Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹2.0 L+₹421.26 (0.21%)Accepted-Finance 1 23 10 ROJA FIRST STREET ALAMEEN NAGAR SURVEYOR COLONY MADURAI 625 007 | MADURAI | TAMIL NADU | 625007 | L2 | Accepted-Finance L2 | |
| 3 | L3₹2.1 L+₹4,046.22 (2.01%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | L4₹2.1 L+₹6,951.38 (3.45%)Accepted-Finance | L4 | Accepted-Finance L4 |
Tender Value
Refer Docs
Closing Date
13 Feb 2021, 3:00 pmClosed
PRINCIPAL
GOVERNMENT POLYTECHNIC COLLEGE, KOODUVELI, MUTHIAH POLYTECHNIC COLLEGE CAMPUS ANNAMALAI NAGAR, CHIDHAMBARAM 608001
SUPPLY OF CEM LAB EQUIPMENTS
2021_DoTE_194010_1
1035/B2/2021 SUPPLY OF CEM LAB EQUIPMENTS
Limited
Electrical Goods/Equipments
Supply
10 days
CHIDHAMBARAM
REFER BOQ
2 documents required · 2 mandatory
₹0
Exempted
17 Feb 2021
5 Feb 2021
15 Feb 2021
5 Feb 2021
13 Feb 2021
5 Feb 2021
5 Feb 2021 - 13 Feb 2021
Supply of CONTROL OF ELECTRICAL MACHINES LAB EQUIPMENTS (for technical specifications refer NIT)
PLC Trainer Kit Allen Bradley Micro810 Controller with 6 digital inputs and 4 digital outputs and 2 analog inputs 6 Digital input switches and 4 Digital outputs with LED indication. 24V operated, built-in power supply, additional 5V, 1A Power Supply 4 NO contacts of the relays connected at outputs of the PLC and a buzzer Computer connectivity to download the program using USB Port with cable Professional Programming Component Connect Workbench To write Simple Ladder logic and test using digital inputs and outputs To write Simple Ladder logic and test using timer, counter, branching and subroutines I3 processor based system with Windows 7 Environment with service pack 1 or windows 8 OS should be provided by the Institute Detailed instruction manual Printed circuit Board (PCB) Size : 15’’x11’’
Thermal overload relay timing characteristics one no. 3 phase, 16A Main Contactor one no. 2-4.5A Overload relay Provision to connect 3 phase load externally (The Institute should provide the Load) 3 phase input, Fuses Wooden casing Detailed instruction manual
Working module for wire and test the control for jogging in 3 HP cage motor (without PLC) 1 no. 3 phase 16 A Contactor, 1 no. of Control relay 3 Phase input proper termination Stop, Start and Jog Push Buttons, Fuses and Power Terminations Control wiring termination Wooden casing Detailed instruction manual
Control circuit for Semi-automatic Star Delta Starter suitable for 5 HP 3 nos. of 440V, 16 A Contactors Main / Star / Delta Start / Stop / Push Button Switches Switch for manual delay operation (semi automatic) Control wiring termination, Powder Coated MS Stands, back cover Detailed instruction manual
Control circuit for automatic Star Delta Starter suitable for 5 HP 3 nos. of 440V, 16 A Contactors Main / Star / Delta 1 no. AC Timer (for automatic operation) Start / Stop / Push Button Switches Switch for manual delay operation (semi automatic) Control wiring termination, Screen printed Board, Powder Coated MS Stands, Acrylic back cover Detailed instruction manual
Dynamic braking control of AC Motor suitable for 3 HP One 3 phase, 440V, 16 Amps Main Contactor One 230V DC, 12A Contactor for connecting DC Supply AC Timer, Rectifier for DC Power Supply, Variac to be connected externally On/Off Push Switches Screen printed board, Powder coated MS stands, back cover Detailed instruction manual
Two speed Pole changing circuit. 2 nos. of 3 phase 16A Main Contactors 3 phase input, Fuses Speed 1, Speed 2 and Stop Push Switches Provision to connect two different pole 3 phase windings Screen Printed Board, MS tube stands, back cover Detailed instruction manual
Control circuit for forward – reverse operation for cage motor 2 nos. of 3 phase 16A Main Contactors 3 phase input, Fuses Stop, Start Fwd, Start Rev,Push Switches Control inputs and outputs wiring Proper termination for 3 HP cage motor Screen Printed Board, MS tube stands, back cover
Rotor Resistance Starter for 3 phase Rotor Resistance Induction Motor Start and Stop Switches 4 nos. of 3 phase 16A Contactors 3 Timers Provision to wire external resistances in the rotor circuit Institute has to provide 9 external resistances to be connected in the rotor circuit Provision to wire control and power wiring Screen Printed Board, MS tube stands, back cover Detailed instruction manual
Single Phase Preventer without PLC 1 no. 3 phase 16A Main Contactor 3 Transformers and 1 relay to deduct the phase failure 3 switches to test the phase failure Proper termination for 3 HP cage motor Wooden casing Detailed instruction manual
PLC based DOL Starter with single Phase preventer 16A, 3 phase Main Contactor, 6A Overload relay, Single phase preventer circuit Start and Stop Push Buttons, Fuses and Power wiring termination Control wiring termination Wooden casing Detailed instruction manual
PLC based Star Delta Starter suitable for 5 HP Motor 3 nos. of 16A, 3 phase Contactors, Start and Stop Push Buttons, Fuses and Power wiring termination Control wiring termination, Powder Coated MS Stands, back cover Detailed instruction manual
GM ELECTRONICS
BHARATH ELECTRIC MOTORS
Bright Power Solutions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .