| 1 | L-1₹18.7 LAccepted-AOC BIKANER | BIKANER | RAJASTHAN | 334001 | L-1 | Accepted-AOC being L-1 | |
| 2 | L-2₹20.3 L+₹1.6 L (8.41%)Rejected-Finance HOUSE NO 93 WARD NO 8 NEAR ISKON TEMPLE UDHAMPUR J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹21.1 L+₹2.3 L (12.6%)Rejected-Finance C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-3 | Rejected-Finance other than L-1 | |
| 4 | L4₹21.3 L+₹2.6 L (13.8%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance other than L-1 | |
| 5 | L-5₹21.4 L+₹2.6 L (14.2%)Rejected-Finance | L-5 | Rejected-Finance other than L-1 |
Tender Value
Refer Docs
EMD Value
₹46,600
Closing Date
7 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI A K DUBEY
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO OFFRS MESS OF R AND O FLT UNDER GE (SOUTH) UDHAMPUR
2020_MES_398128_1
CWE/U(S)-83/2020-21
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SOUTH UDHAMPUR
₹46,600
Yes
3 Feb 2021
25 Nov 2020
9 Jan 2021
25 Nov 2020
7 Jan 2021
21 Dec 2020
60 days
Amount
Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil.
Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and as directed by Engr-in-Charge.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground floors), complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) as backing coat for receiving tiles/kota stone, complete all as specified and as directed by Engr-in-Charge.
Broken stone hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engr-in-Charge
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor, complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) as in sub base for receiving floor finishes complete all as specified and as directed by Engr-in-Charge.
S&F Dura stone tiles of size 305mmX305mmX10mm thick as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 20 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Vitrified tiles (double charged) tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in coloured cement to match the light shade of tiles and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
All as per serial item No. 11.00 here in before but on vertical surfaces as in skirting/dado over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed by Engr-in-Charge.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and directed.
Pre-painted coloured plain steel profied Galvalume/Zincalume sheet with Min 0.60mm thick TCT conforming to IS-513 (AZ-150 GSM, Al Zn alloy mettalic coating 550 MPA yield stress as per AS-1397) as roof ridge, hips, valley gutters etc. colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and directed.
75 mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in plinth protection complete, all as specified.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Applying one coat (1mm thick) wall care putty on new surfaces of walls including preparation of surface by brooming down or steel wire brushing, scrapping down vegetation growth, efflorscent salts and trading with oil greasy spot complete all as specified and as directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed by Engr-in-Charge.
12mm thick Non asbestos fibre cement building board (designer ceiling) of size 600mm x 600mm panel conforming to IS 14862 type B category three including anodised aluminium snap grid frame work with size of grid 605mm x 605mm for seamless ceiling comprising of aluminium perimeter I section members fixing with 4mm thick GI wire adjustable suspenders including all accessories complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / fan / bell/ exhast fan controlled by one switch with MS boxes of suitable for modular switch/socktes combination, including modular cover plate of suitable size,including blank plate(if required) for concealed on walls,switches, socket outlet, regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 25 above but one 3/5 pin 10 Amp socket outlet on independent board .
Description all as per item No 25 above but one 3/5 pin 10 Amp socket outlet on the same board with other switch.
Description all as per item No 25 above but one 3/5 pin 20 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 25 above but one 3/5 pin 20 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 4 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Switch piano , single pole, one way ,10 Amp (modular type) , complete all as specified and as directed by Engr-in-Charge.
Switch piano , single pole, one way ,20 Amp (modular type) , complete all as specified and as directed by Engr-in-Charge.
Socket outlet modular type 10A - 5 pin combined 2 module, complete all as specified and as directed by Engr-in-Charge.
Socket outlet modular type 20A - 2 in 1 pin combined 2 module, complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole ,with all acessories, complete all as specified and as directed by Engr-in-Charge.
Bell push Modular type 10 Amps 230 volts, 1 Module complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Stepped type fan regulator 120W, 230V 50 C/S, Deluxe Modular type electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Taking down ceiling/exhaust fan any type and any sweep and removing fan blade including cleaning all dust particle and filling cavities with filler materials, oiling, greasing including painting fan and blades complete with one coat of synthetic enamel white paint by spraying and writting Ser No/MES No with black paint complete and assemble the same along with all fixing connecting accessories and fixing in same position along with all new electric wire connection from ceiling rose to fan, etc. complete, all as specified and as directed by Engineer-in-Charge.
S&F LED light fittng flat PANEL 2x2, 34 Watt LED environmental friendly, new genaration, aesthetically designed ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for armstrong/Grid ceiling all as specified and as directed by engineer in charge.
Slim linear LED lighting fixture 18/20 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge.
S&F Slim linear LED lighting fixture 5 Watt LED Batten, For mirror light purpose, complete making all connection using 1.5 sqmm copper conductor multi stand PVC insulated 3 core flexible cable from ceiling rose to fitting complete all as per the directiond of Engr-in-charge.
S&F round surface mounted LED flat panel 18 watt, PDC aluminium housing for outside complete all as per the directiond of Engr-in-charge.
S&F Surface mounting 12 watt LED peacock, 6000K, wall/ceiling mounted fixture with electronic driver and opaque diffuser, suitable for indoor applications complete all as per the directiond of Engr-in-charge.
Ultra slim recess mounted square type downlight 1 x18 watt slim recessed for false ceiling, energy saving with IP65 with opal diffuser, pressure die cast aluminium housing & ring for sturdiness & corrosion resistant, epoxy powder coated, isolated driver, with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volt, colour temp 6500K, Low heat generating LED complete making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engg-in-Charge.
S&F recess mounted 8 watt LED LUMENO square/round, spot light for low ceiling height applications (In diff coloured) which provide soft light and glare free illutions complete all and specified and directed.
S&F 10 watt Zoom downlights (round) WW recessed mounted round COB based fully adjustable LED spot light complete all as per the directiond of Engr-in-charge.
S&F 40 watt wall mounting, chrome finish fixture with textured glass suitable for CFL/LED B-22 Including warm white mini glass lamp E14 type, suitable for the fixture, complete all as specified and directed.
Supply & fixing 9/10 watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval plastic bulk head LED luminaire comprising of high brightness LEDs, IP-54 protection colour temp 6000K, Low heat generating LED complete making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engg-in-Charge.
Supply and fixing LED Street Light fitting 25 Watt, New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 with acrylic, powder coated, pressure die cast aluminium compact high power LED tube light with heat resistant toughened Glass, Corrosion resistant, isolated driver low heat generating LED including nuts, bolts, washers with suitable size/dia 40mm GI pipe bracket for fixing of street light including making all connection, complete all as per the direction of Engg-in-Charge.
Note for Srl item No 39 to 49 :- A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 51 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of capacity 20 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed. (Note: MCBs will be measurd separately).
MCB SP, 10 to 32 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in soft/loose and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and directed.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
VTPN distribution board,vertically including MCCB 63 Amp , 16kA (as incommer) 4 way, double door IP-43 protection, complete all as specified and directed by Engr-in-Charge. (Including all PCC & cementing work for installation of TPN DB to wall ).
khajuria builders
M/S ASHOK KUMAR PACHIALA
SINGH CONST CO
paras ram pachiala
RAMAN CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .