Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹27.4 LAccepted-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L 1 | Accepted-AOC Accepted being L1 | |
| 2 | L 2₹28.0 L+₹64,578.40 (2.36%)Rejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L 2 | Rejected-AOC Rejected being not L1 | |
| 3 | L 3₹31.6 L+₹4.2 L (15.3%)Rejected-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | L 3 | Rejected-AOC Rejected being not L1 | |
| 4 | L 4₹31.9 L+₹4.5 L (16.4%)Rejected-AOC 127 GYAN LOK DEFENCE COLONY ROORKEE DISTT HARIDWAR UK PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | L 4 | Rejected-AOC Rejected being not L1 | |
| 5 | L 5₹32.5 L+₹5.1 L (18.5%)Rejected-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L 5 | Rejected-AOC Rejected being not L1 |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
23 Dec 2021, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Military Engineer Services Roorkee PIN-247667
SPL REP TO WIRING WITH FITTINGS AND FIXTURES IN OTM BLDG NO. E 252 OF TEO OFFICE AT BEG AND C BLDG NOS T 733, T 734 AND T 735 ORS LIVING ACCN OTM ACCN OF 29 PUNJAB AT ROORKEE SPL REP REPLACEMENT OF GI PIPE LINE PLUMBING EQUIPMENTS CHLORONOME DOZER AN
2021_MES_492032_1
8391/081/E8
Open Tender
Civil Works
Item Rate
180 days
Roorkee
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Roorkee
₹79,000
Yes
19 Feb 2022
2 Dec 2021
25 Dec 2021
2 Dec 2021
23 Dec 2021
10 Dec 2021
Amount
Taking down existing point wiring of any description including all fittings and fixtures and M&L for new concealed type point wiring with 1.5 Sqmm (Nominal area) PVC insulated, unsheathed FRLS multi stranded copper conductor single core cable drawn through and including PVC non metallic conduit of 20 mm dia (ISI marked) with all accessories including sunken type terminal/junction box made of 1.6 mm thick GI sheet with 3 mm thick bakelite sheet top cover (ISI marked) and PVC insulated and unsheathed single core FRLS multi-stranded copper conductor green colour cable of size 1.5 Sqmm (Nominal area) as earth continuity conductor connected to common earth and earth dolly including cutting chases for concealed point wiring and making good in cement mortar (1:3) including two coats of white wash/distempering over a coat of primer to match the existing surfaces complete all as specified and directed for the following :-
One light point controlled by one one way switch complete all as specified and directed.
One fan/ exhaust fan point controlled by one one way switch complete all as specified and directed.
One 3/5 pin socket outlet 5 Amp on the same board with other swithes complete all as specified and directed.
One 3/5 pin 5 Amps socket outlet on independent board complete all as specified and directed.
All as per Srl item No. 1.00 here in before but new point wiring with 2.5 Sqmm (Nominal area) FRLS cable for 15 Amps 3/5 pin socket power point including 2.5 Sqmm copper conductor green colour FRLS cable for earth continuity complete all as specified and directed.
S&F 5 Amps switch piano flush type polycarbonate single pole one way complete all as specified and directed.
S&F 15 Amps switch piano flush type polycarbonate single pole one way complete all as specified and directed.
S&F 2 in 1, 3 pin 5 Amps socket outlet polycarbonate flush type complete all as specified and directed.
S&F 2 in 1, 3 pin 5/15 Amps socket outlet polycarbonate flush type complete all as specified and directed.
S&F electronic fan regulator 230 volts , step type (5 step) socket type ,hum free 100/300 watt complete all as specified and directed. Make: Anchor(Penta)/Havells(REO)/ Legrand
S&F in replacement, ceiling rose in polycarbonate 3 terminal brass flush type 6 Amps, 250 Volts AC (ISI marked), fixing on & including 3 mm thick & 75mm dia sunmica hylum plastic laminated round sheet 75mm dia complete all as specified and directed. Make: Havells (ROHS) Cat Part No . AHLHXCW000 or Anchor PC Cat Part No- 3907250916 / SSK cat part No B07QS98JCQ
S&F in replacement, batten holders (metal ring) PVC / polycarbonate type with back plate, fixing on and including 3 mm thick & 75mm dia sunmica hylum plastic laminated round sheet complete suitable for LED bulb all as specified and directed. Make: Havells (ROHS) Cat Part No AHLHXAW000 or Anchor PC cat part No- 3980051170 / SSK Cat Part No. 76
S&F in replacement, LED bulb 12 watts with B-22 base operated on single phase AC supply complete all as specified and directed.
Taking down old unserviceable light fittings of any description and S&F new LED tube light fittings 20 Watt industrial batten box type with bipin holders connector block complete with all accessories internally prewired and connecting up with & including three core flexible single wire including 01No. 20 Watt retrofit LED tube rod T8 polycarbonate, fixed at any height on wall/ceiling complete all as specified and directed. Make : Havells (Rod) Cat No-PHOTONULTRAE 2.01213T8 SSTL20WLED865SPC Havells (Batten) Cat No- REGALBATTENT 8UPTO1X22WSSBSWH or Bajaj (Batten) Cat No- 112181 BLRB-DB 118, Bajaj (Rod) Cat No - 112481 BLRB 21W CWC or C&S LTDC0161820WLED + LT4F20WLEDT8WD.
Taking down old unserviceable building security light fitting of any description and S&F new building security light fitting versatile pressure die-cast aluminium with high power LED 25 Watt as light source complete with LED 25 W 5000K including brackets made out of 40mm dia GI pipe light grade, bent to shape required and fixed with 02 Nos MS flat iron clamps including nut & bolts and connecting up with & including flexible wire of suitable size complete all as spd and directed. Make : C&S Cat Part No. LTESSI25WLED or Bajaj Cat Part No. 169821 BCLST 25W LED I or Wipro Cat Part No. D923065.
Taking down old unserviceable ceiling light fittings of any description and S&F new recesss mounting light fitting 2'x 2' of capacity 36 Watts powder coated white CRCA full glow suitable for 600 x600 mm POP false ceiling including making electrical connection from ceiling rose to light fitting with & including flexible wire of suitable size and tube rod complete all as specified and directed. Make: C&S Cat No. LTCRP36WLED2X2 or Havells Cat No. STRATO2X2PLR36WLED857MOD or Bajaj Cat No. 111778 BZRSQL 36W GZ WH.
Taking down old unserviceable tube light fittings of any description and S&F new LED tube light fitting 2x20 Watt (4 feet) industrial batten box type with bipin holders connector block complete with all accessories internally prewired including making fixing arrangement, suspended to ceiling with 2' long metal chain 02 Nos, connecting up three core flexible single wire including 2x20 Watt retrofit LED tube rod T8 polycarbonate, fixed at any height of wall/ceiling complete all as specified and directed. Make:- Crompton Cat Part No / Product Code No. IGP162LT8-16 or equivalent in Havells Cat No. REGALBATTENT8UPTO2X22 WDSBSWH or Bajaj Cat No. 112236 BPTXn 2-20W LED 8F WH .
Taking down old sub main wiring of any description and S&F new sub main wiring with two runs of single core (FRLS) PVC insulated and unsheathed multistranded, copper conductor cable of size 4.0 Sqmm LT, 1100Volt grade, drawn through and including PVC non metallic conduit of 20mm dia or other appropriate dia with all accessories and fittings and one run of 4.0 Sqmm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall be deemed to be included in quoted rates and shall not be measured separately complete all as specified and directed. Note :- (i) Two runs of submain cable & one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs shall be deemed to be included in unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit pipe. (iv) Extra length of cable required for connection to MCBs shall be deemed to be included in unit rate.
All as per Serial item No. 15.00 above but submain wiring with two runs 6.00 Sqmm copper conductor and one run of 6.00 Sqmm as earth continuity conductor complete all as specified and directed.
Taking down old unserviceable distribution board of any description and S&F new distribution board (double door) VTPN 4 way made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, IP 43 with 250 Amps rated copper bus bar, neutral bar, earth bar, triple pole and neutral, with provision for 160 Amps MCCB as incomer and MCBs TP/DP/SP as outgoing, flush to wall complete all as specified and directed. Make- Legrand Cat No. 5077 45 or C&S Cat No. CSDBMCCB100DD04IP43S or IndoAsian Cat No. 811888
S&F in replacement, MCCB 100 Amps four pole, 415 Volt, 25kA adjustable thermal and magnetic setting including necessary connection complete all as specified and directed by Engnieer-in-Charge. Make: Legrand Cat Part No.4200 55 or IndoAsian Cat No. 830272 or C&S Cat No. CSEMX125FMU4P-A
Taking down old unserviceable distribution board of any description and S&F new distribution board (double door) SPN 8 way made out of sheet metal enclosure (CRCA sheet) dust and vermin proof IP 43 with 100 Amps rated copper bus bar, neutral bar, earth bar, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : L&T Hagar Cat No. Y81082 or IndoAsian Cat No. 811807 or Legrand Cat No. 507611
S&F in replacement, MCBs double pole, 40 Amps 240 Volt 'C' curve with breakin capacity 10 KA complete all as specified and directed. Make - L&T Hagar or IndoAsian Cat No. 811174 or Legrand Cat Part No. 408637.
S&F in replacement, MCBs single pole (SP), 10-32 Amps 240 volt 'C' curve with breakin capacity 10 KA complete all as specified and directed.
S&F in replacement, single pole and neutral sheet metal enclosure with two pin and earth plug and socket including MCB Single Pole 20 Amps, 240 Volt and fixed flush in wall suitable for geyser / AC connection complete all as specified and directed. Make : Legrand Cat Part No. 5078 11 20A SP 2P+E or IndoAsian Cat No. 810386 or L&T Hagar Cat No. Y84120
Taking down old unserviceable ceiling fan of any sweep and depositing to AGE E/M store and S&F new energy efficient ceiling fans three star rated 230 Volt, 1200mm sweep with blades, minimum air delivery 225 CMM including down rod of suitable size and all connected accessories, connecting with three core round lead 0.5 Sqmm complete all as specified and directed. Make : Bajaj SPEEDSTER model or Havells Samrat / Aeroking model
Dismatling / taking down old unserviceable earthing of any description and M&L for new earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete including PCC masonry pit of 300x300x300mm inner size in PCC (1:2:4) type B1, RCC cover with angle iron frame of size 40x40x6mm using 8mm dia TMT bars @ 10cm c/c in both ways, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe all as per electric plate No. 3 of SSR 2009 (Part-I) including testing after completion complete all as specified and directed. Note: Note: (i) The unit rate includes earth strip and protection pipe up to (maximum 7.5 meter from earth plate) earth point/test point. (ii) The desired earth resistance shall be less than 1 ohm. if the same is not achieved, the contractor shall re-do the earthing without any extra cost to the Govt.
Supply, laying in replacement and testing, electric power cable of size 25 Sqmm 3.50 core XLPE insulated (heavy duty), 1100 Volts grade with stranded aluminium conductor, screened, PVC bedded, galvanized steel strip or wire armoured complete all as specified and directed
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5 M in depth for laying cables, pipes etc and getting out in any type of soil complete all as specified and directed.
Returning filling in trenches with excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick after laying & testing of cables/pipes etc complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed
Supply and laying fine dry sand in cushioning to under ground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and as directed by Engineer-in-Charge. Note:- Punning thickness of sand cushioning shall be measured as 18 cm.
Supply and laying old size kiln burnt sub class ‘B’ bricks, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed by Engineer-in-Charge.
Supply and laying in replacement, 40mm da bore GI tubing medium grade with all fittings for cable protection, fixed with & including GI clamps, nut & bolts and washers or burried in ground etc complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable light fittings of any description and S&F new LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 Volt, AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable distribution board of any description and S&F distribution board (double door) SPN 4 way, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, IP 43 with 100 Amps rated copper bus bar, neutral bar, earth bar including lugs ring type and pin type, flush to wall complete all as specified and directed. Make - Legrand Cat No. 5076 10 or IndoAsian Cat No. 811805 or L&T Hager Cat No. Y81042
S&F MS fan hook using good quality fastener & clamp including suitable length fan extension rod, nut-bolts, screw, washers etc, with provision of fixing in the ceiling by drilling hole of 12-14mm dia in RCC ceiling and fixing the hook inside the hole tightly, complete as required at site including making good the disturbed sufaces in PCC (1:2:4) type B0, plastering in cement mortar (1:3) and two coats of white wash or distemaper over a coat of primer to match the existing surfaces complete all as directed by Engineer-in-Charge .
Taking down existing exhaust fan of 450mm sweep carefully, fixed at any height and refixing the same including servicing, overhauling, painting and replacement of capacitor 4.0 MFD, ball bearing, rubber bushes and fan blade and connecting with new wire of suitable size as per site requirement, complete all as specified and directed by Engineer-in-Charge. Note: Rewinding of motor, if required, shall be measured and paid for separately at M&L rates.
M&L for rewinding of 450mm exhaust fan with super enamelled copper wire of size including servicing and minor repairs complete all as specified and directed by Engineer-in-Charge .
Taking up or down galvanised steel tubing and connections of any size and type complete all as directed for the following sizes :-
15 mm dia bore
20 mm dia bore
25 mm dia bore
50 mm dia bore
80 mm dia bore
S&F galvanised steel water tubing medium grade including all fittings such as bends, elbows, tees, reducers, sockets, union etc and laid in floor or fixed to wall and ceiling complete all as specified and drected of the following bore.
15 mm dia bore
20 mm dia bore
25 mm dia bore
50 mm dia bore
80 mm dia bore
Refixing old GI pipes after cleaning with all fittings in old or new location as per site requirement to wall/ceiling or laid in floor/trenches complete al as specified and directed for the following sizes:-
15 mm dia bore
20 mm dia bore
25 mm dia bore
50 mm dia bore
M&L for cutting and screwing existing steel tubing or alterations or additions complete all as specified and directed for the following sizes:
15 mm dia bore
20 mm dia bore
25 mm dia bore
40 mm or 50 mm dia bore
M&L for drilling and tapping cast iron water mains (in position) for branch connections of 20mm internal dia complete all as specified and directed.
S&F 20mm dia bore straight plain brass ferrule (or connecting screws), screwed both ends and fixed to water mains for tapping branch connection complete al as specified and directed.
S&F in repairs, 20mm dia bore gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete al as specified and directed.
S&F in repairs, 25mm dia bore gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete al as specified and directed.
S&F in repairs, 50mm dia bore gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete al as specified and directed.
S&F in repairs, 80mm dia bore sluice valve PN 1.6 (ISI marked), screwed both ends for iron pipe complete al as specified and directed.
S&F in repairs, 15mm dia bore PTMT bib tap, standard, of any colour, high pressure, screwed for iron pipe complete al as specified and directed.
Demolition of old plain cement concrete of any description and in any position and M&L for plain cement concrete (1:3:6) type C1 (using 20 mm graded stone agregate) as in damaged plinth protection and the like, finished even and fair complete all as specified and directed by Engirneer-in-Charge
Demolition of old plain cement concrete of any description and in any position and M&L for plain cement concrete (1:2:4) type B1 (using 20 mm graded stone agregate) as in damaged portions of cills, copings and the like, finished even and fair complete all as specified and directed by Engirneer-in-Charge.
Taking down old unserviceable dosing pump etc and Supply, installation, testing & commissioning of new Granular chlorination Dosing pump (Model 96 NGQ 51), high pressure, single head, gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U.S. GPD and adjustable high pressure of up to 100 PS I (7Kg/Sqcm) with accessories including lead, tubing, connection nuts, injection check valve, clay weight and ferrules also including 100 liters FRP tank with lid & Level gauge along with agitator and shaft & blade in plastic mounted on tank.The agitator motor shall have capacity of voltage input 230Volt, single phage, 50Hz, 900 rmp 100 watt complete all as specified and directed by Engineer-in-Charge. Make- DECLIBAC Technologies or equivalent as approved by GE.
M&L for construction of valve chamber of internal size 900 mm x600 mm x 1000 mm with the following specifications:- (a) Excavation in any type of soil for trench of size 1560mmx1260mmx1100mm, returning filling and removal of surplus soil at a distance n.exc 50m where directed. (b) 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) in foundation trench of size 1560mmx1260mm. (c) Brick work in cement mortar (1:6) in one brick thick walls using old size sub class 'B' bricks keeping internal size of chamber 900mmx600mm. (d) 75mm thick PCC (1:3:6) type C1 (using 20mm graded stone aggregate) in coping on top of brick walls including fixing of chamber cover and finished even and fair as specified. (e) 40mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in flooring in bottom of chamber, finished even and fair as specified. (f) 10 mm thick plastering in cement mortar (1:4) on all exposed surfaces of walls including sides of PCC coping, finished even and fair as specified. (g) MS cover made of 5.0 mm thick MS plain black sheet welded to angle iron 40mm x40mm x6mm frame with holdfasts of same size of angle iron, MS handle made of 10mm dia MS round bar including locking arrangement, two coats of synthetic enamel paint over coat of red oxide primer on steel surfaces and two coats of white wash on the plastered / concrete surfaces. complete all as specified and directed. Note: The quoted rate is deemed to be inclusive of demolition of existing valve chamber and removing from site after recovery of credit as per Schedule of credit for old useable materials and unserviceable materials to be removed outside the MD land.
All as per Srl item No. 51.00 above but internal size of valve chamber 450mm x 450mm x 600mm with 230mm thick brick walls.
S&F in replacement, 25mm dia bore brass ball valve, high pressure with polythene float and fly nut, screwed for iron pipe complete all as specified and directed.
S&F in replacement, 20mm dia bore brass ball valve, high pressure with polythene float and fly nut, screwed for iron pipe complete all as specified and directed.
S&F double door distribution board TPN 4 way made out of sheet metal enclosure (CRCA sheet) dust and vermin proof IP 43 with 200 Amps rated copper bus bar, neutral bar, earth bar, triple pole and neutral 415 Volts, flush to wall complete all as specified and directed. Make- Legrand Cat No. 5077 45 or C&S Cat No. CSDBMCCB100DD04IP43S or IndoAsian Cat No. 811888
S&F single pole and neutral sheet metal enclosure with two pin and earth plug and socket also including MCB double pole 20 Amps, 240 Volt and fixed flush in wall suitable for AC complete all as specified and directed. Make : Legrand Cat Part No. 5078 11 20A SP 2P+E or IndoAsian Cat Part No. 810386 or L&T Hagar Cat Part No - Y84120
Supply, laying and testing of 25 Sqmm 3.5 core XLPE Insulated screened PVC bedded galvanized steel strip and wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded alluminium conductor complete all as specified and directed.
M&L for submain wiring, concealed with two runs of single core FRLS PVC insulated and unsheathed multi-stranded, copper conductor cable of size 4.0 sqmm LT, 1100V grade, drawn through and including PVC non metallic conduit of 20 mm / suitable dia with all accessories and fittings and one run of 4.0 Sqmm single core FRLS multi stranded copper conductor cable as earth continuity conductor including cutting chases and making good in cement mortar (1:3) to match the existing surfaces including necessary surface finishes with two coats of white wash or distempering of any type over a coat of primer to match the existing finishes complete all as specified and directed. Note:- (i) Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs shall be deemed to be included and shall not be measured separately.
Supply, installation, testing and commissioning of 1.5 Ton capacity split type air cooled Air Conditioner, electric driven (Single phase), BEE 3 star rating, including fixing outdoor unit in wall with necessary clamps, nuts & bolts and washers complete all as specified and directed by Engineer-in-Charge. Make : Voltas Series- Delux, Model No. SAC 183 DZQ / R32 or equivalent in LG, Samsung, Hitachi as approved by GE.
Supply, installation, testing and commissioning of 2.0 Ton capacity split type air cooled Air Conditioner, electric driven (Single phase), BEE 3 star rating, including fixing outdoor unit in wall with necessary clamps, nuts & bolts and washers complete all as specified and directed by Engineer-in-Charge. Make : Voltas Series- Classic, Model No. Voltas SAC 243 CZZ/CZZO (R32) or equivalent in LG, Samsung, Hitachi as approved by GE.
Note for Srl item Nos 59 & 60: - (i) The tenderer shall confirm the availability of AC from market before quoting the rates. (ii) The quoted rate shall be deemed to be included the cost of cutting / drilling holes in brick wall as required for installation of AC including covering with ply as required at site and making good the disturbed surfaces to match with adjoining surfaces complete. (iii) Existing unserviceable / serviceable AC of any description and capcity shall be removed from site and deposited in MES store. Transportation charges etc shall be borne by the contractor.
S&F 4 KVA capacity voltage stablizer for automatic opeartion, single phase, naturally air cooled indoor type & designed for input variation between 130 Volt to 300 Volt with voltage stabilized at 230 Volt with accuracy of (+) 2.5% complete all as specified and directed by Engineer-in-Charge. Make: Microtek, Model No. SMART EM 4130+ or equivalent in V-guard/Voltas/Luminus as approved by GE.
S&F 5 KVA capacity voltage stablizer for automatic opeartion, single phase, naturally air cooled indoor type & designed for input variation between 130 Volt to 300 Volt with voltage stabilized at 230 Volt with accuracy of (+) 2.5% complete all as specified and directed by Engineer-in-Charge. Make : Microtek, Model No. PEARL EM 5130+ or equivalent in Luminous/ Voltas/ V-Guard as approved by GE.
S&F 1.00 KVA Voltage stabilizer for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 Volt with accuracy of ±2.5% complete all as specified and directed by Engineer-in-Charge.
S&F 40mm dia bore GI tubing, medium grade, with all fittings for cable protection, fixed to wall including GI clamps, nut & bolts and washer or laid in floor / ground etc complete all as specified and directed by Engineer-in-Charge.
S&F 20mm dia bore GI tubing, medium grade, with all fittings for cable protection, fixed to wall including GI clamps, nut & bolts and washer or laid in floor / ground etc complete all as specified and directed by Engineer-in-Charge.
M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in ground vertically in pit of depth not less than 2.25 meter below normal ground level with top edge of the earth plate at a depth not less than 1.5 meter below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) (chamber size not less than 300x300x300mm interior dimensions), type C-1 for chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame of angle iron 40x40x6mm etc complete all as specified. Note: (i) The unit rate includes earth strip and protection pipe up to (maximum 7.5 meter from earth plate) earth point/test point. (ii) The desired earth resistance shall be less than 1 ohm. if the same is not achieved, the contractor shall re-do the earthing without any extra cost to the Govt.
S&F MCB TPN/FP 40 to 100 Amps capacity, 415Volt, 'B' curve, breaking capacity 10 KA, fixed in distribution board including necessary connections, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for water cooler with 2.5 Sqmm (Nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor single core cable drawn through and including PVC non metallic conduit of 20mm dia (ISI marked) with complete accessories including sunk type mild steel terminal box made of 1.6mm thick GI sheet with 3mm thick bakelite sheet top cover (ISI marked) including 2.5 Sqmm (Nominal area) PVC insulated and unsheathed single core multistranded copper conductor cable green in colour as earth continuity conductor connected to common earth and earth dolly, dolly including cutting chases for concealed point wiring and making good in cement mortar (1:3) including two coats of white wash/ distempering over a coat of primer to match the existing surfaces complete all as specified.
Supply, installation, testing and commisioning water cooler of cooling capacity 40 Ltrs per hour and storage capacity 80 Ltrs, stainless steel body as per manufacturer's standards, electric driven, single phase with minimum two years guarantee/ warranty for machine & compressor complete all as specified and directed by Engineer-in-Charge. Make: USHA (SS4080)XTRA LARGE or Voltas Model No: 40/80 NCW FSS or Bluestar Model No. PC 4080B
S&F 15mm dia bore gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
M/s badrinath Traders
AJAY KUMAR CONTRACTOR
Bhardwaj Construction Co
VIJAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .