GE (AF) JORHAT
JORHAT
REPAIR/MAINT AND AMC OF FIRE ALARM SYSTEM AND FIRE FIGHTING ALONGWITH VARIOUS CONNECTED ITEMS AT AFS UNDER GE (AF) JORHAT
2026_MES_782768_1
8814/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE (AF) JORHAT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹60,000
Yes
5 Aug 2026
5 Aug 2026
28 Aug 2026
5 Aug 2026
26 Aug 2026
20 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, laying and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq.mm, 2 core 1100 volts grade complete all as specified and as directed. | 380 | Rm | - | - |
| 2 | Supply, installation, testing and commissioning analogue addressable fire alarm control panel with 2 loop capacity having minimum 99 detector and 99 modules, 32 bit dual core microprocessor with 5 inch multi colour touch display annuciation to indicate power, alarm silenced, trouble, system trouble, disabled, test, supervisory, delay, audio alarm with push buttonb for acknowledge test reset complete with power supply of 24 DC suitable AH and 230 volts and back with a maintenance free battery backup system with the glowing and connecting up complete all as specified and as directed. | 4 | Each Job | - | - |
| 3 | Supply, installation, testing & commissioning repeater annuciator panel with backlit, 80-character LCD fire annunciator that mimics the fire alarm control (FACP) display, provides system status indicator for ac power, alarm, trouble, supervisory and alarm silenced conditions. the repeater and the FACP communicate over a two wire serial interface employing the repeater-bus communication format, connected devices are powered via two additional wires by either the host FACP. the repeater display in english language text of system point information including device type, zone, independent point alarm, trouble or supervisory status as well as any custom alpha labels programmed into the control panel. it includes control switches for remote control of critical system functions (a key switch prevents unauthorized operation of the control switches) and connecting up, complete all as specified and as directed. | 3 | Each Job | - | - |
| 4 | Supply, installation, testing & commissioning Addressable Type Fire Alarm Sounder/Siren Electronic cum strobe type Horizontal Single Stage Continuous Normal Operation for atleast 50 minimum with sound level 65 db to 120 db measured at 1.50 metre with sound output variation +5 db 3500 metre range and connecting up complete all as specified and as directed. | 7 | Each | - | - |
| 5 | Supply, installation, testing & commissioning addressable type of Intelligent Loop Isolator with Mounting Base complying with EN-54 standard and LPCB approved with the specifications and connecting up complete all as specified and as directed. | 7 | Each | - | - |
| 6 | Supply, installation, testing & commissioning addressable type of Manual Call Point, Resettable type and connecting up complete all as specified and as directed. | 9 | Each | - | - |
| 7 | Supply, installation, testing & commissioning detector complying with and type certified to EN-45 Analogue addressable type multi-sensor detector with Heat and Smoke Combination Photoelectric/Optical with base with self built intelligence as per IS-11360 and connecting up complete all as specified and as directed. | 70 | Each | - | - |
| 8 | Supply, istallation, testing & commissioning indoor detector complying with and type certified to EN-54 addressable type Flame Detectors with UV and IR detection capacity (Add up cost of module to be a complete set, the type of module shall be Relay Type Module) with self built intelligence and connecting up complete all as specified and as directed. | 4 | Each | - | - |
| 9 | Comprehensive service/repair/maintenance and monthly visit for regular maintenance for the automation of intelligent addressable fire alarm control panel including checking testing and cleaning of loop card, main board, LCD display, Multisensor, sounder, MCP, Repeater Panel, Zone monitor Module, UV & IR detector, Remote Response indicator, Loop Isolator, Amplifier and Loud speakers carrying out normal repairs for the trouble free and efficient functioning of the entire fire alarm system by providing one engineer for Monthly visit complete all as specified and as directed and as specified NFPA 72 and Guidelines.
Locations : CCR, Rt Cabin, Tech Flat Hanger, Butller Hanger, GCA Building, AFNET Building, Common IT Building, Armoury, IL Hanger, 49 SQN Hanger, 43 Sqn Hanger, BCR Building, SRE Building Logistic Section, Base Ops, 736 S&U, Signal Section, Avionic Lab
Notes:- (i) Cost of new components shall be paid for separately under relevant items of schedule 'A"
(ii) Contractor's rep will visit minimum once in a month to every panel each location as mentioned above and take serviceability certificate duly signed by the user. | 11 | Each Job | - | - |
| 10 | Dismantling, servicing of multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer's instructions and testing for exact fault locations including cleaning through air blower then reinstalling every six month complete all as specified and as directed | 280 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
8814tender.pdf
Tender Documents • 1.08 MB
BOQ_876985.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].