Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹37.5 L+₹49,023 (1.32%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹38.7 L+₹1.7 L (4.51%)Rejected-Finance NO 1505 SHIV MANDIR DELHI GATE NAJAFGARH NEW DELHI 110043 | WEST | DELHI | 110043 | L3 | Rejected-Finance Not being lowest |
Tender Value
₹43.5 L
EMD Value
₹87,106
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Delhi Cantt-10
GE (West) Delhi Cantt-10
Addn/Altn of Bldg No P-152 (OR Living) line 629 TPT Coy ASC in the AOR of AGE B/R-III under GE (West) Delhi Cantt-10
2024_MES_666467_1
GE/DW-61 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
DELHI
Class D Category a(I)
8 documents required · 8 mandatory
₹500
GE (West) Delhi Cantt
₹87,106
Yes
28 Nov 2024
18 Jul 2024
14 Sept 2024
18 Jul 2024
12 Sept 2024
2 Aug 2024
Amount
Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified and directed.
Demolition of mud phuska on roof slabs, any thickness incl cleaning of roof surfaces and removing the debris out of MOD land complete all as specified and directed.
Scraping of old tar felt roof treatment over concrete padding of any thickness etc from roof incl finishes or junction or parapet and cleaning the surface (by mechanical means like grinder, etc) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as specified and directed. (Rate of WPC shall be included in unit rate)
M&L for water proofing treatment in following stages:- 1. Rendering in CM 1:3 with waterproofing liquid as per manufacturer's instruction over concrete surface finished even and smooth without using extra cement. 2. First coat of bitumen primer confirming to IS-3384@ 0.40 Kg/Sqm over plastered surface.(Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd). 3. Second coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over bitumen primer. 4. Third layer of APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm with a centre core of 90 micron high density polyethylene film protected on both sides with a high quality polymeric asphaltic mix, the polymeric asphaltic mix will be protected on both sides with thermo fusable HMHDPE film of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish.torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends complete all as specified and as directed.
M&L for repairing of spalled concrete from ceiling in the following stages:- a. Prepration of existing surfaces like chipping of unsound weak / loose concrete with electric hammer or manually including tapering all edges, making square shoulders of cavities etc. n.exc 50 mm thickness removal of debries, complete all specified and directed by the Engineer-in-charge. b. Applying rust remover cum passivator Sika rustoff 100 or equivelent @ 0.20kg/Sqm/per coat or as per manufacturer's specifications to remove rust from existing reinforcement (Make : Sika or equivalent) c. Applying a epoxy based zinc rich rebar corrosion protection system of product : Fiazin (R) R @ 0.15Kg/Sqm/coat or as per manufacturer's specifications (Make ; Sika or equivalent) d. Mixing & applying two component Epoxy resin concrete Bonding coat of Sikadur(R)-32 LP A & B @ 0.40 Kg/Sqm(Mixing proportion as per manufacturer's instructions) on prepared RCC surfaces as per manufacture specification including prepartaion of surface by chipping and throughly cleaning of surface complete whereever required over new reinforcement (if required) and as directed by the Engineer-in-charge.(Make : Sika) (Reinforcement will be measured and paid separatley). e. Apply a pre-batched one component polymer modified cementious patch repair mortar n.exc 50mm in layer of 15mm thick each of Product: Sika Mono Top®-122 F as per manufacturer insturctions and as directed by the Engr-in-Charge. f. Apply aluminised synthetic resin Concrete curing compounds for the prevention of premature water loss from concrete of product: Antisol®-E(WP) @ 0.10 to 0.20 kg/m2 as manufacturers instructions and as directed by the Engr-in-Charge. Note:- Cost of necessary scaffolding / form work shall be deemed to be included in quoted rates.
Supply & fixing 12mm dia steel sheer connector in grid pattern in between old core and new concreate as wherever directed by Engr-in-Charge and as specified by manufactorer including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring mortar SIKA anchor fix 3030 or equivalent of Hilte /Fischer.( The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item) complete all as specified and directed. Note:- Cost of necessary scaffolding / form work shall be deemed to be included in quoted rates.
M&L for drilling & chemical anchoring of new rebars/stirrups :- (i) Drilling in to the sound RCC members for anchorings of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 8 -12 mm dia bar- drilling length 80 to 100 mm Note : Anchorings of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar SIKA anchoc Fix 3030 or equivalent hilti/Fisher with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc. , compete. (The cost of drilling hole & chemical anchoring with epoxy resin is included in this item )
Providing and applying a non shrink, polymer modified cementitious micro-concrete Rendroc RG or equivalent from SIKA/BASF having compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength- 2 Mpa @ 28 Days, Flexural Strength(BS 4551-80)-5 Mpa at 28 Days. product shall have A1 Class Fire Rating confirming to EN1504 cl 5.5, Thermal conductivity of 1.5W/m degree C. Renderoc RG can be applied in sections upto 100mm deep. Pouring the same into the formwork using suitable arrangement or if required using pumping device for uniform flow of micro concrete. Rate is inclusive of preparatory works from item i) to item v) below, rates also includes cost of materials labour, tools and plants, cost of shuttering & scaffolding, safety arrangement quality control and testing etc. complete as per specification and as directed by Engineer.-in-charge. .
i) Chipping of plaster and unsound/weak concrete material till reinforcement bars are exposed, which enabls their rust removal vides item ii) below, from slabs, beams, and columns etc. with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-incharge including tapering all edges, making square shoulders of cavities etc complete and disposal of debris up for all lifts and leads.
ii) ) Rust removal by Providing and applying Fosroc Reebaklens RR or equivalnet from SIKA/ BASF, a combination of acid based material, corrosion inhibitors and dispersing agents rust remover, for removal of all rust/ scales/corrosion from reinforcement bars before microconcreting or patch repair,It Shall be applied with brush for complete wetting of rusted metal surface at coverage of 2- 2.5 Sqm/ltr. & allow it to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal /steel for about 5-7 days. Before applying any protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth
iii) Anticorrosive treatment by Providing and applying Nitozinc Primer an epoxy based zinc rich anti corrosive primer having adhesive bond strength ≥ 1.5 MPa as per ASTM D4541, & shall comply to per ASTM B-117 to be applied on well cleaned, fully exposed and all loose scale, rust free rust free surface obtained by grit blasting or suitable means , to be done with coverage @4.5sqm/litres to achieve a minimum thickness of 40microns DFT or as per direction of Engineer-In charge.
iv) Epoxy bonding for Old concrete & New concrete by providing and applying bond coat on the prepared surface with two component epoxy based bonding coat Nitobond EP of Fosroc make or equivalent, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C. Bonding agent shall have coverage not less than 2.5sqm/litres Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. Item rate is inclusive of materials all labour, tools and tackles. complete as per specification and as directed by Engg.-in-charge.
v) Work will complete only after proper wet curing has been done and testing of Microconcrete cubes filled up and cured by contractor during column jacketing work (100 mm size cube crushing strength at the end of 28-day to be not less than 45 N/sq.mm) and NDT tests mandated under item "Testing of works"
M&L form work to sides and soffits of floor or roof beams, beams, columns, slabs haunchings, griders bressummers lintels, cantilevers shelves including sup-ports, overhangs, etc also splays between floors and beams etc, complete all as specified and directed.
Demolition of reinforced cement concrete roofs, floors (other than ground floor), beams, staircases, landing, chajjas and similar suspended work .
M&L for ready mix concrete (RMC) of design mix M-25 (using 20mm graded stone aggregate) as in slabs, lintels supported on walls, beams and columns in floors, roofs landings, balconies canopies,deck slabs and in shelves and the like complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as specified and directed.
S&F TMT bars 6mm to 8mm dia cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as specified and directed.
All as per Srl item No. 20 above but TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sq. m but not exc 4 sqm each with shutters (without taking off shutters from the frames) , complete all as specified and directed.
Taking down chowkats or frames not exc. 1.5 sq. m with shutters (without taking off shutters from the frames) , complete all as specified and directed.
M&L Anodised aluminium window and ventilator shutters, side hung type or fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays/tower bolt 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S&F powder coated ( min thickness 50 micron )Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S & F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including fixing of hold fast with bed block of size 200x200x15mm in CM 1:2:4 (using 20mm graded agg complete all as specified and directed. .
M&L for preparation of new steel surfaces over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel painting over a coat of red oxide primer etc complete all as specified and directed.
S&F solid PVC Door Frame of size 50mm x 95mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F factory made solid Panel PVC moulded door shutter, 30mm thick (style) consisiting of frame made out of MS tubes for top and bottom rails. M.S. frame shall covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail, bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawing complete all as specified and directed.
S & F stainless steel butt hinges 100mm long medium weight etc complete all as specified and directed.
S & F 200mm long aluminum, anodized barrel tower bolts of extruded section complete all as specified & directed.
S & F aluminum anodised handle 150 mm long cast type complete all as specified & directed.
S & F 300mm long aluminium alloy anodised sliding door bolt hasp staple (bolt type) and clips of sheet cast of extruded section fixing bolts and sliding bolts of extrude section complete all as specified & directed.
S&F figured sheet glass, 5 mm thick, pin head type fixed with clips or putty complete in squares n.exc 0.50 Sqm each pane complete all as specified and directed.
M&L preparation of old painted of wood or wood based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted to steel and iron surfaces of any description over 10 cm width or girth not other wise described and applying one coat of synthetic enamel paint including easening of steel window by providing lubricant oil to hinges/pivot complete all as specified and directed.
S&F in repair110 mm bore PVC (SWR) pipes single socket in any length with rubber ring/ cement solvent cement joints fixed to walls incl MS clamps of suitable size made of flat iron 25x3mm including taking down old unsv pipes complete all as specified and directed.
S&F PVC bend/tee suitable for 110mm bore pipe complete all as specified and directed.
Complete removal of existing treatment of wall/Ceiling using wire brush/mechanical/ electrical driven sanders etc all as specified and directed
M&L for applying layer of 1mm thick white wall care putty for finishing the surface even to true aligned surface of wall/ceiling and smooth using sand papers etc all as specified and directed by Engineer-in-charge Make : Birla white/JK white/Altek
M&L for applying two coats of oil bound distemper including Priming plastered and other surfaces with alkali resistant priming pain on prepared surfaces (approved quality & tint) using machine spray on wall all as specified and directed.
M&L for applying two coat of cement base paint (approved quality & tint) complete all as specified and directed.
M&L for applying two coats of oil bound distemper on prepared surfaces (approved quality & tint) using machine spray on ceiling all as specified and directed.
M&L rendering 15 mm thick in ready mix mortar of approved makeon brick work or concrete on walls , finish the surface even and smooth without using extra cement as whole or in patch incl taking down old cement plaster of any description, complete all as specified and directed. Note:- (i) Cost for necessary steel formwork & shuttering of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M&L for rendering 10 mm thick ready mix mortar of approved make on ceiling and finished even and smooth incl taking down old plaster, complete all as specified and directed.
M&L for preparing newly plastered surfaces on walls and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls applying birla white putty 1 mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of alkali resistance primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of white wash on ceiling complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floor and paving n.exc 15CM thickness (below or above ground levelall as specified and directed.
M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) laid in alternate bays(not exc 2 Sqm each) finished even and fair at top using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 graded and three parts of sand by weight all as directed at site complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as sfd and directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in Cement mortar 1:6 complete all as sfd and directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan to any radious in half brick thick walls, built in Cement mortar 1:4 complete all as specified and directed.
Dismantling of floor, hearth or walling including cement mortar bedding (but not backing removing serviceable to store and rubbish off the premises complete all as specified and directed.
M&L for 40 mm thick cement concrete type B0 (1:2:4) using 12.5 mm graded stone aggregate as in sub bases complete all as specified.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc set and joined in neat cement slurry and pointed in white or colour cement to match colour tiles including 15 mm thick screed bed in CM 1:6 complete all as specified & directed.
M&L for glazed ceramic coloured tiles 450x300x7-8mm thick on vertical surfaces such as skirting and dado set and joint in neat cement slurry and pointed in white or coloured cement to match including 10mm thick plastering in C:M 1:4 rough to receive tiles.
M&L 20mm thick black granite of size in single pieces with full width of wall (tabled rubbed, polished and moulded) as in columns, steps, window cills and like laid over 15mm screed bed or plastering in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with the shade of granite including dismantling of stone slab complete all as specified and directed by the Engr-in-Charge.
M&L Mirror polishing to kota stone of existing floor where ever required to give high gloss finish complete all as specified and directed.
Demolition of cement concrete (unreinforced)/lime concrete/sunken floor of any description and in any position not otherwise specifically provided for by mechanical means (like drill machine, Hilti, pneumatic chisel, etc) complete all as spd & directed.
M&L PCC 1:5:10 Type E-2 (using 40 mm graded stone aggregate ) in mass concrete for sunken portion of WC, complete all as specified and directed.
M & L for Water proofing treatment of sunken RCC slab : (i) 15mm thick plater in CM (1:3) mixed with WP compound as per manufacturer's instructions shall be provided on sunken portion while the concrete is green. (ii) Apply cement slury @ 0.488 kg/sqm cement mixed with Acrylic based polymer modified cementious composite compound @ 0.253 kg/sqm and the surface will be allowed to air cure for 4 hours. (iii) Apply another layer of cement slurry @ 0.242 kg/sqm of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.126 kg/sqm and the surface will be allowed to air cure for 4 hrs. (Make of cement composite compound of Dr. Fixit/Fosroc/Sikka) (iv) Curing the sunken portion with water minimum for 7 days by ponding. (v) Paste 200micron thick poythene film of approved make with approved adhesives to the treated sunken surface. (vi) Joints/Traps/WC/Soil pies shall be properly sealed with approved sealing compound of approved make. (vii) Testing of all traps & joints shall be done after sealing and before filling of sunken slabs and ponding test for 96 hours. (viii) Spout pipe shall be provided for drain out the water in sunken portion. Note : Flat surface shall be measured for payment.
S&F in repair grating doom 100 mm dia of CP complete all as specified and directed.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified & directed.
Supplying and laying of 20 mm external dia CPVC pipes SDR 11 & Plain CPVC SDR 11 with all plain and brass fittings in trenches/ walls including dismantling old GI pipes including cleaning for refixing or removal to store complete all as specified and directed.
Supplying and laying of CPVC pipes 25mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all brass and plain fittings including dismantling old GI pipes complete all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors/walls fixed with MS clamps and shoe at ground level complete all as specified and directed.
S&F110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors/walls fixed with MS clamps and shoe at ground level complete all as specified and directed.
M&L for cast iron multi floor trap of 100mm dia,plain with grating including jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed.
S&F 110mm PVC (SWR) bends any radius complete all as specified & directed.
S&F 75 mm PVC (SWR) bends any radius complete all as specified & directed.
S&F PVC (SWR) 75/110 mm junction single/double, (double T), equal or unequal complete all as specified & directed.
S&F PVC (SWR) 110 mm vent cowl complete all as specified & directed.
Supply and fix in repairs chromium plated single tubular towel rail 20mm dia, D type 60 cm long between flanges, including a pair of CP brass brackets complete all as specified and directed.
Supply and fix for chromium plated soap dish complete all as specified and directed.
S&F in repair vitreous china wash hand basin, white flat back, size 580 x 450mm excluding taps, waste pipe chain and plug and porcelain but including brackets, waste coupling complete all as specified and directed.
S&F Vitreous China half stall urinal of size 465x355x265 mm, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified & directed.
S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified & directed.
Supply & fixed in repairs Vitreous china urinal partition white of size 310x700 mm Urinal partitions slabs terminating about 40cm above floor line complete all as specified and directed.
S&F in repairs Two way Bib cock, fancy type chromium plated cast copper alloy with capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed complete in all respect complete all as specified and directed.
S&F Health Faucet mild steel chromium plated suitable for 15 mm dai pipe with 1.25 mtr long flexible tube and wall hook including making connections and fixed in position complete in all respect complete all as specified and directed.
S&F Brass CP mixer for mixing hot & cold water (for wash hand basin) and fixed including dismantling of 15mm dia chromium plated pillar tap, complete all as specified and directed.
S&F in repair European vitretious china wash down water closet pan (excluding flushing cistern but including flush pipe and pvc seat cover white) complete all as specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
M & L for chromium plated bottle trap (with internal partition ) 32mm size with 250mm and 190mm long wall connection pipes & wall flange complete all as specified and directed.
S&F flushing cistern 10ltr capacity syphonic action type low clevel with inlet ball valve ,float valve and handle including bracket etc. complete all as specified and directed.
S&F 15mm dia bib taps, cast copper alloy chromium plated with capstan head fancy type,screwed down,screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs 15 mm bore chromium plated fancy type stop valve/angle valve, cast copper alloy screwed down high pressure with capstain head with long shank & cup complete all as specified & directed.
M&L in repair rotational moulded polythylene water storage tanks1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified including 20 mm brass valve high pressure with polythene float and fly nut complete and GI tank nipple, screwd for iron pipe complete all as specified and directed.
S&F in repairs Vitreous China squatting pan, ‘Orissa’ pattern' size 580 x 440 mm white with integral foot rests (excluding flushing cistern), including flush pipe of polyethylene of low or high density, connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete trap set in concrete and including S&F 100mm cast iron sanitary connection socket to fit WC out-let complete all as specified and directed.
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed.
Material and labour for concealed point wiring with PVC insulated unsheathed multistranded colour code copper conductor in PVC conduit with FRLS cable1.5 Sqmm size 1100 volts grade conforming to IS:694 in box of 1.6 mm thick including one coat of synthetic enmelled black paint and providing with brass screws and cup washers including single core multi stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit all as specified and directed by Engr-in-charge for the following :-
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
Material and Labour for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade conforming to IS:694 in new metal flush box of 1.6 mm thick including one coat of syenthetic enamelled black paint with new modular white cover plate with frame of suitable size of required colour fixed with brass screws and cup washers including single core multi stranded FRLS copper conductor 1.5Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for One 3 Pin socket 15A Indepentent board
S&F of switch piano type 5 amps single pole one way complete all as specified and directed.
S&F of switch piano type 15 amps single pole one way complete all as specified and directed.
S&F of socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F of socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S&F of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades and depositto MES store to store complete all as specified and directed.
Supply & fixing ceiling fans complete with blades, down rod, electronic regulator and accessories, 230 volt, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F of factory made epoxy polyester powder coated distribution board SP & N 12 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in of MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed.
S&F of SPN MCB 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.complete all as specified and directed.
Supply and fixing LED Building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
Supply and fixing of lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV,connection pipe incl all PVC & CP connections all as directed by Engr-in-Charge.
Supply & fix exhaust fan, steel body AC single phase. 230 V of size 300mm sweep with blades and frame and louvers complete all as specified and directed.
S&F ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed.
M&L far Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed.
M/S Ayub Khan (BID ID -3086361)
K S CONSTRUCTIONS (BID ID -3083965)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .