Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 CrAccepted-AOC | ₹8.9 Cr | L1 | Accepted-AOC Being L1 bidder |
Tender Value
Refer Docs
EMD Value
₹25 L
Closing Date
21 Jun 2022, 1:00 pmClosed
Registrar
NIT Meghalaya, Bijni Complex, Laitumkhrah Shillong
As per Tender Document
2022_NITM_691920_1
NITMGH/CPPP/ICT/22-23/321
Open Tender
Electronics Equipment
180 days
NIT Meghalaya Sohra Campus
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹25 L
Yes
5 Jul 2022
31 May 2022
22 Jun 2022
31 May 2022
21 Jun 2022
31 May 2022
Amount
Fiber-Optic Cabling components
48-core 9/125/250 Single mode dry core, Multi-tube (8T/6F), ECSS Armor, Bend insensitive, Outside Plant Fiber Cable, HDPE Sheath
12-core 9/125/250 Single mode dry core, Multi-tube, ECSS Armor, Bend insensitive, Outside Plant Fiber Cable, PE Sheath
SITC of Fiber LIU, 48F 1U Drawer Shelf, factory assembled with LC SM OS2 Pigtails, Adapters, Splice trays, Fiber management rings, splice sleeves and grounding lugs
SITC of Fiber LIU, 12F 1U Drawer Shelf, factory assembled with LC SM OS2 Pigtails, Adapters, Splice trays, Fiber management rings, splice sleeves and grounding lugs
SITC of LC/UPC - LC/UPC Single mode OS2 G.657A1 Duplex Patch Cord, LSZH, UL1685, 3 Meter
SITC of Outdoor Fiber Optic Joint Closure, dome and base type with mechanical seals, IP68 rated outdoor, suitable for upto 48F splice.
CABLING PRODUCTS FOR DATACENTER 24 Cu per rack
SITC of CAT 6A U/UTP Patch Cord, solid cordage, LSZH, 7 Feet
SITC of 24-port unloaded Modular Straight Jack Panel 1U, with rear cable management
SITC of Cat. 6A UTP Modular Jack Outlet, panel end
SITC of 2-port British Style Shuttered faceplate, UL 94V-0 rated
SITC of Cat 6A U/UTP 23 AWG Cable, ETL verified, LSZH 332-3 - Roll of 305 Mtrs
SITC of 1U, Single-sided horizontal Cable manager, finger-duct style
24F SM MPO per rack
SITC of Single mode MPO Module, 2x12F MPO rear ports to 24 LC fibres front ports (12 duplex), Method B wiring, with internal shutters
SITC of MPO/APC to MPO/APC, Single mode Bend Insensitive OS2 Pre-terminated Trunk Cable, 12-Fiber, LSZH jacket IEC 60332-3, UL, 10 m
SITC of MPO/APC to MPO/APC, Single mode Bend Insensitive OS2 Pre-terminated Trunk Cable, 12-Fiber, LSZH jacket IEC 60332-3, UL, 15 m
SITC of 1U sliding panel, accepts (4) MPO modules or adapter packs providing up to 48 duplex LC or 32 MPO ports, UL listed
SITC of LC/UPC - LC/UPC Single mode OS2 G.657A1 Duplex Patch Cord, LSZH, UL1685, 3 Meter
Cat 6 UTP Outdoor ECCS tape Armoured Triple Jacketed Cable, 305 mtrs
EQUIPMENT RACKS FOR DIFFERENT BUILDINGS
SITC of Equipment Rack - 15 U Wall Mount Rack (600mmD x 700mmW) DUAL SECTION : with front section - 15U x 600 mm x 600 mm and rear section - 15U x 600mm x 100 mm, lockable Glass door, side panel with hinges and slam latches and following accessories:
SITC of Rack mount power distribution unit, 1Ph, 230V, 8A, 50/60Hz, 2U standard with 6 X Universal Pin 5A/15A, Inlet Plug type 6A/16A Universal / Round Pin, 8A Fuse - PDU Rating 1.8KVA/Side feed-1.5Mt/ Black
SITC of Fan module Mount on top Cover with 1 fan 230VAC 90 CFM
SITC of 1U Horizontal Cable Organizer with Plastic Loops
SITC of Hardware Screws for mounting equipments pack of 20 Nos.
DATACENTER & NOC ROOM Preparation Requirement RAISED FLOORING OF DATACENTER
SITC of Antistatic Floor Tiles : with panels, size 600mm x 600mm shall be all Steel welded construction with an enclosed bottom pan of 49 hemispherical cones and 36 reverse cones. Panels should support : Uniformly Distributed Load (UDL) of - 3389 kg /Sqmt. Concentrated Load- 493 Kg.
SITC of Under structure Edge Support Rigid Grid ( ESRG) System suitable for finished floor height up to 300mm.
SITC of Air plug of size (235 x 172mm) with brush - for cable passage at the bottom of each Rack- per piece rate
Vacuum Panel Lifter
FALSE CEILING OF DATACENTER & NOC ROOM - using Fire-retardant tiles and light fixtures
SITC of Prelude 24mm exposed tee grid system fixtures for fixing Ceiling tiles - per sqft
SITC of Tiles with size 600mm x 600 mm fire retardant tiles for the Ceiling
SITC Ceiling Mount 36 Watt LED lighting fixtures with 3100 lumens, dimension 595 mm x 595 mm for Datacenter & NOC room area
WALL PARTITIONING AND GLASS DOOR INSIDE DATACENTER
SITC of Wall Partition inside Datacenter using Aluminium Frame of 100 mm thickness and double layer of aluminium sheet of thickness 12 mm
SITC of Wall Partition inside Datacenter using Aluminium Frame of 100 mm thickness and double layer of aluminium sheet of thickness 12 mm
SITC of Toughened Glass Door for NOC Room size 4 feet x 8 feet, Toughened Glass thickness : 20 mm, Aluminium Frame for the door should be powder coated with thickness of aluminium frame : 100 mm to be connected with door Hinge, door closer and Mortise Lock with door handle.
FIRE-RATED STEEL DOORS FOR DATACENTER
SITC of Entry Door to Datacenter : Steel Fire Rated Single Leaf Door Set - UIN-IS/BS-120 Min - 1,200.00X2,400.00 mm
SITC of Fire Exit Door from Datacenter Room : Steel Fire Rated Single Leaf Door Set - UIN-IS/BS-120 Min- 1480 x 2500 mm with Panic Bar
SITC of MAIN ENTRY DOOR TO DATACENTER AREA : Steel Fire Rated Single Leaf Door Set - UIN-IS/BIS-120 Min - 1480 mm x 2500 mm with Clear Fire rated Glass Vision Panel =, 6 mm for 120 Min, Schott Pyran S - 450 mm x 750 mm
DATACENTER INFRASTRUCTURE
SITC of Intelligent Integrated Rack Solution including the following components :
42 U Rack, 600mm ( W) X 1000 mm ( D ) , with integrated hot & cold aisle containment of 400 mm each , Vertical & Horizontal cable manager , blanking panels with rugged & light weight body structure with front glass door in front & rear non-perforated metal split door for effective air flow having a load bearing of 1000KG's
42 U Rack, 800mm ( W) X 1000 mm ( D ) , with integrated hot & cold aisle containment of 400 mm each , Vertical & Horizontal cable manager , blanking panels with rugged & light weight body structure with front glass door in front & rear non-perforated metal split door for effective air flow having a load bearing of 1000KG's
20 kW Precision Air Conditioner with variable capacity digital scroll / Inverter scroll compressor with N+N redundancy (After failure of any single unit, the total cooling requirement should meet), DX based, including copper pipe with proper insulation, tray, cable between indoor and outdoor unit with complete accessories including inbuild Heater & Humidifier, plumbing work
SITC of 1 U Remote Monitoring Unit with Temp Monitoring, Humidity Monitoring, Door Switch Sensor, Water Leak Sensor, Beacon Alarm, Event Alerts, RS485 Port, Email Notification, Power Monitoring etc:
SITC of 9" Touch Screen Human Machine Interface to provide a Local display for Integrated Infrastructure indicating various Power, Cooling, Environmental Parameter with Real Time PUE
SITC of Vertical Socket strip with 12nos of IEC C13 Sockets & 4 nos of IEC C19 Socket with 2.5 mtr power chord with 32A , Single Phase MCB. ( 02 nos PDU per rack )
SITC of Integrated Fire Alarm, Fire Detection & Fire Suppression system with control panel with required NOVAC 1230 gas, nozzles, gas release panel , etc.
SITC of Integrated VESDA system for early smoke detection
SITC of Integrated Ultra-sonic sound based Rodent Repellent System
SITC of Integrated Biometric Based Access Control system for all doors controlled through common access control panel
SITC of Electrical Power Distribution Panels ( inside utility panel ) with required internal cabling & MCCB/MCBs
SITC of 16-Port IP KVM switch with 18.5" LCD Console as per the mentioned technical specifications
SITC of 20 KW Rack tower convertible UPS system with battery bank as per specifications
Battery - OEM Approved : VRLA 12 V, 42 AH x 36 nos. (or Equivalent) - External 30 min Backup on Each UPS, combined backup 60 minutes, SNMP Card, battery racks complete with connection interconnection etc as required.
SITC of Low side material & DC Installation which should include the following components
16G Copper Piping between Indoor unit to outdoor unit
Condenser Cabling between Indoor to outdoor unit
Copper Pipe Insulation for Hot gas line and liquid line
MS Stands for mounting AC outdoor units – 02 nos
Drain Piping , 40mm dia PVC hard
R - 410A Refrigerant
Lifting, Shifting, Positioning & Installation at up to ground floor (without crane), Installation of Access Control and Fire suppression system, Installation of Rack, EMS and accessories, and PMC Charges
Potable water pipe for Humidifier
3 Years on-site Warranty for Entire Integrated Datacenter Rack Solutions - by OEM
UPS FOR OTHER BUILDINGS
Supply of 10 KVA Online UPS System - 3-Phase input and single-Phase output, with in-built isolation transformer, SMF Battery for 60 mints backup, Battery Rating: 12V 65 AH x 20 nos; MS Rack & IRIT Link cables for 20 nos of SMF Batteries - 3 Years on-site warranty on UPS & Battery.
1 KVA Online UPS: 2 U 19"" rack mountable with inbuilt SMF 2 x 9AH battery. Input voltage range 100 to 290 V AC, IGBT based, true online, dual conversion type. EPO & ECO mode facility, DG set compatibility, LCD display, programmable power management outlets, SNMP, USB, RS-232 communication, Noise level 50 dB max, EMI EN62040/2;2006, safety EN 2040-1-1;2003, performance IEC/EN 62040/3, CE BIS, ISO 140001 for the UPS.
ACCESS CONTROL SYSTEMS FOR DATACENTER DOOR
DOOR ACCESS for Datacenter Door, NOC door
SITC of Card Reader with PIN (13.56MHz MI fare/DESFire)
SITC of Exit Card Reader with PIN (13.56MHz MI fare/DESFire
SITC of Power Supply 12V DC , 2.5 Amp ( 1.5 A Load current , 1 A Battery Charging Current with UPS feature , only to be used each with DMCH01186579)
Accessories - Cables & connectors - lot
SITC of 600 lbs Double EM lock with LED indicator
SITC of Power Supply -12 V, 2 amp DC for every Door Lock and Card Reader - 1 for each door
Cabling
SITC of 1.25 sq. mm multistranded 2-core copper wiring (lock to controller to power supply - 3 mtr) - per door
SITC of 6-core 1.25 sq.mm multistranded copper wire cable - reader to controller - per door - 3 mtrs
SITC of Exit Switch per door
SITC of Access Card for IT staffs
SOFTWARE FOR ACCESS CONTROL
SITC of Access Control Software (32 Door Licence)
SITC of Workstation Software Licence (Software Only)
SITC of Server for Access Control Software : Intel Xeon Processor. 32 GB RAM/1 TB HDD / Radeon HD 7470 1 GB Graphics/ Redundant Power Supply (PSU)/ USB Mouse/Keyboard/ Windows 10 / 18.5" LED Display with 3 years Warranty.
IP SURVEILLANCE NETWORK 2 MP IR Bullet Camera with 100m IR Range
SITC of H.265 2MP Motorized Telephoto V/F IP Bullet Camera, 7-22mm, 100m IR, Micro SD, AC24V/DC12V/PoE, IP67/IK10, Smart IVA, with Conduit Box
5MP IR Bullet Camera with 70 m IR Range
SITC of H.265 5MP Motorized V/F IP Bullet Camera, 2.8-12mm, 70M, Micro SD, DC12V/PoE, IP67/IK10, Smart IVA with Conduit Box
4 MP PTZ Camera with 200m IR Range
SITC of H.265 4MP 32x Network IP PTZ Camera, 1/1.8” CMOS, 200M IR, SD Card 256GB support, Smart IVA with vertical pole mount
128 Channel NVR with VMS
SITC of Rackmount 4U Network Video Recorder for maximum upto 128 channel, dual GB NIC, HDMI, DVI-D, VGA (2 max. simultaneous), RS-232/485 serial port, RAID 6, Win10 or Ubuntu Linux 18.04 on SSD, redundant power supplies. Rackmount Sliding Rail Kit for the Server.
SITC of Enterprise SATA Hard Disk for storage of Video in the proposed NVR - 12TB 7200 RPM SATA 6Gb/s 256MB Cache 3.5-Inch Enterprise Hard Drive
SITC of IP Camera license, per camera.
SITC of 65" LED Display ( 24x7 operation) with Wireless keyboard & Mouse
NETWORKING SWITCHES
CORE SWITCH - on High Availability Mode
Core Switch : Layer 3 Switch with 48-port SFP+ 1/10GE/25 GE, 8x-port QSFP28 supports native 40GE or 100GE, includes Hot-Swappable Redundant (2) AC Power Supply and fans, with 3-year support, Premium License to use advanced Layer 3 features.
100GbE QSFP28 to QSFP28 Direct Attached, Passive Copper Cable, 1m. For connecting 2 nos of Core Switch on 100GbE Link .
10GBASE-LR, SFPP SMF (LC), for up to 10km over SMF, standard temperature (0°C to 70°C)
NETWORKING SWITCHES FOR ALL BUILDINGS
ACCESS SWITCH - TYPE-I : SITC of Layer 3 48 Port PoE Switch with 16x 100/1000/2.5G ports and 32x 10/100/1000 PoE+ ports with total Power Budget upto 1480 Watts per Switch or more, 8 x 10G SFP+ uplink-ports from day 1. Advanced L3 Support, 2 x Power Supply and Fan Units with 3 years support. AC Power Cord.
Access Switch - TYPE- II : SITC of 48-Port Layer 3 Switch with 48x 10/100/1000 PoE+ ports, 2x 1G RJ45 uplink-ports, 2x 1G SFP and 4x 10G SFP+ uplink-ports , 740W PoE budget, with Advanced L3 features , AC Power Cord with 3 years Warranty.
ACCESS SWITCH - TYPE-III : SITC of 24-Port Switch with 24x 10/100/1000 PoE+ ports, 2x 1G RJ45 uplink-ports, and 4 x 10G SFP+ uplink-ports , 370W PoE budget, basic L3 (static routing and RIP), AC Power Cord and with 3 years Warranty.
1 x 10GbE Direct Attach SFP+ to SFP+ Active copper cable, 1 m
10GBASE-LR, SFPP SMF (LC), for up to 10km over SMF, standard temperature (0°C to 70°C)
Network Management Solution (NMS) from the same OEM of Switching products to manage Network Switches - license per Switch
WIRELESS NETWORK EQUIPMENTS FOR THE CAMPUS
WIRELESS LAN CONTROLLER
SITC of Wireless LAN Controller Appliance with 4x10GigE and 4 GigE ports with Redundant Power Supply and Redundant FAN, must be capable of managing up to 2000 Wireless APs and 20000 clients. 3 years Warranty .
WIRELESS AP management license PER Access Point.
WIRELESS ACCESS POINTS REQUIREMENT
Indoor Wireless Access Point -Type I
SITC of Indoor Wireless AP WiFi 6 : dual-band 802.11abgn/ac/ax Wireless Access Points, 2x2:2 streams (2.4GHz/5GHz) OFDMA, MU-MIMO, 802.3af PoE support. 1 USB 2.0 Port, Type A, one 1G RJ 45 interface Includes Mounting Bracket .
Indoor Wireless Access Point - Type-II
SITC of Indoor Wireless AP WiFi 6 : dual-band 802.11abgn/ac/ax Wireless Access Points, 2x2:2 streams (2.4GHz/5GHz) OFDMA, MU-MIMO, 802.3af PoE support. 1 USB 2.0 Port, Type A, two 1G RJ 45 interface Includes Mounting Bracket .
Indoor Wireless Access Point - Type III
SITC of Indoor Wireless AP WiFi 6 with dual-band 802.11abgn/ac/ax Wireless Access Point with Multi-Gigabit Ethernet backhaul, 4x4:4 + 2x2:2 streams, OFDMA, MU-MIMO, dual ports, PoH/uPoE/802.3at PoE support. Includes Secure Mounting Bracket.
3 years Warranty Support for Wireless AP
OUTDOOR WIRELESS AP
SITC of Outdoor Wireless Access Point with omni directional in-built antenna, Wi-Fi 6, 802.11ax 2x2:2, dual band concurrent. One Ethernet port, PoE input. -20ºC to 65ºC Operating Temperature. Includes mounting bracket.
3 year Warranty Support for Outdoor AP
IP BASED TELEPHONE SYSTEM
IP PBX Server : Server based IP-PBX running on Linux OS and expandible upto 1500 Solution users (750 per Server) at a single site, up to 256 SIP trunk channels per Primary/Secondary server with hardened Platform and latest standards, complete in all respect. The minimum required configuration are as under: a) IP PBX should support the flexible connection of Analog, Digital & IP (H.323 and SIP) Desk Phone in any combination, Mobile WLAN and Soft Phones with in one system. It should support Redundancy with dual Servers such that the system shoud be able to switchover to other server in case of failure of one server. b) 128 Party Audio Conference bridge from day 1 c) in-built Voice Mail System of same OEM which should support Mail Boxes for all users.
License for IP/SIP Phones
IP PBX Gateway/Expansion with in-built 4-Port Analog Trunk Lines - expandable up to 16 lines
Digital Primary Rate Interface (PRI) Line with required license
UC Mobility Client Users for Laptop & Mobile Devices ( Android & iOS) - User License
3 years Warranty Support for IP PBX Server- on-site with spare replacement if required during warranty period
3 years Warranty Support for IP PBX Gateway - on-site with spare replacement if required during warranty period
IP Phone Type-I : Supply of SIP based full duplex IP Desk phone with 2.8” (diagonal) color display, 4 contextual softkey buttons and 4 administrable dual LED line/feature key buttons and 2 x Gigabit Ethernet Port (10 / 100 / 1000) line interface. Should comply with all the technical specifications as mentioned in the Specifications sheet.
IP Phone Type-II : Supply of SIP based full duplex IP Desk phone with 3.5” (diagonal) color display, 10 buttons with dual LEDs, 4 Context Sensitive Soft Keys and 48 administrative buttons, Supports optional Wireless Module for Wi-Fi connectivity, 2 x Gigabit, Ethernet with PoE support and option for Wi-Fi Module support. Should comply with all the technical specifications as mentioned in the Specifications sheet.
Operator Console : Supply of SIP based Operator Console IP Phone with Color display 3.5 inches (Diagonal), 8 Administrable Feature Keys and 4 Soft Keys and added with 24 keys Expansion Module ( Should support minimum 3 x 24 keys Expandable Modules), Dual Gigabit Ethernet Ports with PoE Class 1 Support, supports optional Wi-Fi Module for wireless connectivity to the network. Should comply with all the technical specifications as mentioned in the Specifications sheet.
Video Phone : Supply of SIP based Video IP Phone with 8” Capacitive Touch color display with Resolution of 1280 X 800 pixel with 1X USB Type-C port and 16 GB flash memory. Should have dual Gigabit Ethernet Ports and Inbuilt Hotspot. Should comply with all the technical specifications as mentioned in the Specifications sheet.
INSTALLATION, COMMISSIONING, PROJECT MANAGEMENT & ON-SITE SUPPORT CHARGES
Installation for Fiber-Optic Cabling -Building Connectivity in the Campus
Laying and Pulling of 48-core OFC cable along side of the boundary wall for the backbone OFC Ring. This must include cost of trenching of 1 meter, backfilling wherever required including clamps and all required accessories to complete the work.
Laying & pulling of Fiber Cables 48 /12-core OFC ( interbuilding and backbone cable to nearest building) using Steel Messenger Wire of 8 sqmm thickness & PVC Spiral Support for the OFC Cable using GI Poles of minimum 6 meter height & Outdoor Splicing Enclosure. All required clamps, cable ties & accessories to be included .
Laying & Pulling of 12-core inside building for floor to floor connectivity using the shaft available in the building. Necessary clamping should be done so that cable is not free hanging.
Supply and laying/ fixing of 40 mm dia HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, part II complete with fitting and cuttings, jointing, etc. direct in the ground ( 75 cm below ground level including excavation and refilling the trench, etc. wherever required and clamping with steel hose clamps as required to be used for laying of 48-Core OFC backbone cable through the boundary wall.
Supply and Erection of Poles : For Aerial Pulling of OFC cabled for inter-Building connectivity. Poles must have Usable height of 6 meters Min. Diameter 100 mm G.I. pole should be equipped with baseplate & required accessories for mounting on a suitable cement concrete structure to withstand the weight of Pole & the equipment to be mounted on the pole. Digging on hard rock upto the depth of 3 feet to fix the base structure of 4 feet for the Poles must be done for each poles. Should withstand at least 120 kgs of weight mounted on top of it when fixed. Effect of Wind speed of at least 60Kmph should also be considered. Certification : ISI Marked.
SITC of Dedicated Earthing for Integrated Datacenter
Supply & Installation of Clean Earthing system & connectivity up to integrated data centre via 1C x 50 SQMM copper flexible Cable (Green Colour) - 40 meter length Dedicated Chemical Earthing for the DC rack - digging of Earth Pit with 2.5 meter depth and 1 meter x 1 meter width on hard rocky soil behind the DC Room, using Electrode of 3 m long, each Earth Pit to be separated by 3 m from each other and back filled with Chemical Compound Mixture. Minimum Resistance of Earthing to be 3 Ohm
Supply Installation of Electrical DB Panel in the Battery Room installed with 125 Amp 4 Pole MCCB: Connecting the DB Panel using Single feeder of 3 Phase Supply of 40 meter of 4C X 50 SQMM copper flexible cable Up to Integrated rack system.
Wiring for light / power plug with 3 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 no. 4 sq. mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. (Point wiring for Power from Floor's Electrical DB to the Equipment Racks).
Supply and Wiring of 3-core, 4 sqmm FRLS PVC insulated copper conductor armoured cable for inter-rack connectivity for UPS power within building
Supply and Fixing following 3 Module GI Box and Face Plate with 1 x 6/16 amp Socket and 1 x 6/16 on/off Switch (modular socket & switches) which includes wall cutting and making good the same. ( at each rack Location)
Posting of one (1) no of trained Manpower for on-site support for 3 years after completion of implementation of the project.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid