QUANTUM OF WORKS FOR 33 KV LINE, 11 KV AND L.T. LINE DUE TO ROAD WIDENING OF MEERUT TO PRAYAHRAJ ROAD (GANGA EXPRESSWAY), UNNAO UNDER DEPOSITE SCHEME UNDER THE AREA OF EDD-V, HASANGANJ, UNNAO
2021_MVVNL_664955_2
144/E.D.C./Unnao/2021-22
Open Tender
Miscellaneous Works
Fixed-rate
180 days
UNNAO
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/C-No.3355002101008374,IFSC-Code-PUNB0335500,
₹14,000
18 Jan 2022
30 Dec 2021
11 Jan 2022
30 Dec 2021
10 Jan 2022
30 Dec 2021
Amount
Safe Carriage of following Materials from Electricity store center Unnao to diff. work dump site with loading, unloading and proper stocking.
PCC/S.T. Pole 11 mtr Long
25 KVA Transformer
ACSR Weasel Conductor
33 KV XLPE Cable size 3x300 sq mm
11 KV XLPE Cable 3x185 sq mm
ABC Cable (3X150+1X35+1X16) mm2
ABC Cable (1X16+1X25)mm2
Other loose Materials of above work including Single and Double Pole accessories, stay rod, earthing rod, insulator, x-arm, Stone pad, channels & angle etc.
33 KV Crossing
Erection of Double Pole for 33 KV Line on 11 mtr long S.T. Pole including digging of pits, fitting of accessories along with cartage & dragging from dump site to pits site.
Painting of S.T. Pole with one coat of Red Oxide and two coat of Alluminium Paints I.S.I. mark (All Material provide by contractor)
Earthing of ST poles as per RESPO norms
Grouting of Poles as per RESPO norms with grouting material.
Digging of pits, fixing & nozzeling of stay wire and grouting of stay rod RESPO norms with grouting material.
Double Circuit Cable laying in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40 m, the two cables should be seprated by a partition of single bricks (All the material required for laying will be supplied by the contractor except 33 KV XLPE Cable)
Cable Laying by drill method in HDPE Pipe 150 mm 8'' dia (all material arrange by contractor only cable provided by departmental).
Cable Hosting in G.I. Pipe of 6'' dia. (Two No. Job each D/Pole)
Supply and Fixing of 33 KV O/D and I/D jointing kit
Supply and Fixing of 33 KV S/th jointing kit
Fixing of Danger Board with clamp (All Material provide by contractor)
11 KV Crossing
Erection of Single Pole for 11 KV Line on 11 mtr long S.T. Pole including digging of pits, fitting of accessories along with cartage & dragging from dump site to pits site.
Earthing of ST poles as per RESPO norms
Digging of pits, fixing & nozzeling of stay wire and grouting of stay rod RESPO norms with grouting material.
Grouting of Poles as per RESPO norms with grouting material.
Making of T-off arragement including fabrication & fitting of accessories.
Laying of 11 KV 3-Ph Line stringing and sagging of ACSR Weasel conductor including all associated works and making clearance of road with joints/jumpers and binding of insulator as required.
Fixing of 11 KV Danger Board with clamp
Double Circuit Cable laying in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40 m, the two cables should be seprated by a partition of single bricks (All the material required for laying will be supplied by the contractor except 11 KV XLPE Cable)
Cable Laying by drill method in HDPE Pipe 150 mm 6'' dia (all material arrange by contractor only cable provided by departmental).
Cable Hosting in G.I. Pipe of 6'' dia. (Two No. Job each D/Pole)
Supply and Fixing of 11 KV O/D and I/D jointing kit
Supply and Fixing of 11 KV S/th jointing kit
Shifting of L.T. Line
Placement of 25 KVA S/S On PCC Pole
Placing of 25 K.V.A. healthy Transformer from out side of yard to plinth with the help of crain and T & P.
Erection of Double Pole for new 25 KVA T/F on 11 mtr long PCC Pole including digging of pits, fitting of accessories along with cartage & dragging from dump site to pits site.
Laying of .Laying of ABC (3x50+1x35+1x16) stringing and sagging of ACSR Weasel conductor including all associated works and making clearance of road with joints/jumpers and binding of insulator as required
Fixing of 11 KV Danger Board with clamp ( all material Provided by contractor)
Digging of pits, fixing & nozzeling of stay wire and grouting of stay rod RESPO norms with grouting material.
Laying of ABC Cable
Erection of Single Pole for L.T. Line on 11 mtr long PCC Pole including digging of pits, fitting of accessories along with cartage & dragging from dump site to pits site.
Laying of ABC (1x16+1x25)mm2 stringing and sagging of ACSR Weasel conductor including all associated works and making clearance of road with joints/jumpers and binding of insulator as required
Digging of pits, fixing & nozzeling of stay wire and grouting of stay rod RESPO norms with grouting material.
Fixing of Danger Board with clamp
Fixing of single phase L.T. Distribution Box ( Providing by Departmental)
A. A. ENGINEERING CO.
M R P CONSTRUCTION
Ludhiana Agencies (regd.)
S S Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .