Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Quoted lowest rate | |
| 2 | L2₹14.3 L+₹1.2 L (8.89%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹15.4 L+₹2.3 L (17.2%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest bidder | |
| 4 | L4₹15.8 L+₹2.7 L (20.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹16.7 L+₹3.6 L (27.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹18.9 L
EMD Value
₹48,000
Closing Date
22 Feb 2020, 6:00 pmClosed
Garrison Engineer
Garrison Engineer (North) Bathinda Mil Stn
SPECIAL REPAIR TO BUILDING, PROVN OF SHED, HARD STANDING, INTERLOCKING TILES AND CERTAIN OTHER REV WORKS UNDER AGE BR-V OFFICE OF GE NORTH BATHINDA AT BATHINDA MIL STN
2020_MES_318623_1
8934/NIT-59/19-20
Open Tender
Civil Works
Item Rate
184 days
GE North bathinda
Class E
9 documents required · 9 mandatory
₹500
GE (N) Bathinda Mil Stn
₹48,000
Yes
2 Mar 2020
27 Jan 2020
25 Feb 2020
27 Jan 2020
22 Feb 2020
17 Feb 2020
28 Jan 2020 - 3 Feb 2020
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil including cutting of grass, roots, bushes if any and filling of lower portion with soil obtained from cutting and dressing complete all as specified and as directed by Engineer-in-charge.
Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Material and labour for hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Material and labour for hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in foundation filling, bed block, for embedded fencing posts, coping/packing around chequered tiles/interlocking tiles/PCC jalli & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base of floor, under paving, plinth protection, under interlocking tiles etc over rammed earth/hard core complete all as specified and as directed by Engineer-in-charge.
Material and labour for 100mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base of floor, under paving, plinth protection, under interlocking tiles etc over rammed earth/hard core complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in foundation filling and mass concrete, bed block, for embedded posts & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for 100mm thick cement concrete ( 1:2:4), type B-1 using 20 mm graded stone aggregate as in floor, hardstanding/paving/path etc, in panels size as directed with provision of expansion joints and including mixing fibre 12mm recron 3s @ 900gms/cum of cement concrete, surface finished even & smooth without using extra cement including necessary form work complete all as specified and as directed by Engineer-in-charge. NOTE : (i) Filling of expansion joints shall be measured and paid separately under appropriate item of BOQ. (ii) Recron 3s shall be measured & paid separately as Supply only
Material and labour for forming 12mm thick expansion joints (thickness of concrete slab 100mm ) filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound Grade 'B' including cutting extra concrete as required complete all as specified and as directed by Engineer-in-Charge.
Material and labour for PCC (1:2:4) B-1 using 20 mm graded crushed stone aggregates as in Precast cement concrete hollow block masonry (kerb stone) exceeding 10 cm in width including all necessary form work and earth work, finishing concrete surface fair and even and setting in mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC paver mould / Rubber paver moulds on Vibrating Table Machine) using grey cement and pigment, prepolished & preglazed, shape haxagon / trigular / zigzag / I-shaped etc, as directed, prepolished & preglazed, specification as per relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over sand upto required thick layer and filling the interstices etc complete all as specified and as directed by the Engineer-in-Charge. Note : - (i) Sand for filling shall be measured & paid separately as Supply only but labour for spreding leveling shall be included in the unit rate of this item)
Supply only fine sand without silt (Fazilka/Zera or any other approved sources) for filling under interlocking tiles and the interstices etc and under floor complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size bricks (old serviceable bricks obtained from demolition/dismantled item shall be reused ) straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg and mixing fibre 6mm recron 3s @ 125gms/bag of cement of 50Kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound and recron 3s shall be measured & paid separately as Supply only)
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
Supply only recron 3s type CT 2024, 6mm/12mm complete all as specified and as directed by the Engineer-in-Charge. Make :- Reliance /Swastic /Fosroc or equivalent (Equivalency approved by GE)
Roughening surfaces of old concrete floor by picking and prepare the surface to receive the screed for tiling, sweeping cleaning and washing down with water to remove dust etc. complete all as specified and as directed by Engineer-in-Charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from the site to a distance not exceeding 100 metre and deposited as directed complete all as directed by Engr-in-Charge
Material and labour for Glazed ceramic coloured tiles 7 to 8mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in vertical surface such as skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (rendering) in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (dark shade, jointless) 8 to 10 mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (dark shade, jointless) 8mm to 10mm thick square or rectangular (same as floor tile, as per above item ), as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (dark shade, jointless) 8 to 10 mm thick square or rectangular area of each tile exceeding 0.42 sqm but not exceeding 1sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each and refixing in same opening after necessary easing, adjustments, minor repairs etc all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing factory made 105 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Material and labour for PCC (1:3:6) type C-0, using 12.5 mm graded aggregated as in back filling of chowkhats and for filling in block of hold fast complete all as specified and as directed by Engineer-in-Charge
Supply & fixing factory made plain framed panelled shutters (two or three panels as approved), 35mm thick of 2nd class hard wood (Hollock) with lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces or timber flat on both sides (feather edged). The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply only 125mm long powder coated mild steel butt hinges heavy weight heavy duty cold rolled complete all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel barrel tower bolt stove enamelled black with bright bolt 200 mm long, fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel sliding door bolts 300mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts washers, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel pressed handle of size 150mm, oval type stove enamelled black complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall and making good disturbed surfaces of walls by using CM (1:3) to matching with existing surfaces including cutting and threading of existing pipe any dia for insertaion of tee branch including hole in wall to pass the pipe out side for connection as per site requirment complete all as specified and as directed by Engineer-in- charge.
Supply and fixing bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium snap grid frame work of size of grid 605 x605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium as per above specifications complete all as specified and as directed by Engineer-in-charge.
Dismantling plain or corrugated asbestos cement sheet (corrugated / semi corrugated) including ridges as in roof covering complete all as specified & directed by Engineer-in- charge.
Dismantling wrought iron or mild steel framed work, trusses of any description not otherwise provided for complete all as specified and as directed by engr-in-charge.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, L- type or J -type hooks or cranked bolts and bitumen washer or fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Material and labour for mild steel rolled sections framed work, framed/truss work for fixing GI sheets (design for framing as directed by Engineer-in-charge) and using angle, tee or other section with web and flange cut to shape, drilled and counter sunk for screw, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, conforming to Gde Fe-410-W (Gde E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for mild steel work tubular trusses, poles/post including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to latest relevant IS grade St-240 complete all as specified & directed by Engineer-in- charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth complete all as specified and as directed by Engineer-in-Charge. NOTE : - Complete removal /scraping to old existing treatment as directed by Engineer-in-charge, surface after complete removal and before applying further treatment the surface shall be passed in writing by the Enigineer-in-charge.
Material and labour for preparing the plastered surfaces smooth and to make good depression by applying average 3mm thick layer (1.5mm thick each in two layer application ) of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge) and sanding the surface by using mechanical sander machine (including provision of dust sucking) to make the even and smooth upto entire satisfaction of Engineer-in-charge to receive surface finish of any type of treatment complete all as specified and as directed by Engineer-in-Charge. NOTE : - Surface after after applying putty and before applying further treatment the surface shall be passed in writing by the Enigineer-in-charge.
Material and labour for applying two coats of weather proof exterior emulsion paint (wheather coat Apex, 100% exterier grade) over a coat of exterior emulsion primer by using paint roller brush or electric paint spray machine, as per existing or as approved tint/colour complete all as specified and as directed by Engineer-in-Charge
Material and labour for applying two coats of plastic emulsion paint (finishing smooth and glossy upto entire satisfaction of Engineer-in-charge) over a coat of interior emulsion primer by using paint roller brush or electric paint spray machine, as per existing or as approved tint/colour complete all as specified and as directed by Engineer-in-Charge
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of new steel and iron surfaces of any description, not exceeding 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Supply and fixing/hanging ceiling fan 1200 mm sweep single phase, 230 volts 50 Hz double ball bearing energy efficiant having of BEE 5 star rated including 3 blade, hanging rod, hanging hook, clamp with rubber, including electrical connection with round twin core flexible copper multi stranded cable white in colour of suitable size complete all as specified and directed by Engineer-in-Charge Make - Usha / Bajaj / Khaitan / Orient / Crompton
Material and labour for surface point wiring with 1.5 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC casing caping suitable size as per wiring norms (heavy duty ISI marked), on independent circuit from existing switch board for light /fan/bell point, controlled by one switch, including one run 1.5 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to ceiling fan hook etc. including all fitting arrangement i.e. PVC rawl plug, screw etc. and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 1.5 sqmm copper wire and one run casing caping shall be measured as one RM length for payment. (switches, fan regulator, sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing switch piano flush type (ISI marked), 5/6Amps, single pole, one way fixed in existing laminated sheet including cutting of sheet as required complete all as specified and as directed by Engineer-in-charge.
Supply and fixing stepped type (1-4), electronic Fan regulator (one module), 100 watt, 250 volts, fixed in existing board on laminated sheet complete all as specified by Engineer-in-charge.
Supply and fixing water heater (Geyser) storage type of capacity 25 Ltrs, 5 Star rating, 230V, single phase AC supply, 04 No Nut bolts grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface with plaster and painting as per existing surfaces, including electric, earthing and water connection to geyser and testing complete all as specified and directed by Engineer-in-Charge. Make - Usha / Venus/Bajaj / Kenstar/ Victor/ Polar
Supply & fixing 600 mm long PVC connection 15mm size with Brass CP nuts heavy duty suitable for hot water complete all as specified & directed by Engineer-in-charge.
Supply and fixing angle stop valve cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve shall be as given in SSR or in relevant IS.
Material and labour for surface sub main wiring with 2.5 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC casing caping suitable size as per wiring norms (heavy duty ISI marked), on independent circuit from DB and including one run 2.5 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC rawl plug, screw etc. and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 2.5 sqmm copper wire and one run casing caping shall be measured as one RM length for payment.
Material and labour for concealed sub main wiring with 2.5 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB to geyser and including one run 2.5 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 2.5 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
Supply and fixing (concealed in wall or as directed) factory made sheet metal enclosure made out of CRCA sheet, SPN, 6 Way 240V, single door, earth bar and neutral link, protection class IP-43, dust and vermin proof, suitable for mounting MCB/Isolator and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed in wall or as directed) factory made sheet metal enclosure made out of CRCA sheet, SPN, 4 Way 240V, single door, earth bar and neutral link, protection class IP-43, dust and vermin proof, suitable for mounting MCB/Isolator and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 20 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing HDPE rotational moulded polyethylene cylindrical vertical water storage tanks 200 Ltr cap (triple layered with closed top), conforming to specification of IS:12701-1996 with amendment No 1 and 2 (covered by fig 1) hoisted and fixed in position, including out let and inlet connection complete complete all as specified and as directed by Engineer-in-Charge. Make : Sintex/ Polycon / Rotax / Supereme
Supply and fixing of rubber hose pipe 20 to 25 mm dia between hot water tank & collector fixed with MS clamp complete all as specified and as directed by Engineer-in-Charge. Make : Finolex/Supreme
Supply and fixing Aluminum sheet of 28 SWG fixed over hot water pipe fixing with suitable steel screw full thread complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Glass wool density not less than 42 Kg/Cum and fixed over outer surface of hot water pipe with the help of steel wire cloth of 0.36 mm nominal dia incl binding with GI binding wire complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of Thermostat 0 to 80 deg celcius setting suitable for 25/35/50 Ltr electric water storage geyser and solar water heaters complete all as specified and as directed by Engineer-in-Charge. Make- Elcon/Nenus/power king
Supply and fixing Hot water tank made out of stainless steel 2 mm thick sheet, 200 Ltr cap including covering with glass wool with provision of 15mm dia inlet/outlet arrangement including testing after fixing with solar system as well as electric backup supply system complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Flat plate collector size 1860 mm x 1240mm x 100 mm (ISI marked) or as per site requirement (near about dimensions), assembly suitable for solar hot water system including copper tube black coat, radiation reflector film of aluminum toughed glass, complete all as specified and directed by Engineer-in-Charge. Make :- BHEL/TATA BP Solar/ Inter solar system pvt ltd.
Supply and fixing Heating element 3 KW, 230 volts AC supply (ISI marked ) suitable for solar water heaters (any type) complete with rubber gasket including nut bolts/screw as required complete all as specified and as directed by Engineer-in-Charge. Make: Victor/ Power pack/ sunflame/ Intersolar/Daspass/Suraksha
Supply and fixing 15/20mm bore non return valve of brass (ISI marked), fixing in any position including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 15mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Material and labour for mild steel framed work as in stands for solar water heater system, supports, clamps, grills, framed guard bars, walkways, railing, etc. and similar works fabricated by using MS FI, angle, tee or other structural steel section including nuts, bolts, washers, eye hooks, cut to in any shape or size as indicated or directed, drilled and countersunk for screw, bending and , including welding work with material including two coats of aluminium paint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge
Material and labour for concealed sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor cable continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for surface sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC pipe 20mm dia or casing caping 32mm (heavy duty) on independent circuit and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal box, tee, bend etc. including making good disturbed surfaces of walls/ceiling etc. complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run casing caping shall be measured as one RM length.
Supply and fixing Air termination, single pointed aluminium rod 12mm dia and 300mm long at roof of building/shed at any height, rod fixing/grouted in PCC block of size 200x200x300mm made by PCC (1:2:4) B-1 using 20mm stone aggregate including form work complete all as specified and as directed by Engineer-in-charge.
Supply and fixing earth continuity conductor or main earthing lead fixed to wall with saddles or chases or buried in ground for loop earthing and down conductors (building at any height) etc. or any other indicated situation as required by using 32 x 6mm copper strip including making good to disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Aluminium strip 25 x 3.15mm fixing with suitable size saddles and fixing screws etc. for roof conductors and down conductors (building at any height) above ground including making good to disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity copper strip 32x6 mm (upto test point from earth plate i.e upto 7.5m) by means of GI bolts/nuts/washers and including protected by 40mm dia GI light grade protection pipe from earth plate to test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR Part – I complete all as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Test point shall be measured & paid separately under appropriate item of this BOQ (iii) Earthing result should be less than 3 Ohms and the earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw including junction box made out of GI sheet 3.15mm thick, size of box 150x75x50mm suitable for test point terminal complete all as specified and as directed by Engineer-in-charge. Note:- (i) Copper strip 32x6mm, earth plate to test point shall be included in main item of earthing.
Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, 250 volts, including fixing arrangement as per site condition complete all as specified and as directed by Engineer-in-Charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
B D BATRA AND SONS
M/s HANS BROTHERS
G N CONSTRUCTIONS
M/s Nuway Constructors India Pvt. Ltd.
M/s Balvinder Singh Engineer and Contractors
M/s DHEERAJ JAIN CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .