Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.6 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹18.2 L+₹1.5 L (9.16%)Rejected-Finance H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | 2 | Rejected-Finance Other than lowest | |
| 3 | 3₹20.6 L+₹4.0 L (23.9%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 3 | Rejected-Finance Other than lowest | |
| 4 | 4₹23.4 L+₹6.7 L (40.4%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | 4 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
7 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR / MAINTENANCE OF EXTERNAL ELECTRIC WORKS, STREET LIGHT FITTINGS AND RO FILTERATION PLANTS AND OTHER CONNECTED WORKS OF RR UNITS OF 4 SECT AND 9 SECT UNDER GE (I) 873 EWS
2021_MES_449995_1
NIT-21 of 21-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) 873 EWS
₹60,000
Yes
15 Jul 2021
9 Jun 2021
10 Jul 2021
9 Jun 2021
7 Jul 2021
23 Jun 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cutting of existing road / hard standing for laying of GI protection pipe for cables, depth of trench not exceeding 0.75mtr, width of trench not exceeding 1.0mtr and making good by returning filling in (by well ramming and watering of soil in layers not exceeding 25cms), provision of 150mm thick sub base, 150mm thick WBM and there after 150mm thick PCC 1:2:4 type B-1 (using 20mm graded agggregate) including removal of surplus spoil to a distance not exceeding 50mtrs complete all as specified and as directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete for poles etc., complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete for stay etc, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable Poles all as specified and as directed.
Steel Tubular swaged poles type 410 SP-31 (9.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable Poles all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) all as specified and as directed.
Pin type porcelain in replacement, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Pin type insulator porcelain vitereous white, brown or green including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volts grade complet including taking down old unserviceable Pin type complete all as specified and directed.
Shackle type insulator porcelain vitereous white, brown or green including galvanised M.S. straps 31 x 5mm size, 150mm height, 150mm dia including galvanised mild steel straps, nut, bolts washers complete for 11000 volts grade insulator complete including taking up of old unserviceable Shakle type complete all as specified and directed.
Shackle type insulator porcelain vitereous white, brown or green including galvanised M.S. straps 31 x 5mm size, 75mm height, 90mm dia including galvanised mild steel straps, nut, bolts washers complete for 1100 volts grade insulator complete including taking up of old unserviceable Shakle type complete all as specified and directed.
Disc type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised 145 mm height 255 mm dia for 11000 Volts grade complete all as specified and directed.
Stay Assembly using stay rod of 20mm dia complete accessories as shown in Electrical Plate No 1 of SSR 2009 Part-I such as loop type insulator, porcelain, vitreous white/ brown or green, large size with overall dimensions 140x90mm clearance of hole 16mm, stay wire of size 7/4mm etc., complete all as specified (Earth work and PCC shall be measured and paid for separately)
Danger notice plate of size 25cm x 20cm x 1.5mm thick mild steel sheet, vitreous enamelled, white with letters, figures and conventional Skull & Bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size, all as specified and as directed.
Air break, gang operated with 09 Nos insulators outdoor type, mechanically operated suitable for horizontal or vertical mounting, fixed type, mounted on insulator and steel frame with operating mechanism worked from ground level, provided with locking arrangement for operating handle, consisting of MS channel, HT post type insulator, contacts of copper alloy, high pressure, heavy duty contact assemble, operating rod of 25mm dia GI pipe medium grade, drop out expulsion assemble of phases fuses etc conforming to IS : 1018 of 1972 with continuous current rating with 15 insulators of current rating upto 200 amps 11000 volts grade, complete all as specified and directed.
Lightening arrester expulsion type consisting of multiple spark gaps in series with one or more non linear resister to limit voltage surge on AC power circuit to interrupt power flow current suitable for outdoor installation and exposed directed to sun with ambient temperature between (-)10º C to (+)50º C suitable for surge discharge capacity 65 KA, 11000 volts grade conforming to IS-4350 including all fittings, complete all as specified and directed.
Painting of steel tubular pole 9 / 11 metre long with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all rusted surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and as directed.
Restringing / Restretching / Tightening of old ACSR conductor of any size and make on LT Poles by disconnecting and removing from insulators including providing necessary binding wire and jumpering after proper stringing all as directed.
Street Light fitting 60 Watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device including taking down old unserviceable Street Light Fitting all as specified and as directed. Make : Havells 'Endura Pearl Plus' Cat Part No SL60WLED757SASYTOPC or equivalent in Wipro / Philips / Crompton / Syska
Pole mounting bracket made out of medium grade GI pipe of 32mm dia, bent to 600 required shape of length 1.5 mtr with two No's of flat iron clamps made out of 32 x 6mm with 12mm dia bolts, nuts & washers duly painted with aluminium paint over a coat of primer including taking down old unserviceable brackets all as specified and as directed.
PVC insulated flat twin core cable with aluminium conductor 2.5 Sqmm for connecting Street Light fitting to DB complete including taking down old unserviceable cable all as specified and as directed.
MCCB 200 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) complete all as specified and as directed.
MCCB 160 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) complete all as specified and as directed.
MCCB 100 Amps, breaking capacity 16 KA, TP, 415V (adjustable thermal and magnetic release) complete all as specified and as directed.
MCCB 63 Amps, breaking capacity 16 KA, TP, 415V (adjustable thermal and magnetic release) complete all as specified and as directed. Makes of Serial Item No '27' to '30' : L&T / Legrand / Schneider / Havells / ABB
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 185Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 150Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 120sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 120sqmm to 185Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 95Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 70 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 50 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 35 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 25 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 Volt of capacity 25 KVAR complete all as specified and as directed.
Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 Volt of capacity 20 KVAR complete all as specified and as directed.
Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 Volt of capacity 15 KVAR complete all as specified and as directed.
Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 Volt of capacity 10 KVAR complete all as specified and as directed.
Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 Volt of capacity 5 KVAR complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 120 Sqmm 3 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 95 Sqmm 3 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 35 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 10 Sqmm 2 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 6 Sqmm 2 core on wall including taking down old cable, complete all as specified and as directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Steel pipe galvanised light grade, 50 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Cable Jointing Kit for HT 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 - 185 Sqmm including testing and commissioning, complete all as specified and directed
Cable Jointing Kit for HT 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including testing and commissioning, complete all as specified and directed.
Material and labour for disconnecting electrical connection removing the defective transformer, loading and transporting to workshop from site and vice-versa including disconnecting and rewinding of 11/0.433KV, 63 KVA to 250KVA, Three Phase, Four Wire, 50Hz vector group Dyn 11 transformer with paper insulated copper winding wire / strip as per original data on HV (delta connection) and LV (Star Connection) 7 tapping brought on HV side for tap charger to change + 2.5%, 5%, 7.5% by means of manually operated Off-Load tap changing gear complete rewinding of HV on three limbs providing insulation material like spares, wooden blocks, cotton tape etc. and re-conditioning three limbs complete opening, replacement of cock sheet packing, vent diaphragm replacement of LT terminal plate, breather, filling of new transformer oil for top up with existing oil after proper filtration upto level of 50 KV dielectric strength and testing of transformer at factory and site after connecting all electrical connection in full load all as directed.
Notes :- 1. Spares required will be measured and paid separately under appropriate item. 2. The Quoted Rate shall be deemed to include transportation, electrical connections, Testing & Commissioning.
Supply only following Items / Spares required for transformers :-
(a) Gasket suitable for 63 to 250 KVA Transformer
(b) LT Bush with rod of brass complete cork washer with nuts, bolts and washers of brass of requisite size suitale for 63 to 315 KVA
(c) HT Bush with rod of brass complete cork washer with nuts, bolts and washers of brass of requisite size suitale for 63 to 315 KVA
(d) Silica Gel suitable for breather for Transformer of capacity 63 KVA to 315 KVA
Supply, filling and top up with new Transformer Oil of dielectric strength more than 50 KV at 2.5mm gap confirming to IS : 335-1993 complete all as specified and as directed. Make : APAR Oils / Savita
Dehydration of transformer oil by using filtration plant of suitable capacity and removing the moisture / dust till obtaining the oil dielectric strength 45 KV at 2.5mm gap and above for various transformer / voltage stabilizer of any size located at different substations, complete all as specified & directed.
Spray Painting of complete Transformer with one coat of weather proof grey synthetic enamel paint after cleaning / removing dust, rust or carbon etc. including writing MES No / SM No complete all as specified and as directed.
Dismantling and refixing the complete unit of solar water heater installed at various sites complete overhauling, cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as nuts, bolts, wasahers and all other minor accessories as required at site including painting to solar water heater by rubbing the old paint and applying with two coats of synthetic enamelled paint by spray painting and testing the same after repair, complete all as specified and directed of the following description. Note: Replacement of spares shall be measured and paid for seperately.
a) Capacity 100 LPD
a) Capacity 300 LPD
b) Capacity 500 LPD
Supply only the following items / spares in replacement for Solar Heaters of various capacities as mentioned in Serial No 67 here-in-before all as specified :-
(a) Heating element of capacity upto 2 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½” complete.
(b) Glycol (Anti freezing solution) for filling in copper tubes complete.
(c) Dead flange with nut, bolts and washers complete.
(d) Float valve assembly 15mm dia complete.
(e) Thermostat suitable for solar heater complete.
(f) Hot water steel tank non stick 2mm thick with ceramic lining of capacity 100 Litres complete. Make : Surya Shakti / TATA BP or equivalent.
(g) Hot water steel tank non stick 2mm thick with ceramic lining of capacity 300 Litres complete. Make : Surya Shakti / TATA BP or equivalent.
(h) Hot Water Steel Tank non stick 2mm thick with ceramic lining of capacity 500 Litres complete. Make : Surya Shakti / TATA BP or equivalent.
(j) Toughned glass 6mm thick for collector for heat transmission.
(j) Coupling gasket
(k) Temp Gauge 0 degree centigrade to 1200 degree centigrade
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
Bidder Name
M/S BALI CONSTRUCTIONS
SWASTIK TRADERS
VARDHMAN INTERNATIONAL
R K BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .