical maint with renewals and replacement of defective parts of all existing fire protection and fire fighting system once in a month (During 1st or Last week) for 100% serviceabilty of the complete including checking of terrac pump with control panel staters, fire hydrent valves, hose reals, gate valves, to make 100% serviceability of the complete including checking, cleaning of fire fighting system by removing dust or dirt, cleaning of heavy greasy deposit if any, and indicating eqpts,meters be checked by the opration of trigger device in each at all floors as described the system installed at sailors md accn P-23 (G+07 story Bldg) of Coast Guard Sec 23 of Noida as directed by Enginer -in-Charge. Note :- (a) Cost of new components shall be paid for separately under relevant item of shchedule 'A' (b) Contractor's rep will visit minimum once in a month to every panel and take servicibility certificate duly signed by the users and MES Rep. Additional visit as and when will requiored will not be paid as extra. (c) Cost of minor spares any type not costing more than Rs 500 in total deemed to be included in the quoted rate. (d) Payment will be processed on production of servicibilty certififace only and a panel recovery @ double the quoted rate will be charged for non carrying out of monthly servibility check)
All as per item No 02 above bldg No P-24(G+ 06 story Bldg) at sec -23 complete all as specified and directed.
S&F Thermoplastic Hose 20 mm dia as per IS 12585 ,Hydrostatic test pressure 21 Kgf/cm2 complete all as specified and directed.
S&F in repair response indictor LED type complete all as specified and directed by Engineer -in-Charge. Make : Agni / FST / APPOLO / Siemons
S&F in repair fire Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed. Make : AGNI, DAKSH/ APPOLO/ SIEMONS
Supply and fix in repairs Addressable manual call point resettable type complete all as per IS standard complete all as specified and directed. Make : AGNI Surksha/Firex/Minimax
Supply and fix in repairs MCP glass of suitable size3"x4" or 4"x4" complete all as specified and directed. Make : AGNI Surksha/Firex/Minimax
S&F in repair fire alarm sounders / hooder electronic type singe phase with sound level 62 to 120 DB complete all as specified and directed. Make : AGNI Surksha/Minimax/Philips/Meltron
Supply and fix in repairs of sealed lead acid batterys 12V, 7Amp complete all as specified and directed. Make: Exide / Amron/ Okaya /AMCO
Supply and fix in repairs automatic Pressure switch electrically operated suitable for operating the fire fighting system complete UNIVERSAL type and connected to the panel for fire fighting pump complete all as specified and directed. Make : GURU/ RMCO/DUNFOSS
Supply and fix in repairs SS Ball valve / Butterfly valve 25 mm dia complete all as specified and directed.
Supply and fix in repair Resilent rubber lined single arc vibration eliminator (Shock Controller ) of size 80mm size suitalbe for existing FF system complete all as specified and directed. Make : ISI marked.
Supply and fix in repair Resilent rubber lined single arc vibration eliminator (Shock Controller ) of size 150 mm size suitalbe for existing FF system complete all as specified and directed. Make : ISI marked.
Supply and fix in repair Resilent rubber lined single arc vibration eliminator (Shock Controller ) of size 200 mm size suitalbe for existing FF system complete all as specified and directed. Make : ISI marked.
Supply only rubber gasket 4mm to 06mm thick complete all as specified and directed. Make : ISI marked.
Supply only Gland packing 6mm to 10mm thick supreme quality complete all as specified and directed. Make : ISI marked.
Supply only M seal in 100 gram packet each supreme quality complete all as specified and directed. Make : ISI marked.
S&F in repair PVC insulated single core stranded copper conductor conforming to IS: 694 (1990) 1100 volts grade 6 Sqmm, all as specified and directed by Engr-in-Charge. Make : HAVELLS/POLYCAB/GRANDLAY/FINOLEX
S&F in repair PVC insulated single core stranded copper conductor conforming to IS: 694 (1990) 1100 volts grade 10 Sqmm, all as specified and directed by Engr-in-Charge. Make : HAVELLS/POLYCAB/GRANDLAY/FINOLEX
S&F in repair PVC insulated single core stranded copper conductor conforming to IS: 694 (1990) 1100 volts grade 25 Sqmm, all as specified and directed by Engr-in-Charge. Make : HAVELLS/POLYCAB/GRANDLAY/FINOLEX
S & F in repair MNX -40 including inter connection with other contractors and acessories , complete all as specified and directed. Make : L & T or equivalent
S & F in repair MNX-32 including inter connection with other contractors and acessories complete all as specified and directed. Make : L & T or equivalent
S & F in repair MNX-95 with Aux contact 2NO+2NC including inter connection with other contractors and acessories complete all as specified and directed. Make : L & T or equivalent
S & F in repair MNX-110 with Aux contact 2NO+2NC including inter connection with other contractors and acessories complete all as specified and directed. Make : L & T or equivalent
S & F in repair spare contact coil for MNX-95/110, complete all as specified and directed. Make : L & T or equivalent
S & F in repair front mounting add on aux contact block for MNX series 2NO+2NC , complete all as specified and directed. Make : L & T.
S & F in repair electronic timer type ST-100, 415 volt, 50 HZ for 12-120 secs range, complete all as specified and directed. Make : L & T or equivalent
S & F in repair LED digital Voltmeter complete all as specified and as directed. Make: L&T/Secure/C&S Electric/Ducati
S & F in repair LED digital Ammeter, complete all as specified and as directed. Make: L&T/Secure/C&S Electric/Ducati
S & F in repair MCCB 32-100 Ams complete all as specified and directed. Make : Schneider/L&T/Legrand/C&S Electric/Havells
S & F in repair relay for MNX 50-80, 66-100A complete all as specified and as directed. Make: L&T/HPL/SIEMENS/AE/IMP
S & F in repair gun metal Shut off nozzles of size 20mm all as directed by engr in charge. Make:- AAG /WINCO /NITIN / MINIMAX/ NEW AGE/ SAFEX
S&F in repair gun metal gate/globe valve/SS Ball valve 20mm dia bore, with iron wheel head, screwed both ends, class-II and fixed complete all as specified and directed. Make: Dripless Faucets India/Flowjet/Ball Valve India
All as per item No 35 above but 25mm dia bore complete all as specified and directed.
Supply and fix in replacement, RRL fire Hose Type -A, 15M long 63 mm dia as with necessary instantaneous spring lock type coupling at the ends to match with landing valve/hose pipe/branch pipe with gun metal male and female coupling all as specified and as directed. Make: Newage/Dunlop/Cosmos/Flame Guard
Dismantling the Butter fly Valve 80mm to 200mm servicing/greasing and replacing of minor items if required renewal of rubber gaskets etc complete all as directed.
Supply, install, testing and comissioning of tubular batteries 12 V, 90 AH including copper terminal lugs complete and replace disconnecting old unserviceable 12V, 90/92 AH batteries with copper terminal lugs complete all as specified and directed. Make: Exide/Tata green/Amron
M&L for removing the wornout pressure gauge and replace the water pressure gauge 14 KG/Sq cm2 including replace the connected accessories and fittings etc , Make:Guru India or equivalent with test certificate complete all as specified and directed.
M&L for replace the worn out Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type, complete all as specified and directed.
M&L for replace the worn out Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating side wall type, complete all as specified and directed.
M&L for cleaning the fire sump of cap 2,00,000 ltrs including drain out the entire water, remove the slits complete , wash with bleaching powder etc. complete all as specified and directed.
M&L for cleaning the tarrace Tank of cap 5000 Gln including drain out the entire water, remove the slits complete , wash with bleaching powder etc. complete all as specified and directed.
M&L for remove the worn out pressure switch 0 to 12 Kg /sq cm range and replace with new one and replacement of worn out cables,connecting nuts etc. complete all as specified and directed
M&L for replacement of the Rubber washer for Male Female Coupling 63 mm. complete all as specified and directed.
.M&L for replacement of the Rubber washer Rubber washer for Branch pipe & nozzle 63 mm. complete all as specified and directed.
M&L for repair the MS fire pipe leakage of 80/100 mm pipe under floor in bldg no P/23 , with arc welding including patch up M.S piece plate with 5mm thickness including painting with syntheic enamal paint and necessary earth work ,excavation ,returning filling and making good the floor complete all as specified and directed.
Taking down fire exitinguisher cylinder from the fire stand /wall and refiling of Gas cylinder with multi purpose dry power suitalbe for class ABC, cylinder capacity 2 Kg including hydraulic pressure testing of cylinder complete all as specified and directed.
Taking down fire exitinguisher cylinder portable chemical fire existingusher water (gas pressure) type 09 Ltr capacity from the fire stand /wall and refiling of Gas cylinder including hydraulic pressure testing of cylinder complete all as specified and directed.
Taking down fire exitinguisher from site 50 Kg and charging of mechanic foam type fire exitinguisher cylinder including testing of cylinder all as directed by Engr-in-Charge.
Taking down fire extinguiser cylinder from the fire stand wall and refilling of gas cylinder carbon-di-oxside cylinder 22.5 Kg capacity including presure testing etc complete all as specified and directed.
M& L in repair 63 mm dia Rein Forced Rubber Lined Fire Hose (RRL) ISI Marked bearing IS:636 Type including ss binding wire complete all as specified and directed. Make: Newage/Dunlop/Cosmus/Flame Guard
M& L in replacement fuel filter curtriges primary and secondary for 62 KW kirloskar engine complete all as specified and directed.
M& L in replacement oil filter curtriges for 62 KW kirloskar engine complete all as specified and directed.
M& L in replacement solonoid switch for engine stop function for 62 KW kirloskar engine complete all as specified and directed.
Opening cleaning, heating , varnishing and refixing the Kirlosker motor of capacity 55 KW installed at Fire Fighting pump house at sector 52 complete all as specified and directed by Engr in Charge.
Opening cleaning, heating , varnishing and refixing the Kirlosker motor of capacity 12.5 HP coupled with jockey pump, installed at Fire Fighting pump house at sector 52 complete all as specified and directed by Engr in Charge.
M& L in replacement of Mechnical Seal of Kirloskar Jockey Pump 12.5 HP (Model No GB 32/26) after dismantling of Jockey from foundation,opening, including refixing the jockey complete all as specified and directed by Engr in Charge.
All as per item No 59 above but replacement of 02 Nos of water seal for capacity of 55 KW model No( SC250M) complete all as specified and directed.
M& L in replacement of Battary Charger 220Volt AC/12 Volt DC ,5 Amps compact panel mounting type suitable for Fire fighting panel for charging the battery of FF engine complete all as specified and directed by Engr in Charge. Make: Su-kam/Amco/WAC/BCH
M& L in replacement Engine Oil 15 W 40 for DG set 62 KW complete all as specified and directed by Engr In Charge. Make Castrol/Volvoline/OPCL
Supply and filling Coolent for Diesel Engine 62 KW complete all as specified and directed Engr In Charge. Make Lubinex/Feetguard
Supply and filling distilled water for Diesel Engine 62 KW complete all as specified and directed by Engr In Charge.
Opening of Diesel Engine 62 KW Engine Head for inspection, cleaning, and resurfacing and grinding of valves refixing and servicing of the DG set Complete and testing complete all as specified and directed by Engr In Charge. (Gasket and Other Spares Measured and paid seprately)
M& L in replacement Engine Tapped cover gasket set Suitable for Kirloskar 62 KW Diesel Driven Pump complete all as specified and directed by Engr-in-Charge.
M& L in replacement Engine Head Gasket Suitable for Kirloskar 62 KW Diesel Driven Pump complete all as specified and directed by Engr-in-Charge.
M& L in replacement Engine Chamber Gasket Suitable for Kirloskar 62 KW Diesel Driven Pump complete all as specified and directed by Engr-in-Charge.
Taking down of Fuel Injector Pump along with injector pipes and Nozzles from Diesel Engine 62 KW, cleaning, servicing, calibrating, refixing and testing of FIP and nozzles complete all as specified and directed by Engr-in-Charge.
M& L in replacement Radiator Hose pipe with clamps for Diesel Engine 62 KW complete all as specified and directed by Engr-in-Charge.
Taking down of Fuel Tank of Diesel Engine 62 KW and cleaning and removal of silt by cleaning of Diesel complete all as specified and directed by Engr-in-Charge.
Servicing of Fire Pump Control Panel for 01No 55 KW electric pump 01No 62 KW engine pump and 01No 12.5 HP Jockey pump by cleaning of all terminals including decarbonising/demoistering complete and replacement of unserviceable minor spares such as tube terminal, short piece of wires,screws, washers, tapes etc as required all as directed by Engr-in-Charge.
M& L in replacement of motor cooling fan blade for Kirlosker motor of capacity 12.5 HP complete all as specified and directed.
AMIT ASSOCIATES
Pradeep Bros
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .