Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | L1 | Accepted-AOC Successful bidder | |
| 2 | L2₹44.9 L+₹15.3 L (51.6%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹69,800
Closing Date
13 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
PROVN OF CERTAIN B R AND E M MINOR WORKS 09 Nos AT AIR FORCE STATION SAMBRA
2023_MES_618262_1
8813/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Sambra
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE AF Sambra
₹69,800
Yes
11 Dec 2023
11 Sept 2023
16 Oct 2023
11 Sept 2023
13 Oct 2023
30 Sept 2023
Amount
Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise superficial area exceeding 500 sqcm but not exceeding 0.1sqm complete all as specified and directed
M & L Plain cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate as in coping bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work (straight or curved) etc complete all as directed.
Dismantling floor hearth/ wall tiling including cement mortar bedding (but not backing) and removing tiles & rubbish off the premises all as specified and directed.
M & L coloured Non skid ceramic tiles, 7 to 8mm thick (square or rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, set and jointed in neat cement slurry and pointed in white cement with pigment to match, as in floors over and including 15mm thick screed bed in cement mortar 1:6, all as specified and directed.
S & F mild steel framed work such as in barred iron doors, walkways, railings and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S & F welded steel wire fabric not exceeding 4 kg/sqm to steel members with welding or fixing with self tapping screw complete all as specified and as directed.
M & L Preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
S & F wardrobe hooks 50mm to 60mm (single), brass cromium plated fixed on plate (6 nos hooks per plate) fixed to wall complete all as specified and directed.
M & L Preparation of old treated wall surfaces and applying one coat of Acrylic distemper all as specified and as directed.
M & L Elegant Fabric Tile made of perforated cement fiber composite 600X600, 5mm thick minimum with square edge density 1050kg/m3 covered with fabric on the front side and Acoustics fiber on the back side, water resistance, and fire resistant absorption coefficient upto 0.89 at 160 Hz tested as per ISO 354. The tiles are anti-sag and are installed with Aluminum H Profile on G.I studs 600x600mm center to center 2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life with a backing of 50mm 1000 GSM thick absorbwool tested as per Fire Retardant IS 15061-2002 for excellent results complete all as specified and directed. Note : Manufacturer test certificate for fire retardant shall be submitted by tenderer before fixing / installation.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.5 m in depth for foundation etc.; or for shafts, wells, cesspits, manholes, pier holes not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in hard/dense soil all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 27cm deep and getting out in hard and dense soil all as specified and directed.
M & L Plain Cement Concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M & L Brickwork using old size sub class 'B' bricks in independent chimney shafts, curved on plan to any radius built in CM 1:4 complete all as specified and directed.
M & L Precast Reinforced Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels set in cement mortar 1:4 complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
M & L Mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L Mild steel TMT bars of 5mm and over upto and including 10mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spaces and binders
M & L for framed work such as grills, gratings, etc,. With ends of bars shouldered and / or riveted / weldded and similar work complete all as specified and directed.
M & L Rendering cement mortar 20 mm thick cement mortar 1:4 on fair face of brick work or concrete surfaces wall finished even & smooth without using extra cement all as specified and directed.
M & L Preparation of new plastered wall surfaces and applying three coats of white wash complete all as specified and directed.
M & L Broken stone or boulders for hardcore gauge not exceeding 63 mm, deposited spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface all as specified and directed.
M & L Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in 100mm thick sub base to floor complete all as specified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drives ways or light traffic parking etc., of required strength thickness and size/shape, made by table vibratory method using over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of interlocking paver blocks in to the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not be more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
S & F Rolled mild steel work in framed work as in doors or gates of angles or other section with gusset plats, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running, rails and guiedes) and hanging; also fastening and fixing, grade Fe-290 (Gde E 165) complete all as specified and directed.
M & L Mild Steel plates (plain or chequred) channel, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment Fe 410 W (Gde-E-250) Quality - B including fixing with riveting, bolting or welding all as specified and directed.
S & F mild steel butt hinges, size 100mm, heavy weight, cold rolled steel complete all as specified and directed.
M & L Preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L Sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100Volts grade 4 sq mm drawn through and including suitable size of non-metallic PVC casing caping/conduit and conduit accessories with one run 4 sqmm copper conductor FRLS cable as earth conductor fixed up in surface/recessed as required including connecting up complete all as specified and directed. NOTE:- Two runs of 4 sq mm cable and one run of 4 sq mm earth continuity copper conductor and one run of PVC conduit / casing caping shall be measured as one unit
M & L for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to copper strip 20 x 3 mm as earthing lead by means of nut, bolt, check nuts and washer of copper including PCC pit in PCC 1:2:4 type B-1, pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12 mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in Electrical Plate No 3 of SSR Part-I and testing on completion all as specified and directed.
S & F Distribution board SPN 4 way with 200 Amps rated bus bar, double door complete all as specified and directed.
S & F MCB SPN 40 Amps 240 Volts, C Curve complete all as specified and directed.
S & F MCB SP 40 Amps 240 Volts, C Curve complete all as specified and directed.
S & F Single pole and neutral enclosure with a two pin and earth plug and socket, IP-44, complete with one single pole MCB, 40 A, 240 Volts 'C Curve' complete all as specified and as directed. Note:- The industrial grade socket shall be compatible for 3 Pole (Phase, Neutral and Earth) IEC60309 standards compliant plug. All the contacts shall be of brass type. The enclosure material shall be of PC/ABS type.
S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volts with output voltage stabilized at 230 V with accuracy of +-2.5% and of capacity 5.0 KVA complete all as specified and directed.
M & L test point made by phosphorus bronze / gunmetal of size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm hexagonal head screw complete with saddles and fixing screws for fitting the strips complete all as specified and directed.
S & F copper strip 32 x 6 mm laid in trench/wall/floor etc with suitable porcelain insulator & GI Protection pipe of dia 40 mm with fittings including earth work etc complete all as specified and directed. Note:- G I protection pipe will be measured and paid seperately.
Supply only G I pipes 40 mm dia light grade galvanised all as specified and directed.
S & F Industrial Plug & Socket, IP-44, with one SPN MCB, 16 Amps, 240 Volts, 'C Curve' complete all as specified and as directed. Note:- The industrial grade socket shall be compatible for 3 Pole (Phase, Neutral and Earth) IEC60309 standards compliant plug. All the contacts shall be of brass type. The enclosure material shall be of PC/ABS type.
M & L Earthing with copper earth plate of size 600 x 600 x 3.15mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to using copper strip 25 x 3mm as earthing lead by means of nut, bolt, check nuts and washer of copper including PCC pit in PCC 1:2:4 type B-1, pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12 mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in Electrical Plate No 3 of SSR Part-I and testing on completion all as specified and directed.
S & F Copper Earth continuity conductor or main earthing lead 25 x 3 mm, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. including suitable porcelain insulator & GI Protection pipe of size 40 mm including earth work complete all as specified and directed. Note:- GI protection pipe will be measured and paid seperately.
Taking up Cast iron water main of size 100mm dia including all fittings for spigot & socket ends, lead joints including burning out lead joint & recovering lead complete all as specified as directed.
Supply and laying ductile iron pipe100 mm nominal dia, class K-7, spigot and socket including Rubber joints, complete all as specified and as directed. Note :- Specials and fittings will be measured and paid separately.
S & F Ductile iron fittings such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction, double branch, cross (all socket or socket and spigot or flanged and socket etc) coller, caps and plugs suitable for DI pipe upto 150 mm dia complete all as specified and as directed.
M & L Cutting the existing pipe line, insertion of Tee or fixing of slucie valves except DI specials complete all as specified and directed.
M & L Construction of brick massonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size with following specifications :- (i) PCC 1:4:8 type D-2 for foundation (ii) Brick work 230mm thick in cement mortar 1:6 (iv) Rendering 15 mm thick CM1:4 (v) Coping 75mm thick in PCC 1:2:4 type B-1 including 3.15mm M S sheet fixed on 50x50x6.0 mm angle iron frame work with two coats of synthetic enamel paint over a coat of red oxide primer with provision of locking arrangement (vi)Demolition of old valve pit and removing from site complete
Supply and fixing cast iron sluice valve 100 mm dia, PN 1.0 with both ends flanged confirming to the IS 14846 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc complete all as specified and directed
S & F Voltage stablizer for automatic operation, capacity 5.0 KVA ,three phase, naturally oil cooled, indoor type & designed for input variation between 300 Volts to 480 Volts with output voltage stablized at 415 Volts with accuracy of +/- 2.5% and speed of correction 8 Volts per second all as specified and directed
Supply, laying and testing L T under ground XLPE insulated stranded aluminium conductor cable of size 50 sqmm x 3.5 core, screened, PVC bedded, galvanised steel strip of wire armoured, electric power cables (heavy duty) 1100 volts grade all as specified and directed
S & F Distribution board, vertical TPN, incoming 4 way, outgoing 12 way having powder coated sheet metal enclosure fitted with bus bar, din channel, neutral link earth link, IP 43 protection and for accomodating MCCB including all as specified and directed.
Supply and fix MCCB 63 Amps, 4 pole, 415 volts, 16KA rupture capacity adjustable type all as specified and directed.
S & F MCB Single pole, 6 to 32 Amps, 240 volts, 10 KA rupturing capacity, C curve complete all as specified and directed.
S & F MCB Triple pole neutral, 6 to 32 Amps, 415 volts, 10 KA rupturing capacity, C curve complete all as specified and directed.
M & L Sub main wiring four single core PVC insulated cables with copper conductor 1100 Volts grade, 4 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit and conduit accessories / casing and capping fixed up walls, roofs, or floors including two runs of 4 sqmm PVC insulated cable earthing wire and connecting up complete including taking down of existing cable all as specified and directed. Note:- 6 runs of cable and one run of PVC conduit / casing & capping will be measured as one unit length.
M & L L T Cable route indicator with a welded/riveted disc of 4inch dia and engraved with cable route marker made out of angle iron 40X40X4mm thick dug in ground and fixing with PCC 1:3:6 type C1 using 20mm graded aggregate at approx distance 100 mtr including necessary earth work complete all as specified and directed
S & F Double Wall Corrugated HDPE Pipe IS-16205, size inner dia 50 mm, outer dia 63 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed by Engr-in-Charge.
Material, labour and testing for chemical earthing pit of suitable size with copper earth plate of size 900 mm x 600 mm x 5 mm thick burried in ground vertically to a depth not less than 4 metre below ground level with top edge of plate at a depth not less than 2.95 metre below nominal ground level with a bottom layer MgSO4 of 100 mm thick or 100kg whichever is more, earth plate surrounded with graphite powder, vegetable soil mixture, charcoal 250kg and salt crystal 200 kg around and 150 mm above the plate and MgSO4 100 mm thick or 100kg whichever is more at top layer and the remaining portion filled with excavated earth and connected with copper strip 32mm x 6mm duly brazed and by means of copper bolts, nuts and washers upto 7.5 metre length with G I pipe of suitable dia, not less than 40 mm for earth strip protection and connected to earthing test point, GI pipe light grade 25mm bore for watering with funnel and wire mesh complete including provision of earth pit with necessary earth work, PCC 1:2:4 type B1 chamber, Cast iron frame with hinged pit cover of size 12” x 12” having not less than 7 kilogram of weight complete all as specified and directed.
S & F LED lights fitting 1x20W, batten & Rod (Glass tube) double side connection. 220Volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F ceiling rose, 3 phase / PVC / Polycarbonate, isolated body surface all as specified and directed.
S & F switch piano, flush type single pole, one way 5 Amps all as specified and directed.
M & L Point wiring with PVC unsheathed multi-stranded 1.5 Sqmm FRLS copper cable drawn through and including PVC conduit of 25mm width with all accessories including MS sheet metal 1.2mm thick switch board or PVC rectangular switch board of suitable size fixed on wall including PVC unsheated multi stranded 1.5 Sqmm FRLS copper cable as earth continuity connected with common earth dolly for one light / fan point controlled by one, one way switch complete all as specified and directed.
S & F Exhaust fan, single phase, heavy duty, steel body, 300mm sweep, 900 RPM including fixing of mounting frame, blades and louver shutter on outer surface of the wall and connecting with and including three core flexible copper conductor 1.0 Sqmm cross sectional area of required length from ceiling rose to exhaust fan complete all as specified and directed. Note : Quoted rate is deemed to be included cutting in the round hole wall and making good the surface to match with the existing surfaces.
ASHIRWAD ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .