| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC RZ 40 PALAM VIHAR DWARKA SECTOR 6 NEW DELHI 75 | NEW DELHI | DELHI | 75 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | Rejected-Technical 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Rejected-Technical No, Not enlisted in required category of work | |
| 3 | Rejected-Technical 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | - | Rejected-Technical No, Not enlisted in required category of work |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
COMPREHENSIVE MAINTENANCE AND REPAIR/REPLACEMENT OF INTERCOM SYSTEMS AT VARIOUS LOCATIONS AND OTHER MISC WORKS UNDER GE (U) PM DELHI CANTT-10
2024_MES_656094_1
GE(U)/PM/D-83/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Delhi cantt-10
MES contractor enlisted under class D cat d(iv) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹80,000
Yes
9 Nov 2024
27 May 2024
27 Jun 2024
27 May 2024
25 Jun 2024
10 Jun 2024
Amount
Section-I Comprehensive maintenance of server based IP PBX / SIP wi-fi intercom system installed for 44 Nos of lifts at Arjan Vihar including repair/ replacement of defective parts including servicing of all phones, server and other connected items and make system fully functional complete all specified and directed.
All as per item No 1 but for 35 Nos of lifts installed at Manekshaw Marg and Urban Village.
All as per item No 1 but for 26 Nos of lifts installed at Mohan Enclave
All as per item No 1 but for 46 Nos of lifts installed at Naraina vihar
All as per item No 1 but for 16 Nos of lifts installed at Rangpuri
All as per item No 1 but for 60 Nos of lifts installed at Piru Vihar.
All as per item No 1 but for 05 Nos of lifts installed at DGIS.
All as per item No 1 but for 20 Nos of lifts installed at Baird Place.
Comprehensive maintenance of Digital EPABX Exchange system of 4x4x40 lines installed for 30 Nos of lifts at Carriappa Vihar including repair/replacement of defective parts including servicing of all phones, server,UPS and other connected items and make system fully functional complete all as specified and directed.
All as per item No 09 but for 17 Nos of lifts installed at SP Marg.
All as per item No 09 but for 06 Nos of lifts installed at Toadpur.
Notes for section 1 to 11 :- (i) The Comprehensive maintenance (Section-I) under this contract shall be done through OEM.i.e. any one of M/s Matrix Telecom Solutions/ M/s NEC/ M/s Creative Telecom (P) Ltd/ M/s Core-IP/ M/s SAN Software/ M/s Delhi Tech Services. The contractor is liable to submit MoU on stamp paper of Rs 100/- duly notarized, as per specified Performa (On srl page No. 106 to 108) and copy of Maintenance Contract will be submitted from the OEM within twenty eight days from date of Acceptance of tender. If the delay from OEM side to submit the MoU, the contractor to be submit evidence to the Accepting Officer and permission to be obtained from Accepting Officer for delay in submission of MoU. (ii) Contractor will conclude AMC with OEM and copy of the agreement along with Invoice will be submitted to Engr-in-Charge and GE. (iii) The above maintenance include complete maintenance of existing intercom system by regularly and systematically examining as required for smooth and efficient functioning of the equipment. Cost of all major and minor spares items including cables are deemed to be included in the above rate. (iv) Contractor should send Telephone Mechanic to attend/ rectify the complaints for all the locations during 0800 Hrs to 1800 Hrs as and when complaint is lodged for breakdown on call basis for any No of times during the month. (v) Contractor should rectify the minor defect within 8 hrs and major defect within 24 hrs after receiving the complaint from user/ MES Rep on site including Sundays and Holidays, failing which a penalty of Rs 200/ per complaint per day shall be levied upon contractor. (vi) All minor/ major spare for instrument (i.e. phone hand set, car set type hands free intercom set, steel casing enclosure for telephone set, Battery as required at site and any other parts are deemed to be included with quoted rates. (vii) The contractor deemed to have visited the site and seen the scope of work before quoting the rates. (viii) Monthly Service report duly signed by OEM, contractor to be submitted to deptt, failing which a penalty of Rs 1000/- per individual IP PBX Wi-Fi / EPABX system shall be levied & deducted from running payments of contractor. (IX) OEM will provide ID and password to department as and when required.
Section-II Supply, Fixing, Testing and commissioning in repair of 32Ch 8MP NVR with following specifications including taking down complete all as specified and directed. (a) Supports 32CH 8MP/6MP/5MP/4MP/3MP/ 1080P/1280×1024/ 960P/ 720P/ 960 H/D1/ CIF IP input (b) Standard H.265 and H.264 high profile compression format to get high-quality video at much lower bit rate (c) Multi-mode recording: manual / timed / motion / sensor / POS / AI recording, 16CH simultaneous playback (d) Supports face detection and comparison (e) Supports multiple VCA (Video Content Analytics) events, such as object abandoned/missing, region intrusion, tripwire, video tampering, etc. (f) Express and flexible backup via USB & network (g) Pentaplex : preview, record, playback, backup and remote access (h) Remote control via Web Client or CMS : preview, playback, backup, PTZ and configuration (i) Dual stream technology for local storage with high definition, remote network transmission and remote surveillance with mobile device, Multi-user online simultaneously (j) 4K HD output, true high resolution display (k) DHCP, DDNS, PPPoE network protocol (l) Supports PTZ preset and auto cruise, up to 255 presets and 8 cruises complete Make :- Hikvision/CP plus/TVT/ Vintrone
Supply, fixing, testing and commissioning in repair of 2 MP Dome network camera having following specifications including taking down complete all as specified and directed :- (a) 2 MP H.265 full real time coding, Max. Resolution: 1920 × 1080 (b) 10~ 20m white light view distance, 24/7 full color imaging. (c) 3D DNR, digital WDR, HLC, BLC, defog, 1CH built-in MIC (d) Support dual streams, IP-67 ingress protection complete Make:- Hikvision/CP plus/TVT/Vintrone
Supply, fixing and commissioning in repair of 6TB HDD Surveillance to record the Video Data, 30 Days recordings capacity including taking down complete all as specified and directed :- Make :- WD/Seagate
Supply, fixing and commissioning in repair of 8 Ports PoE network switch at control room to connect the NVR and other equipments including taking down complete all as specified and directed. Make:-D Link /Cisco/Alcatel
Supply, testing and commissioning in repair of 2Mtr CAT6 Patch cords including taking down complete all as specified and directed.
Supply, laying and testing in repair of standard CAT-6 cable for connecting and providing link to camera through existing Wi-Fi network at lift and as req including taking down complete all as specified and directed. Make:- D Link/commscope/AMP
Supply & fixing in repair power supply adapter suitable for provoding power to CCTV camera as per requirement at site including taking down complete all as specified and directed.
Section-III Supply and fixing in repairs of lift car set hand free operated with high gain amplifier intercom set (Telephone) as per sample including taking down complete all as specified & directed. (Make:- Tata/ Panasonic/ Beetal).
Supply and fixing in repairs of stainless steel casing enclouser for (Telephone) lift car set hand free operated with high gain amplifier intercom set with locking arrangment as per site requirement including taking down complete all as specified & directed
Supply, laying and testing of armoured insulated copper cable and sheathed with GI strip/ wire heavy duty telephone cable of size 0.50 mm x 10 pairs fixed on wall/ pole including taking down complete all as specified & directed. Make :- Delton/ Polycab/ D link
Supply, laying and testing of armoured insulated copper cable and sheathed with GI strip/ wire heavy duty telephone cable of size 0.50 mm x 5 pairs fixed on wall/pole including taking down complete all as specified & directed. (Make :- Delton / Polycab/D link.)
Material & Labour for replacement of defective travelling cable PVC insulated flexible flat copper conductor of size 0.5 sqmm 4 core with connected accessories including taking down complete all as per site requirement as directed. Make:- Macrotherm or equivalent
Supply, laying and testing of insulated copper cable telephone wire of size 0.5 sqmm 4 pair fixed on wall/ pole including taking down complete all as specified & directed. (Make :- Delton/Polycab/D link.)
Supply, laying and testing of insulated copper cable telephone wire of size 0.5 sqmm 2 pair fixed on wall/ pole including taking down complete all as specified & directed. (Make :Delton/Polycab/D link.)
Material & Labour in replacement of earthing with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron wire of 4mm dia as earth lead as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick complete all as specified and directed. Note:- (i) Each protection pipe and earthing lead upto and including 7.5 meter length is deemed to be included in the qouted rate of this item.
Supply and fixing in replacement of GI strip 25 x 4 mm and necessary clamps, shaddels, screws complete from machine room equipment to earth pit including taking down of old one or connecting in pieces with old one complete all as specified & directed. Note:- (i) Rate for fixing of earthing strip from earth pit to lift machine room from shaft will be included in the quoted rate.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc to be measured separately) and making good disturbed surfaces of wall floor etc complete all as specified and directed.
Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and directed.
Material & Labour point wiring for normal switches with 1.5 sqmm single core, multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through existing concealed Conduit as requirement of site including cadmium plated screws as per ISI incl replacement of 3 mm thick phenolic laminated sheet top covers on & including sunk type CI/steel terminal boxes concealed in wall including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for one light point controlled by one switch 5 Amps one way single polecomplete all as specified and directed. Make:- Havells/ Finolex/ Standard.
All as per item No. 31 above but one three pin 5 Amps socket out let on independent board.
All as per item No. 31 above but one three pin 5 Amps socket out let on same board.
All as per item No 31 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 sqmm size of earth conductor complete all as specified and directed. Make:- Havells/Standard /Finolex
Material & Labour in replacement of unsv one with new submain wiring with two single core 4 sqmm PVC insulated FRLS multistrand copper conductor cable drawing into and including rigid non metallic PVC casing caping ISI marked with all fittings & fixing accessories and one single core 2.5 sqmm FRLS multistrand copper conductor cable as continuous earth wire complete all as specified & directed. Make:- Polycab/ Finolex /Havells
Material & Labour in replacement of unsv one with new submain wiring with two single core 6 sqmm PVC insulated FRLS multistrand copper conductor cable drawing into and including rigid non metallic PVC casing caping ISI marked with all fittings & fixing accessories and one single core 4 sqmm FRLS multistrand copper conductor cable as continuous earth wire complete all as specified & directed. Make:-Polycab/ Finolex /Havells
Supply & fixing in repair Switch Piano type, white polycarbonate body, single pole, one way 5 Amp 230V including connecting complete all as specified & directed. Make :- Anchor/Cona/Legrand
Supply and fixing in repair socket combination white polycarbonate body, 6A - 230 V Multipurpose, including connecting complete all as specified & directed. complete all as specified & directed. Make :- Anchor/Cona/Legrand
Supply and fix in repair switch white polycarbonate body, 16A- 230 V, 2/3 pin combined, including connecting complete all as specified & directed. Make :- Anchor/ Cona/ Legrand
Supply and fix in repair socket white polycarbonate body, 6A/16A- 230 V, 2/3 pin combined, including connecting complete all as specified & directed. Make :- Anchor/ Cona/ Legrand
Supply & fixing Switch socket combination box piano type 2in 1, 3 pin, 6/16 Amp flush type universal complete all as specified and directed. Make :- Anchor/Havells/SSK.
Supply & fixing in repair distribution board (DB) double door (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make :- Legrand / Havells/Siemens / Schnieder.
Supply & fixing in repair distribution board (DB) double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make :- Legrand / Havells/Siemens / Schnieder.
Supply & fixing in repair MCB SP 240 Volts, 6-32 Amps complete all as specified and directed. Make:- Make-Legrend/Schnieder/Havells
Supply & fixing in repair MCB SPN, 240 Volts, 6-32 Amps complete all as specified and directed. Make:- Havells/Legrend/Schnieder
Supply & fixing in replacement of energy efficient Surface/Wall Mounted 20W integrated LED batten 4 feet fitting with polycarbonate housing total system Lumen should be 2200 or above in Cool day Light (5700K to 6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>110 Lm/w, THD(%) < 20, LED Lamp LED Lamp Efficacy>130 Lm/W with Average life of 50000 Burning hours complete with all accessories as required for connections including taking down complete all as specified and directed. Make :- Havells/Wipro/Philips.
Supply & fixing in replacement energy efficient LED batten tube light, Surface/Wall Mounted 9W to 10W integrated LED 2 feet Fitting with polycarbonate housing total system Lumen should be 990 or above in Cool day Light (5700K to 6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>110 Lm/w, THD(%) < 20, LED Lamp, LED Lamp Efficacy>130 Lm/W with Avg life of 50000 Burning hrs Complete with all accessories as required for connections including taking down complete all as specified and directed. Make :- Havells/ Wipro/ Philips.
Supply & fixing in repair LED bulkhead 10 watt cap including taking down complete all as specified and directed. Make :- Wipro/Havells/ Philips
Supply & fixing maintenance free sealed LED acid battery of cap-12V 18AH for lift ARD for any make and model of lifts including taking down complete all as specified and directed. Make:- Exide /Amaron / Standard Furkkava
Supply & fixing maintenance free sealed LED acid battery of cap 12V 7/9 AH for lifts ARD of any make including taking down complete all as specified and directed. Make:- Exide /Amaron / Standard Furkkava
Supply & fixing maintenance free sealed LED acid battery of cap 12V 12 AH for lifts of any make including taking down complete all as specified and directed. Make:- Exide /Amaron / Standard Furkkava
Supply and fixing of exhaust fan heavy duty of size 300 mm sweep, motor speed 900 rpm power consumprion70 W, 230 V, 50 Hz with complete louver of rust proof metal body including making hole of suitable size including all accessories such as suitable size of fasteners, flexible wires for connections, testing, assembling and making good disturbed surfaces of wall including taking down of old unserviceable one complete all as specified and directed. Make - Havells / CG / Usha / Khaitan
Material & Labour for shifting of LT Servo voltage stabilizer of any capacity from lift machine room to AGE E/M LIFT store yard comptele including the following works- (a) disconnecting of electrical connection.(b) Discoonecting of earthing strip complete all as specified and directed by Engr in charge.(c) Making all connection proper after completion of work. complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .