| 1 | L1₹22.2 LAccepted-Finance | ₹22.2 L | L1 | Accepted-Finance Accepted being L1 bidder |
| 2 | L2₹22.6 L+₹41,215 (1.86%)Rejected-Finance | ₹22.6 L+₹41,215 (1.86%) | L2 | Rejected-Finance Rejected being other than L1 bidder |
| 3 | L3₹24.4 L+₹2.2 L (9.90%)Rejected-Finance 42 B INDRA NAGAR SRINAGAR J K 190004 | SRINAGAR | SRINAGAR | J K | 190004 | ₹24.4 L+₹2.2 L (9.90%) | L3 | Rejected-Finance Rejected being other than L1 bidder |
| 4 | L4₹26.5 L+₹4.2 L (19.1%)Rejected-Finance | ₹26.5 L+₹4.2 L (19.1%) | L4 | Rejected-Finance Rejected being other than L1 bidder |
| 5 | L5₹28.6 L+₹6.4 L (28.6%)Rejected-Finance | ₹28.6 L+₹6.4 L (28.6%) | L5 | Rejected-Finance Rejected being other than L1 bidder |
| Sl No | Description | Qty | Unit | ORISON ENTERPRISES L1 | M/S ZENITH TRADE LINK L3 | M/S SMA and SONS CONSTRUCTIONS L4 | M/S LATIF AHMED MIR L2 | M/s Nasir Rasool Dar L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the entire Split AC unit from its current location, unscrewing the front cover, and removing any packing material. The unit is then thoroughly cleaned with an electric blower and a cleaning agent like Collin. After cleaning, test the unit to identify and replace any defective parts, then reinstall it, including sealing with thermocol or packing material. If unserviceable spare parts changed, they will be measured and paid for separately. Special care must be taken to avoid damaging the PCB and other electronic parts, if damaged, the contractor must repair or replace it at their own cost. | 120 | Each Job | 550 ₹66,000 | 600 ₹72,000 | 630 ₹75,600 | 1,500 ₹1,80,000 | 300 ₹36,000 Lowest |
| 2.00 | All as per item No. 1.00 above but for Window Type AC's of 1.5/2.0 ton capacity. | 3 | Each Job | 250 ₹750 Lowest | 350 ₹1,050 | 400 ₹1,200 | 1,500 ₹4,500 | 300 ₹900 |
| 3.00 | Supply and wrapping of insulation on and around suction and discharge copper tubing of size 3/8" and 5/8" with 6 mm thick flexible corrugated thermocool, heat resistant, for split type AC complete all as specified and directed. | 100 | RM | 15 ₹1,500 Lowest | 20 ₹2,000 | 25 ₹2,500 | 100 ₹10,000 | 75 ₹7,500 |
| 4.00 | M&L to identify and rectify gas leakage in Split/window AC of 1.5/2 TR including detecting the source of leakage, brazing the affected part to fully seal the leak, and charging refrigerant gas as needed (cost for gas to be measured & paid separately). | 50 | Each Job | 200 ₹10,000 | 250 ₹12,500 | 265 ₹13,250 | 500 ₹25,000 | 75 ₹3,750 Lowest |
| 5.00 | S&F of thermostat for window type AC of capacity 1.5/2 Ton complete all as specified and directed by Engineer-in-Charge . | 2 | Each | 100 ₹200 | 140 ₹280 | 160 ₹320 | 500 ₹1,000 | 75 ₹150 Lowest |
| 6.00 | S&F of blower fan motor suitable for cooling unit of Window type ACs/cooling unit (Indoor unit) of Split AC of capacity 1.5/2.0 TR complete all as specified and directed. | 50 | Each | 650 ₹32,500 Lowest | 700 ₹35,000 | 800 ₹40,000 | 780 ₹39,000 | 1,800 ₹90,000 |
| 7.00 | S&F of Condensing Fan Motor as per Existing Make and Capacity For 1.5/2 Ton Window/Split Type AC Complete all as specified and directed by Engineer-in-Charge. | 50 | Each | 700 ₹35,000 Lowest | 800 ₹40,000 | 900 ₹45,000 | 800 ₹40,000 | 1,500 ₹75,000 |
| 8.00 | S&F of condensing coil as per existing make for 1.5/2.0 Ton capacity split AC as directed by Engineer-in-Charge. | 5 | Each | 225 ₹1,125 Lowest | 300 ₹1,500 | 350 ₹1,750 | 600 ₹3,000 | 500 ₹2,500 |
| 9.00 | S&F PCB for window type AC operating at hot and cold mode of capacity 2.0 Ton/1.5 Ton , compete all as specified and as directed. | 2 | Each | 1,700 ₹3,400 | 2,000 ₹4,000 | 400 ₹800 Lowest | 1,500 ₹3,000 | 5,000 ₹10,000 |
| 10.00 | S&F PCB for split type AC operating at hot and cold mode of capacity 1.5/2 Ton, compete all as specified and as directed. | 25 | Each | 2,500 ₹62,500 | 2,900 ₹72,500 | 2,900 ₹72,500 | 2,000 ₹50,000 Lowest | 4,000 ₹1,00,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
8 Aug 2026, 6:00 pmClosed
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR C/o 56 APO PIN-937208
REPAIR/ MAINT DEEP FREEZER, REFRIGERATOR AND AIR-CONDITION SYSTEM AF STN AWANTIPUR
2026_MES_777980_1
GE (AF) AWA-17/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE (AF) AWANTIPUR
₹60,000
Yes
7 Sept 2026
11 Jul 2026
10 Aug 2026
11 Jul 2026
8 Aug 2026
25 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down the entire Split AC unit from its current location, unscrewing the front cover, and removing any packing material. The unit is then thoroughly cleaned with an electric blower and a cleaning agent like Collin. After cleaning, test the unit to identify and replace any defective parts, then reinstall it, including sealing with thermocol or packing material. If unserviceable spare parts changed, they will be measured and paid for separately. Special care must be taken to avoid damaging the PCB and other electronic parts, if damaged, the contractor must repair or replace it at their own cost. | 120 | Each Job | - | - |
| - | All as per item No. 1.00 above but for Window Type AC's of 1.5/2.0 ton capacity. | 3 | Each Job | - | - |
| - | Supply and wrapping of insulation on and around suction and discharge copper tubing of size 3/8" and 5/8" with 6 mm thick flexible corrugated thermocool, heat resistant, for split type AC complete all as specified and directed. | 100 | RM | 4 | ₹400 |
| - | M&L to identify and rectify gas leakage in Split/window AC of 1.5/2 TR including detecting the source of leakage, brazing the affected part to fully seal the leak, and charging refrigerant gas as needed (cost for gas to be measured & paid separately). | 50 | Each Job | - | - |
| - | S&F of thermostat for window type AC of capacity 1.5/2 Ton complete all as specified and directed by Engineer-in-Charge . | 2 | Each | - | - |
| - | S&F of blower fan motor suitable for cooling unit of Window type ACs/cooling unit (Indoor unit) of Split AC of capacity 1.5/2.0 TR complete all as specified and directed. | 50 | Each | - | - |
| - | S&F of Condensing Fan Motor as per Existing Make and Capacity For 1.5/2 Ton Window/Split Type AC Complete all as specified and directed by Engineer-in-Charge. | 50 | Each | - | - |
| - | S&F of condensing coil as per existing make for 1.5/2.0 Ton capacity split AC as directed by Engineer-in-Charge. | 5 | Each | - | - |
| - | S&F PCB for window type AC operating at hot and cold mode of capacity 2.0 Ton/1.5 Ton , compete all as specified and as directed. | 2 | Each | - | - |
| - | S&F PCB for split type AC operating at hot and cold mode of capacity 1.5/2 Ton, compete all as specified and as directed. | 25 | Each | 4 | ₹100 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tender17.pdf
Tender Documents • 1.83 MB
BOQ_871318.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .