| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.0 L+₹1.4 L (13.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹12.1 L+₹1.6 L (14.7%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹13.0 L+₹2.4 L (22.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹13.7 L+₹3.1 L (29.2%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹19.6 L
EMD Value
₹39,280
Closing Date
27 Jul 2023, 6:00 pmClosed
GE North Delhi Cantt-10
GE North Delhi Cantt-10
REAPIR MAINT OF INTERNAL ELECTRIFICATION WORK SERVICES WITH REPLACEMENT OF UNSV WIRING VARIOUS TYPE OF LIGHT FITTINGS AND FIXTURES DB SUBMAIN WIRING INCLUDING MAINT OF SUMMER AND WINTER APPLIANCES WITH CONNECTED ITEMS OF MD OTM CFLOFFICE 339 ASC DPDO
2023_MES_606817_1
GE/NORTH-58/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE North Delhi Cantt-10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE North Delhi Cantt-10
₹39,280
Yes
25 Sept 2023
30 Jun 2023
29 Jul 2023
30 Jun 2023
27 Jul 2023
14 Jul 2023
Amount
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling rose, holder, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete
Taking out Unseviceable main switch DB, MCB DB existing Complete
M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per srl No 03 here in before but One light point controlled by one switch of 6Amp
All as per srl item No 03 here-in-before but one fan point controlled by one, one way switch 06 Amps
All as per srl item No 03 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch
All as per srl item No 03 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
All as per srl no.03 here in before but One bell point controlled by one bell push switch of 6Amp
All as per Serial Item No 03 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed
M&L for point wiring with single core FRLS, PVC insulated, unsheathed multi stranded copper conductor of size 1.5 sqmm alongwith 1.5 sqmm earth wire of multi strand copper conductor (with same specification) drawing through existing conduit pipe including replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete for the following :-
All as per srl No 05 here in before butOne light point controlled by one switch
All as per srl No 05 here in before but One ceiling/exhaust fan point controlled by one switch
All as per srl No 05 here in before but One socket outlet 5 Amps controlled by one switch on same board
All as per srl No 05 here in before but One socket outlet 5 amps controlled by one switch on independent board
All as per srl No 05 here in before but One bell point controlled by one bell push switch
All as per the description of srl item No 05 above but wiring with 2.5 sqmm copper wire and 2.5 sqmm earth wire for socket out let 16 Amps on independent board
S&F in repair Switch piano flush type 5/6 Amps single pole one way 230 Volts complete
S&F in repairSwitch piano flush type 15/16 A single pole one way 230 Volts complete
S&F in repair Socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volt complete
S&F in repair Socket Outlet 2 in 1, 3/6 pin 5 and 15 Amp flush type 230 Volts complete
S/F in repair Bell push, flush type 5 Amps 230 Volts complete
S&F in repair electronic fan step regulator fiush type 120 watt, 230 Volt complete
S&F in repair lamp holder, 230 volt AC, PVC / Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb inverter type upto 4 Hrs back up 6500 K complete all as specified & directed
S&F in repair modular switch, 06 Amps, single pole, one way, 250 volts, one module and IP 20 protection complete all as specified & directed
S&F in repair modular bell push with indicator, 06 Amps, single pole, one way, 250 volts complete all as specified & directed
S&F in repair modular switch, with indicator, 16 Amps, single pole, one way, 250 volts, one module complete all as specified & directed
S&F in repair modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed
S&F in repair modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed
S&F in repair ceiling fan modular regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts, duly ISI marked complete
S&F in repair ding dong bell, AC, 230 volts, single pole complete all as specified & directed.
S&F in repair ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete.
Supplying and laying in replacement or fixing or passing through pipe, 1100 volts grade PVC insulated aluminium stranded conductor cable, unarmoured, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circuler for the following size of cables :-
S&F in repair surface/ceiling mounted LED panel type of size 2ft x 2ft, 36W, 230V, 5700K complete with driver full window glarefree opal diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete
S&F in repair wall mounted LED batten with polycarbonate housing and initigrated electronic drive 20 watt fixture 4 feet provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete.
S&F in repair surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive, pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete.
S&F in repair decorative wall mounting, brushed nickel finish fixture with Opal glass diffuser suitable with 9 W LED lamp B22 base.(Make of Bulb : Havells/Philips/ Wipro), and all accessories pre-wired including connecting up complete.
S&F in repair LED Post top lantern luminaire with die cast aluminium spigot, lid cover and clear acrylic cover 70 watt, 5700 K with IP-65 protection incl connection complete.
S&F in repair LED Bulkhead luminaire of polycarbonate housing and enclosed with acrylic diffuser IP-65 protection incl connection complete.
S&F in repair LED security light fitting of 45 watts with pressure die-cast aluminium housing complete with all accessories, fixing of fitting on wall with necessary fixing arrangement, IP66 protection as required at site & connection complete suitable for pole dia 40mm.
S&F in repair exhaust fans AC single phase 230/240 V of size 300mm sweep with louver and depositing old exhaust fan to MES store complete all as directed.
S&F in repair Ventilating fan, wall mounted type of 250 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frame/all required arrangement for mounting of fan including making good of disturbed surface etc complete.
M&L in repair for submain wiring with two single core (submain) PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete
All as per the description of srl item No 31 above but with 6 sqmm and 6 sqmm as earth wire
S&F in repair MCB DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, IP-43, including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface complete for the following no of way :-
S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- (a) MCCB, 100 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete - 01 No. (b) MCB, SPN/SP 63A, AC,240 volts - 04 Nos.
S&F in repair MCB, DP/SPN, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete of following rating :-
S&F in repair MCCB 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line DB & connection complete of following rating :-
63 amps rating
100 amps rating
S&F in repair MCB, SP, AC, 240 volts of 6 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed. Note :- Testing of eathing after completion. the permissible resistence is not obtained the earthing will be redone at no extra cost.
S&F in repair AC single phase static energy meter of accuracy class 1.0, 240 V 50 Hz with Backlit LCD display of rating 10-60 A (measures and displays KWH,V,Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box and depositing old meter to MES store complete all as directed.
S&F in repair sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 'C' curve, 240 Volt complete
S&F in repair fans ceiling complete with blade ,down rod,electronic type regulator and accesoories 230 V, 1200 mm sweep. BLDC ,min air delivery 210 CFM with service value 6 BEE 5 star rated with brushless direct current motor energy saving and depositing old ceiling fans to MES store complete all as directed.
Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 10 sqmm 2 core nominal cross section complete
S&F in repair wall mounting fan 400 mm sweep, adjustable, plastic blade grill for protection, pull cord control for speed and oscillation on-off, ABS body incl connection complete all as directed
S&F (in replacement) LED landscape bollard outdoor garden light 10 watt, 230 volt, inverted pyramid tripod type with soft 360 degree distribution,600mm long IP-65 protection, incl necessary civil work for grouting & foundation work of suitable sizewith PCC work complete all as specified and directed
S&F in repair PVC flexible twin twisted copper conductor cable multi strand of size 0.5 sqmm nominal cross section complete
M&L for dismantling of unsv C/Fan of any make/model/sweep, cutting and removing the old defective/burnt winding, cleaning the core of fan motor and rewinding the fan motor with super enamelled copper winding wire of same gauge with insulating material and varnishing the core assembly, drying the moisture content to get appropricate speed and re-assemble the same complete all as directed Note :- The cost of copper winding wire is deemed to be included in the quoted rate
All as per the description of srl item No 46above but for exhaust fan upto 300mm sweep size
All as per the description of srl item No 46 above but for exhaust fan of 380/450mm sweep size
S&F in repair capacitor 2.5/3.15 MFD, ISI marked for C/fan incl connection complete
M&L in repair ball bearing suitable for any type/size/make of fan complete (Make-NBC/SKF)
Taking down carefully electric geyser of any type and capacity by disconnecting electric and water supply connection, opening nut, bolt, washer and replacing the defective parts and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and directed. Note: Spare items shall be measured and paid seperately as supply only under relevant items
Supply only geyser inner water tank 35/50Ltrs capacity steel body as per sample, duly tested complete all as specified and directed.
All as per the description of srl item No 53 above item but 25 Ltrs capacity
Supply only of Heating element capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser (as per sample) complete (Make : as per sample/ make as per existing geyser)
All as per the description of srl item No 55 above item but capacity 2 KW
Supply only thermostat suitable for 50/35/25 ltrs capacity geyser (Make :- as per sample/ make)
Supply only heavy duty hot water connection, SS rope threaded type with brass unions at both ends, 45cm long 15mm bore complete.
Supply only indicator lamp suitable for geyser of any type/capacity (Make as per sample)
Supply only geyser base plate assembly of any capacity any model complete (Make as per sample)
S&F in replacement of outer cover MS sheet/ABS body of geysers 25 to 50 Ltrs capacity complete all as directed
S&F in repair Plug top, 3 pin, 05 amps, 230 volt incl connection complete
S&F in repair Plug top, 3 pin, 15 amps, 230 volt incl connection complete
S&F in repair PVC insulated and sheathed flexible cable 3 core Multi-stranded copper conductor size 2.5 Sqmm 1100 volt grade after taking out old unserviceable one including electric connection complete
M&L for taking down carefully window/split type Air conditioner 2/1.5 Ton capacity of any type/make from window/wall and removing front grills, air filters and cleaning, removing dust, washing and servicing with chemical wash of cooling and condenser coil and re-assembling the dismantled components and fixing to its original position complete all as specified & directed
M&L for charging of refrigerant R-22 / R-410 or any other recommended refrigerant gas in 1.5/2 Ton window/split Air conditioner/ Refrigerator/ Water Cooler any cap including detecting leakage and rectify the leakage with proper brazing and testing on full load complete
S&F in repair starting relay suitable for air conditioner 1.5/2 Ton/ Water cooler/ Refrigerator any cap
M&L in repair copper tubing 1/2" dia with existing gauge for suction/discharge line of split air conditioner of 1.5 Ton/2Ton capacity including high quality puf insulation complete
All as per the description of srl item No 68 above but size 3/8" dia
S&F in repair plastic submersible pump suitable for desert cooler any size complete
S& F Desert coolar grasss pad .
S&F in replacement motor single phase, 1/5 HP capacity for split type AC 1.5/2.0 ton capacity complete (Make : As per sample/make)
S&F in replacement hermetically sealed rotary type compressor unit of capacity 1.5/2 T for split/window type AC and charging of adequate quantity of refrigerant gas and testing on completion complete Make : Blue Star/Carrier/Kirloskar/Hitachi/ Mitsubishi/Dakin
S&F in repair Power Circuit Board (PCB) suitable for split type AC of capacity 1.5 / 2.0 TR complete
S&F in repair electronic voltage stabilizer, single phase suitable for 1.5/2 Ton air conditioner having I/O correction range of 160-280 volt complete all as directed Make : Microtech/Blue Bird/V-Guard/Zenith/Sinetrac
S&F in repair ceramic porcelain heating element suitable for geysers of 25 ltr cap/ make as per sample
S&F in repair fan motor kit assembly of 450 mm sweep, single phase, not less than 145 watt, AC, 50 Hz, copper wound with blade for desert cooler complete all as directed
Microsys Controls India
MAHABIR SINGH
Jai Ambay traders
J.P. Enterprises
Commercial Traders
QUALITY CONSTRUCTIONS CO
J V ENGINEERS / JAI SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .