Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.0 L+₹2.1 L (21.2%)Rejected-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹15.7 L+₹5.8 L (58.6%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
6 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aditya Vanka
GE Navy Lakshadweep Coast Guard Road Kavaratti Island UT Of Lakshadweep 682 555
REPAIRS AND MAINTENANCE OF MISCELLANEOUS EM ITEMS INCLUDING STREET LIGHTS LED BOLLARD LIGHTS PANEL BOARD AND FIRE DETECTION AND ALARM SYSTEMS UNDER GE NAVY LAKSHADWEEP
2021_MES_473902_1
8292/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NAVY LAKSHADWEEP
As per Tender documents
8 documents required · 8 mandatory
₹500
GE Navy Lakshadweep
₹29,000
Yes
7 Jun 2022
8 Sept 2021
8 Oct 2021
8 Sept 2021
6 Oct 2021
22 Sept 2021
10 Sept 2021 - 18 Sept 2021
60 days
Amount
Taking down high mast light fittings manually from 12 metre height steel pole and disconnectioning the SS rope and replacing the unserviceable the parts such as , double drum winch, 5mm diameter SS wire rope 5 runs, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial, outdoor stand mounted feeder pillar box and making the High Mast light fully functional including raising the hight Mast light fittings in its original postion and testing complete all as specified and directed by Engineer-in-charge. Note: (i) Cost of miscelleneous items which are not mentioned above but are required for satisfactory completion are deemed to be included in the rate quoted by the contractor. (ii) Rates for Oiling/greasing for chain/ rope, motor rewinding, Auto/Manual function of Timer panel etc... are deemed to be included in the quoted rate. (iii) LED flood lights,Timer , Aviation light and Cable will be measured and paid separately under the relevant items of the schedule
Supply and fix in replacement of 250 W LED floodlight luminaires suitable for high mast light fitting with die cast aluminium casing having IP 66 protection, complete all as specified and directed by Engineer-in-Charge. Make: Crompton Cat Part No. LFPI 250 CDL/60-M or equivalent in Philips/Bajaj/Wipro/Havells as approved by GE
Supply and fix in replacement of Aviation obstruction light fixed over high mast light, housing with high pressure, die cast aluminium, glass cover, UV protected, Stainless steel plate protection to LED unit, powder coated installation pipes along with other accesories necessary for fixing as per manufacturers instructions, complying with the ICAO (International Civil Aviation Organisation) Standards and recommended practices, complete all as specified and as directed by Engineer-in-Charge. Make: Philips Cat Part No. ObstiVision XGP500 or equivalent in Havells/Bajaj/Wipro/Crompton as approved by GE
Supply and fix in replacement of Timer switch with power contactor for high mast light complete all as specified and directed by Engineer-in-Charge.
Disconnection and taking down the unserviceable /corroded panel board & Supply and fix & testing of new Factory made floor mounted compartmentalised cubical panel board outdoor type made out of self supported 3.15mm minimum thickness made out of CRCA sheet conforming to IS 8623 totally enclosed with necessary ventilation, weather, dust and vermin proof (also to confirm IP -65 standard), front and rear opening and locking arrangment and duly powder coated with two coats of red oxaid primer over outside and inside complete the panel board, 433 V, 3 phase, 4 wire 50 Hz having copper bus bar of 4 pole, minimum 200 Amps capacity duly insulated with coloured R,Y,B&B sleeves, made of high coductivity 99.9% pure electroytic copper of ETP grade including suitable copper earth strip conforming to IS with supply and fixing the following, complete all as specified and directed by Engineer-in-Charge :- (i) MCB 63 A , 4P ,415 V ,10 KA as incomer (ii) Timer for Auto/Manual time setting of High mast lights (iii) Power contactors qty 2 Nos 4 P,415 V, 40 A with coil voltage 240 V (iv) Three phase starter for motor control
Supply and fix in replacement of 5 Core Copper flexible cable of size 2.5 Sqmm for high mast light fittings complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable UG cable of size up to 25 sqmm from trenches/duct/pipe and taking into credit, complete all as specified and directed. Note: Necessary earthwork shall be measured and paid seperately
Supply and fix and testing of strandard aluminium conductor,1100 volts grade heavy duty UG cable, XLPE insulated aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed LT UG cable of size 16 sqmm, 4.0 core, complete all as specified and directed by Engineer-in-Charge
Description all as per Sl item No.8 above but 25 sqmm 4.0 core complete all as specified and directed by Engineer-in-Charge
Supply and lay burnt clay bricks, sub class "B", Designation 75, keeping the width of the brick parallel to the length of the cable complete all as specified and as directed by Engineer In Charge.
Material and labours for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying, gently punned and stretching the cable complete all as specified and directed by Engineer in Charge. Note: (i) Punned thickness shall only be measured and paid. (ii) In case of non-availability of river sand, Ridled earth (Confirming with IS-1255) shall be used for sand cushioning after obtaining written approval from GE
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 depth and getting out soft/loose soil for laying cables/pipes/erection of poles etc… complete all as specified and directed by Engineer-in-Charge
Returning filling in, with excavated soils incl. spreading, levelling, watering and well ramming in layers n.exc. 25 Cms. complete all as specified and directed by Engineer-in-Charge
Removing excavated material/ surplus soil exceeding 250 Mtrs and n.exc. 500 Mtrs and depositing where directed at a level n.exc. 1.50 Mtr above the starting point, complete all as specified and directed by Engineer-in-Charge
Disconnection and removing unserviceable fire alarm control panel and Supply, fix and testing of Fire alarm control panel (FACP) complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules per loop complete all as specified and directed by Engineer-in-Charge
Disconnection and removing unserviceable MCP and Supply, fix and testing Addressable manual call point ( MCP) break glass type with alarm LED complete all as specified and directed by Engineer-in-Charge
Disconnection and removing unserviceable electronic sounder cum strobe and Supply, fix and testing, Addressable electronic sounder cum strobe complete all as specified and directed by Engineer-in-Charge
Disconnection and removing unserviceable sensor / detector and Supply, fix and testing Addressable multi sensor Detectors Photoelectric Optical -Heat +Smoke composite detector include B501 base ,sleek ,low profile design ,Re movable cover and insect resistant screen for simple field cleaning but ,Built in tamper resistant feature complete all as specified and directed by Engineer-in-Charge
Disconnection and removing unserviceable addressable control module and Supply, fix and testing Addressable controle module complete all as specified and directed by Engineer-in-Charge
Disconnection and removing unserviceable addressable control module and Supply, fix and testing short circuit isolators complete all as specified and directed by Engineer-in-Charge
Disconnection and removing unserviceable flexible copper conductor including supply and fixing of FRLS Armoured cable copper conductor 1.5 sqmm, 3 Core, drawn in and including metal conduit pipe of dia not less than 20 mm with ISI marking, complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs, LED bollard garden light with LED 8 Watt lamp with opal and aluminium reflector, integrated drivers, powder coated Aluminium housing and polycarbonate optical cover/lens material,overall height not less than 500 mm, with IP 65 ingress protection, including fixing on concrete foundation with suitable fixing arrangement as recommended by manufacture, complete all as specified and directed by Engineer in Charge. Make: Philips Cat Part No. BCP150LED150/WW PSU 220-240V 7043 or equivalent in Havells/crompton/Wipro/Bajaj/GE as approved by GE) Note: PCC foundation shall be measured and paid seperately
Supply and fix in repairs, Mushroom type LED Bollard lights for downward lighting, energy saving, environmental friendly, long life aesthetically designed die-cast aluminium landscape luminaire for diffused lighting with high power 16 Watt LED as light source, including fixing on concrete foundation with suitable fixing arrangement as recommended by manufacture, complete all as specified and directed by Engineer in Charge. Make: Havells Cat Part No. MUSHROOMBL16WLED730SSYMTOPC or equivalent in Philips/crompton/Wipro/Bajaj/GE as approved by GE) Note: PCC foundation shall be measured and paid seperately
Supply and fix in repairs, 36 W LED Street light luminaire, epoxy coated, enclosed with glass cover in frames with high power LED and unique peanut lens to ensure uniform distribution and higher spacing between poles and maintenance free system type, including fixing to poles with necessary fixing arrangement as recommended by manufacturer, complete all as specified and as directed by Engineer in charge. Make : Philips Cat Part No : BRP 409 LEDCW 034 MR PC S1 PSU GR LED system lumen 3400 or equivalent in Havells/crompton/Wipro/Bajaj/GE as approved by GE)
Disconnecting and removing the existing unserviceable/corroded street light steel tubular poles and supply and fix new FRP street light poles of height not less than 6.0 Mtrs, including fixing to concrete surfaces using necessary non-corrosive fixing/ bolting arrangements as per manufacturers instruuctions, complete all as specified and directed by Engineer in charge. Note : Earth work and PCC will be measured and paid seperately under respective items of the schedule.
Demolition of un-reinofrced concrete in any position complete all as specified and directed by the Engineer-in-Charge.
Material and labour for PCC (1:3:6), type C-2, using 40 mm graded aggregate for pole foundation complete all as specified and directed by the Engineer-in-Charge
Material and labour for PCC (1:2:4) type B-1, using 20 mm graded aggregate, for pole coping, complete all as specified and directed by the Engineer-in-Charge
KRA Engineering and Construction
R.K. Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .