Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹18.4 L+₹2.6 L (16.4%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹20.9 L+₹5.1 L (32.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹25.6 L+₹9.8 L (61.9%)Rejected-Finance H NO 21666 POWER HOUSE ROAD STREET NO 9 BATHINDA PB 151001 | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹27.3 L
EMD Value
₹54,600
Closing Date
7 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Kapurthala
GE Kapurthala
Repair/Maintenance of services connection and connected work at Old Cantt Kapurthala under GE Kapurthala.
2024_MES_687978_1
GE KPT- /2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Area under GE Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Kapurthala
₹54,600
Yes
1 Feb 2025
10 Dec 2024
14 Jan 2025
10 Dec 2024
7 Jan 2025
24 Dec 2024
Amount
Taking down existing LT panel by disconnecting all incoming and outgoing cables, earthing connection, dismantling PCC and making good the disturbed surface complete all as specified and as directed by Engr-in-Charge.
Dismantling & taking down existing ACSR conductor of any size by opening the binding wire from HT/LT electric poles complete all as specified and as directed by Engr-in-Charge.
Supply, fabricating, installation, commissioning, testing and electrically connected CPRI approved manufacturer LT Junction Box out door cubical type, Double door, made of 3.15 mm thick CRCA sheet steel on angle iron frame 60mm x 60mm x 40 mm of with front side hinged door, locking arrangement, vermin proof, painted with 2 coats of synthetic enamel paint over a coat of red oxide (internal & external surface) with heat shrinkable sleeves on AI bus bar 350 Amp capacity - 04 Nos providing holes (not less than ten nos of 3Ph distributions) for the connection of outgoing cables, complete wiring with thimbles and other accessories using crimping tool including foundation for fixing over PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation complete all specified and directed by Engr-in-Charge comprising the following :- (i) MCCB 4 pole, 415 volts of Capacity 100 Amps 25 ka - 01 No. (ii) Indicating lamps, LED type, 230 V AC - 03 Nos. (iii) Digital Voltmeter, 3 Phase - 01 No. (iv) Digital Ammeter 3 Phase - 01 No. (v) CT coils -03 Nos.
S&F in replacement of factory made powder coated Vertical DBs TPN ,440 V, 4 Way, in double door suitable for flush mounting and surface mounting with 250A copper busbar for each phase with 2 neutral bar, 2 earth bar and cable ties for cable management and fully insulated busbar and shrouded neutral bars with provision of 160 A FP MCCB as Incomer and SP 6 to 32 Amps and 40 to 63 Amps for out going complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of factory made powder coated Vertical DBs TPN ,440 V, 6 Way, in double door suitable for flush mounting and surface mounting with 250 A copper busbar for each phase with 2 neutral bar, 2 earth bar and cable ties for cable management and fully insulated bus bar and shrouded neutral bars with provision of 250 A FP MCCB as Incomer and SP 6 to 32 Amps and 40 to 63 Amps for out going complete all as specified and as directed by Engr-in-Charge.
M & L in replacement for earthing complete with galvanized iron or steel or steel earth plate electrode of size 60cmx60cmx6.3mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI Strip of size 32x6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh GI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in plate No 5 of SRR-1991 Part-1 complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified and as directed by Engr-in-Charge.
Supply, Laying, jointing and testing XLPE LT cable, 1100 volts grade (heavy duty) with stranded aluminium conductor, cross sectional area 16 Sqmm 2 core fixed along the poles or passing through pipes or laid under floors or through walls complete all as specified and as directed by Engr-in-Charge. Note (i) Earthwork, sand cushioning, brick protection and GI pipe to be measured and paid for separately under respective items.
All as per item No 11 above here in before but cross sectional area 16 Sqmm 4 core complete all as specified and as directed by Engr-in-Charge.
All as per item No 11 above here in before but cross sectional area 25 Sqmm 4 core complete all as specified and as directed by Engr-in-Charge.
All as per item No 11 above here in before but cross sectional area 35 Sqmm 3½ core complete all specified and as directed by Engr-in-Charge.
All as per item No 11 above here in before but cross sectional area 50 Sqmm 3½ core complete all specified and as directed by Engr-in-Charge.
All as per item No 11 above here in before but cross sectional area 70 Sqmm 3½ core complete all specified and as directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out including trimming of sides complete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and as directed by Engr-in-Charge. Note :- For measurement 18cm thickness shall be considered.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent to each other complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement 50mm dia GI pipe light grade for cable protection inclunding all fittings laid in trenches or fixed on pole complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement 80mm dia GI pipe light grade for cable protection inclunding all fittings laid in trenches or fixed on pole complete all as specified and as directed by Engr-in-Charge.
Northern cable fault locatoers (BID ID -3207715)
DUGGAL CONSTRUCTION CO (BID ID -3205334)
SUNRISE ENGINEERS AND CONTRACTOR (BID ID -3207473)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .