| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹41.2 L Quoted ₹41.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹46.3 L+₹4.8 L (11.5%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹46.3 L+₹4.8 L (11.5%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹46.3 L+₹4.8 L (11.6%)Rejected-Finance KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | ₹46.3 L+₹4.8 L (11.6%) | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹48.5 L+₹7.0 L (16.8%)Rejected-Finance | ₹48.5 L+₹7.0 L (16.8%) | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹48.5 L+₹7.0 L (16.9%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹48.5 L+₹7.0 L (16.9%) | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹97,700
Closing Date
20 Jan 2023, 6:00 pmClosed
GE (UTILITIES) UDHAMPUR
GE (UTILITIES) UDHAMPUR, PO-GARHI, PIN-182121
Spl repairs for replacement of LT OH line with LT UG cable of unit KLP, provn of lightning protection system and LT panel cables in certain different locations under GE (Utilities) Udhampur
2022_MES_571013_1
GE/U-58/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹97,700
Yes
17 Mar 2023
23 Dec 2022
23 Jan 2023
23 Dec 2022
20 Jan 2023
6 Jan 2023
Amount
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) MCCB 400 amps, 4 pole, 35 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 01 Nos. Make :- L&T/Legrand/Schneider/ Havells/ C&S. (b) Bus bar electrolytic grade copper 600Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 250 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-1 Nos. Make :- L&T/Legrand/Schneider/ Havells/C&S. (b) MCCB 200 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-1 Nos. Make :- L&T/Legrand/Schneider/ Havells/C&S. (c) MCCB 100 amps, 4 pole,25 KA with adjustable thermal over load release 50 Hz, 415 volts grade -1 Nos. Make :- L&T/Legrand/Schneider/ Havells/C&S. (d) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. Make:- L&T/Legrand/Schneider/ Havells/C&S. Note 01- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) cable glands for incoming LT cable 240 sqmm -03 Nos and out going cables 95 sqmm -02 Nos and 50 Sqmm-2 Nos is including rate quated by vendover. Note 02 : LT panel shall be as per IS/IEC 61439 part I & II, TTA test certificate panel builder/with QMS and EMS certification like ISO 9001, ISO 14001 & ISO 45001.
All as per serial item No. 1.00 here-in-before but of following accesseries:- Incoming:- (a) MCCB 200 amps, 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No. Make:- L&T/Legrand/Schneider/ Havells/C&S. Outgoing:- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 300 Amp,4 pole - 01 set. (b) Digital timer complete assembly -01 set, including connected switch gear, controls and wiring etc. in one compartment -01. Note 01- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iv)Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) Cable glands for incoming LT cable 240 sqmm -01 Nos and out going cables 185 sqmm -02 Nos ,50 sqmm -01 Nos and 35 sqmm 5 is including rate quated by vendover. Note 02 : LT panel shall be as per IS/IEC 61439 part I & II, TTA test certificate panel builder/with QMS and EMS certification like ISO 9001, ISO 14001 & ISO 45001.
All as per serial item No. 1.00 here-in-before but of following accesseries:- Incoming:- (a) MCCB 160 amps, 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No. Make:- L&T/Legrand/Schneider/ Havells/C&S. Outgoing:- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 240Amp,4 pole, not less than 75 cm long mounted on insulators 01 set. (b) Digital timer complete assembly -01 set, including connected switch gear, controls and wiring etc. in one compartment -01. Note 01- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iv)Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming LT cable 185 sqmm -01 Nos and out going cables 150 sqmm -01 Nos and 50 sqmm - 01 Nos and 25 sqmm -04 Nos is including rate quated by vendover. Note 02 : LT panel shall be as per IS/IEC 61439 part I & II, TTA test certificate panel builder/with QMS and EMS certification like ISO 9001, ISO 14001 & ISO 45001.
All as per serial item No 1.00 here-in-before but of following accesseries:- Incoming:- (a) MCCB 250 amps, 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No. Make:- L&T/Legrand/Schneider/ Havells/C&S. Outgoing:- (a) Digital timer complete assembly -01 set, including connected switch gear, controls and wiring etc. in one compartment -01. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400 Amp,4 pole - 01 set. Note 01 - (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iv)Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming LT cable 185 sqmm -01 Nos and out going cables 150 sqmm -01 Nos ,35 sqmm -01 Nos and 25 sqmm - 3 is including rate quated by vendover. Note 02 : LT panel shall be as per IS/IEC 61439 part I & II, TTA test certificate panel builder/with QMS and EMS certification like ISO 9001, ISO 14001 & ISO 45001.
All as per serial item No 1.00 here-in-before but of following accesseries:- Incoming:- (a) MCCB 200 amps, 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No Make:- L&T/Legrand/Schneider/ Havells/C&S. Outgoing:- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 300 Amp,4 pole - 01 set. (b) Digital timer complete assembly -01 set, including connected switch gear, controls and wiring etc. in one compartment -01. Note 01- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iv)Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming LT cable 150 sqmm -01 Nos and out going cables 70 sqmm -02 Nos ,35 sqmm -04 is including rate quated by vendover. Note 02 : LT panel shall be as per IS/IEC 61439 part I & II, TTA test certificate panel builder/with QMS and EMS certification like ISO 9001, ISO 14001 & ISO 45001.
All as per serial item No 1.00 here-in-before but of following accesseries:- Incoming:- (a) MCCB 160 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade - 1 Nos. Make :- L&T/Legrand/Schneider/ Havells/C&S. Outgoing:- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 240 Amp,4 pole, not less than 75 cm long mounted on insulators 01 set. Note 01- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iv)Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) Cable glands for incoming LT cable 70 sqmm -01 Nos and out going cables 50 sqmm -01 Nos and 25 sqmm - 04 Nos is including rate quated by vendover. Note 02 : LT panel shall be as per IS/IEC 61439 part I & II, TTA test certificate panel builder/with QMS and EMS certification like ISO 9001, ISO 14001 & ISO 45001.
All as per serial item No 1.00 here-in-before but of following accesseries:- Incoming:- ( a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. Make:- L&T/Legrand/Schneider/ Havells/C&S. Outgoing:- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 150 Amp,4 pole, not less than 75 cm long mounted on insulators 01 set. Note 01- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iv)Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming LT cable 50 sqmm -01 Nos and out going cables 25 sqmm -04 Nos is including rate quated by vendover. Note 02 : LT panel shall be as per IS/IEC 61439 part I & II, TTA test certificate panel builder/with QMS and EMS certification like ISO 9001, ISO 14001 & ISO 45001.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 40x40x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete including taking down old U/S LT panel/busbar with following :- Incoming:- (a) MCCB 315/320 amps, 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No. (b) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 500 Amp,4 pole, not less than 75 cm long mounted on insulators 01 set. Make: L&T/Legrand/Schneider/ Havells/ C&S.
Outgoing:- (a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (b) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. Make: L&T/Legrand/Schneider/ Havells/ C&S. Note 01:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iv) Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. Note 02 : LT panel shall be as per IS/IEC 61439 part I & II, TTA test certificate panel builder/with QMS and EMS certification like ISO 9001, ISO 14001 & ISO 45001.
Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the and portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number. with black paint at suitable height complete all as specified and directed by Engineer-in-Charge. Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be included deemed tobe rate coated for contractor.
Thermoplastic, polystyrene unbreakable junction box size 260 x 210 x 116 mm suitable for pole mounted outdoor type IP 65 insulated complete with FI clamp & nut, bolts, washers and including phase seperator between R, Y, B terminals and one MCB SP 6 amp 10 KA, all duly mounted on din cannel, cable glands for cable entry complete all as specified and directed by Engr-in-Charge. Make : Hensel /Sintex
LED flood light with lens 120 watt made uppressure diecast aluminium housing with toughned glass and high power leds and secondary lens with IP 66 protection system of efficasy >110/125 LPW including 10 KV SPD including taking down old UNSV Street lights complete all as specified and directed by Engr-in-Charge.
PVC insulated multi stranded copper (in replacement) conductor PVC cable sheathed 2.5 sqmm 3 core and making connections of street light fittings and bollards lights complete all as specified and directed by Engr-in-Charge.
ACSR conductor of required size for Over head lines on poles including streching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor including Taking down the unserviceable conductor from OH structures complete all as specified and directed by Engr-in-Charge.
Angle iron , supports, clamps and back plates, fabricated from structural steel section including bolts, nuts, washers, welding, bending (cold or hot) drilling holes for bolts any shape or size as indicated or directed and inclusive painting with one primer coat of zinc chromate and two coats of aluminium paints complete all as specified and directed by Engineer-in-Charge.
Shackle type insulator pocelain viterous LT 1100 Volt 100x115mm including M.S. strip washers, insulator bolts, nuts complete all as specified and directed by Engineer-in-Charge.
LED Street light 60 watt (in replacement ) made uppressure diecast aluminium housing with toughned glass and high power leds and secondary lens with IP 66 protection system of efficasy >110 LPW including 10 KV SPD including taking down old UNSV Street lights complete all as specified and directed by Engr-in-Charge. Note :- Necessary fixing authority including reducers may be included in rate.
GI pipe bracket Suitable size of light single swan neck shape suitable to fix on top of tubular pole complete with clamps, nuts, bolts and washers complete all as specified and directed by Engr-in-Charge.
Automatic street light control switch of 8 KW ( in replacement ) three phase using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitabe rating power contractor (s), one Incoming and three Outgoing MCBs rating of 20-32 Amps & main load circuit wiring (copper) of min 10 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection class-2 (Hansel make). The circuit should be also have provision for manual operation (i.e. sensor by pass option) complete all as specified and directed by Engr-in-Charge. Make:-Model No SWADEEP 66- 8 KW3P or L&T/ Havells/ Indo Asian
Supply, Laying and fixing in replacement of along the poles or passing through pipes or laid under floor of through walls etc jointing and testing LT Cross Linked Polythene Insulated (XLPE insulated) galvanized steel strip armoured electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area as under including taking out old UNSV LT cables complete all as specified and directed by Engr-in-Charge. Note : Excavation, earthwork, Pipe for cable protection to be measured and paid for separately.
240 sqmm 3.5 core.
150 sqmm 3.5 core.
120 sqmm 3.5 core.
95 sqmm 3.5 core.
70 Sqmm 3.5 core.
50 Sqmm 3.5 core.
35 Sqmm 3.5 core.
25 Sqmm 3.5 core.
16 Sqmm 4 core.
16 Sqmm 2 core.
Supply, fixing and laying galvanised steel tubing light grade 80 mm dia (ISI marked) for protection of under ground cable on poles / walls under road crossing etc of following sizes including dismantling & taking down existing pipe complete all as specified and directed by Engr-in-Charge.
Boring of existing road/path for laying of GI pipe protection for UG cable including making good distrurbed area/surface complete all as specified and directed by Engr-in-Charge.
Providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc complete all as specified and directed by Engineer-in-Charge. Note:- (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-Charge.
Double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge. Make: REX/Tirupati Plastomatics Pvt Ltd.
Double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge. Make: REX/Tirupati Plastomatics Pvt Ltd.
Double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge. Make: REX/Tirupati Plastomatics Pvt Ltd.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
All all as per Srl item No. 24 here in before but depth exceeding 1.5m but not exceeding 3m complete all as specified and directed by Engineer-in-Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Emission lighting protection system with following para meters:- a) Radius of protection : 107 Mts b) Protection level : 01 c) Testing level : 100 KA d) Model : ESE or equivalent e) Make : SGI (or) equivalent
30 mtr self supporting GI mast with accessories complete all as specified and directed by Engr-in-Charge. Make :- SK Engineering works /Havells/ CG.
1x70 sqmm copper cable for inter connections complete all as specified and directed by Engr-in-Charge.
Class B three phase SPD complete all as specified and directed by Engr-in-Charge. Make :- SK Engineering works/Havells/ CG.
Bus Bar copper 100 Amps complete all as specified and directed by Engr-in-Charge. Make :- SK Engineering works/Havells/ CG
Lighting flash counter DM SGI counter complete all as specified and directed by Engr-in-Charge. Make :- SK Engineering works/Havells/ CG.
Maintanance free earthing compound ,copper bonded, earth rod and Copper earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the earth plate not less than 1.5 M below ground level connected to Copper strip 20 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate No 3 of SSR-2009 part 1, including necessary excavation and earth work in any type of soil, comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh, PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge. Note: - (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Mast 20 mtrs self supported tower for holds of light conductor complete all as specified by Engr-in-Charge. Make :- SK Engineering works/Havelles/CG.
RCC(1:2:4), inclusive of all binding materials( cement, motor, carse sand, dust,angle iron, nuts, bolts and tie rods) for fixing of high mast lighting conductor all as specified and directed by approved light protection certified vandor complete all as specified and directed by Engr-in-Charge.
Copper Strip 20x6 mm with PVC insulators/ saddles and fixing screws etc. for roof conductors and down conductors complete all as specified and directed by Engineer-in-Charge. Note : (i) Necessary T&P required for fixing of Copper strip is inclusive of rate quoted by contractor. (ii) Site clearance after fixing shall be done by contractor.
MOHAN LAL AND SONS
M/s Gh Qadir and Sons
PREM NATH KHAJURIA AND SONS
K S BUILDERS
vijay kumar gupta and co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .