Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.9 LAccepted-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC L1 BIDDER FOUND REASONABLE | |
| 2 | L2₹87.9 L+₹17.0 L (24.0%)Rejected-Finance 1630 SECTOR 7 C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | L2 | Rejected-Finance HIGEST RATE QOUTED BY BIDDER |
Tender Value
₹66.0 L
EMD Value
₹1.3 L
Closing Date
28 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JAISALMER
HQ CWE AF JAISALMER
INTEGRATION OF COMMERCIAL POWER SUPPLY IN TECHNICAL AREA AT AIR FORCE STATION JAISALMER
2022_MES_571294_1
80224/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF JAISALMER
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE AF JAISALMER
₹1.3 L
Yes
21 Feb 2023
26 Dec 2022
30 Jan 2023
26 Dec 2022
28 Jan 2023
16 Jan 2023
Amount
Excavating in trenches in soft/loose soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, for pipes and electric cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as speified and as directed.
Excavating in trenches in hard soil., n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, for pipes and electric cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as speified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm any type of soil complete all as speified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point for soil complete all as speified and as directed.
M&L for providing dry tibba sand in trenches as sand cushioning to underground cable including punning down of sand in layercomplete all as speified and as directed. (Note :- 18 cm punned thickness shall only be reckoned for the purpose of measurement and payment).
M& L for 40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable complete all as specified and directed.
Supply, lay and fix 100 mm bore galvanised iron pipe with all fittings as protection for electric cables, laid in trenches, fixed on poles, walls and ceilings or laid in floors, laid in road crossing /hard standing/pole protection fixed with clamps as per site requirement etc complete all as specified and as directed.
Supply, lay, joint, test and commission HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured overall PVC sheathed electric power cable heavy duty with aluminium conductor of size 3 core 95 sqmm cross sectional area, 11000 Volts grade Earthed (11 KV earthed system), laid in trenches, fixed on walls, roofs and poles, laid in ducts and floors etc complete all as specified and directed. Note : Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid for separately under respective items of BoQ
Supply, lay, joint, test and commission LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured overall PVC sheathed electric power cable heavy duty with aluminium conductor of size 3.5 core 400 sqmm cross sectional area, 1100 Volts grade, laid in trenches, fixed on walls, roofs and poles, laid in ducts and floors etc complete all as specified and directed. Note : Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid for separately under respective items of BoQ
S&F Heat shrinkable outdoor termination joint suitable for HT XLPE cable of size 95 Sqmm 3 core armoured 11000 Volts grade heavy duty complete all as speicified and directed by Engineer-in-Charge
S&F Heat shrinkable indoor termination joint suitable for HT XLPE cable of size 95 Sqmm 3 core armoured 11000 Volts grade heavy duty complete all as speicified and directed by Engineer-in-Charge
M&L for Earthing complete with galvanised iron earth electrode 60cm x60cm x6.0 mm thick burried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connecting to the galvanised iron earth strip of size 32x6 mm, by means of nuts, bolts, check nuts and washers etc of galvanised iron and earth lead protected by provision of 40mm bore GI pipe medium grade from earth electrode to test point including pron of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4kg/sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, 20mm bore GI pipe light grade pipe for watering perforated at bottom 1.75m long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning in and removal of surplus soil to a distance exceeding 50m, complete all as specified in electrical plate No. 3 of SSR Part-1 and connection to earth test point including testing on completion as directed. Note : The cost of 7.5m long galvanised iron earth strip 32x6mm size and protection pipe of 40mm bore GI medium grade is deemed to be included in quoted unit rate.
S&F change over switch 630 Amps ON load type in mild steel sheet enclosure four pole to be fixed on wall with mounting arrangements using equal angles as directed at site in and including, nuts, bolts, washers etc. with all electric connection complete all as specified and directed.
Suuply, fix, commission and test Ative Harmonic Filter (AHF) 3 Phase, 4 wire Dynamic Correction of TDH improvement of distortion and displacement, 14% third harmonics mitigation. Detuned harmonic filters are the series combination of reactor and power capacitor. This filter offers higher impedance for high frequency harmonics. This prevents harmonic resonance and amplification, stand alone module unit with HMI rating 300 Amps with provision for future and option of closed loop as well as open loop sensing complete all as directed.
Design, supply, erection, commission and test LT Feeder Pillar Box, factory made, weather, dust and vermin proof; indoor type, double door, suitable for 3 phase 4 wire, 415 Volts AC supply and having 4 Nos Copper bus bars not less 1200 Amps for distribution system and type tested at CPRI, fabricated in factory having modern fabrication and testing facility which includes seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032.The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA (Cold Rolled Close Annealed) sheet and 3.15mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and mild steel channel (75 MC) base frame at bottom and having 4 Nos welded equal angle of 75mmx75mmx6mm of length 0.9m, 30cm of angle iron shall be embedded in PCC (1:2:4) type B-1 using , 20mm graded stone agregate below GL level and 30cm shall be above ground level of size as directed by Engneer-in-Charge at site. The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. Necessary cable gland shall be provided for all incoming and outgoing cables. The feeder pillar shall be comprising of the followings and all as shown in drawings :- CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-stranded type copper wire of cross sectional area 1.5Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
INCOMING : ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps, 50 KA -01 Nos OUTGOINGS : (a) MCCB 4 Pole 630 Amps, 415 Volts, 50 Hz rupturing capacity 50 KA, electronic release, Adjustable type 70-100 % with connecting links -02 Nos (b) Bakelite fuse holder with 5 Amps HRC type control fuse - 03 Nos. (c) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No. (d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 No. (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 800 Amps, accuracy class 1% - 01 No. (f) Current transformer (CT) of rating 800/5, tape wound, rated burden 5 VA - 03 Nos. (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (h) Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber. 02 Nos. (Note : 1. The feeder pillar Box shall be designed in such a way that adequate workable space is made available inside the compartments and the front area of the panel shall not be less than 1.5 sqm and 500mm depth). 2. The contractor shall submit design and drawing for LT panel feeder pillar box to the Garrison Engineer for approval before procurement of material.
Design, supply, erection, commission and test LT Feeder Pillar Box, indoor type, weather/dust/vermin proof, double door, factory made suitable for 3 phase 4 wire, 415 Volts AC supply and having 4 Nos Copper bus bar not less 1200 Amps for distribution system and type tested at CPRI, fabricated in factory having modern fabrication and testing facility which includes seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA (Cold Rolled Close Annealed) mild steel sheet and 3.15mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and mild steel channel (75 MC) base frame at bottom and having welded 04 Nos equal mild steel angle iron of size 75mmx75mmx6mm of length 0.9m, 30cm of of angle shall be embedded in PCC (1:2:4) type B-1 using 20mm graded stone agregate below GL level and 30cm shall be above ground level of size as directed by Engineer-in-Charge at site. The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. Necessary cable gland shall be provided for all incoming and outgoing cables. The feeder pillar shall be comprising of the followings and all as shown in drawings :- CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-stranded type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
INCOMINGS : ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps, 50 KA -01 No. OUTGOINGS : (a) MCCB 4 Pole 630 Amps, 415 Volts, 50 Hz rupturing capacity 50 KA, electronic relase, Adjustable type 70-100 % with connecting links -02 Nos (b) Phase sequance corrector -01 No (c) Commercial/Main supply failure alarm/hooter with connected wiring complete-01 Set (d) Bakelite fuse holder with 5 Amps HRC type control fuse - 03 Nos. (e) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No (f) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos(g) Digital Ammeter 96mm x 96mm suitable to read 0 to 800 Amps, accuracy class 1% - 01 Nos (g) Digital Ammeter 96mm x 96mm suitable to read 0 to 800 Amps, accuracy class 1% - 01 No. (h) Current transformer (CT) of rating 800/5, tape wound, rated burden 5 VA - 03 Nos (j) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (k) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber. (Note : 1. The feeder pillar Box shall be designed in such a way that adequate workable space is made available inside the compartments and the front area of the panel shall not be less than 1.6 sqm and 500mm depth). 2. The contractor shall submit design and drawings for LT panel Feeder Pillar box to the Garrison Engineer for approval before procurement of material.
(v) Capacitor 02 KVAr ultra heavy duty 440V cylindrical - 05 Nos(vi) MCB Triple pole 125 Amps, 10 kA, 'C' sries - 02 Nos(vii) MCB Triple pole 63 Amps, 10 kA, 'C' sries - 02 Nos(viii) MCB Triple pole 40 Amps, 10 kA, 'C' sries - 02 Nos(ix) MCB Triple pole 16 Amps, 10 kA, 'C' sries - 04 Nos(x) MCB Triple pole 10 Amps, 10 kA, 'C' sries - 05 Nos(xi) Capacitor duty contactor 3 pole 50 KVAr - 02 Nos(xii) Capacitor duty contactor 3 pole 20 KVAr - 02 Nos(xiii) Capacitor duty contactor 3 pole 15 KVAr - 02 Nos(xiv) Capacitor duty contactor 3 pole 05 KVAr - 04 Nos(xv) Capacitor duty contactor 3 pole 02 KVAr - 05 Nosxvi) 22.5mm dia Push Button ON/OFF-15 set(xvii) 22.5 mm dia LED Red - 15Nos(xviii) 22.5mm dia LED Green-15 Nos(xix) Armoured 2 core copper cable 1.5sqmm shall be provided for sensing CT(xx) Sensing CT as per site load condition shall be provided alongwith APFC Panel(xxii ) All power connection shall be done with 1100 volts FRLS copper flexible wire with copper termination of proper size and proper type
Supply , instal, commission and test Stepdown Transformer 400 KVA capacity, AC 3 phase, 50 HZ , indoor type 11000/433 Volts(at no load), as per IS-2026, copper wound, ONAN, oil cooled, oil immersed with oil tank and filled with ISI marked insulating oil (IS-335) up to the top level in oil tank with oil level indicator, Breather assembly with silica gel, lifting hook, drain valve, air vent valve , wheel with channel and locking arrangement to put on the plinth with external cooling tubes, core type, delta star connected in accordance with vector symbol DYN-11(vector group-4) with neutral brought on (LV) side & having tapppings in 7 steps in equal steps of 2.5%, (Plus/Minus 7.5 % on plus and minus side to vary the secondary voltage primary side by means of hand operated off load tap changing gear, so as to change/correct HV voltage on secondary side including provision of all necessary /standard fittings including all jointing materials, connecting with electrical system, earthing, testing and commissioning all as conforming to Level -1, IS 1180 (Pt-I)/2014 and mainly comprising of :- (a) One cable end box on HV side having cable glands suitable for 95 sqmm 3 core XLPE 11 KV HT cable (consisting of 3 Nos porcelain H.T bushings with brass/gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porclain bushings with GM bushing rods complete with GM nuts, and washers and suitable size extended copper bus bar strip for connecting of 400sqmm 3.5 core cable with two No cable gland suitable for reception of 1 run of INCOMING LT PVC sheathed armoured cables of size 400 sqmm 3.5 core (c) Oil conservator with filter type, drain valve and oil level gauge. (d) Dehydrating breather assembly with first fill of denydrating agent.
(e) Explosive vents. (f) Thermometer pocket on tank cover. (g) One temperatoure indicator 150mm dia with alarm and trip contact, and one winding temperature indicator with alarm and trip contact with marshalling box and connector in and including providing of suitable core control cable, armoured to connect Marshalling box to RMU/VCB complete and testing on completion (h) Rating plate owith terminal markings. (j) Two earthing terminals on tank /tank cover to facilitate fixing of 32x 6m GI earth strip. (k) Oil level guage. (l) Oil drain and filter valves. (m) Oil filter hole with cap /plug wityh connections complete. (n) Lifting lugs. (o) Air relief valve plug. (p) Four plan solid cast steel detachable rollers. (q) First fill of fresh oil conforming to relvant IS and testing upto 40 KV dielectric strength. (r) Extra bushing for neutral outside the LT cable box for providing independent earthing for neutral (s) Buchholz relay with alarm and trip contact and shut off valves and connecting to marshalling box or RMU/VCB for making Buchholz functional complete. (t) Provision of 2 Nos of danger boards 250x200 mm size made out of 1.6 mm thick MS plate , vitreous enameled white, with letters, figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (u) Any other fittings/accessories so as to conforming to Level -1, IS 1180 (Pt-I)/2014. (v) PCC plateform as directed by Engr-in-charge for mounting of transformer
Supply, instal, commission and test Transformer 400 KVA capacity, indoor type, oil cooled isolation , three phase metalic body, unbalanced type copper wound with standard fittings and accessories, input voltage of 415 Volts +5% output voltage 415 Volts + 5 % of frequency 50Hz and with the following description including first fill of transformer oil as per requirement in and including the following specifications :-
(a) Method of cooling - Oil cooled.(b) Ratio - 1:1(c ) Insulation class- Class - E(d) Winding Temperature - Less than 55 degree centigrade(e) Full Load lossess - Less than 5%(f) No load lossess- Less than 0.5%(g) Mounting : On wheel detachable type(h) Earth to Neutral voltage - Less than 01 Volt(j) Common mode noise rejection over 100db(k) Coupling capacitance : - Less than 1 Pf(l) Insulation level : More than 100 Meg ohms(m) Breakdown strength : 2500V AC for 2 minutes(n) Load regulation : About 3.5%(o) Line leakage current : Less than 50 micro amps upto 1 KVA
Supply, installation, commissioning and testing of servo voltage stabilizer suitable for indoor installations (Conforming to BIS-9815:1994) for automatic operation , three phase, naturally oil cooled, copper wound, metalic body duly powder coated with lifting hooks 02 Nos, digital display type relay free smooth and silent operation outdoor type of capacity 400 KVA complete all as specified and directed in and including following specifications :-
(i) Applicable standard - IS 9815:1994(ii) Input voltage range 300-480 volts 3 phase, 50Hz 4 wire & earth(iii) Output voltage - 415(Plus/Minus)-01% VAC accuracy, 3 phase, 50 Hz 4 wire & earth(iv) Line regulation - Line to load regulation 1 %(v) Type of Load- Three Phase unbalanced type(vi) No distribution in wave form(vii) Correction range-8V/Sec for single phase and 13V/Sec for phase to phase(viii) Efficiency- Above 95%(ix) Response time not to be exceed 20 mili second(x) Noise level - <55 db at a distance of 1 mtr(xi) Monitoring and electronic circuit- Microprocessor controller and DSP base electronic card with inbuilt LCD display, input L/L and L/N voltage monitoring, output L/L and L/N voltage monitoring, Load current phase wise monitoring, input line indication(xii) Protection - Input 3 pole MCCB with shunt release coil for high/low voltage protection and overload and short circuit protection, output 4 pole change over switch for by pass, 10 sec on time delay, RF filter, spike booster reverse phase protection, single phasing protection, earth protection & netrual protection curcuit, spike & surge protectionNote : 1. Amount for 1st filling of transformer oil upto level is deemed to be included in unit quoted ratesNote : 2. Necessary addition/altn if required at site for mounting/Placement of stabilizer is deemed to be included in unit quoted rates, Cost of foundation/plateform with necessary earth work for mounting of stabilizer as per manufacturer's recommendations is deemed to be included in unit quoted rates
SAGGI ELECTRIC COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .