Tender Value
₹30.4 L
EMD Value
₹60,900
Closing Date
18 May 2026, 5:00 pmClosed
MD RISL
MD RISL Yojana Bhawan Jaiipur
Request for Proposal for SITC OF NEW VRV Air Conditioning Systems and Dismantling the Existing System at Yojna Bhawan Jaipur, Rajasthan
2026_RISL_556017_1
F3.3(571)/RISL/PUR/2026/ML-215 dated 04-05-2026
Open Tender
Miscellaneous Goods
Item Rate
60 days
Jaipur
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Yes
Managing Director, RISL
₹60,900
Yes
11 Jun 2026
6 May 2026
19 May 2026
6 May 2026
18 May 2026
6 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling & heating, having 100% hermetically sealed inverter type twin rotary/Scroll Compressor(s) with and minimum two compressors , above 14 HP modules, microprocessor based Controller, Side / top discharge type condensing unit(s), with R-410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The EER/COP (W/W) at 100% load with AHRI conditions shall not be less than 3.8 etc. complete as required. | |||||
| 1.01 | 14 HP to 26 HP | 80 | Per HP | - | - |
| 2Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down valve in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor). | |||||
| 2.01 | 2.4 TR (Cooling Capacity 8700 Watt) | 2 | Each | - | - |
| 2.02 | 4.0 TR (Cooling Capacity 14000 Watt) | 5 | Each | - | - |
| 3Supply, installation, testing and commissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 with 7 mil Glass Cloth and 3 coats of anti UV paint (on area which is exposed to weather) including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. | |||||
| 3.01 | 28.6 mm O.D., wall thinkness ≥ 1.2mm (insulation – 19 mm thick) | 30 | Mtr. | - | - |
| 3.02 | 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | 30 | Mtr. | - | - |
| 3.03 | 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | 30 | Mtr. | - | - |
| 3.04 | 9.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | 30 | Mtr. | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
cancelled_1.pdf
pdf • 0.22 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
RFP.pdf
Tender Documents • 1.56 MB
BOQ_990238.xls
BOQ • 0.40 MB
Corrigendum-2.pdf
PDF • 0.69 MB
Corrigendum_1_Date.pdf
PDF • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .