Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹17.7 L+₹1.8 L (11.1%)Rejected-Finance AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L2 | Rejected-Finance Other than lowest bids | |
| 3 | L3₹19.1 L+₹3.2 L (20.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bids |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
27 Jun 2020, 6:00 pmClosed
CWE Jalandhar Cantt
HQ CWE kabir Road Jalandhar Cantt Pin-144005
Please refer tender documents
2020_MES_344669_1
CA NO CWE/JAL/W-04/2020-21 8320/04/E8
Open Tender
Civil Works
Item Rate
180 days
Jalandhar Cantt
Class E Category a(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
Garrison Engineer West JRC
₹42,000
Yes
20 Jul 2020
14 May 2020
29 Jun 2020
14 May 2020
27 Jun 2020
28 May 2020
Amount
Dismantling of brick tiles single layer as in roof covering complete all as specified
Demolition of mud in roofs any thickness including plastering and leeping(whether full thickness removed or only a part thereof) all as specified.
Material and labour for 3mm thick superior Atactic poly propylene modified polymeric membrane waterproofing treatment of weight not less than 3.6 Kg per sqm with properties of high penetration and the centre core consisting of 90 micron high Molecular-High Density polyethylene (HMHDPE) film consisting of five layers. The superior multi polyplus is to be laid after preparing the surfaces by cleaning thoroughly to achieve a smooth surface over and including a coat of bitumen primer @ 0.30 Litre per sqm over a coat of hot applied Blown Bitumen of grade 85/25 @ 1.2 kg per sqm. The overlaps between super multi polyplus are minimum 10cm seam in width/lengthwise complete all as specified and all as per manufacturer’s directions.
M & L for 10mm thick rendering on concrete surfaces finished even and smooth without using extra cemet in cement mortar 1:3 as in roof/sunken floors and using WPC 3% by wt of cement complete all as specified Note : WPC shall be measured and paid separately under respective item.
M & L for brushing neat cement slurry with 3kg of cement per sqm complete all as specified.
M & L for PCC Padding with cement concrete type B-I (1:2:4) 20mm graded aggregate to bring top surface of slab in slope complete all as specified
M & L for 40mm thick brick tiles laid on bedding layer of CM 1:3, 15mm thick and joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement over APP membrane complete all as specified
All as per item No 7 above but except tiles complete all as specified
M & L for flush pointing in CM 1:3 to brick tiles laid flat in roof or paving incuding raking out joints complete all as specified and directed.
Taking up or down steel tubing and connections 15mm bore and connections, including cleaning for refixing or removing to store yard complete all as specified and directed,
Taking up or down steel tubing and connections 20 mm bore and connections, including cleaning for refixing or removing to store yard complete all as specified and directed,
S&F 15mm bore galvanized iron tubes medium grade with all fitting and fixed complete to walls, ceiling or laid in floor complete all as specified.
All as per description of item No 12 above but for 20mm bore tube complete all as specified
Dismentling existing water tanks of capacity exc 500 but not exc 1000 ltr and removing complete all as specified and directed.
S&F 1000 ltr rotational moulded polythylene water storage tank double layer (Cylindrical vertical with closed top) ISI marked hosted and fixed in position complete all as specified.
S&F 20mm bore ball valve brass high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete all as specified.
S&F 20mm Gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified.
Supply only Integral water proofing compound as in roof/sunken conforming to IS-2645 complete all as specified.
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer E-Board Classic to be fixed with GI powder coated grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mm duly suspended with 6mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size including taking down complete all as specified and as directed.
Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excluding precast concrete articles complete all as specified.
Material & labour for brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar (1:6) complete all as specified and directed.
All as per item no 21 here-in before but using old serviceable bricks retrieved from demolition of existing brick work including cleaning of bricks complete all as specified and directed.
M&L for half brick thick wall using with sub class 'B' old size bricks straight or curved on plan to any radius with old size brick thick walls built in cement mortar 1:4 complete all as specified.
Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area not exc 1.5 Sqm each all as specified.
All as per item No. 24 above but area exc 1.5 Sqm and not exc 4 Sqm each complete all as specified.
S&F anodised aluminium frame for doors, windows, partitions ,ventilators with one or more rebates including joining cleat for fixing etc complete all as specified.
S&F Anodised aluminium door shutters ,aluminium section weighing 0.55 kg/m including necessary joining cleats ,glazing clips, rubber neoprene packing, handles 2 Nos in each door, butt hinges, anodised aluminium snap beading screws etc complete all as specified.
S&F sheet glass 4.8 mm thick ordinary quality to be fixed in Alumimium frame work in square exc 0.5 sqm in each pane complete all as specified.
S&F door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified.
M&L for hasp and staple safety type aluminum anodised 75mm size with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified
S&F floor door stopper aluminum alloy body anodized with hard drawn steel spring of overall length 150mm complete all as specified.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks complete all as specified.
Taking down cement plaster of any description, any thickness /dado/Skirting/ including raking out joints hacking for key scrubbing down with water complete all as specified.
M&L for 15 mm thick cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cement complete all as specified
M&L for 15 mm thick cement mortar 1:4 on brick or concrete surface finished even and smooth without using extra cement complete all as specified
M&L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper with one coat birla putty on plastered surface preparatory to distempering complete all as specified.
M&L for preparing new plastered or unplastered wall surfaces and applied two coats of cement base paint over one priming coat all as specified and directed by Engr-in-charge.
Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified.
M & L for rolled mild steel section as in plate girders, or single stanchions, build up of one beam or channel section with flange plates, caps bases, Splices, angle brackets, cleats and other connections complete all as specified.
S&F rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates. conforming to grade Fe-410-W complete all as specified and directed by EIC.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified.
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing) and disposal of rubbish outside Defence land complete all as specified.
Demolition of cement concrete in ground floor and paving of any description ( below or above ground level) complete all as specified.
M&L for 25 mm thick cement concrete type B-1, 1:2:4 (20 mm graded aggregate) to receive the top layer of tiles complete all as specified.
M & L for vitrified ceramic tiles light shade 10 mm thick (Square/rectangular) polished and area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified.
All as per description of item No. 45 above but in skirting/dado over and including 10mm thick rendering as backing coat of CM 1:4 complete all as specified.
M&L for complete removal of existing treatment of wall surfaces and applying two coats of oil bound distempering over one coat of birla white putty all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing treatments on wall surfaces and applied two coats of cement base paint over one coat of primer all as specified and directed by Engr -in-charge.
Taking down carefully existing point wiring aluminum/ copper conductor for light or fan or socket or power etc on wooden batten or in conduit including fittings and accessories like switches, holders, sockets, lights fitting, regulator, wooden board and making good disturbed portion to match with existing complete all as specified and directed.
Material & labour for concealed point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated and unsheathed cable 1100 volts multistranded, copper conductor cable (FRLS) drawn through and including PVC concealed conduit not less than 20mm dia bore medium grade (ISI marked) and accessories like bends, tees, junction boxes etc, fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire including sunken type pressed steel terminal boxes and plastic laminated white/ coloured top sheet cover 3.0 mm thick , for one light point/call bell point controlled by one way switch complete all as specified and directed.
All as per item No. 50 above but one 5 pin socket outlet 5 amps on independent board with other switches, complete all as specified and directed. .
All as per item No. 50 above but one 5 pin socket outlet 5 amps on same board , complete all as specified and directed. .
All as per item No. 50 above but with 2.5 sqmm multistranded copper conductor FRLS cable with 2.5 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board, complete all as specified and directed.
All as per item No. 50 above but with 4 sqmm cable for AC on independent board, complete all as specified and directed.
Supply and fix switch piano flush button type, 5 Amps, 230V AC, single pole, one way complete all as specified and directed
S&F socket outlet 5 pin, 5 amps, flush type, complete all as specified and directed. .
Supply and fix switch socket combination outlet universal type multi purpose 6 pin 5/15 Amp flush type 230/250 volts AC with ISI marked on independent board complete all as specified.
Supply and fix SPN sheet metal enclosure with two pin and earth plug and socket complete with one MCB 20A all as specified.
Taking down u/s sub main wiring of any size complete and making good disturbed surface of walls/roof etc all as specified.
Material & labour for submain wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated multistranded copper conductor cable (FRLS) drawn through and including 20 mm dia. PVC rigid concealed conduit and conduit accessories and 4 sqmm PVC insulated copper wire for continuous earth continuity conductor all as specified and directed by Engr-in-charge. Note : Two run of 4 sqmm cable and one run of 4sqmm along with 20mm dia PVC conduit will be measured as one unit.
Supply and Fix batton holder, insulated body with 5 watt LED bulb complete all as specified and directed.
Supply and fixing stepped type electronic fan regulator and connecting up complete 230/250 volts as directed by Engr-in-charge.
Supply & fix in replacement LED batten light fitting 22W (double side) retrofit including LED lamp with 2100 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures box type with retrofit LED rod 22 watt and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed. Make :Havells cat part No. LUMLINEPLUSBS22WLED865SPCSS or equivalent as mentioned in appendix 'B'
Supply & fix in replacement LED street light fitting 20W including LED lamp pressure die cast aluminium IP66 with surge protection device of 10KV, IK7 LED (SEOUL) 6500K and connecting electrical to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed incl bracket and fixing clamps. Make :Havells cat part No. ENDURAPEARLSL20WLED757SASYTOPC or equivalent as mentioned in appendix 'B'
Supply and fix ceiling rose surface bakelite 65 x 50 mm three terminal PVC / Polycarbonate isolated body complete all as specified.
S & F in repair 34watt 2x2 LED PLUTO NEO ceiling fitting light fitting atra modern designed LED luminaire which provides soft-light and glare free symetrical illumination suitable for armstrong/Grid Celing including Bracket nuts bolts washer as required for fixing complete all as specified and directed. Make : Cat Part No PLUTONE02X2PLR34WLED840S or equivalent as in Appx 'B'
Taking down DBs/ main switch board of any size and making good disturbed surface of wall/floor complete all as specified and directed.
Supply and fix sheet metal enclosures for DB's with 200 Amp rated bus bar double door class IP-43 epoxy coated inside and outside 4 way TPN 440 volts with incoming/outgoing connection through proper size of lugs complete all as specified and directed
Supply and fix isolator TPN 63 Amps 415V complete all as specified and directed.
Supply and fix DB SPN 8 way double door for MCB 240 Volts with 200 Amps rated bus bar complete all as specified and directed.
Supply and fix isolator B Curve SPN upto 40 Amps 240 V complete all as specified and directed.
M & L for MCB B Curve SP 6 to 32 Amps complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of theplate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4mm dia connected to earth plate earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continuous earth wire on pole, testing the earthing after completion complete all as specified and directed. Note :- (I) Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit (II) PCC chamber shall be (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways complete all as specified and directed.
Supply and lay GI tubing light , grade 40mm bore with all necessary fittings laid in trenches under road crossing in floors complete all as specified and directed.
Taking down XLPE insulated armoured heavy duty electric cable with aluminium conductor complete all as specified and directed.
Supply and laying XLPE insulated, armoured heaby duty electric cable with aluminium conductor 1100 volts grade cross sectional area 4 core 50 sqmm on floor/wall including lugs & fitting for fixingcomplete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning filling in layers including leveling watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
Supply and spread river sand in trenches as cable cushioning 8 cm below the cables and 15cm aboe the cable all as specified and directed
Removing excavated material n not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
Supply and lay burnt bricks sub Class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed
Supply and fixing of new generation, post top, energy saving spun aluminium landscape luminaries with high power 35W suitable for pole dia 76mm conforming to IP65 Ruby (Clear) all as specified and directed. Make: Havells cat part No. RUBYPT35WLED757PSYMTOPC or equivalent as in Appx 'B'
siddharthenterprises
G S TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .