Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.9 LAccepted-AOC RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | L-1 | Accepted-AOC being lowest and reasonable | |
| 2 | L-2₹21.0 L+₹2.1 L (11.0%)Rejected-Finance C O T ALI NEAR TRIPURA CASTLE ROAD CLEVE COLONY SHILLONG 793003 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793003 | L-2 | Rejected-Finance Other than lowest | |
| 3 | L-3₹22.8 L+₹3.8 L (20.3%)Rejected-Finance 16 GANGADHAR BABU LANE C R AVENUE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L-3 | Rejected-Finance Other than lowest | |
| 4 | L-4₹25.4 L+₹6.5 L (34.1%)Rejected-Finance | L-4 | Rejected-Finance Other than lowest | |
| 5 | L-5₹29.7 L+₹10.8 L (56.8%)Rejected-Finance BAID COMPLEX R K CHOUDHURY ROAD KUMAR PARA GUWAHATI 781001 ASSAM | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L-5 | Rejected-Finance Other than lowest |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
16 Jun 2021, 6:00 pmClosed
Garrison Engineer Umroi
Military Engineer Services Garrison Engineer Umroi Umroi Military Station PO - Barapani, Shillong-793 103
SPL REPAIR/REPLACEMENT OF US PANELS AND CABLES AT DIFFERENT SUB-STATION AND HPSV LIGHT FIITINGS WITH LED LIGHT FITTINGS ALONGWITH ALLIED SERVICS AT UMROI MIL STATION UNDER GE UMROI
2021_MES_438913_2
8501/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UMROI
As per tender/NIT documents.
6 documents required · 6 mandatory
₹500
GE Umroi
₹56,000
Yes
6 Jul 2021
20 May 2021
18 Jun 2021
20 May 2021
16 Jun 2021
3 Jun 2021
Amount
Excavation in trenches/foundation in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable, foundation and erection of poles etc. complete all as specified and directed.
Removing excavated material n.exceeding 50 m and depositing at a level n.exc 1.5 m above the starting point all complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming excavated soft/loose soil in layers n.exe. 25 cm each , all as specified and directed at site
Material & Labour for sand cushioning to under ground cable using locally available fine clean dry river sand over,under ground UG cable laid in treches and gently punning to cushioning to cable complete all as directed. Note : For the purpose of payment only punned thickness will be measured.
M&L for plain cement concrete (1:3:6) type C-1 using 20 mm graded aggregate in cover block of size 230x115x75 mm to cover LT underground cables , laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed.
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of pole / strut etc including necessary form work all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete 1:3:6, type C1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
Taking up/down UG cable of 240 sqmm 3.5 core size from trenches, ducts, floor, pipes, poles, etc. and removing unserviceable cables from site of work complete all as directed. (Note: Excavation and earth work will be measured & paid separately)
All as per Sr. Item No.08 here in before but cable size of 120 sqmm 3.5 core
All as per Sr. Item No.08 here in before but cable size of 95 sqmm 3.5 core
All as per Sr. Item No.08 here in before but cable size of 25 sqmm 3.5 core
All as per Sr. Item No.08 here in before but cable size of 16 sqmm 3.5 core
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty) of size 240 sqmm 3.5 core, aluminium stranded conductor 1100 volts grade, laid through duct/ pipe / in trench etc. including cable glands & lugs complete all as specified and directed.
All as per Sr. Item No.13 here in before but cable size of 120 sqmm 3.5 core
All as per Sr. Item No.13 here in before but cable size of 95 sqmm 3.5 core
All as per Sr. Item No.13 here in before but cable size of 25 sqmm 3.5 core
All as per Sr. Item No.13 here in before but cable size of 16 sqmm 3.5 core
Taking down old unserviceable GI tubing light grade of size 40 mm dia complete all as specified and directed
Taking down old unserviceable GI tubing light grade of size 50 mm dia complete all as specified and directed
Taking down old unserviceable GI tubing light grade of size 80 mm dia complete all as specified and directed
Supply & fix 40 mm bore GI tubing “light grade” in trenches/ on pole for protection of cables complete all as specified & directed.
Supply & fix 50 mm bore GI tubing “light grade” in trenches/ on pole for protection of cables complete all as specified & directed.
Supply & fix 80 mm bore GI tubing “light grade” in trenches/ on pole for protection of cables complete all as specified & directed.
Material & Labour for Earthing complete with Galvanised steel earth plate 60cmx60cmx6mm thick electrode, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 m below ground level , connected to GI earth strip 32 X 6mm up to test point by means of bolts ,nuts , check nuts and washers of GI including excavation and earth work, PCC 1:3:6 type C-1 pit, 20mm dia GI pipe medium grade, watering pipe and 20 mm bore GI pipe, light grade for protection of earth strip, MS angle iron frame 40x40x3mm, 10mm thick RCC 1:2:4 type B-1 cover reinforced with 6mm dia MS bars @ 75mm C/C both ways and with MS handle made out of 12mm dia bars, PGI Funnel, wire mesh etc complete all as shown in electrical Plate No 03 of SSR Part-I and connected to earthing test point all as specified or indicated including testing on completion including taking down old u/s excavation and earthwork shall be included in quoted rate, complete all as specified and directed..
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth lead wire 4 mm dia by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary excavation and eath works in any types of soil complete all as shown on Electrical plate No 3 of MES Schedule Part I including taking out the old earthing material complete all as specified and directed.
Dismantling and taking down old unserviceable LT panel board and supply, installation, testing and commissioning of size not less than 1.5m x 1.2m x 0.60m , outdoor cubical type factory made (CPRI approved) ,single hinged type door for individual MCCBs rubberised gasket, front & back side openable type with locking arrangement (screw type) , fabricated of CRCA sheet 3.15 mm thick supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar and interconnection between MCCB and bus bar will be done by aluminium strip only duly mounted on PCC floor and with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and aluminium lugs to accommodate and including the following :- (Location- SS No- 01 & 05) INCOMING:- (a) Aluminium busbar 600 Amps rated capacity-04 Nos. (b) MCCB 320-400 Amps, 4 pole, 415 volt, 50 kA adjestable thermal and magnetic setting type - 01 No OUTGOING :- (a) MCCB 250 Amps, 4 pole, 415 volt 50 kA - 04 Nos (One no standby) (b) MCCB 100 Amps, 4 pole, 415 volt 18 kA - 01 Nos (for street light). (c) Multifunction meter (Tri vectrometer) Model A,class 1, RS485 port with 3 Nos CT'S -01 No. (Make:L&T cat part No. WL411011OOOO or its equivalent in Legrand/Schneider) (d) Indication lamp Neon/ LED type (set of three) - 01 Set (e) 3 Pole power contactors type ML-04 with AC3 rating of 70 Amps and AC1 rating of 100 Amps- 02 Nos. (Make:L&T cat part No. SS90910 or its equivalent in Legrand/Schneider) (f) Digital programmable timer switch (24 hour), operating voltage 220-240 volt AC,50 Hz -02 Nos. (Make-Havells crabtree cat part No. DCTDD15016 or its equivalent in Legrand/L&T) (g) Danger Notice plate - 01 No. (h) Interconnection between MCCB and bus bar by Aluminium strip- 01Job. (Note:-fabrication works and assembly works of LT panel board should be done only by reputed companies like:- Indoasian / L&T / Havells)
Dismantling and taking down old unserviceable LT panel board and supply, installation, testing and commissioning of size not less than 1.5m x 1.2m x 0.60m , outdoor cubical type factory made (CPRI approved) ,single hinged type door for individual MCCBs rubberised gasket, front & back side openable type with locking arrangement (screw type) , fabricated of CRCA sheet 3.15 mm thick supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar and interconnection between MCCB and bus bar will be done by aluminium strip only duly mounted on PCC floor and with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and aluminium lugs to accommodate and including the following:- (Location- SS No- 15) INCOMING :- (a) Aluminium busbar 900 Amps rated capacity-04 Nos. (b) MCCB 630 Amps, 4 pole, 415 volt, 50 kA adjestable thermal and magnetic setting type - 01 No OUTGOING :- (a) MCCB 250 Amps, 4 pole, 415 volt 50 kA - 04 Nos (One no standby) (b) MCCB 100 Amps, 4 pole, 415 volt 18 kA - 01 Nos (c) Multifunction meter(Tri vectrometer) Model A,class 1,RS485 port with 3 Nos CT'S -01 No.Make:L&T cat part No. WL411011OOOO or its equivalent in Legrand/Schneider (d) 3 Pole power contactors type ML-04 with AC3 rating of 70 Amps and AC1 rating of 100 Amps- 02 Nos.Make:L&T cat part No. SS90910 or its equivalent in Legrand/Schneider (e) Digital programmable timer switch(24 hour),operating voltage 220-240 volt AC,50 Hz -02 Nos.Make-Havells crabtree cat part No. DCTDD15016 or its equivalent in Legrand/L&T (f) Indication lamp Neon/ LED type (set of three) - 01 Set (g) Danger Notice plate - 01 No. (h) Interconnection between MCCB and bus bar by Aluminium strip- 01Job. (Note:-fabrication works and assembly works of LT panel board should be done only by reputed companies like:- Indoasian / L&T / Havells)
Supply & fixing Aluminium lugs suitable for UG cable of size 3.5/4 core, 16 to 35 sqmm and making connection to MCCB/MCB including respective size of lugs for the neutral cable complete all as specified and directed..
Supply & fixing Aluminium lugs suitable for UG cable of size 3.5/4 core, 50 to 95 sqmm and making connection to MCCB/MCB including respective size of lugs for the neutral cable complete all as specified and directed..
Taking down carefully defective street light luminaries 70 watts / 150 watt/ 250 Watt and any wattage from the LT poles by disconnecting electric supply and removing from site complete all as specified and directed by Engr in charge.
Supply and fixing of 45W LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 5 kV and repair/replacement warranty of minimum 3 years. Make:Halonix cat part No. HLSLD-15-45-CWL-R, Jaquar Cat part No. LSRT01S045XC, HPL Product code HPLLEDSL4560E or its equivalent in Philips/GE
Supply and fixing of 60W LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 5 kV and repair/replacement warranty of minimum 3 years. Make:Halonix cat part No. HLSLD-15-60-CWL-R, Jaquar Cat part No. LSRT01S060XC, HPL Product code HPLLEDSL6060A or its equivalent in Philips/GE
Supply and fixing of 65W LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 5 kV and repair/replacement warranty of minimum 3 years. Make:Halonix cat part No. HLSLD-15-65-CWL-I, Jaquar Cat part No. LSRT01S060XC, or its equivalent in Philips/GE
Supply and fixing of 72W LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 5 kV and repair/replacement warranty of minimum 3 years. Make:Halonix cat part No. HLSLD-ML04-72-CWL, Jaquar Cat part No. LSRT01S072XC, HPL Product code HPLLEDSL7260A or its equivalent in Philips/GE
Supply and fixing of 100W LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 5 kV and repair/replacement warranty of minimum 3 years. Make:Halonix cat part No. HLSLD-10-100-CWL-S, Jaquar Cat part No. LSRT01S0100XC, HPL Product code HPLLEDSL10060E or its equivalent in Philips/GE
Supply & Fix for 32 mm dia GI tubing light grade bracket over all 1.2 mtr length with cutting as required and bend to shape with flat iron clamp of size 32mm dia 4 mm thick 2 Nos, nut bolts and washers complete for fixing street light on electric poles including taking down old unserviceable / fully rusted existing unserviceable one complete all as specified and directed.
Supply & Fix for 32 mm dia GI tubing light grade bracket over all 1.2 mtr length with cutting as required and bend to shape with flat iron clamp of size 40 mm 2 Nos, suitable size of nut bolts and washers complete for fixing street light fittings on electric poles including taking down old unsv / fully rusted existing unserviceable one complete all as specified and directed.
Supply & fixing PVC insulated cable with stranded aluminium conductor of size 2.5 sqmm 3 core flat connected with street light fittings to junction box or to the ACSR conductor complete all as specified and directed by Engr in charge.
S&F PVC cable Junction Box IP66 "halogen free and weather proof" for out door installation size 167 x 125 x 82 mm suitable for street light incoming and outgoing cables up to 10 sqmm 4 core (with terminal) & MCB SP 6 Amp, including nuts,bolts,cable glands & MS clamps fixed to pole all as directed. Make:Hensel cat part no KF5100 or it's equivalent in Havells/Sintex/
Schedule of Credit
M/S AKC ENTERPRISE
HAMZA CONSTRUCTION CO
N.V.ENGINEERING
R.K.ENGINEERING ASSEMBLE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .