| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC 2ND 6 KEDIA HOUSE MA ROAD BYELANE 1 REHABARI GUWAHATI ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹27.3 L+₹68,074 (2.56%)Rejected-Finance H M APARTMENT FLAT NO 5C SJ ROAD ATHGAON GUWAHATI 781001 ASSAM | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹29.2 L+₹2.6 L (9.78%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
24 Jan 2022, 6:00 pmClosed
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
SPECIAL REPAIR/REPLACEMENT OF WATER SUPPLY EQUIPMENTS AGAINST BER AT DINJAN MIL STN
2021_MES_495942_1
83059E8
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
180 days
GE DINJAN
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE DINJAN
₹60,000
Yes
24 Feb 2022
18 Dec 2021
31 Jan 2022
18 Dec 2021
24 Jan 2022
11 Jan 2022
20 Dec 2021 - 30 Dec 2021
Amount
Supplying, installing, testing and commissioning silent diesel engine driven generating set 125 kVA /100 kW (prime power), 415 volt, 50 Hz, 3 phase, 4 wire, at 1500 rpm, 0.8 lagging power factor including diesel engine multi cylinder, 04 stroke, alternator, coupling, common base plate, acoustic enclosure, 12 V DC battery, Outdoor type AMF Panel. Exhaust system, foundation etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Supply, installation, testing and commissioning of 4 inch stainless steel submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm) supply and Install complete 15 HP, and 720 LPM at 44 m head all as specified and directed. Make :Make as mentioned under Appendix "B" complete all as specified and as directed.
Supply, installation, testing and commissioning of 4 inch stainless steel submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm) supply and Install complete 25 HP, 1140 LPM at 67 m head, all as specified and directed.
Supply, installation & Fixing Monoblock Centrifugal Pump Hi Flow self priming type of 5 HP Capacity, including PCC foundation complete all as specified and directed.
Supply, installation, testing and commissioning monoblocks centrifual pump along with 10 HP electric driven motor, 415 volte, 3 phase AC, TP, head range 33-54 metres, flow rate 200-450 LMP, 3000 RPM, including PCC foundation complete all as specified and directed.
Supply, installation, testing and commissioning monoblocks centrifual pump along with 1 HP electric driven motor, 415 volte 3 phase AC, TP, head range 33-54 meter, flow rate of suitable range as per manufaturer instructions, 3000 RPM, including PCC foundation complete all as specified and directed..
S & F DOL starter 3 HP, 415V, 50 Hz. For Air compressor and air blower with all fitting accessories all as specified and as directed by Engr-in-Charge
S & F in in repairs fully automatic star-delta starter in open execution suitable for 415V, 3ph,, for 25 HP with SPP feature, with relay range 9-15 amps, for centrifugal/submersible pump set including taking out old unserviceable one.
S & F in in repairs fully automatic star-delta starter in open execution suitable for 415V, 3ph,, for 15 HP with SPP feature, with relay range 9-15 amps, for centrifugal/submersible pump set including taking out old unserviceable one.
S & F in in repairs fully automatic star-delta starter in open execution suitable for 415V, 3ph,, upto 10 HP with SPP feature, with relay range 9-15 amps, for centrifugal/submersible pump set including taking out old unserviceable one.
S & F submersible cable flat PVC insulation of type C and having PVC sheath of type ST2, flexible copper conductor, FR-LSH, 3 core of size 16 sqmm complete all as specified and as directed.
S & F submersible cable flat PVC insulation of type C and having PVC sheath of type ST2, flexible copper conductor, FR-LSH, 3 core of size 10 sqmm complete all as specified and as directed.
S & F in repairs submersible cable flat PVC insulation of type C and having PVC sheath of type ST2, flexible copper conductor, FR-LSH, 3 core of size 6 sqmm complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 100 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in trenches 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in trenches 40 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in trenches 50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in trenches 80 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 80 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 100 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
S & F 25 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F 40 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F 50 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
supply and lay MS pipe heavy grade with all fittings laid in floor or fixed to the walls or celling of size 80 mm bore including taking down of old u/s pipe from any position all as specified and directed
M & L for flanged reflux valves(ISI Marked) of single door, swing check type (non return valves) of nominal pressure (PN 1.6) as per IS 5312 (Part 1): 2004, nominal size 50 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
M & L in repairs flanged reflux valves(ISI Marked) of single door, swing check type (non return valves) of nominal pressure (PN 1.6) as per IS 5312 (Part 1): 2004, nominal size 80 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
S & F flanged reflux valve (non-return) of single door, swing check type nominal pressure (PN 1.6) of preferred materials as per IS 5312 (Part 1): 2004, nominal size 100 mm complete all as specified and as directed.
S & F flanged reflux valve (non-return) of single door, swing check type nominal pressure (PN 1.6) of preferred materials as per IS 5312 (Part 1): 2004, nominal size 80 mm complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply. Install, testing and comissioning chemical dozing system model NoEC-11/RPQ-40 of RMCO or equivalent make as given in Appx B with suction and discharge pipe, foot valve, injection check valve including agitator tank of capacity 100 ltrs with taking down unserviceable one complete all as specified and as directed.
M/s JK Jangid and Company
M/s GOURAB JYOTI GOGOI
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .