Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.8 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted tenderer | |
| 2 | L2₹90.5 L+₹16.7 L (22.6%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | Rejected-Technical 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | - | Rejected-Technical Not recommended being due to not full filling eligible cat criteria as per NIT |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
30 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Allahabad
HQ CWE New Cantt Allahabad
PROVN OF AUGMENTATION OF EXISTING 33 KV MRS WITH PROVISION OF ONE ADDL 3.15 MVA CAPACITY, 33/11 KV TRANSFORMER TO FACILITATE TOTAL KLP REQMT AT FAIZABAD CANTT.
2020_MES_347600_2
81539/FZD/E8
Open Tender
Civil Works
Item Rate
180 days
Faiazabad
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE Faizabad
₹1.8 L
Yes
26 Nov 2020
7 Sept 2020
2 Oct 2020
8 Sept 2020
30 Sept 2020
16 Sept 2020
60 days
Amount
Supply, installation, commissioning and testing transformer floor mounted capacity 3.15 MVA step down, outdoor type, 50 Cycle (50 Hz), AC double wound core type copper wound oil immersed oil natural air naturally cooled (ONAN) type with external cooling tubes/ fins, transformer delta connection on primary side (33 KV) and star connection on secondary side (11 KV) in accordance with vector symbol DYN-11 and having tapping range at of + 5% to - 20% @ 1.25% (20 Steps) changed by means of auto on load tap changing arranged with option for manual tap changing arrangement. The voltage regulation shall be as per IS. The limit of temperature rise after continuous full load run as specified in SSR Part I and IS 2026 shall be suitable adjustable to suit the maximum ambient temperature prevalling at site all as specified. The transformer shall be completed with following fittings and accessories :-
(a) Cable boxes on 11 KV secondary side for 3 core XLPE 185 sqmm x 3 core cable end. (b) HV bushing with arching horn on 33 KV side. (c) Oil conservator with filling hole and cap drain plug and oil level gauge. (d) Dehydrating breather with connecting pipe first fill of dehydrating agent and oil seal. (e) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe connection to conservator air space (pressure release device). (f) Air release plug. (g) Shutoff valve between the conservator and cooilng tubes. (h) Filter valve with threaded adopter (Top and bottom). (j) Thermometer pocket. (k) Inspection cover.
(l) Jacking pads, handling and lifting lugs. (m) Skid type underbase channel with Wheels. (n) Rating plate and terminal marking plate. (o) Extra bushing for neutral out side the LV side. (p) First filling of transformer oil. Transformer oil shall be as per IS:335. (q) Cover lifting eyes. (r) Double float Bucholz relay with trip and alarm contacts. (s) Dial type oil temperature indicator with alarm and trip contacts. (t) Dial type winding temperature indicator with alarm and trip contacts. (u) Overloading capacity as per IS: 6600. (v) Noise level as per NEMA TR1. (w) Foundation as per manufacturer's instructions including Rail section and channel embeded in foundation of suitable size in and incl RCC/PCC platform incl ramp and necessary earthwork and excavation as directed.
Supply and installation, testing and commissioning of Outdoor type HT 33 KV ,3 phase, 50 cycles 1600 Amps, 25 kA, Non-Extensible fixed Type , SF6 Gas insulated compact switchgear comprising of motorised fixed type Breaker contacts including the following with all necessary standard fitting :- (a) Live tank SF6 breaker with rated pressure of SF6 in operating chamber at 20 degree C - 5 kg/sqcm with motorised spring type operation for closing and opening. (b) Rated voltage 36 KV (rms), rated current 1600 Amp at 50 Hz. (c) No of poles - 3 with SF6 gas parameters as per IEC-60376. (d) Rated assymetric breaking current 28.4 kA. (e) Rated short circuit peak withstand current at rated voltage 62.5 kA (peak). (f) Rated short time withstand current 26.3 kA for 1 sec and 3 sec. (g) Integrated non-removable spring-charging operating handle and ON/OFF push buttons mechanically attached to the mechanisum. (h) Rated break time </=80 ms, closing time </=100 ms, Opening time </=50 ms. (j) Arc proof cable covers with self interlocking mechanism earth switch, disconnector. (k) Mechanical indications for breaker ON, OFF, EARTH TRIP, Spring Charged-Discharged.
Supply, install, testing and commissioning indoor type Control and Relay Panel(CRP) for 33 KV SF6 breaker made of CRCA Sheet 2mm thick, standard size, prewired with suitable size copper conductor, enclosed cubical type free standing, dust tight, vermin proof, powder coated RELAY CONTROL PANEL FOR PROTECTION METERING OF 33 KV EQUIPMENT AND TRANSFORMER, suitable for 24 V DC supply, duplex type to house the following accessories as per the following specification :- (A) Control & Relay Panel. (a) Control & Relay Panel - Siplex type - 01 No. (b) Colour code wiring - 01 No. (c) Paint shade - 631 of IS5 - 01 No. (d) Neoprene Gaskets - 01 No. (e) Degree of protection - IP55 - 01 No. (f) Control voltage - 110 VDC - 01 No. (B) Meters. (a) Digital Ammeter with ASS - 01 No. (b) Digital voltmeter with VSS - 01 No. (c) Multifunction Meter - 01 No.
(d) MW Meter with Transducer - 01 No. (f) Energy Meter - 0.2 class - 01 No. (C) Indication Lamps LED Type. (a) Breaker ON - Red - 01 No. (b) Breaker OFF - Green - 01 No. (c) Auto trip indication - Amber - 01 No. (d) Trip circuit healthy - Clear - 01 No. (e) Spring charged - Blue - 01 No. (f) RYB Indication - 01 No. (D) Accessories. (a) Push Button for trip circuit healthy check - 01 No. (b) Trip Neutral close switch - 01 No. (c) Local remote switch - 01 No.
(d) Panel space heater with thermostat & switch - 01 No. (e) Panel illumination lamp with switch - 01 No. (f) 2/3 pin plug with switch - 02 Nos. (g) 6 - Window Annunciator - 01 No. (h) Hooter - 01 No. (j) Semaphore Indicator - 01 No. (k) Mimic Diagram - 01 No. (l) Test terinal block - 01 No. (E) Relays. (a) Numerical communiction non-drawout type relay with 50/51/50N Protection. Model-CGI14C - 01 No. (b) Trip Circuit supervision relay - 01 No. (c) Master trip relay - 01 No. (d) Transformer differential relay - 01 No. (e) Over current and earth fault relay - 01 No. (f) Auxillary relay - 02 Nos.
Supply and fixing of 33 KV, 50 Hz, Single Phase outdoor type, 20 KA for 1 sec, oil filled current transformer Ratio 100-50/5-5 A, two core, STC : 20 KA for 1 Sec, Creepage : 900 mm, insulation level : 70 KV/170 KV peak core - 1 class 1.0, 15 VA, core - 2 : class 5P10, 15VA suitable for 33 KV complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of 33 KV, 50 Hz, Single Phase, oil filled inductive potential transformer outdoor type, Ratio - 33/sqrt(3)/110/sqrt(3), Two secondary windings, voltage factor - 1.2 continuous, 1.5 for 30 Sec, Creepage : 900 mm, Windding - 1: class-1.0, 100 VA suitable for 33 KV complete all as specified and directed by Engr-in-Charge.
M&L for Lightning arresters HT 33 Kv 10 KA (Station Class) expulsion type complete with all fittings, all as specified and directed by Engr-in-Charge.
Supply installation, commissioning and testing of HT 33 KV outdoor type gang operated air-break switch with insulator and earth switch upto 200/400 Amp and fitted on steel frame horizontal operated (rotary type) mechanisum from ground level consisting of operating rod of 25 mm bore light grade GI pipe of suitable length worked from ground level and with locking arrangement including clamp, nuts and washers all as specified and directed.
Supply and install HT 33 kV Drop out fuse with double stack channel type insulator including fixing arrangements all as specified and directed.
Supply and install HT 33 kV Disc insulator including fixing arrangements all as specified and directed.
Supply and install HT 33 kV Post insulator including fixing arrangements all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint etc all as specified and directed by Engr-in-Charge.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4.0 sq mm, 4 core, 1100 Volts grade all as specified and directed by Engr-in-Charge.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,8 core, 1100 Volts grade all as specified and directed by Engr-in-Charge.
M&L for aluminium conductor, steel reinforced (ACSR) of any size including straining, binding to insulators with aluminium binding wire with connectors, etc providing PVC sleeves for jumpers as in OH conductors complete all as specified and as directed.
Surface excavation n. exc 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out all as specified and directed.
Supply, laying stone aggregate 40mm grade all as specified and directed.
Supply and fixing stay assembly complete with accessories shown in electrical plate No 1 with stay rod of 20 mm dia including loop insulator suitable for 11 KV (size 90x140 mm) with clearance of hole 25.5mm and MS stay plate size 300mm x 300mm x 6mm, stay clamps etc all as specified and directed.
Supply and fixing stay wire of galvanised iron stranded of size 7/3.15 mm all as specified and directed.
S&F danger notice plate 1.6 mm thick mild steel sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size for 11 KV/33KV system size 25 x 20 cm all as specified and conforming to IS: 2551- 1982.
M&L for shifting of vaccum circuit breaker - 05 Nos indoor type 11 KV including disconnecting HT cable & bus bar for making space for fixing of proposed breaker complete all as specified and directed by Engr-in-Charge.
M&L for shifting of Station Transformer of capacity 25 KVA after Disconnecting all the electric connections from HT and LT side and earthing terminals from the transformers including fixing to another location (not more than 10 m) with and including necessary new RCC/PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) foundation, plateform, ramp etc of suitable size and necessary excavation and earthwork complete all as directed by Engr-in-Charge.
M&L for shifting of Steel Structure - 06 Nos i.e. (structure for Post insulator - 04 Nos, Structure for LA - 01 No & structure for Isolator- 01 No) Disconnecting all earthing terminals from the structure incl fixing to another place with and including necessary new PCC1:2:4 type B-1 (using 20mm graded stone aggregate) foundation, coping etc and necessary earthwork and excavation as per manufacturer's instructions complete all as specified and directed.
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for laying of cable / taking out water supply pipe line in soft/loose soil, taking out excavated material,forming bottom etc complete all as specified and directed.
Returning filling in including, spreading, levelling watering and well ramming in layer n.exc 25 cm thick each layer in soft/lose soil all as specified directed.
Removing excavated material n.exc 50 mtr and deposting where directed at a level n.exc. 1.5 mtr above starting point complete all as specified and directed.
M&L for sand cushioning in trenches for protection of under ground cable provided in layers of sand 8cm deep before laying the cable and 15cm deep after the cable (Punned down to 18 cm) complete all as specified and directed.(Note:- Punned thickness as 18 cm shall be measured and paid)
Supply and laying Un-reinforced precast concrete cable cover 'factory made' of class HPV, Type 1 with peak of size 300 mm x 180 mm x 40 mm complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL with top edge of plate not less than 1.50 m below normal ground level) connected to galavanised earth lead strip 32mm x 6 mm (7.5m) as means of bolts, nuts, check nuts and washer besides brazing at all joints as shown on drawings and including excavation, earth work, GI pipe (ISImark) light grade 40mm bore for protection of GI strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6, type C-1(using 20 mm graded crushed stone aggregate ) chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40 mm thick pre-cast RCC cover 1:2:4 , type B-1(using 20 mm graded crushed stone aggregate ) reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade(ISI marked) for watering all as shown in electrical plate No 3 of SSR Part-I and connected to earth test point including complete all as specified and directed. (Note:- The rates quoted shall also deemed to include the cost of Earth test point and earth strip and protection pipe upto 7.5 meter beyond the earth plates electrode)
M&L for earth continuity conductor or main earthing lead fixed to walls or to poles or any other indicated situation for loop earthing with 32mm x6mm galvanised iron strip complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead fixed to walls or to poles or any other indicated situation for loop earthing with 25mm x3mm aluminium strip complete all as specified and as directed.
Supply & laying steel tubing, galvanized light grade 40 mm bores, for passing GI strip/Control cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as specified and directed.
Supplying, laying, commissioning & testing HT underground 185 Sqmm 3 core cable 11 KV grade (E), XLPE insulated, PVC sheathed heavy duty, steel strip or wire armoured with multi stranded aluminium conductor all as per IS 7098 (Part-I) 1998, laid in trenches, ducts, pipes or on poles, etc all as specified and directed by Engr-in-Charge.
Supply & fix cable jointing kit for 11 KV(E) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm all as specified and directed by Engr-in-Charge.
Supply & fix cable jointing kit for 11 KV(E) grade cable for Outdoor termination cold shrink type joint complete with jointing material and accessories for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm all as specified and directed by Engr-in-Charge.
Supply & laying steel tubing, galvanized light grade 100 mm bores, for passing GI strip/Control cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as specified and directed.
Supply, installation, commissioning and testing HT 11 KV 630 Amp Vacuum Circuit Breaker panel of 5 with 1 Incomming, 2 Outgoining and 2 Bus Coupler indoor type, horizontal isolation type, motor operated spring charged having rupturing capacity 18.4 KA for 1 second by connecting to the HT panel board with the help of copper bus bar of suitable size duly enclosed in CRCA frame and panel shall be not less than 2.0 mm thickness and comprising of the following complete all as specified and directed by Engr-in-Charge :- (a) Electrical and Mechanical interlock and automatic safety shutter door. (b) Power Pack for control circuits. (c) Assembly of five vacuum interrupter complete with epoxy support insulator and self-alligning finger type isolating contacts, 630 Amps breaking capacity 18.4 KA. (d) 230 Volts AC Motorised mechanism, spring charging with independent closing/ tripping push buttons and mechanical breaker "close/open" spring charged/discharged indication.
(e) Mechanical operation counter. (f) Electrical releases coil 24 volts DC (g) Shunt trip/ close coil 24 volts DC. (h) Auxillary switch. (j) 230 Volts AC single phase 80 watt rated strip type heater with toggle switch and thermostat - 05 Nos (For each of 5 VCBs). (k) Cable termination for 1 x 3C x 185 Sq mm XLPE cable (for incoming & outgoing). (l) Digital Ammeter flush type CT operated - 03 sets (For incoming VCB and outgoing VCBs). (l) Digital Voltmeter flush type - 03 sets (For incoming VCB and outgoing VCBs). (l) Digital Multimeter/ Energy analyser flush type - 03 sets (For incoming VCB and outgoing VCBs). (m) Numerical type 3 phase over current and earth fault relay with 50/51/50N/51N protection, model-CGI14N of make: CG or equivalent in make as mentioned in Appendix 'A' to PS - 3 Nos (For incoming VCB and outgoing VCBs)
(n) Numerical type 3 phase over/ under voltage relay with 27/59 protection, model-CGV24C of make: CG or equivalent in make as mentioned in Appendix 'A' to PS - 3 Nos (For incoming VCB and outgoing VCBs) (n) Master Trip Relay of make: CG or equivalent in make as mentioned in Appendix 'A' to PS - 3 Nos (For incoming VCB and outgoing VCBs) (o) LED Indication lamps for Breaker ON, Breaker OFF, Auto Trip, Trip circuit healthy, Spring Charged, RYB indication as per standard colour code. (p) Push button for Trip Circuit healthy. (r) Cable gland of suitable size. (s) Cubical LED illumination lamp - 01. (t) Potential transformer ratio three single phase draw out type 11 KV/rt3/110V/rt3 class 0.5, burden 100 VA (set of 3) - 1 set for Incomer VCB. (u) Battery bank, comprising of 02 Volt, 100 AH, 12 Nos battery and battery charging system made of 1.6 mm thick CRCS sheet all as specified 24 volts DC for Auxillary supply. (v) Epoxy Rasin cast CT of ratio 400-200/ 5-5 class 0.5/ 5P10, burden 15VA/15 VA for incomer VCB (set of 3) - 1 set. (w) Epoxy Rasin cast CT of ratio 300-150/ 5-5 class 0.5/ 5P10, burden 15VA/15 VA for outgoing VCBs (set of 3) - 2 sets.
DEORA ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .