Loading…
Loading…
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
13 Jul 2026, 5:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (WMS)
TOWNSHIP
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited : (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre- defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. see further details tender documents.
Similar Nature of Work: It is defined as: The firm should have carried out the work of 'Supply, Erection, Testing & commissioning of wiring/Re- wiring of Qtrs./Service buildings along with repair/rectification of HT/LT Panels/Pump Panels/Feeder Panels etc. ' 'OR' 'Supply, Erection, Testing & commissioning of HT/LT cabling work along with HT/LT paneling.' 'OR' AMC/Electrical maintenance work of Service Buildings/ Residential Colonies including maintenance of HT/LT panels/cabling work/ pump installation / air conditioning system etc. 'OR' Zone Electrical works performed by any firm in railways.
Electrical Contractor License: Tenderer(s) have to submit a copy of valid electrical contractor license for carrying out installation work of voltage class involved, issued by any state/central government along with the tender documents, failing which the offer is liable to be rejected.
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Repair and Maintenance work in Township Area (2026-27) in Rail Coach Factory, Kapurthala.
RCF-EL-TS-ET-153-2026-27
RCF-EL-TS-ET-153-2026-27
Open
Works - General
12 Months
Kapurthala, Punjab
₹0
₹2.1 L
13 Jul 2026
22 Jun 2026
29 Jun 2026
146 items across 12 schedules · ₹1,04,50,506.52 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply wiring of size 2x1.5 sq mm (Red + Black) copper multi strand wire along with 1x1.0 sq. mm multi strand green colour copper wire as earth, and drawing through (inside the pole) the street light pole testing & commissioning the wire to replace the burnt/damaged wiring in the poles from light fixture to the junction box fitted at the bottom of the 9.5/11.5 meter long poles as per explanatory notes. | Set | 60.00 | 620 | 37,200 |
| 2 | Supply and fixing of GI pipe bracket of 40mm dia 2.0 mtr long with a suitable bend and fixing o n the Wall/roof top with GI Clamps and fixing the street light fitting (fitting will provided by RCF) . It also Includes the 2x1.5 sq. mm copper wire along with 1x1.0 sq. mm green wire as earth wire along with MCB 10Amp/ switch box with 16amp switch as per explanatory notes. | Numbers | 100.00 | 566 | 56,600 |
| 3 | Dismantling of existing broken muffing and fabrication of new muffing having size 450mm outer dia. and 165mm inner dia. approx. and 600mm height with concrete mixture having ratio 1:3:6 and giving proper and smooth finishing to the muffing surface with plastering and top to be tapered as per pole foundation drawing as per explanatory notes. | Numbers | 40.00 | 517 | 20,680 |
| 4 | Supply and fixing of GI pipe pole arm of dia 65mm with nipple of dia 40mm on top of exiting street light pole including primer and aluminium shade paint work .This work includes drawing of existing copper wire 2x1.5sq.mm inside pole & refixing of street light with proper conn. as per explanatory notes. | Numbers | 10.00 | 1,498 | 14,980 |
| 5 | Supply of paint and painting the poles 9.5 mtr/11.5 mtr long with two coats of silver paint of Make Asian/Berger/Nerolac /Dulux . The surface of poles shall be cleaned properly and smoothly by emery paper & one layer of red oxide before repainting the poles. (High Rise platform vehicle will be provided by RCF for painting high Top (Bend arm) of poles free of cost). Each pole is to numbered again with black paint letters and digits of same dimensions as written on existing poles as per explanatory notes. | Numbers | 50.00 | 365 | 18,250 |
| 6 | Supply of paint and painting the poles 9.5 mtr/11.5 mtr long with two coats of silver paint of Make Asian/Berger/Nerolac /Dulux . The surface of poles shall be cleaned properly and smoothly by emery paper & one layer of red o x i d e before repainting the poles. (Wooden Ladder/suitable high rise plate form which does not damage the grass of Golf area.) Each pole is to numbered again with black paint letters and digits of same dimensions as written on existing poles as per explanatory notes. | Numbers | 25.00 | 410 | 10,250 |
| 7 | Painting of muffing of street light poles/Post top light pole of white colour with one coat of outdoor weather proof paint of Asian/Berger/nerolac/ Dulux after repair of muffing properly with Cement & white Putty. ( 02 muffling's of post top light pole will be counted as one large street light pole muffing for measurement) as per explanatory notes. | Numbers | 25.00 | 313 | 7,825 |
| 8 | Supply the paint and painting the small poles of height approx. 3.0mtr/5.0 mtr/5.5 mtr long with two coats of silver/white paint of Asian/Berger/nerolac/ Dulux. The surface of poles shall be cleaned properly and smoothly with use of emery paper & one coat of red oxide paint before repainting the poles. Each pole is to numbered again with black paint letters and digits of same Dimensions as written on existing poles as per explanatory notes. | Numbers | 25.00 | 365 | 9,125 |
| 9 | Supply, fixing, testing and commissioning of End terminations (only thimbles) & heat shrinkable sleeves of existing cables of size 4x25 sq. mm /4x16 sq. mm XLPE cables to be provided aluminium reducer terminals (Thimbles/lugs) to be crimped properly and fixing in the brass terminals of junction boxes as per explanatory notes. | Numbers | 100.00 | 6 | 600 |
| 10 | Supply, fixing, testing and commissioning of Astronomical Timer for replacement of defective timer in SFP/MFP or as per site requirement and details as per explanatory notes. | Numbers | 5.00 | 3,758 | 18,790 |
| 11 | Supply, fixing, testing and commissioning of street light junction boxes of stainless steel SS- 304 sheet 1.6 mm thick duly powder coated complete with SS-304 clamps of 3mm thickness, 2mm thick sheet hinges of stainless steel only on the street light pole as per RCF Drawing RCF/EL/TS/JB/01-05/01 Rev 1 with "PTPN63"4POLE TERMINAL PAD 63A ON of street light junction box. Note:- Earth connection should be properly connected to Jn. box with use of copper thimble & connection to armoured wires as per explanatory notes. | Numbers | 150.00 | 2,888 | 4,33,200 |
| 12 | Supply of paint and painting the Sub feeder Pillar (SFP) with the help of compressor gun after rubbing off the old paint completely with emery paper and providing 1 coat of primer and 2 coats of enamel paint of grey colour of Berger/Dulux/Nerolac/Asian as per explanatory notes. | Numbers | 25.00 | 1,137 | 28,425 |
| 13 | Supply of paint and painting of Main feeder Pillar with the help of compressor gun after rubbing off the old paint completely with emery paper and providing 1 coat of primer and 2 coats of enamel paint of grey colour of Berger/Du lux/Nero lac/Asian as per explanatory notes. | Numbers | 10.00 | 1,757 | 17,570 |
| 14 | Supply, fixing, testing and commissioning of Small size Junction boxes ( for approx. 3.0mtr/5.0 mtr/5.5 mtr long poles) of stainless steel SS-304 sheet 1.6 mm thick duly powder coated complete with SS-304 clamps of 3mm thickness, 2mm thick sheet hinges of stainless steel only on the street light pole as per Drawing approved by Dy. CEE/PS of small pole (Low height) junction box with standard connecting plates "PTPN" 4 pole terminal pad 63 A as per approved RCF design. Note:- Earth connection should be properly connected to Jn. box with use of copper thimble & connection to armoured wires as per explanatory notes. | Numbers | 50.00 | 1,890 | 94,500 |
| 15 | Supply, fixing, testing and commissioning of outdoor Cubical Panel with double door with top canopy of CRCA Sheet of thickness 14 Gauge duly powder coated of Siemens gray of approx. Size 650mmx 600mm and 250mm deep along with suitable stand of MS angle of height 600mm minimum to be grouted 300 mm inside the ground with concrete ratio of 1:3:6 along with two Nos of MCCB TPN of 125 Amp with breaking capacity 25kA , 03 nos. loop in loop out terminal (04 points) capacity 200A each . The details of item working shall be carried out as per explanatory Notes. | Numbers | 7.00 | 19,648.8 | 1,37,541.6 |
| Schedule total | ₹9,05,536.6 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender documents
ATTACHMENT
RCF-EL-TS-ET-153-2026-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .