Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.9 LQualified Make: Koel Green Electro
Model: KOEL GREEN KG1-180WS3 WITH PART NO. 318161-3212B 20 23 BHAGWANPUR RAIPUR SAHKARI AUDYOGIC KSHETRA HARIDWAR UTTARAKHAND 247661 | HARIDWAR | UTTARAKHAND | 247661 | Make: Koel Green Electro
Model: KOEL GREEN KG1-180WS3 WITH PART NO. 318161-3212B | L1 | Qualified | |
| 2 | L3₹19.5 L+₹4.5 L (30.4%)Qualified Make: CUMMINS
Model: Cummins, QSB6.7-G14 1 206 54 S D MANDIR MARKET SADAR BAZAR S D MANDIR MARKET SADAR BAZAR DELHI CANTT NEW DELHI | Make: CUMMINS
Model: Cummins, QSB6.7-G14 | L3 | Qualified | |
| 3 | Qualified Make: KOHLER
Model: KOHLER-KDG0180P1 | Make: KOHLER
Model: KOHLER-KDG0180P1 | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
27 May 2018, 5:00 pmClosed
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 180 180 No of Phase - threephase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - BIS license No
if applicable - - Type of Engine cooling Liquid Cooled liquidcooled Type of governer Electronic electronic Class of governer A2 a2
a1 Number of cylinders (nos) 6 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500 Overload capacity for 10 - 1/4 one hour for every 11 hours continuous running at full load (%) Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 24 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 180 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 95 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 1 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF Manual
AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
1.8
2
1.2 Thickness of Foam 82 - Density of Foam for sound insulation 35 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 2 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number and date(Engine) - - 2/4 Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation withinstallation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Harish Kumar 110001
Ministry of road transport & Highways
Room No. 236
Transport Bhawan
Parliament Street
New Delhi 110001 1 30 EMD Required No ePBG Required No
75223
GEM/2018/B/10730
diesel generators- DG Sets
30 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 180 180 No of Phase - threephase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - BIS license No | - | - | - |
| if applicable - - Type of Engine cooling Liquid Cooled liquidcooled Type of governer Electronic electronic Class of governer A2 a2 | - | - | - |
| a1 Number of cylinders (nos) 6 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500 Overload capacity for 10 - 1/4 one hour for every 11 hours continuous running at full load (%) Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 24 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 180 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 95 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 1 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF Manual | - | - | - |
| AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 Thickness of Foam 82 - Density of Foam for sound insulation 35 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 2 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number and date(Engine) - - 2/4 Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation withinstallation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Harish Kumar 110001 | - | - | - |
| Ministry of road transport & Highways | - | - | - |
| Room No. 236 | - | - | - |
| Transport Bhawan | - | - | - |
| Parliament Street | - | - | - |
| New Delhi 110001 1 30 EMD Required No ePBG Required No | - | - | - |
Exempted
27 May 2018
9 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_75223.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .