| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC H NO 1215 NEAR RAM MANDIR PONTEMOL CURCHOREM GOA 403706 | SOUTH GOA | GOA | 403706 | L1 | Accepted-AOC Lowest bidder | |
| 2 | Rejected-Technical MENEZES BHAT ST JOSE DE AREAL NESSAI CURTORIM MARGAO GOA 403709 | MARGAO | SOUTH GOA | GOA | 403709 | - | Rejected-Technical bidder does not meet the technical requirement |
Tender Value
₹16.5 L
EMD Value
₹33,014
Closing Date
15 Jan 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Elect Div-VII, Curchorem
Executive Engineer Elect Div-VII, Curchorem 403706
Tender for the work of arranging power supply to un-electrified houses at Gawliwada and Naqueri Village in Caurem-PirlaV.P., under the jurisdiction of Sub Division-II, Quepem, Division-VII, Curchorem.
2021_ED_2196_1
Tender 03(21-22)
Open Tender
Electrical Works
Item Rate
60 days
Caurem Pirla
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹33,014
O/o Executive Engineer Elect Div-VII, Curchorem
15 Sept 2023
17 Dec 2021
17 Jan 2022
17 Dec 2021
15 Jan 2022
24 Dec 2021
23 Dec 2021
180 days
Amount
Cost of material
Supply of Cement Concrete 1:2:4 (1-cement: 2-sand :4-graded granite/basaltic aggregate 20mm nominal size ) including the cost of centreing, shuttering & muffing 0.4mts above ground. (Inclusive of cost of erection). Supply as per the specification mentioned in Part C.
Supply of Enamelled danger board 11000V of size 250mm x 200 mm on poles using necessary HDGI clamps & nut bolts. Supply as per approved standard.
Supply of HDGI structure material. Supply as per the specification mentioned in Part C.
Supply of earthing with G.I pipes of size 8 feet long 40mm dia class B fabricated & perforated including alternate layers 30cm thick of charcoal salt (charcoal & salt-20kgs.each/pit) .Supply as per the specification mentioned in Part C.
Supply of 11KV, 200Amps HG Fuse unit. Supply as per the specification mentioned in Part C.
Supply of HDGI barbed wire as anticlimbing device (2mts. Length). Supply as per the specification mentioned in Part C.
Supply of MS Distribution box complete.M. S. distribution box alongwith MCCB of 400Amps and 12 nos. of 200 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals. Supply as per specification mentioned in Part C.
Supply of HDGI 11KV V-shape X-arm made out of channel ISMC 75x40x7.3mm on pin points with suitable clamps and nut bolts for 9mtr. Long RCC Pole. Supply as per the Specifications mentioned in Part C.
Supply of HDGI Top fitting cross arm ISMC channel, 75x40x6mm, 0.7mts long with suitable clamps and nut bolts. M.S. CHANNEL 75 X 40 mm ISMC of minimum tensile strength 410 MPA conforming to IS 2062 as amended upto date. Supply as per the Specifications mentioned in Part C.
Supply of 11KV HDGI Cut point cross arm ISMC channel, 75x40X6mm, 1.3mts long with suitable clamps and nut bolts. M.S. CHANNEL 75 X 40 mm ISMC of minimum tensile strength 410 MPA conforming to IS 2062 as amended upto date.Supply as per the Specifications mentioned in Part C.
Supply of 11KV guard cross arm of channel ISMC 75x40x6mm. 1.5mts. Long of minimum tensile strenght 410MPa conforming to IS 2062 as amended upto date along with clamps & nut bolts etc. Supply as per the Specifications mentioned in Part C.
Supply of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date. Supply as per the specification mentioned in Part C.
Supply of HDGI stay clamps for 9mtr long RCC pole shall be hot dipped galvanized generally conorming to IS-2633/72. Supply as per the specification mentioned in Part C.
Supply of HDGI X arm clamps L.A. for 9mtr long RCC pole shall be hot dipped galvanized generally conforming to IS-2633/72,. Supply as per the specification mentioned in Part C.
Supply of 11KV pin insulators with HDGI pin at pin points & cut points. Supply as per the Specifications mentioned in Part C.
Supply of 11KV 45KN disc insulator with 3 bolted type metal parts on cut points, end points & tapping points. Supply as per the specification mentioned in Part C.
Supply of DTC Metering unit, with DLMS protocol Energy Meter. Supply as per the specification mentioned in Part C.
Supply of Common Automatic Meter Reading (CAMR) Modems. (Inclusive of cost of erection). Supply as per approved standard.
Supply of LT shackle insulator with HDGI metal parts, HDGI nut bolts etc. at cut points & end points, Supply as per the Specifications mentioned in Part C.
Supply of AA ANT conductor 7/3.10mm nominal size aluminium 50sq.mm with maximum current capacity 190Amps at 40°C.for phase & binding on pin points & cut points Supply as per the specification mentioned in Part C.
Cost of erection
Erection of 9mts. long RCC poles by transportation to pit points by digging pit of size 0.60mtsX0.60mtsX1.5 mts.deep in all types of soil laterite/hard rock, including refilling of soil,leveling & disposal of extra soil, Erection of poles as per the specification mentioned in Part C.
Fixing of Enamelled danger board 11000V of size 250mm x 200 mm on poles using necessary HDGI clamps & nut bolts. Fixing as per approved standard.
Stringing of ACSR Weasel Conductor of size 6/1/2.59mm. Stringing as per the specification mentioned in Part C.
Fixing of HDGI structure material. Fixing as per the specification mentioned in Part C.
Installation, Fixing of 11KV GOAB switch 200amps with operating pipe support of class B, 25mm. Dia. Fixing as per the specification mentioned in Part C.
Providing and connecting of earthing with G.I pipes of size 8 feet long 40mm dia class B febricated & perforated including alternate layers 30cm thick of charcoal salt (charcoal & salt-20kgs.each/pit) inclusive of excavation backfilling and spreading of excavated earth evenly. Fixing, Providing and connecting as per the specification mentioned in Part C..
Fixing of 11KV, 200Amps HG Fuse unit. Fixing as per the specification mentioned in Part C.
Providing of HDGI barbed wire as anticlimbing device (2mts. Length). Fixing Providing as per the specification mentioned in Part C.
Fixing of 9KV,5KA lightening arrestor along with clamps and nut bolts. Fixing as per the specification mentioned in Part C.
Erection of MS Distribution box complete.M. S. distribution box alongwith MCCB of 400Amps and 12 nos. of 200 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals. Erection as per specification mentioned in Part C.
Fixing of HDGI 11KV V-shape X-arm made out of channel ISMC 75x40x7.3mm on pin points with suitable clamps and nut bolts for 9mtr. Long RCC Pole. Fixing as per the Specifications mentioned in Part C.
Fixing of HDGI Top insulator fitting for RCC pole. Fixing as per the approved standard and as per Specifications mentioned in Part C.
Fixing of HDGI Top fitting cross arm ISMC channel, 75x40x6mm, 0.7mts long with clamps. M.S. CHANNEL 75 X 40 mm ISMC of minimum tensile strength 410 MPA conforming to IS 2062 as amended upto date. Fixing as per approved standard and as per Specifications mentioned in Part C.
Fixing of HDGI Cut point cross arm ISMC channel, 75x40x6mm, 1.3mts long with clamps. M.S. CHANNEL 75 X 40 mm ISMC of minimum tensile strength 410 MPA conforming to IS 2062 as amended upto date. Fixing as per approved standard and as per Specifications mentioned in Part C..
Fixing of 11KV guard cross arm of channel ISMC 75X40x6mm. 1.5mts. Long of minimum tensile strenght 410MPa conforming to IS 2062 as amended upto date along with clamps & nut bolts etc. Fixing as per the as per approved standard and as per Specifications mentioned in Part C..
Laying of XLPE cable armoured 3½ crore 120 Sq.mm 1.1KV Grade. Laying, connecting as per the specification mentioned in Part C.
Laying of XLPE cable armoured 3½ crore 95Sq.mm 1.1KV Grade. Laying, connecting as per the specification mentioned in Part-C
Erection of Distribution Transformer 100 KVA.11/0.433KV, 50HZ, Level II, outdoor type, oil immersed, core type, Oil Natural Air Natural Cool type, Delta Star Dy11 aluminium wound, distribution transformer (without taps) Erection as per specification mentioned in Part C.
Providing of all aluminium crimp lugs of size 120Sq.mm. Fixing as per the specification mentioned in Part C.
Providing of all aluminium crimp lugs of size 95Sq.mm. Fixing as per the specification mentioned in Part C.
Providing of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date. Fixing as per the specification mentioned in Part C.
Fixing of HDGI stay clamps for 9mtr long RCC pole shall be hot dipped galvanized generally conorming to IS-2633/72. Fixing as per the specification mentioned in Part C.
Fixing of HDGI X arm clamps S.A. for 9mtr long RCC pole shall be hot dipped galvanized generally conforming to IS-2633/72,. Fixing as per the specification mentioned in Part C.
Fixing of HDGI X arm clamps L.A. for 9mtr long RCC pole shall be hot dipped galvanized generally conforming to IS-2633/72,. Fixing as per the specification mentioned in Part C.
Fixing of 11KV pin insulators with HDGI pin at pin points & cut points. Fixing as per the Specifications mentioned in Part C.
Providing of 11KV 45KN disc insulator with 3 bolted type metal parts on cut points, end points & tapping points. Fixing as per the specification mentioned in Part C.
Erection of HDGI stay set complete comprising of HDGI stay rod with plate, HDGI turn buckle with eye bolt, Break insulator of 15KV, suitable HDGI stay Clamps, HDGI Stay wire of size 7/10swg and HDGI nut bolts for 9mtr long RCC pole. Erection as per the specification mentioned in Part C.
Providing of DTC Metering unit, with DLMS protocol Energy Meter. Installation, Fixing as per the specification mentioned in Part C.
Erection of 7.5mts. R.C.C. poles long by transportation to pit points by digging Pole pit of size 0.60mtsX0.60mts X1.25mts. deep in all types of soil laterite/hard rock, including re-filling of soil ,including leveling & disposal of extra soil. Erection as per the specification mentioned in Part C.
Fixing of HDGI 4pin X arm of made of channel ISMC 75X40X6mm with suitable Clamps and nut bolts for 7.5mtr. Long RCC Pole Fixing as per the specification mentioned in Part C.
Fixing of LT shackle insulator with HDGI metal parts, HDGI nut bolts etc. at cut points & end points, Fixing as per the Specifications mentioned in Part C.
Fixing of LT pin insulators with HDGI Pin at pin points. Fixing as per the specification mentioned in Part C.
Erection of HDGI stay set complete comprising of HDGI stay rod with plate, HDGI turn buckle with eye bolt, Break insulator of 8KV, suitable HDGI stay Clamps, HDGI Stay wire of size 7/10swg and HDGI nut bolts for 7.5mtr long RCC pole. Erection as per the specification mentioned in Part C.
Stringing of AA ANT conductor 7/3.10mm nominal size aluminium 50sq.mm with maximum current capacity 190Amps at 40°C.for phase & binding on pin points & cut points Stringing as per the specification mentioned in Part C.
Stringing of AA GNAT conductor 7/2.21mm nominal size aluminium 25sq.mm with maximum current capacity 80Amps at 40°C.for phase & binding on pin points & cut points & for providing lacings. Stringing as per the specification mentioned in Part C.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .