Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.2 LAccepted-AOC | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹22.3 L+₹5,930 (0.27%)Rejected-AOC | L-2 | Rejected-AOC Other than lowest bidder | |
| 3 | L-3₹25.1 L+₹2.9 L (12.9%)Rejected-AOC R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L-3 | Rejected-AOC Other than lowest bidder | |
| 4 | L-4₹34.7 L+₹12.5 L (56.4%)Rejected-AOC | L-4 | Rejected-AOC Other than lowest bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
13 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Tanuj Bagla, IDSE
GE Kaluchak PIN-900673 C/O 56 APO
REPAIR/REPLACEMENT OF MISC E/M PLANTS, PERIMETER LIGHTS AND EQPT INCLUDING SERVICING OF DISINFECTION PLANTS AND STANDBY- SETS AT MIL STN BD BARI UNDER GE KALUCHAK.
2024_MES_679738_1
GE/KC-60/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kaluchak
Please refer Tender documents
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹96,000
Yes
14 Jan 2025
16 Oct 2024
15 Nov 2024
16 Oct 2024
13 Nov 2024
30 Oct 2024
Amount
Servicing of DG Set 100 KVA of any Make, checking entire system as per manufacturer's catalogue such as checking all parts for serviceablility, taking down defective parts such as fuel filter assy, by pass filter assembly, lub oil filter assembly, air cleaner assy,air filter, flexible hose pipe, radiator coolent , distill water, Tightening the base bolt and nuts and mounting bolts and nuts. etc and replacing the same with same size, make and capacity of parts, draining out the old used burnt engine oil from the sump cleaning all serviceable filters and oil sump with cleaning solution such as petrol/ diesel and refilling new engine oil upto required level, cleaning of battery terminals with warm water ,Checking the radiator and radiator hose and arresting small leaks ,Checking the fuel pump timing and adjusting if required and including testing to DG Set to entire satisfaction of Engr-in Charge. Note:- (i) Spare parts/ Engine oil/ check kit/ filter shall be measured and paid for saperately under respective items of BOQ (ii) Minimum 6 months gap/ 200 hrs of run whichever is earlier shall be considered for next service (iii) Repair Guarantee for replaced parts/servicing of DG Set shall be for six month/200 hrs from the date of service. (iv )Cost of small spares required for maint of DG set shall be deemed to be included in the unit rate quoted. (v) Service Engineer must be skilled and must have knowledge of maintenance of DG sets and attending minor and major fault when it arise.
All as per item No 1 here-in-before but for DG set 62.5 KVA.
All as per item No 1 here-in-before but for DG set 50 KVA.
All as per item No 1 here-in-before but for DG set 40 KVA.
All as per item No 1 here-in-before but for DG set 30 KVA.
All as per item No 1 here-in-before but for DG set 10 KVA.
Supply only Air filter element (OEM )suitable for 10 KVA Capacity
Supply only Air filter (OEM) suitable for 30 KVA Capacity
Supply only Air filter (OEM) suitable for 40 KVA Capacity
Supply only Air filter (OEM) suitable for 62.5 KVA Capacity
Supply only Air filter (OEM) suitable for 100 KVA Capacity
Supply only Diesel filter (OEM manufactured ) capacity 1/2 litre with'O' ring (Primary & secondary) suitable for 10 KVA Diesel engine
Supply only Diesel filter (OEM manufactured ) capacity 1/2 litre with'O' ring (Primary & secondary) suitable for 30 KVA Diesel engine
Supply only Diesel filter (OEM manufactured ) capacity 1/2 litre with'O' ring (Primary & secondary) suitable for 40 KVA Diesel engine
Supply only Diesel filter (OEM manufactured ) capacity 1 litre with'O' ring (Primary & secondary) suitable for 50 KVA Diesel engine
Supply only Diesel filter (OEM manufactured ) capacity 1 litre with'O' ring (Primary & secondary) suitable for 62.5 KVA Diesel engine
Supply only Diesel filter (OEM manufactured ) capacity 1 litre with'O' ring (Primary & secondary) suitable for 100 KVA Diesel engine
Supply only water separator (OEM manufactured ) capacity 1/2 litre with'O' ring suitable for 10/15 KVA Diesel engine
Supply only Water separator (OEM manufactured ) capacity 1/2 litre with'O' ring suitable for 30/35 KVA Diesel engine
Supply only Water separator (OEM manufactured ) capacity 1 litre with'O' ring suitable for 40/45 KVA Diesel engine
Supply only Water separator (OEM manufactured ) capacity 1 litre with'O' ring suitable for 50 KVA Diesel engine
Supply only Water separator (OEM manufactured ) capacity 1 litre with'O' ring (Pre & Micro) suitable for 62.5 KVA Diesel engine
Supply only Oil filter (OEM manufactured ) capacity 1/2 litre with'O' ring suitable for 10/15 KVA Diesel engine
Supply only Oil filter (OEM manufactured ) capacity 1/2 litre with'O' ring suitable for 30/35 KVA Diesel engine
Supply only Oil filter (OEM manufactured ) capacity 1 litre with'O' ring suitable for 40 KVA Diesel engine
Supply only Oil filter (OEM manufactured ) capacity 1 litre with'O' ring suitable for 50 KVA Diesel engine
Supply only Oil filter (OEM manufactured ) capacity 1 litre with'O' ring suitable for 62.5 KVA Diesel engine
Supply only Oil filter (OEM manufactured ) capacity 1 litre with'O' ring suitable for 100 KVA Diesel engine
Supply only Rocker cover/ sump packing kit(OEM manufactured ) suitable for 30/35 KVA Diesel engine
Supply only Rocker cover / sump packing kit (OEM manufactured ) suitable for 40/45 KVA Diesel engine
Supply only Rocker cover / sump packing kit (OEM manufactured ) suitable for 50 KVA Diesel engine
Supply only Rocker cover / sump packing kit (OEM manufactured ) suitable for 62.5 KVA Diesel engine
Supply only Rocker cover / sump packing kit (OEM manufactured ) suitable for 100 KVA Diesel engine
Supply only Fuel line (OEM ) set complete with clamps suitable for 10/15 KVA Capacity
Supply only Fuel line (OEM ) set complete suitable for 30/35 KVA Capacity
Supply only Fuel line (OEM ) set complete suitable for 40/45 KVA Capacity
Supply only Fuel line (OEM ) set complete suitable for 50 KVA Capacity
Supply only Fuel line (OEM ) set complete suitable for 62.5 KVA Capacity
Supply only Fuel line (OEM ) set complete suitable for 100 KVA Capacity
Supply only Low lube Oil pressure sensor (OEM ) complete suitable for 15/20/25/30/40/62.5 KVA Capacity genset
Supply only Low lube Oil pressure sensor (OEM ) complete suitable for 100 KVA Capacity genset
Supply only Water hose pipe kit (OEM) complete with clamps and nuts and bolts suitable for 30/40/50/62.5 KVA
Supply only Engine oil 15W40 as per manufacturers recommended
Supply only water coolant suitable for diesel engine as per manufacturers recommended.Make TVS-Girling /K-Cool/ Castrol
Supply only Distilled water for filling in batteries complete all as specified and directed.
Supply only Fanbelt (V Belt) suitable for the following capacity of DG set installed at various installations :- (a) Battery Charging Dynamo Belt (b) Water Pump Belt
(i) 15 to 30 KVA
(ii) 40 to 62.5 KVA
(iii) 100KVA to 125 KVA
Taking down / Dismantling unserviceable self starter 12 volts from engine of DG Set , opening of stator and armature for repairing by replacing the worn out carbon brushes, brush holder, bearings, ignition / solenoid coil, replacement of burnt armature, rewinding of field coils, replacement of pinion gears,bushing etc, complete servicing , varnishing of stator /armature and refixing after repair, testing / commissioning complete for DG Set any capacity complete all as specified and as directed.
Suply and fixing in repair battery terminals (positive and negative) brass heavy duty complete suitable for fixing on battery poles with bolts,nuts and washers complete including taking down unserviceable battery terminals complete all as specified and as directed.
S&F in replacement maintenance free lead acid battery 12 volts 180 AH confirming to IS 7372 complete all as specified and as directed.
S&F in replacement maintenance free lead acid battery 12 volts 150 AH confirming to IS 7372 complete all as specified and as directed.
S&F in replacement maintenance free lead acid battery 12 volts 90 AH confirming to IS 7372 complete all as specified and as directed.
S&F in replacement LVM Contactor Model No KCL34 84 Amps with suitable Auxiliary contact 2NO-2NC, complete all as specified and as directed.
S&F in replacement Voltage Monitoring Relay Model : VMRD-MSP, complete all as specified and as directed.
Servicing and maintenance of existing Chemical Dosing system suitable to inject solution upto 25 LPH comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit of make satya sai including replacement of unserviceable part at site chemical dosing system & changing of Teflon gland packing and cleaning of NRV set, checking the complete system complete all as specified and as directed.Make of Plant : Sathya Sai Services .Notes :1. Servicing shall be carried out by the company rep and the rate for this shall deemed to be included in item. 2. Spares shall be of original manufacturer only.3. Spares shall be paid and measured and seperately under as Supply only as mentioned here-in-after :-
(a) PVC adopter for suction and delivery without NRV.
(b) PVC strainer washer type heavy duty or Y type strainer for suction.
(c) Teflon gland square type 3 mm
(d) Chemical Oil seal with cap
Taking down brunt unserviceable Automatic Voltage Regulator assy from alternator of DG set by disconnecting its electrical connections, supply and fixing new AVR 12V suitable for 20 to 45 KVA DG Set including connecting all electrical connections. Testing voltage after starting engine and setting properly if a difference all as specified and directed.
Taking down brunt unserviceable Automatic Voltage Regulator assy from alternator of DG set by disconnecting its electrical connections, supply and fixing new AVR 12V suitable for 62.5-100KVA DG Set including connecting all electrical connections. Testing voltage after starting engine and setting properly if a difference all as specified and directed.
Disconnecting, removing and dismantling radiator assembly from the following capacity DG sets and descaling the radiator throughly with CTC solution/ any other chemical solvent agent as approved by the Engineer-in-charge, stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enamelled paint etc., re-installing and commissioning complete all as specified and as directed .
(i) 20 to 30 KVA capacity genset
(ii) 40 to 62.5 KVA capacity genset
(iii) 100 to 125 KVA capacity genset
Taking down the existing unserviceable water pump assembly for the following capacity DG sets installed at various installation and replaced with new water pump assembly complete all as specified and as directed .
(i)20 to 40 KVA
(ii) 100 KVA
Material and labour for disconnecting electrical and mechanical connections of the following capacity altrernator, 415V, 50 HZ removing from foundation/ diesel engine coupling and transporting private work shop, dismantling the alternator in parts and removing the burn out copper winding coil carefully, cleaning slots and replacing the insulation paper and re-winding 'F' class copper conductor winding wire of existing size/ shape, glass sleeves of connecting leads, binding/ tightening loose coils with binding cloths, varnishing and applying the bactol on the excitor coil/ winding with supper varnish, heating the windings at appropriate tempeature to achive required insulation resistance with out damaging the other parts, replacement of driving and non-driving end bearings, cleaning, greasing, reassembling/ installing/ connecting and testing with megger for insualtion resistance etc., complete all as specified and as directed . Notes :- (i) Rewinding of alternator, repairing of main shaft replacement of unserviceable bearings are deemed to be included in the unit rate. (ii) Replacement of AVR will be measured and paid separately under relevant item. (iii) Minor parts required to make the alternator serviceable are deemed to be included in the unit rate. (iv) Make of Diesel Engine Generator is Kirloskar / Ruston / CG / Sudhir
(ii) 62.5/50 / 40 KVA
(iii) 20 / 25 / 30 / 31.25 KVA
Taking down the existing defective injector and fuel injection pump (FIP) for the following capacity DG set installed at various installation and replacement of worn out spares like delivery valves, nozzles, bearings, fly weight, packing kit, and copper washer kit ,injector element,kit injector,retainer injector cup, fixing tappit cover packing set,and recalibration of FIP and refixing in same position and testing of full load checking of pressure and adjustment by dial gauge complete all as specified and as directed .
(ii) 30 / 40 KVA
(iii) 10 / 20 / 25 KVA
Dismantling unserviceable battery charging dynamo from DG set of rating 12 Volts and providing complete repairs and servicing including replacement of bushes, bearings, carbon brushes, rectifiers, rewinding of field magnet coil / rotor armature coils and any other minor parts required all as directed and fixing on engine testing/commissioning complete for DG set having capacity 10KVA to 62.5KVA complete all as specified and as directed.
Dismantling old unserviceable battery charging dynamo of rating 12 volts and supply and fixing new battery charging dynamo same as per existing model suitable for fixing on DG set having capacity 100 KVA, 1500 RPM including testing after complete installation all as directed and specified. Make : LUCAS / SPT
M & L for Electronic Type Starting Switch for 15KVA to 62.5 KVA including removal of extg unsv one compete all as specified.
M & L for Feed pump suitable for 7.5 KVA to 63 KVA including removal of extg unsv one compete all as specified.
Taking down the existing defective DC ammeter and volt meter from the panel and replaced with new combined DC ammeter and Volt meter including necessary wiring and wiring material complete all as specified and as directed .
S&F in repair engine safety unit (ESU) alongwith meter for pressure, fuel, RPM etc. with all electrical instruments and accessories including taking down unserviceable SU with testing complete all as specified and directed.
Supply and fix in repair on load change over switch in sheet metal enclosure 100Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed.
Supply and fix in repair on load change over switch in sheet metal enclosure 63 Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed.
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 25KA,rating 63Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge.
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 25KA,rating 100Amp,complete as per OEM standard design,all as specified and as directed .
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 25KA,rating 125Amp,complete as per OEM standard design,all as specified and as directed .
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 25KA,rating 160Amp,complete as per OEM standard design,all as specified and as directed.
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 25KA,rating 200Amp,complete as per OEM standard design,all as specified and as directed.
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 25KA,rating 250Amp,complete as per OEM standard design,all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5metre below the ground level connected to GI strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 40 mm bore medium grade for protection of earth strip, PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways, CI frame and charcoal dust and common salt, all as shown in electrical plate No. 3 of MES SSR part-I and making test point as specified including excavation & earth work in any type of soil and connecting the earthing to an earthing point/equipment as specified and directed & testing on completion.
Earthing complete with galvanised steel earth plate electrode 60cmx60cm.x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test point, 20 mm bore medium grade GI watering pipe, 15mm bore light grade GI protection pipe, PCC chamber with RCC cover, funnel with wire mesh etc including necessary test including taking down of existing earthing, on completion all as specified and as directed.
Material and labour servicing and cleaning of oil cooled servo voltage stabilizer 30-50KVA by transporting to workshop , carefully lifting of core from the tank by opening cover, cleaning of tank, removing of sediments, cleaning of coils/ electrical connections, filtration of transformer oil ,fixing the core back in the tank, making electrical connections by replacing the consumble spares such as gaskets, rubber oil seals complete etc but other spares as listed here-in-after shall be replaced and cost of spare parts as" supply only shall be measured and paid separately under relevent item iron padling back at work site ,working electrical coinnection all complete as directed by Engr-in-charge capacity servo voltage stabilizer 100 KVA single/ 3 phase. Note: (i) Spare parts required to make serviceable of above oil cooled sevo voltage stabilizer shall be measured and paid separately under relevant item here-in-after. (ii) Rewinding of barrier assembly and transformer assembly will be measured and paid separately.)
Supply only the following spare parts / components to be incorporated against serial item No 68 here in before
(a) Copper Dimmer stat 40A
(b) Servo Motor 3 KG with RC network
(c) Carbon brush 40A with holder
(d) Controlling circuit
(e) Aluminium arm set 32A
(f) Pipe bush
(g) Current collector plate copper
(h) Indicating lamps
(j) Toggle switch
(k) Voltmeter 0-500V
(l) Input Output connection busbar with bakelite
(m) Fresh transformer oil(top up)
Dismantling &Taking down unserviceable street light fittings LED Fittings/ CFL Fittings,post top lantern,garden light, Pin /Holder type from pole or from Bldgs for repairs including replacement of unserviceable Lamp, holder, integral wiring with appropriate gauge copper conductor and refixing the same after repairs in original position properly using PVC insulation tape or where directed complete including replacement of any spares,cable connections from OH conductors,or from junction boxes to light fitting all as specified and as directed. Note : Spares items such as LED driver and cable etc, will be measured and paid separately under respective items.
Dismantling and taking down broken/damaged PCC/Steel pole all as specified and directed
Taking down old u/s cable all as specified and directed
Supply & Fixing in replacement of the following spare parts in street lights :-
PVC insulated weather proof sheated alluminium cable 2.5 sq mm 2 core
LED Driver 60 Watt of Make Bajaj/Equivalent
LED Driver 90 Watt of Make Bajaj/Equivalent
LED Driver 120 Watt of Make Bajaj/Equivalent
Supply and fixing in replacement Integral LED security light luminaire 90W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed.
Supply and fix Integral LED security light luminaire 60W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed
Supply and fix Integral LED security light luminaire 35W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed
Supply and fix Integral LED security FLOOD light luminaire 120W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed.
M&L outdoor type street light junction boxes with PVC water tight encloser, ready made type, with provision of suitable aluminium bus bars for three phases and one neutral mounted on insulators and bus bar having provision of 10 A SP MCB terminal connection and inter connection of street light from pole to pole and pole to light fittings including necessary PVC insulated waather proof twin core 2.5 Sqmm (nominal area) aluminium conductor cable, 1100 volts grade drawn and including PVC conduit of suitable size with clamps (3 Nos) , nuts, bolts etc from Junction box to street light connection, including taking down of existing unserviceable of junction box complete all as specified and as directed .
M&L for steel tubular poles complete with cast iron base plate, final taper plug, bolt, nuts and screws as specified type 410 SP-31(9 mtr long). Including painting pole with two coats of bituminous paint internally and external embedded portion in ground concrete and painting exposed surface with two coats of aluminum paint over one coats of aluminum paint over one coat of red oxide primer including taking down of existing LT pole of any size and re-fixing of chaneel, insulator and electric connection etc, all as specified and directed by the Engineer-in-Charge.
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 70 Sqmm 3.5 core with necessary cable lugs, ncluding taking down unserviceable cable, complete all as specified and directed by Engr-in-Charge..
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 50 Sqmm 3.5 core with necessary cable lugs, ncluding taking down unserviceable cable, complete all as specified and directed by Engr-in-Charge..
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 35 Sqmm 3.5 core with necessary cable lugs, ncluding taking down unserviceable cable, complete all as specified and directed by Engr-in-Charge..
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 25 Sqmm 3.5 core with necessary cable lugs, ncluding taking down unserviceable cable, complete all as specified and directed by Engr-in-Charge..
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 16 Sqmm 4 core with necessary cable lugs, including taking down unserviceable cable, complete all as specified and directed by Engr-in-Charge..
All as per item No- 96 here in before but 16 Sqmm 2 core
All as per item No- 96 here in before but 10 Sqmm 2 core
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft/loose soil, complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth for foundation, laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft/loose soil, complete all as specified and directed by the Engineer-in-Charge..
Returning , filling in , with approved excavated soil including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge. .
Removing excavated material (soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Supply and laying dry burnt bricks, sub class ‘B’ old size in cable trenches, as cable protection complete all as specified and directed by Engr-in-Charge.
Dry sand cushioning to under ground electric cable on layer of 08 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of M.E.S Schedule Part-I complete all as specified and directed by Engr-in-Charge.
M&L for Cutting/Boring of road/Hard standing to a size of 30 cm in width and not exceeding 60 cm in depth for laying of protection pipe/water line/Cable including returning filling, Including spreading and providing PCC in 1:2:4 B1 using 20 mm grade stone aggregate for the top 100mm layer, complete all as specified and directed.by Engr-in-Charge
Supply and laying galvanised iron pipe 40mm bore light grade fixed to poles with steel clamps laid under road crossing, fixed to wall etc complete all as specified and directed by Engr-in-charge.
Material and labour for P.C.C (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole and filling of mass concrete including providing necessary form work complete all as specified and as directed
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping to existing and new poles including necessary form work removing the debris to a distance n.exc. 50m complete all as specified and as directed
M&L for street light bracket made out of 32 mm dia GI pipe medium grade 120 cm long cut to size and bend to shape , fixing on poles with flat iron clamps 40mm x 6 mm – 02 sets including nuts, bolts and washers including one coat of aluminium pait over acoat of red oxide primer including taking down of old unserviceable complete all as specified.
Sarbat Construction Co (BID ID -3158615)
M/S Chib Engineers (BID ID -3164510)
VEE ESS ENGINEERS (BID ID -3157990)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .