Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.8 LAccepted-AOC | L1 | Accepted-AOC 1st Lowest and reasonable | |
| 2 | L2₹77.6 L+₹7.9 L (11.4%)Rejected-Finance 1108 CHOTA BAZAR MHOW MP PIN 453441 | MHOW | INDORE | MADHYA PRADESH | 453441 | L2 | Rejected-Finance 2nd Lowest | |
| 3 | Rejected-Technical 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | - | Rejected-Technical Due to the firm is enlisted in E class which is two class below than required class C |
Tender Value
₹72 L
EMD Value
₹1.3 L
Closing Date
21 Apr 2025, 6:00 pmClosed
CWE MHOW
HQ CWE MHOW, MHOW CANTT, MHOW (M.P)-453441
SPL REPAIR TO 11 KV HT LINE RMU SUBSTATION INTER CONNECTION APFC PANEL STANDBY HT CABLE AND SPECIAL REPAIR TO INDOOR 33 KV/11KV VCBS RMUS FOUR POLE STRUCTURE AND TWO POLE STRUCTURE UNDER GE MCTE MHOW
2025_MES_702317_1
CWE/MHOW/73(T) OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HQ CWE MHOW
Please refer tender docs
8 documents required · 8 mandatory
₹1,000
GE MCTE Mhow
₹1.3 L
20 Jun 2025
22 Mar 2025
23 Apr 2025
22 Mar 2025
21 Apr 2025
7 Apr 2025
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in deep and getting out for laying of cable/ pipes etc including forming bottom surfaces to the required level/slope complete all as specified and directed
Returning , filling in includiing spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in soil comlete all as specified and directed
Removing surplus excavated to a distance not exc 50 mtr and depositing where directed at level not exc 1.5mtr above the starting point complete allas specified and directed.
Material and labour for approved river sand cushioning for under ground cable in trenches 8 cm before laying and 15 cm after laying of cable and punned thickness of sand shall be measured and paid for 18 cm only after punned/consolidated thickness complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type-2, flat, size 450mm x 180mm x 40mm, ISI marked, laid flat across the cable length for cable protection embossed with HT 11 KV electric on the top surface complete all as specified and directed.
M&L for bricks slightly over burnt (kiln burnt), modular bricks, best quality, locally available,laid flat, dry, laid in trenches along the length of cable transversally with width equal to length of brick for cable protection complete all as specified and directed.
Supply and laying Galvanised iron pipe "light grade" 100 mm bore in trenches, under floors, roads, along poles for protection of cable with all necessary fittings, including sealing ends complete. Make :- Jindal ,Tata, Swastik
Supply and laying Galvanised iron pipe "light grade" 80 mm bore in trenches, under floors, roads, along poles for protection of cable with all necessary fittings, including sealing ends complete all as specified and directed. Make :- Jindal ,Tata, Swastik
Taking out old unserviceable underground HT cable 11 KV armoured with aluminium conductor of any size from trenches, walls, road, footpath or ducts and making good after taking down complete all as specified and as directed.
Supply , laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) conforming to latest relevant IS with multy stranded aluminium conductor, 11000 volts grade of size 3 core 95 mm cable laid in trenches/ducts/under plinth floor passing through pipe etc, fixed on wall complete all as specified and as directed.
Supply , laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) conforming to latest relevant IS with multy stranded aluminium conductor, 11000 volts grade of size 3 core 120 mm cable laid in trenches/ducts/under plinth floor passing through pipe etc, fixed on wall complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade (E) cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and directed. Make : 3 M/Dension/M seal
Supply and fixing cable jointing kit for 11 KV (E) grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable complete all as specified and directed. Make : 3 M/Dension/M seal
Supply and fixing cable jointing kit for 11 KV (E) grade cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core 120 sqmm XLPE armoured aluminium conductor cable complete all as specified and directed. Make : 3 M/Dension/M seal
Supply and fixing cable jointing kit for 11 KV (E) grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core 120 sqmm XLPE armoured aluminium conductor cable complete all as specified and directed. Make : 3 M/Dension/M seal
Supply and fixing cable jointing kit for 11 KV (E) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable complete all as specified and directed. Make : 3 M/Dension/M seal
Material and Labour for boring holes under the road/pavement/hard standing with the help of trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 100mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as specified and directed. (The cost of HDPE pipe shall be deemed to be included in quoted rate).
Supply and fixing cable route indicator, made of MS sheet of size 200 mm x 150 mm x 3 mm thick, spot welded with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-2( using 40mm graded crushed stone aggregate) block 30cm x 30cm x 40cm in ground including one coat of synthetic enamel black paint over one coat of red oxide zinc chrome primer and writing with white paint showing size of cable HT complete all as specified & directed .
S&F in replacement Solar LED light fitting 24 watt with high efficiency All-In-One Solar street light Mono Crystel, Lithium Ferro Phosphate battery with in-built BMS technology,MPPT Solar Charge controller and aluminium extruded body with PIR motion sensor automatically control the dimming and brightness of light, battery capacity 30AH,IP65, temp 5700K complete all as directed. Make : Havells Cat Part No LHSTAKU7CBAF024/Bajaj/Eveready
Taking down old unserviceable capacitor of any capacity and replace with new Duca Power XD capacitor, withstand Harmonic overloads upto 4 Amp Max current, low losses 0.2 watt/KVAR, three phase, temperature range (-)25 degree centigrate to 70 degree centigrate of the following rating :- Make : Neptune or equivalent
Taking down old unserviceable power contactor of any capacity and replace with new contactor three phase of the following sizes:- Make : Havells or equivalent
Contactor for capacitor heavy duty 3 pole with AC coil 1NO 0NC 25 Amps.
Contactor for capacitor heavy duty 3 pole with AC coil 1NO 1NC 40 Amps.
Contactor for capacitor heavy duty 3 pole with AC coil 2NO 2NC 95/100 Amps.
Taking down old unserviceable Harmonic Block Reactors for Detuned System for any capacity and replace with new Harmonic Block Reactors for Detuned System for 50 KVAR capacitor, three phase copper wound with an iron core and air gap,highest quality material , high class insulation,filtering factor 7% complete all as specified and directed.
Sppply & Laying, armoured, electric copper cable of size 25 sqmm 1 core with multi stranded copper conductor, 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes & making necessary connection complete all as specified and directed. Make : Polycab/Havells/Indo Asian.
S&F in replacement of copper lugs including testing complete of following sizes :-
10 mm dia
25 mm dia
Taking down old UNSV fuse assembly any capacity and replaced with new DIN fuse base assembly fixed type suitable for 100 Amps complete all as specified and directed. Make : Havells cat part No IHUC000100 or equivalent
Taking down old UNSV fuse any capacity and replaced with new DIN type HRC fuse 415 volts suitable for 100 Amps complete all as specified and directed Make : Havells cat part No IHHCD11100 or eqivalent
Spply only multistranded copper conductor, flame retardant , low smoke (FRLS), PVC insulated & outer sheathed Al- Mylar tape individual and overall shielded unarmoured instrumentation control cable of size 2.5 sqmm 8 core for item no 27 to 32 .
Supply & Laying XLPE insulated, armoured, electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes including provision of necessary lugs and glands & making necessary connection complete all as specified and as directed, of the following sizes:-
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
M&L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI strip 32x6mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation in disintergratedand hard soil and 20mm dia GI pipe with funel for watering PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge.
Taking down old UNSV AMF panel all as directed by Engr-in-Charge
Taking out old unserviceable underground LT cable armoured with aluminium conductor of any size from trenches, walls, Road, footpath or ducts and making good after taking down complete all as specified and as directed.
TSupply, installation, testing and commissioning of 11 KV Outdoor type RMU extensible IP54 floor mounted with internal copper bus bars, consisting of fixed type Motorised Vacuum Circuit Breakers-02 Nos as incomer, and fixed type Motorised Vacuum Circuit Breakers-02 Nos as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple inter connections & sealed for life robotically for three sides and one side manual welded non magnetic / non ferrite / stainless steel tank Grade 304 of minimum 2.5 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 & 603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200 complete all as specified.(AWC Area) (Make: ABB/Siemens/ Schnieder, Areva)
The unit shall have front cable entry for case of installation. RMU should be complete with all accessories such as terminal boots, VPIS, cable supports all front cable terminations, mechanical indications ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC60120. The unit shall include the following with all necessary standard fitting required at site. RMU should be tested for an internal arc fault of 21KA for 1 sec as per IEC62271-200 and paint shade and thickness should be as per AIS 632 IS – 5 complete all as specified and as directed. The outer enclosure shall cover the full length of the switch gear, to ensure IP55 protection for full door covering of complete switchgear.
(a) 2Nos. Incomer & 2 Nos outgoing :- (i) 630A Vacuum Circuit breaker module for making and breaking of fault current along with Earth switch of full making capacity. (ii) Short time breaking current-21 KA/ 3 sec Making capacity-52.5 KA (iii) Internal ARC-21KA/1 sec (iv) Nominal operating gas pressure – 1.3(minimum) bar abs (v) Power frequency withstand voltage-28KV (vi) Impulse withstand voltage-75KV (vii) Outdoor Enclosure –IP54 (viii) Front covermechanism-IP2X (ix) Cable covers – 3X (x) Stored energy mechanism for motor operation -24VDC (xi) Cable box for front termination of the cable suitable upto 3 core 400 Sqmm, 11KV XLPE cable (xii) Operation counter (xiii) Self-powered microprocessor based relay (3 O/C & E/F) with RS485 port and with standard setting –ADR241S (xiv) Digital multifunction meter (A,V,KW,F,PF) with RS 485 port type Rishabh/ Elmeasure (not applicable for bus coupler VCB) (xv) Protection CT-50-100/1A, CI-5P10, 2.5VA burden (not applicable for bus coupler VCB) (xvi) Metering CT-50-100/1A, CI-10, 2.5 VA burden(not applicable for bus coupler VCB) (xvii)Suitable site replaceable cables bushings (xviii) Arc proof cable covers with self interlocking mechanism between doors, earth switch, disconnector &VCB (xix) Capacitive voltage indication fixed type system (xx) Mechanical indication for breaker ON, OFF,EARTH< TRIP, spring charged- discharged
b) Direct cable module -1 No :- (i) 630A vacuum circuit breaker module (ii) Short time current -21KA/3 sec (iii) Internal arc -21KA/1sec (iv) Nominal operation gas pressure -1.3(minimum) bar abs (v) Power frequency withstand voltage -28KV (vi) Impulse withstand voltage -75KV (vii) Outdoor enclosure –IP54 (viii) Front cover mechanism –IP2X (ix) Cable cover -3X (x) Stored energy mechanism for motot operation -24VDC (xi) Cable box for fornt termination of the cable suitable upto 3 core 400Sqmm, 11KV XLPE cable (xii) Suitable site replaceable cable bushings (xiii) Arc proof cable covers with self interlocking mechanism between doors, earth, switch, disconnector &VCB (xiv) Capacitive voltage indication fixed type system (xv) Mechanical indication for breaker ON, OFF, EARTH, TRIP, Spring charged - Discharged
(C) Bus Connected PT Unit-1No for Metering consisting of following :- (i) Type M: Air insulated metering module 12KV, 630A, 21 KA for 1 sec -3 voltage transformers of the ratio 11KV/V3/ 110 V/V3, 50 VA, class 1.0 with HT fuses von primary side and MCB on secondary side. (ii) 1 LED illumination (iii) 1 space heater with thermostat (iv) RYB phase indications (v) 1 no digital voltmeter (d) 2x12 V battery with battery charge with suitable burden for motor operation input 230V AC & output 24 V DC. (e) Capacitive voltage indication fixed type VPIS 9-15 KV (f) Necessary interlocking arrangement for safety and operations (g) One no. operation handle for manual operation (h) One no. manometer (i) Safety interlocks shall be provided as per relevant IEC/IS standards and manufacturers direction. (k) Above switchgear shall conform to all relevant IEC/IS standards (l) Manual operation of vacuum circuit breaker should be possible without dismantling the motor from RMU. The motor should be filled in such a way that it should not be outside front covers of RMU. (m) Operation and instruction manual with drawing -01 set
NOTE :- Rate quoted by the firm for this item should include the cost of the following :- (i) PCC work/ any civil work for foundation required for errection of VCB and other accessories all as standard norms. (ii) contractor shall submit type test certificate to the Engg-in- charge/GEfor approval for placing the order. (iii) The contractor will be submitted the NABL accredited lab test reports of the RMU’s in original and the same shall be produced well before claiming RAR payment of the RMU. (iv) RMU shall be inspected by inspecting officer nominated by Accepting Officer for testing and inspection at manufacturers factory and all routine test pertaining to IS shall be carried out before dispatching of RMU. (v) Pre commissioning SEI inspection shall be carried out after installation of RMU.
Supply and fix Dew guard of size 150x150x2 mm make HENSEL cat part no HDE 150 or equivalent make including taking down old unsv heater complete all as specified and directed.
Disconnect of all connection of HT supply (11 kVUG Cable) from three way RMU foundation and PCC work from RMU and take out RMU by suitable hydraulic crane and RMU to desired location and reconnect, testing , commissioning the same all as specified and directed by Engr-in-charge. Note:- Rate of Earth work and PCC for foundation is deemed to included in rate quoted.
Supply and fix in replacement of faulty over current & earth fault Relay and taking down old unsv relay of make L&T Cat No MC61A or equivalent make all as specified and directed by Engr-in-charge.
m/s bansal construction (BID ID -3285395)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .