Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC GURHA BRAHMANA TEH AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | ₹23.4 L Quoted ₹24.3 L | L1 | Accepted-AOC Accepted as L1 |
| 2 | L2₹24.5 LRejected-AOC | ₹24.5 L | L2 | Rejected-AOC other than L1 |
| 3 | L3₹25.0 LRejected-AOC | ₹25.0 L | L3 | Rejected-AOC other than L1 |
| 4 | L4₹25.0 LRejected-AOC | ₹25.0 L | L4 | Rejected-AOC other than L1 |
| 5 | L5₹25.3 LRejected-AOC | ₹25.3 L | L5 | Rejected-AOC other than L1 |
| Sl No | Description | Qty | Unit | M/s Rajesh Kumar Contractor L3 | M/s Vishwakarma Enterprises L5 | M/S Mahajan Construction Co. L4 | bushan kumar L1 | M/S KARAN SINGH CONTRACTOR L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling timber scantlings (framed work) 40 Sqcm and over in section, in any position complete all as specified and as directed. | 2 | Cum | 50 ₹100 | 100 ₹200 | 500 ₹1,000 | 10 ₹20 | 200 ₹400 |
| 2.00 | Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as speciified and directed. | 453 | Sqm | 5 ₹2,265 | 1 ₹453 | 10 ₹4,530 | 3 ₹1,359 | 5 ₹2,265 |
| 3.00 | Rolled mild steel structural work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified. | 2,900 | Kg | 89 ₹2.6 L | 90 ₹2.6 L | 91 ₹2.6 L | 89 ₹2.6 L | 90 ₹2.6 L |
| 4.00 | Pre-painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified. | 421 | Sqm | 620 ₹2.6 L | 620 ₹2.6 L | 699 ₹2.9 L | 623 ₹2.6 L | 600 ₹2.5 L |
| 5.00 | Pre-painted galvalume aluminum zinc coating GI based plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified. | 35 | Sqm | 600 ₹21,000 | 550 ₹19,250 | 699 ₹24,465 | 623 ₹21,805 | 600 ₹21,000 |
| 6.00 | Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. | 10 | Cum | 50 ₹500 | 100 ₹1,000 | 100 ₹1,000 | 50 ₹500 | 100 ₹1,000 |
| 7.00 | Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and as directed. | 9 | Cum | 3,000 ₹27,000 | 5,000 ₹45,000 | 5,000 ₹45,000 | 2,500 ₹22,500 | 4,500 ₹40,500 |
| 8.00 | Brick work with sub class ‘B’ (old size brick's) bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 in half brick thick, complete all as specified. | 20 | Sqm | 400 ₹8,000 | 200 ₹4,000 | 1,000 ₹20,000 | 350 ₹7,000 | 800 ₹16,000 |
| 9.00 | Taking down cement plaster on stone or brick walls/ceiling etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified. | 1,430 | Sqm | 5 ₹7,150 | 1 ₹1,430 | 5 ₹7,150 | 2 ₹2,860 | 2 ₹2,860 |
| 10.00 | Rendering 15mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface fair and even complete including mixing of WPC compound all as specified and directed.
Note : WPC to be paid seperatly as supply only. | 1,100 | Sqm | 150 ₹1.6 L | 100 ₹1.1 L | 130 ₹1.4 L | 143 ₹1.6 L | 160 ₹1.8 L |
Updated dates
Tender Value
₹36.2 L
EMD Value
₹72,500
Closing Date
18 Mar 2026, 6:00 pmClosed
GE (N) Akhnoor
GE (N) Akhnoor C/O 56 APO PIN-181201
SPL REPAIR TO BLDG NOs TR09 TR11 TR22 P11 P16 AT AKHNOOR UNDER GE N AKHNOOR
2026_MES_753177_1
GE(N)/AKH-76/2025-26
Open Tender
Civil Works
180 days
Akhnoor
Class Cat a i
8 documents required · 8 mandatory
₹500
GE (N) Akhnoor
₹72,500
Yes
30 Mar 2026
18 Feb 2026
20 Mar 2026
18 Feb 2026
18 Mar 2026
4 Mar 2026
Dismantling timber scantlings (framed work) 40 Sqcm and over in section, in any position complete all as specified and as directed.
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as speciified and directed.
Rolled mild steel structural work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified.
Pre-painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified.
Pre-painted galvalume aluminum zinc coating GI based plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and as directed.
Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 in half brick thick, complete all as specified.
Taking down cement plaster on stone or brick walls/ceiling etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
Rendering 15mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface fair and even complete including mixing of WPC compound all as specified and directed. Note : WPC to be paid seperatly as supply only.
Rendering 15mm thick cement plaster with cement mortar (1:6) on fair faces of brickwork or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over one coat of chalk whitening complete all as specified and directed.
Preparation of old plastered surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over old surfaces complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed.
20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 20mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed.
Description all as per item No-15 above but in skirting/dado incl 10mm thick rendering CM 1:4 complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm, as in floors, set and jointed in neat cement slurry and pointed in coloured cement laid over & including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed.
Description all as per item No 17 above but in dado/skirting etc incl 10mm thick rendering in CM 1:4 complete all as specified and directed.
50mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in plinth protection/path etc laid in alternate bays including extension joints , filling joints with mastic filling comprising thickness of 12mm cement concrete 1:2:4 over 25mm sand filling complete all as specified and directed.
25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub floor under tiles complete all as specified and directed.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) n.exc 1.50 sqm complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm and n.exc 4.00 sqm each, complete all as specified and directed.
Pressed steel frames for doors with one or more rebates of size 105x60mm including necessary fixing lugs, hinges, lock strike plates complete including one coat of red oxide primer providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed.
PCC (1:2:4) type B-0 (using 12.5mm graded aggregate) as in filling of pressed steel door frame including parapet coping complete all as specified and directed.
PCC (1:3:6) type C-1 (using 20mm graded aggregate as in hold fast blocks including necessary form work for rough finished surfaces complete all as specified and directed.
35 mm thick, 2nd class hard wood, glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified and as directed.
3mm thick glass sheet ordinary quality and glazed with oil in squares not exceeding 0.5 sqm in each pane.
Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed.
150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed.
Aluminium handles cast type anodised of size 100mm long ISI marked complete all as specified and as directed.
Floor door stopper 150mm overall length of cover plate of aluminium alloy body and tongue,anodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and as directed.
Curtain rail ,20 mm dia Stainless steel ,chromium plated fixed with CP braket, incl taking down of old curtain rods, complete all as specified.
steel windows/ventilator (Box type) factory made with double shutter with or without devetailed bar (glass & gauged shutter) of size 79mmx39mm, 16 gauge rectangular tubular frame with side hung shutter with glazing bars 13x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown in drg No. CEUZ/TD/1269/2008 Sh No 1/1 to 1/3. Note:- (a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid seperately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid separately under respective item.
Preparation new or old steel and iron surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed.
Preparation of new wooden surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint of 1st quality over a coat of pink primer complete all as specified and directed.
Broken stone boulder hardcore of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface, complete all as directed.
100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, finishing fair & even complete all as specified and directed.
Sand cushioning in flooring below interlocking tiles laid in layers 25mm thick complete all as specified and directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 60mm thick, M-35 grade , in paths and hardstanding,with grey cement and coloured pigment, laid tightly over and joints filled with dry sand. (Colour and pattern as approved by GE) complete all as specified and directed.
Plain Cement Concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregates) as in coping and edges of path, roof kerb including weathering, slightly rounded or chamfered angle and throating, necessary form work finishing all exposed faces of concrete etc complete all as specified and directed.
Taking down and refixing in the same position of Rolling shutters of any size and in any position making functional by way of repairs of ball bearing and spring and greasing complete and making good the surfaces complete all as specified and as directed.
Steel rolling shutters 1.25mm thickness of lath, with ball bearing, as specified including top cover, anchoring rod, hasp and staple erected in position as indicated, gear operated type with bevel gear box and crank handle complete all as specified and as directed.
Ball bearing for rolling shutters fixed in repairs complete all as specified and directed.
Glass dividing strips 3mm thick and 35mm width inserted in position and confirm design complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.
One light point controlled by one switch
One 3 pin 5 amps socket point controlled by one 5 amps switch on independent board
One 3 pin 5 amps socket point controlled by one 5 amps switch on same board
All as per item No 46 above but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- (a) One 6 Pin 16/6 amps socket outletr point controlled by one 16 amps switch on independent board.
Modular type switch 06 Amps, single pole,1way,1/2 module,240V, ISI Marked complete all as specified and directed.
Modular type switch 16 Amps, single pole,1way,1/2 module,240V, ISI Marked complete all as specified and directed.
Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed.
Modular type socket 16 Amps, 2/3 pin combined shuttered socket 2 module with light indication 240V AC ISI marked complete all as specified and directed.
Angle lamp holder, insulated body with back plate for LED lamp including removing old unsv item complete all as specified and directed.
Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
Fan regulator modular type electronic compatiable with BLDC fan, stepped type 100 watts, 2 module 240 volts AC ISI marked complete all as specified and directed.
LED light fitting 1x20W, 4 feet, 220V, general purpose surface and wall mounted LED batten with aluminium housing integrated electronic driver LED fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose as approved by GE fixed in repairs complete all as specified and directed.
LED INVERTER batten 20 watt 4 feet with square profile and poly carbonate channel lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hours and connecting up with twin core twisted copper wire from LED fitting to ceiling rose as approved by GE and removing old unserviceable fitting complete all as specified and directed.
LED bulb 12 watts, 240Volts,50Hz pin type and including removing old unserviceable item complete all as specified and directed.
LED secruity light fitting of capacity 35 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with suitable inbuilt surge protector and cable connection from ceiling rose to light fitting and testing and including removing of old u/s item complete all as specified and directed.
Supply & fixing and in repair sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 8 way suitable for flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 100Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat all as specified and as directed.
MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed.
MCB single pole & neutral 40 to 63 amps 240 volts 10 KA 'C' series complete all as specified.
Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM with Reinforcement bars of 8mm dia @120mm c/c excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.
Sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade,FRLSH type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Ceiling fans complete with blades. down rods, and accessories, 230 volt, 1200mm sweep, min air delivery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note:- Old u/s ceiling fans shall be deposited in MES store yard.
Supply, laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor of size 25 Sqmm nominal cross section x 4 core., 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs, including taking down old unsv cable, complete all as specified and directed.
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc and getting out in anysoft/loose soil complete all l as specified and directed
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed.
Removing surplus soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_843604.xls
BOQ • 0.47 MB
Tender76.pdf
Tender Documents • 1.03 MB
Download all tender documents and submit your bid