| 1 | L1₹18.5 LQualified Make: Okaya
Model: Okaya 100Ah SMF Lead Acid Battery MAIN BUS STAND NEAR SYNDICATE BANK DHAULANA GHAZIABAD UTTAR PRADESH 245301 | HAPUR | UTTAR PRADESH | 245301 | Make: Okaya
Model: Okaya 100Ah SMF Lead Acid Battery | L1 | Qualified | |
| 2 | L2₹21.5 L+₹2.9 L (15.8%)Qualified Make: AMARON
Model: Amaron Quanta & 12V/26AH 15 GF DSIDC SCHEME 3 PHASE II OKHLA INDUSTERIAL AREA NEW DELHI 110020 SOUTH DELHI DADRA AND NAGAR HAVELI INDIA | SOUTH EAST DELHI | DELHI | 110020 | Make: AMARON
Model: Amaron Quanta & 12V/26AH | L2 | Qualified | |
| 3 | L5₹25.8 L+₹7.2 L (39.0%)Qualified Make: Okaya
Model: OKAYA 12V-100AH 26 D C GANDHI NAGAR 26 D C GANDHI NAGAR GANDHI NAGAR GANDHI NAGAR JAMMU JAMMU AND KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | Make: Okaya
Model: OKAYA 12V-100AH | L5 | Qualified | |
| 4 | L6₹25.8 L+₹7.2 L (39.0%)Qualified Make: AMARON QUANTA
Model: Amara Raja, Amaron Quanta 194 BRAMUNPARA ATCHALA MATH BALITIKURI BALITIKURI BRAMUNPARA ATCHALA MATH HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | Make: AMARON QUANTA
Model: Amara Raja, Amaron Quanta | L6 | Qualified | |
| 5 | L7₹26.1 L+₹7.5 L (40.6%)Qualified Make: HBL
Model: HBL Opti100 0 BHADAR KHAS EKDANGA KHAJANI BHADAR KHAS EKDANGA KHAJANI EKDANGA GORAKHPUR UTTAR PRADESH 273211 GORAKHPUR UTTAR PRADESH 273211 | GORAKHPUR | UTTAR PRADESH | 273211 | Make: HBL
Model: HBL Opti100 | L7 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
4 Jun 2018, 10:00 pmClosed
lead acid battery Lead Acid Battery ( 333 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 100 100 Warranty (Years) 2 Years 2 Years Battery Condition Dry Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 500 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn.
corresponding Ah Yes. - No.of cells per Battery (No.) 6 Cells for 12 Volt battery - 1/3 CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab Banglore - Name of the Lab Central Power Research Institute - Test Report No. 372EATDBT145OO47 - Test Report Date 21/10.2014 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells
and for Batteries made from them for use in portable applications NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Amarjeet Kaur 182101
Northern Command Signal Regiment
Near Chinar Shopping Complex 333 15 EMD Required No ePBG Required No
119379
GEM/2018/B/17037
lead acid battery
15 days
Jammu And Kashmir; Udhampur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| lead acid battery Lead Acid Battery ( 333 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1 | - | - | - |
| 2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1 | - | - | - |
| 2 & 3) with latest amendments Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 100 100 Warranty (Years) 2 Years 2 Years Battery Condition Dry Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 500 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn. | - | - | - |
| corresponding Ah Yes. - No.of cells per Battery (No.) 6 Cells for 12 Volt battery - 1/3 CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab Banglore - Name of the Lab Central Power Research Institute - Test Report No. 372EATDBT145OO47 - Test Report Date 21/10.2014 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells | - | - | - |
| and for Batteries made from them for use in portable applications NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Amarjeet Kaur 182101 | - | - | - |
| Northern Command Signal Regiment | - | - | - |
| Near Chinar Shopping Complex 333 15 EMD Required No ePBG Required No | - | - | - |
Exempted
4 Jun 2018
22 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_119379.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .