Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹47.9 L+₹2.5 L (5.54%)Rejected-Finance INDUSTRIAL ESTATE DOLLYGUNJ PORT BLAIR 744 103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹50.0 L+₹4.6 L (10.1%)Rejected-Finance C O M S MITHUN ENTERPRISES MINNIEBAY JUNCTION PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹51.7 L+₹6.3 L (13.8%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹52.5 L+₹7.0 L (15.5%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Jun 2023, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
REPAIRS MAINT OF COMPOUND WALL,MS GATE, FENCING AND CLEANING OF SEPTIC TANK SEWAGE LINES AT ASHWINI NAGAR, JAYANT PARK AND CERTAIN REPAIRS AT OTM ACCN UNDER AGE B/R-I AT GE MINNIE BAY
2023_MES_599755_1
8261/E8
Open Tender
Civil Works
Item Rate
270 days
Minniebay Port Blair
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹90,000
Yes
4 Jul 2023
31 May 2023
22 Jun 2023
31 May 2023
20 Jun 2023
14 Jun 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation and getting out as in soft/loose soil complete all as specified and as directed.
Excavation in trenches exceeding 1.5 m wide and not exceeding 3 m in depth for foundation and getting out as in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed.
Removing excavated surplus soils n.exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed
Demolition of reinforced cement concrete of any description and in any position complete all as specified and as directed
Demolition of precast concrete work/ precast concrete block built in cement mortar including all quoins arches pillars etc complete all as specified and as directed
M& for 75mm thick Plain Cement Concrete (1:3:6) type C2 Nominal mix using 40mm graded aggregate as in plinth protection including finishing even and smooth with using extra cement, including formwork and provision of expansion joints at regular intervals complete all as specified and as directed.
M&L for Plain Cement Concrete (1:3:6) type Nominal mix C2 using 40mm graded aggregate as in surface channels and drain,including formwork complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc including formwork complete all as specified and as directed
M&L for extra for forming finished drain or channel 30 to 50 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/stopped ends etc including formwork complete all as specified and directed.
M & L for setting coat 3 mm thick in CM 1:2 ,trowelled to even and smooth finish complete all as specified and directed.
M&L for 40 mm thick Plain cement concrete type B1 Nominal mix 1:2:4 usnig 20mm graded stone aggregate) in wearing course complete all as specified and as directed
M&L Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and simillar work horizontal or sloping etc complete.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and hooking ends and binding with MS wire (annealed) of dia not less than 0.90mm all as specified and directed.
M & L for Reinforced Cement Concrete 1:2:4 type B1 Nominal mix using 20 mm graded stone aggregate as in slab supported on walls, beams and columns in floors, roofs, landings, deck slab, shelves and like complete all as directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 all as specified and directed by Engineer-in-charge.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) all as specified and directed by Engineer-in-Charge
M&L for removing & cleaning of blockage in WC including WC trap of any description and in any position by removing sand/sludge/silt and other foreign material deposited (either manually or mechanically) upto first manhole and making the sewage system functional complete all as specified and as directed
M&L for removing & cleaning of blockage from traps of bath rooms/ kitchen sink/ wash basin/ Urinal point and gully traps of any description and in any position by removing sand/sludge/silt and other forein material deposited (mechanically) upto first manhole and making the seweage system functional complete all as specified and as directed
Taking out carefully the cover slab of gulley traps of any size and shape, depth and cleaning the blockage by removing the scum/sludge / any material to a distance exc. 250m and n.exc.500m and cleaning with fresh water and placing the cover slab/ Grating in position all as directed
M&L for Cleaning of sewage lines using passing rubber ball through line to ensure all blockage perfectly clear or split bamboo with a gunny bag piece tied with bamboo with binding wire in sewage lines of dia 100 mm and up to 200 mm through manhole/gully trap clear flow of sewage complete all as directed
M&L for pumping out/dewatering of soakage wells, septic tanks etc of any size and depth by machanical means i.e. pumping sets etc and removing the muddy water in liquid or semi liquid/solid state to a distance exc. 250m and n.exc. 500m complete all as specified and as directed
M&L for cleaning manhole of depth n.exc 1 meter depth with spades or bucket by taking out sludge from manhole and disposed off aside by burying the entire sludge under ground in a pit of suitable size and covered with earth and cleaning thw manhole with fresh water to ensure the sludge is drain out completely all as specified and as directed
M&L for cleaning manhole of depth exc 1 meter but n.exc 2 meter depth with spades or bucket by taking out sludge from manhole and disposed off aside by burying the entire sludge under ground in a pit of suitable size and covered with earth and cleaning thw manhole with fresh water to ensure the sludge is drain out completely all as specified and as directed
M&L for cleaning manhole of depth exc 2 meter but n.exc 3 meter depth with spades or bucket by taking out sludge from manhole and disposed off aside by burying the entire sludge under ground in a pit of suitable size and covered with earth and cleaning thw manhole with fresh water to ensure the sludge is drain out completely all as specified and as directed
M&L for making arrangement of scaffolding in the shafts cutting holes around the bends, tees, junctions any description in the leakage/seepage and making good the cut portion with CM 1:3 or PCC 1:2:4 including finishing the portion with two coats of acrylic emulsion paint complete all as directed.
M&L for making arrangement of scaffolding heigh exc 3 mtr and n exc 13 mtr in the shafts / spot/ location of weed growth removing the weed including its root, making good with CM 1:3 or PCC 1:2:4 (12.5mm graded aggregate)including two coats of acrylic paint with primer all as specified
M&L for clearing Vegetation / Shrubs along with all the debris of leaf from roof slab and pouring glyphosate in required proportions and making surface clean, making good with CM 1:3 or PCC 1:2:4 (12.5mm graded aggregate) as per the requirement complete all as specified and as directed.
Taking out old unserviceable PVC (SWR)/CI Pipe of size 75mm & 110mm and 150 mm from trenches and walls with all fitting incl. necessary demolition of haunching, excavation RFR and removal upto 250 mtrs all as specified and directed.
S&F of 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and as directed
S&F of 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F of 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F of 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S& F of 150mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches floor or wall complete all as specified and as directed
M&L for Plain concrete bed (1:3:6) Type C1 to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in 150mm dia pipe.
M&L for Plain concrete bed (1:3:6) Type C1 to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in 100mm dia pipe.
S&F 75mm dia PVC (SWR) bend with or without oval access door complete all as specified and as directed.
S&F 110mm dia PVC (SWR) bend with or without oval access door complete all as specified and as directed.
S&F 75mm dia PVC (SWR) branch piece (single Y) equal or unequal with oval access door complete all as specified and as directed.
S&F 110mm dia PVC (SWR) branch piece (single Y) equal or unequal with oval access door complete all as specified and as directed.
S&F 75 mm dia PVC (SWR) junction single, (Single T) equal or unequal
S&F 110 mm dia PVC (SWR) junction single, (Single T) equal or unequal
S&F in repair 110 mm dia PVC (SWR) Vent Cowl
S&F in repairs SS Grating round of 125 mm size complete all as specified and as directed
M&L in repair 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed
S&F in repairs PVC Flexible waste pipe 32/40 mm Dia for wash hand basin / kitchen sink complete all as specified and as directed.
S&F in repairs 32 mm waste fittings of brass chromium plated and waste coupling of PTMT glazed ware sinks and basins etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed in repairs (Half or full threaded)
S&F in repairs 40 mm waste fittings of brass chromium plated and waste coupling of PTMT glazed ware sinks and basins etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed in repairs (Half or full threaded)
M&L for providing precast Reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) and set in cement mortar 1:6 in landings, cover slabs (for man holes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including form work complete. Note : TMT required shall be measured and paid separately.
M&L for precast cement concrete block masonary using PCC 1:3:6 type C-5 soild block exceeding 10cm in width and setting in cement mortar 1:6 straight or surved on plan exceeding 6m mean radius complete all as specified and as directed by Engineer-in-Charge
M & L for 15 mm thick cement plaster in CM 1:3 on concrete surfaces mixed with water proofing compound as per manufactures instruction,finished even and smooth and after ponding test surface shall be dried and bottom and sides of the sunken slab shall be treated with two coats of surface application using approved water proofing compound as per manufactures instructions all as specified and as directed. Note : WPC shall be measured and paid seperately as "supply only"
M & L for applying a coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm over a coat of bituminous primer @ 0.3 Kg/Sqm complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls or concrete surface, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M & L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6(Total 15 mm thick) on concrete or brick masonry surfaces including mixing water proofing compound as per manufacurers instructions and finishing the top surface even and fair complete all as specified and as directed. Note : WPC shall be measured and paid seperately as "supply only"
Supply only Integral water proofing compound ISI marked .
M & L for rendering to concrete or block masonry surfaces or surfaces other than fair faces of brick surfaces, 10mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L rendering 5mm thick in CM (1:3) on ceiling surfaces finished even & smooth without using extra cement complete all as specified and as directed.
Dismantling floor hearth or wall tiles including cement mortar bedding (but not backing) removing serviceable to store and rubbish of the premises, complete all as directed by Engr-in-charge.
M&L for non skid ceramic coloured tiles 7-8mm thick exc 0.11 sqm but n.exc 0.18 sqm area of each tiles in floor / steps etc set and jointed in neat cement slurry and pointed in coloured cement to match as in floor over 15mm thick screed bed in CM (1:6) complete all as specified and as directed
M&L for glazed ceramic coloured tiles 300 X250 X 7mm / 450mm X 300mmx8 thick as in dado / skirting set and and jointed in neat cement slurry and pointed in coloured cement to match as in floor over 10mm thick screed bed in CM (1:3) complete all as specified and as directed
M& L for Machine pressed precast concrete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and as directed
M & L crushed stone sand cushioning for paver tiles including watering and consolidation complete all specified and directed complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all specified and directed complete all as specified and as directed
S&F mild steel framed work such as grills, Gratings etc, with ends of bars shouldered and / or riveted , or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways railings; framework of water tanks & similar work conforming to Fe-290-0 Gde E-165 complete all specified and directed complete all as specified and as directed
M&L for PVC coated GI chain link fencing 3.5mm dia with 50mm x 50mm mesh including fixing of MS line wire / rod, flat iron & machine made hexagonal or square head bolts to fencing posts including dismantling of fencing and fencing post complete all as specified. Note : MS rod,flat iron and bolts will be measured and paid seperately as "Supply only"
M&L Painting one coats of synthetic enamel paint including preparation of old steel surfaces of any description over 10cm in width or grith not other wise described complete all as specified and directed.
M&L preparing newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of wall putty and primer all as specified & directed
M&L for preparation of old disempered surface of walls and applying one coat of oil bound distemper all as specified and directed.
M & L for preparation of surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and as directed
M&L for complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/liter and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 liter/ 10 sqm over old surfaces complete all as specified and as directed
M & L for preparation of old plastered wall surfaces and applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/liter and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm complete all as specified and as directed by Engr-in-Charge.
M&L for Plain Cement Concrete Type D2 1:4:8 using 40 mm graded stone aggregate as in foundations, filling and mass concrete for foundation including formwork all as specified and directed
M&L for coloured heavy duty vitrified coloured tiles 300X300X10 mm thick of each tiles in floor/ steps/stairs etc set jointed and pointed in neat cement slurry in floors including 15mm thick in CM 1:6 complete all as specified and directed
M&L for mild steel work in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and as directed.
M&L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced exc 100 sqcm n exc 250 sqcm all as specified and directed
Dismantling plain or corrugated steel sheeting of any gauge and thickness including nainital or similar pattern roof coverings including ridges complete all as specified and as directed by Engr-in-Charge
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as manufacturers instruction and as directed.
S&F Pre-painted galvalume aluminium zinc coating plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as manufacturers instruction and as directed.
S & F Aluminium flat work in hand rails, wind ties screwed as directed, including all necessary drilling, bolting or riveting etc., and similar work complete all as specified and directed.
Dismantling posts of any description , including taking out embedded portion and making good disturbed ground complete all as manufacturers instruction and as directed.
Excavating in post holes in hard/dense soil n.exc. 0.5 cum and getting out returning, filling in and ramming in layers n.exc. 25 cm, watering and removing surplus soil to a distance n.exc. 50 mtr and making good the surface complete all as manufacturers instruction and as directed.
MS framed work such as fencing post including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as manufacturers instruction and as directed. Note: MS bar,flat iron,MS screw bolts & nuts required shall be measured and paid separately as "Supply only"
Supply only mild steel screw bolts 10mm dia machine made with hexagonal or square head at one end and screwed the other or screwed both ends for fixing of chain link fencing complete all as manufacturers instruction and as directed.
Supply only MS bars for support to chain link fencing complete all as specified and as directed.
Supply only MS Flat iron as in fillets for securing wire mesh including all necessary drilling, bolting or riveting etc and similar work confirming to Fe-410-0 to Fe-310-0 complete all as manufacturers instruction and as directed.
M&L for two coats of synthetic enamel paint over a coat of Red oxide primer including preparation of new steel/iron surface of any description n.exc10 cm in width or girth complete all as manufacturers instruction and as directed.
M&L Painting two coats of synthetic enamel paint over a coat of red oxide including preparation of new steel surfaces of any description over 10cm in width or grith not other wise described complete all as specified and directed.
M&L preparing newly plastered surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as manufacturers instruction complete all as manufacturers instruction and as directed.
Material and Labour for mild steel work in doors or gates of angle or other section with gusset plates, rails braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed by Engr-in-Charge
M/s J. M. Enterprises
M/s Shiva Engineering
KHOTEL CONSTRUCTION
Shri K.T. Manoj
V CHINNA DURAI
EXCEL ENGINEERING WORKS
S BOSE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .