Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC RZ 14D 2ND FLOOR GALI NO 5 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L1 | Accepted-AOC Lowest tender | |
| 2 | L2₹2.9 L+₹2,400 (0.84%)Rejected-Finance RZ 40 PALAM VIHAR DWARKA SECTOR 6 NEW DELHI 75 | NEW DELHI | DELHI | 75 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹2.9 L+₹3,500 (1.22%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹2.9 L+₹6,000 (2.09%)Rejected-Finance WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
Closing Date
6 Apr 2024, 6:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
PROVISION OF 8 INTO 2 POINT 0 TR SPLIT TYPE ACS AND SHIFTING GAS FILLING OF 11 SPLIT TYPE ACS FOR ENVIRONMENT CONTROL AT BLDG NO 129 IST FLOOR ODD WARDEC BLDG DGIS COMPLEX UNDER GE U P M DELHI CANTT
2024_MES_648298_1
GE(U)/PM/3011/B/JO/139/E3
Limited
Miscellaneous Works
Piece-work
30 days
Delhi Cantt
PLEASE REFER NOTICE INVITING QUOTATION
1 document required · 1 mandatory
₹0
Exempted
27 Apr 2024
28 Mar 2024
8 Apr 2024
30 Mar 2024
6 Apr 2024
30 Mar 2024
Amount
Material & labour for AC Sub main wiring ISI marked with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (Conforming to IS-694) multi stranded, unsheathed 1100 volts grade in PVC casing Capping (medium grade) of adequate size on surface of wall/ceiling with all fittings & casing capping accessories including one run 6 Sqmm single core unsheathed multi stranded, copper cable FRLS (Conforming to IS-694) as earth continuity wire complete all as specified and directed.. {Note:- (i) Three runs of cable with one run of earth wire shall be measured as one unit length. (ii) Earth wire shall run inside the PVC casing caping (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth. (v) (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of PVC casing caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)}- 150 RM. S&F single pole and neutral steel metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of 32 Amps complete Make - Havells/ Standard/Indokupp. - 11 Each. Supply & fixing heavy duty copper pipe of size 1/2" dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size complete all as specified and directed by Engr-in-Charge. (Make:- DIAMOND/ STAR/ MALASIA/ CAMPIRO). - 95 RM. Supply & fixing heavy duty copper pipe of size 1/4" dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size complete all as specified and directed by Engr-in-Charge. (Make:- DIAMOND/ STAR/ MALASIA/ CAMPIRO) - 60 RM. Supply & fixing heavy duty copper pipe of size 15mm (5/8") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size complete all as specified and directed by Engr-in-Charge. (Make:- DIAMOND/ STAR/ MALASIA/ CAMPIRO). - 152 RM. S&F PVC drain pipes of suitable size 25 mm complete all as specified and directed by Engr-in-Charge. - 160 RM.Dismantling and Refixing the Split Ac of 1.5/2.0 TR including Drilling of Holes into a brick wall for connecting indoor with Outdoor Unit's pipe and connecting indoor and outdoor units with copper pipes and installation of drainage pipes and fixing Outdoor unitonseparatelyODUstand, Temperature&GaspressureTesting,GasCharging, Carpentry work,Plumbing,Masonry&Whitecementing Note :- Drain Pipe, Copper of required size, Refrigerant gas, Outdoor stand, Power plug, MCB and Copper wire to be paid under relevant item. S&F new Outdoor Unit (ODU) Stand for 1.5 TR/2.0 TR type Split AC as directed and specified by Engineer in Charge - 11 Each. Taking down unserviceable insulating for copper pipe of sizes suitable for Split AC of Cap 1.5/2.0 TR all as specified and directed by Engineer-in-Charge- 120 Each. Taking down unserviceable PVC drain pipe of size 25 mm dai suitable for Split AC of Cap 1.5/2.0 TR all as specified and directed by Engineer-in-Charge.- 90 Each. Supply and filling refrigerant Gas R-22/R-32/R-410A/R-134 in Split type Ac unit of Capacity 1.5.2.0 TR including detecting theleakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting & brazing of copper tubes testing and commissioning complete in satisfactory working condition all as specified and directed by Engineer-in-Charge, Make-Mefron/Floron/Refron - 11 Each Job welding or by any other means including cutting & brazing of copper tubes testing and commissioning complete in satisfactory working condition all as specified and directed by Engineer-in-Charge, Make-Mefron/Floron/Refron - 11 Each Job
BUSINESS TEK INDIA
Nakul Enterprises
Tushar engineers
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_725773.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .