Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹36.3 L+₹1.2 L (3.38%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹39.3 L+₹4.1 L (11.8%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹41.7 L+₹6.5 L (18.5%)Rejected-Finance COLABA MUMBAI | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹42.4 L+₹7.2 L (20.6%)Rejected-Finance NAGPADA MUMBAI 10TH LANE KAMATHIPURA S P ROAD TELANG BLDG NO 23 ROOM NO 5 10TH LANE MUMBAI 400008 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹77,780
Closing Date
12 Oct 2023, 6:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
PROVISION OF ELECTRIC CHARGING STATION AT NAVY NAGAR UNDER GE NW NAVY NAGAR
2023_MES_619939_1
8301/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (NW) Navy Nagar, Colaba
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹77,780
Yes
27 Nov 2023
21 Sept 2023
13 Oct 2023
21 Sept 2023
12 Oct 2023
5 Oct 2023
21 Sept 2023 - 12 Oct 2023
Amount
Supply , installation , testing and commissioning of EV Charging station 9.9 KW capacity, AC Charger having output 3x3.3 KW with IEC 60309 socket 16A UNIVERSAL CONNECTOR AC output complete with following specification.
Input Votltage - 415 Vac (± 10%), 50Hz Three Phase
Wire- 4 wire
Number of output plug - 3
Output connector - Bharat AC (IEC -60309)
Output rating - 240 V , Max 16 A
Ambient temperature- -5°C to 60°C
Humidity - <95%, Non condensing, PF
Safety parameters - Over current , Under voltage, Over voltage,surge protection ,short circuit, graound fault , over temperature,residual current , emergency shutdown with electric shock.Emmergency stop push button
User authentication - App
Status indicator-LED Lamps for ON for 3 Phases, Charging and Fault
Cooling -Natural cooling
Network connectivity-SIM Based, Communication Protocol -HTTP
Push button - emergency stop
Ingress Protection-IP55
Metering and billing - Available throgh Software Suit
Chrging Operation - QR code scan/ App based authentication
Shell Material - Hot dip galvanised Steel sheet(Powder coated)
Mounting - wall Mount
Battery Back up-15 Minute
Visual indication display -4.3'' color LCD
Extend Wi-Fi RS 485, LAN
Regulation as per IEC61851
Make- Servotech, TATA, Biljlyfy,Sydler
Supply , installation , testing and commissioning of EV Charging station 60 KW capacity, DC fast Charger with dual gun output complete with following specification.
Rated power - 60kW
Number of Output - Dual Gun
Output current (per gun) - 150A
Input Votltage - 415 Vac (± 10%), 50Hz Three Phase
Output Charging Outlet - CCS2
Output Voltage - 150-1000V DC
Power Factor - ≥0.99
Efficiency - ≥94%
Display - 7" TFT LCD with touch, 9" TFT colour touch screen
Push Button - Emergency Stop
User Authorisation - APP & QR Code
Ambient Temperature - -20°C to 55°C, -20°C to 60°C
Storage Temperature - -40°C to 70°C
Humidity - <95%, Non condensing
SIM card/WiFi based network connectivity
Metering and Billing - Available through Software suit
Charging Operation - Scan QR Code / Mobile App
Safety parameters- Input/Output protection - Over / Under voltage protection, Overload protection, Short Circuit protection, Current leakage protection, Grounding protection, Surge protection, Over / Under Protection.
Shell Material - Hot dip galvanised iron sheet , Hot-dip galvanized steel sheet
Protection level - IP54, IP 55
Cooling - Forced Air Cooling
Regulation as per - IEC 61851-1 Charging Mode - 4
Certification - ARAI
Mounting - Floor Mount
Note for item No. 1 and item No. 2 :-
Supply , installation , testing and commissioning of Charge Point Management System to connect all current & future EV Charging infrastucure with following specifications :
Charger usage tracking (Daily/Weekly/ Monthly )
All Charging operations record backup, Customized Reporting
Manage Charging rates
EV Charger real time monitoring
EV Charger Health & Diagnosis check
Billing to users, Multi level user management
Web based application
Dashboard view
Management of EV Charging operations through Mobile Application with following specifications :
Availaible on both Android & iOS
Live loaction tracking & EV Station maps with navigation
EV Charger types & Status ( Busy/ Available etc. )
QR Scanning
Start / Stop Charging Sequence
Invoice generation
Slot booking
Hardware and software preferably from same make & manufactured/ developed in-house.
Pre Dispatch Inspection to be carried out by MES Rep before supply of material
Charger management & maintainace ( Both Hardware & Software) should be included in pay per use subscription based package with below features :
EV charger life time Guarantee coverage (excluding external damages)
24*7 customer care support (Technical & End customer issues any type of breakdown shall be attended within 24 hours & get rectified in 72 hrs else a penalty of Rs 1500/- per day shall be imposed.
Operational issues management
AMC / regular charger performance check up
Software management
Cloud Server maintenance
Cloud Space Charges
Payment refunds and settlement process
Per unit Rate for energy consumption by user would be decided by board of officer (BOO) after installation of EV chargers.
OEM would be responsible for collection of bill paid by user and meter bill of electricity supplied by MES would be deposited to BSO through MRO/online mode.
Make- Servotech, TATA, Biljlyfy,Sydler
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 120 sq mm, conforming to IS : 7098 part-I- 1988.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 35 sq mm. conforming to IS : 7098 part-I- 1988.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded copper conductor, 1100 volts grade, of size 4 core 50 sq mm, conforming to IS : 7098 part-I- 1988..
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded copper conductor, 1100 volts grade, of size 4 core 16 sq mm, conforming to IS : 7098 part-I- 1988..
Supply and fixing MCCB 250 Amps, 4 Pole, 36 kA, thermal magnetic release,(Ics=100% Icu) with sheet metal enclosure of suitable size complete all as specified and as directed.
Supply installation testing and commissioning of sheet metal enclosure including the following.
MCCB 63 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu)-01 Nos
S&F Smart Three Phase Meter, AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60A, with suitable size of CT conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper feaatures, Microprocessor and LED/LCD based on circuitry.-01 Nos
Supply, installing, testing and commissioning of LT feeder pillar box factory made cubical outdoor type, fabricated out of 3.15mm thick CRCA sheet ,slopy canopy with angle iron base frame made of 40x40x6mm, 45cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415V 3 phase 4 wire weather proof with IP-66 protection, with separate hinge door for each compartment for incoming and out going MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with copper busbar (TPN), suitable double compression copper cable glands complete in all respect for bay work station and including provn of the following:-
S&F MCCB 250 Amps, 4 Pole, 36 kA, thermal magnetic release, Ics=100% Icu - 01
S&F MCCB 160 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 02 Nos,(O/G)
S&F MCCB 63 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, (O/G)
S&F SPN 40 Amps 16 KA - 01 Nos (Spare)
S&F Smart Three Phase Meter, AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60A, with suitable size of CT conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper feaatures, Microprocessor and LED/LCD based circuitry.
LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
Phase indicator lamp R,Y & B (Set of 3)- 01 Set
S&F Copper Bus bar 400 Amps of suitable size, all are in equal size - Set 1(R, Y, B, N)
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils.
Removing excavated material from the site of work to outside MD land complete all as specified.
Cutting existing road surface or hard standing, bituminous topping exc 15 cm but n exc 30cm girth for laying of pipes/ cables and making good distrubed surface to match with existing complete.
M & L for cement concrete 1:4:8 type D2 (using 40mm grade stone aggregate) as in foundations, filling and mass concrete finished fair and even complete all as specified
M&L for High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 50mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M & L for earthing with galvanised iron earth plate electrode 600mm x 600mm x 3.15 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth not less than 1.5 mtr below ground level connected to the connecting GI strip 32x6 mm and including GI pipe 40 mm dia light grade for protection to the extend of 7.5 mtr as earthing lead by means of copper nuts, bolts as per connecting to equipment with provn charcol and salt complete all as per electric plate No 5 of SSR Part-1 including PCC chamber with RCC cover watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, including excavation and earth work and returning, filling in including ramming and removal of surplus soil and testing on completion complete.
Excavating in post hole or similar hole each n.exc. 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc. 25 cm, watering and removing surplus soil to adistance not exc. 50 mtr and making good surface in hard / dense soil complete all as specified and as directed by Engg-in-Charge.
M & L PCC 1:3:6 type C-2 (using 40mm graded stone aggregate ), as in foundation, filling & mass concrete, rough finished complete all as specified and as directed by Engg-in-Charge.
M&L mild steel work as in vertical tubular posts fixed independantly embedded into concrete complete all as specified and as directed
M&L for rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to FE 290 Gde 165
S & F Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
M & L applying two coats of synthetic enamel paint over one coat of primer on newly steel surfaces over 10 cm in width/girth inclu preparation of surfaces all as specified and directed.
S&F FI as in wind tie for roof including securing bolts and all necessary drilling bolting or rveting etc and similar works confirming to Fe 410-o or FE-310-o
M & L Surface dressing n exc 15 cm deep in hard /dense soil all as specified and directed.
M & L broken stone & boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M & L Cement concrete type C-2 , 1:3:6 (40mm graded aggregate) 100 mm thk in flooring, all as speciifed and directed
M&L for PCC 1:4:8 (40mm graded aggregate) as in foundation filling mass concrete
M&L brick work with subclass B brick straight or curved on plan exc. 6m mean radius , built in cement mortar 1:4 all as specified .
M&L coloured glazed cement concrete tiles 300 x 300 x 25 mm thick, machine pressed , glossy finish (reflective type), any design (as approved by GE); set jointed and pointed in neat cement slurry over and including 20 mm thick cement screed in cm 1:6 complete (Note : Cost for 20 mm thick cement screed is inclussive in the rate. No separate payment to be made.)
M&L for Machine pressed precast coloured glazed concrete interlocking paver block with grey cement & pigment, glossy finish (reflective type) any shape and size (as approved by GE) confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, as in pavements to required level & gradients, set, jointed with clean dry sand and sealing the ends using PCC 1:2:4 etc complete.
M&L for Sand filling under floors or in foundation including watering and consolidation etc complete.
M & L Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges Type B0 1:2:4 (12.5mm graded aggre-gate) all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement.
Material & labour for designed pattern ceramic tiles in vertical surface 300x450x7 to 8 mm thick set and jointed in neat cement slurry over and including 10mm thick cement plaster in cement mortar (1:4) and pointed in white or coloured cement to match complete all as specified and as directed by Engg-In-Charge. (Note : (i) The rate includes the cost of cement screed bed
M&L for 75mm thick PCC (1:3:6), type C2, using 40mm graded stone aggte as in plinth protection / paving, surface finished even & smooth with using extra cement as complete as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Complete all as specified and directed.
SHRI SAI ENTERPRISES
shubham construction
Veer High Tech Solution
SHREE SHIV ELECTRICAL
NOEL ENGINEERS
BRICKS ON CLOUD INFRA
ASHOK ENTERPRISES
K.C.P ENTERPRISES
shree arihant constrution
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .