Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.3 LAccepted-AOC | L-1 | Accepted-AOC LOW RATE | |
| 2 | L-2₹13.3 L+₹3.0 L (29.2%)Rejected-Finance 582 A KANPUR ROAD NEAR MAUSAM VIBHAG NEW BEHESA DISTT LUCKNOW UTTAR PRADESH 266012 | 266012 | L-2 | Rejected-Finance HIGH RATE | |
| 3 | L-3₹14.7 L+₹4.4 L (42.4%)Rejected-Finance 180 10 STREET NO 10 HARPAL NAGAR NEAR TRIVENI MANDIR BHATTI ROAD BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L-3 | Rejected-Finance HIGH RATE | |
| 4 | L-4₹15.2 L+₹4.9 L (47.5%)Rejected-Finance 613 GANPATHI APARTMENTS SECTOR 9 DWARKA SOUTH WEST DELHI DELHI 110075 | DELHI | SOUTH WEST DELHI | DELHI | 110075 | L-4 | Rejected-Finance HIGH RATE | |
| 5 | L-5₹15.5 L+₹5.1 L (49.7%)Rejected-Finance 102 SAI PRASAD BUILDING 1ST FLOOR BHANDARWADA OPP CROMA SHOWROOM SION EAST MUMBAI 400 022 | MUMBAI | MAHARASHTRA | 400022 | L-5 | Rejected-Finance HIGH RATE |
Tender Value
₹17.7 L
EMD Value
₹35,500
Closing Date
21 Feb 2022, 5:00 pmClosed
ANIL KUMAR SM (E-C)
ANIL KUMAR , SR. MANAGER (E-C), M.P. AIRPORTS, UDAIPUR
Water proofing and repairs of roof of residential quarters at M.P Airport, Udaipur (Phase-2)
2022_AAI_102956_1
AAI/UDR/SM(E-C)/W-114/21-22
Open Tender
Civil Works
Item Rate
90 days
M.P. AIRPORTS
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,120
₹35,500
9 May 2022
1 Feb 2022
23 Feb 2022
1 Feb 2022
21 Feb 2022
1 Feb 2022
1 Feb 2022 - 15 Feb 2022
Amount
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
Dismantling old plaster, old water proofing layer or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Shiffing of tank of capacity upto 500 litre from one place to other place on roof for water proofing work on roof complete as directed by Engineer-in-charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia Pipes
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand)
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
JAMAN LAL
M/S MITTAL CONSTRUCTION COMPANY
Singh Associate
RAJESH INFRASTRUCTURE PVT LTD
MICRO LEAKAGE CARE PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .