| 1 | L1₹11.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.5 L+₹1.6 L (13.6%)Rejected-Finance 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹14.5 L+₹2.6 L (21.5%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹16.9 L+₹5.0 L (41.7%)Rejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹17.4 L+₹5.5 L (46.3%)Rejected-Finance 5 L LEHAL COLONY PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
28 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Construction of launcher shelter at alpha FLT at AF Stn Jaisalmer
2022_MES_523277_1
8811/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹30,000
Yes
15 Jun 2022
10 May 2022
30 May 2022
10 May 2022
28 May 2022
23 May 2022
11 May 2022 - 14 May 2022
60 days
Amount
SHELTER WORK Excavation in over areas not exceeding 1.5m deep and getting out in soft/disintegrated rock and getting out etc complete all as specified and directed.
Excavation over areas exceeding 1.5m deep but not exceeding 3.0m and getting out in soft/disintegrated rock complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/disintegrated rock complete all as specified and directed.
Removal of excavated soil/rock material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
PCC (1:4:8) Type D-2 (using 40mm graded stone aggregate) as in foundations for concrete manholes etc complete all as specified and directed.
Cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in coping of masonry wall including weathering, slightly rounded or chamfered angles and throating, necessary formwork as required and finishing the top surface of concrete even and smooth without using extra cement complete all as specified and directed.
Squared rubble walling, Jodhpur type regular coursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum dipression on face from sraight edge held against the dresses surface not exc 20mm and dressing of face beds and joints as specified to square rubble walling, jodhpur type, brought upto courses complete all as specified and directed.
15mm thick plaster in cement and mortar (1:6) on stone masonary surface or other than fair faces of brick work finished even & smooth without using extra cement complete all as specified and directed.
Preparation of newly plastered surfaces or unplastered surfase of walls and applying two coats of oil emulsion distemper over a coat of cement primer in different tints/shade as approved complete all as specified and directed.
Preparation of newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer in different tints as approved complete all as specified and directed.
Galvanized, corrugated mild steel sheet 0.60mm thick with two corrugation side lap, fixed with L-type or J-Type or cranked hook bolt and washers as in wall claddings etc. with grade of Zinc coating 275 complete all as specified & as directed.
Steel work in tubular pipes stanchions, purlins including special shaped, washer etc. including butt welded tuber cum forming to IS 1161-1979 grade st-240 complete all as specified and as directed.
Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work confirming to Fe-290 Grade E-165 complete all as specified and directed.
Prepariation of newly steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base of flooring finishing cement concrete surface fair and even complete all as specified and directed.
50mm thick Plain Cement Concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as floor, path, steps and plinth protection etc. finishing surface even and smooth without using extra cement complete all as specified and directed.
Hardcore of guage not exceeding 63mm deposited spread and levelled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified and directed.
Coloured Non Skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm (400x400mm) as in floors etc over 15mm thick in cement and mortar (1:6) bedding set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintel, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc complete all as specified and directed.
Mild steel TMT bars upto 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
MS TMT bar 5mm dia to 10mm for stirrups, bent to shape required, including cranking, binding spirraly for hoppijng for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Reinforced cement concrete (nominal mix) 1:2:4 type B1 using 20mm graded stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span and the like and complete all as specified and directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
Precast cement concrete nominal mix 1:2:4, type B1 (using 20mm graded stone aggregate) as in window or door cills, bressumers, steps quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in cement and mortar 1:6 complete all as specified and directed.
Factory made 30mm thick flush shutter, solid core construction, with block boards core and plywood face panels, commercial type on both sides (ISI Marked) fixed to chowkhats complete all as specified and directed.
Wood grain printed 2mm PVC sheet fixed or laid on to flush doors by using rubber based adhesive, fixed at site complete all as specified and directed.
100mm Butt hinges, heavy weight, cold rolled mild steel (ISI marked) fixed complete all as specified and directed.
150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
Aluminium handle 125mm long cast type, anodized complete all as specified and directed
250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30cm thick, watering, ramming/rolling and finishing to required size, shape, etc., not exceeding 1.5m high from base including supply of approved earth obtained from Air Force campus or from with Air Force station if approved including excavation and carrying to work site and including surface dressing not exceeding 15cm deep and cleaning away all grass, vegetation, saplings, shrubs, bush wood under growth roots, soft/loose soil etc and removing the same etc complete all as specified and as directed. Note : Quantity shall be calculated based on initial and final level reduce level and 10% deduction in quantity shall be applied for payment purpose.
HARD STANDING WORK Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/disintegrated rock complete all as specified and directed.
100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base of flooring finishing cement concrete surface fair and even complete all as specified and directed.
Sand filling 10mm thick under floor including watering, levelling and consolidation complete all as specified and directed.
Cement concrete work in pavement/hard-standing of flexural strength 40 Kg/per square centimetre in field using 400 Kg of cement per cubic metre, thickness of concrete 25cm or less complete all as specified and directed.
Supply only polyester, non circular/traingular, synthetic, fibres length 12mm long, with circum circle diametere 30-35 micron, designed for melting point of 240-260 degree C and having specific gravity of 1.34 to 1.40, complete all as specified and directed
Forming contraction dummy joint 65mm deep and 10mm wide (using diamond cutter) and filled with polyurethane sealant grade 'B' (minimum depth of sealant 12mm) complying with BS : 5212 and fixing 10mm dia polyurethane rod and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surfaces and to give a neat finish to the sealant in position as required complete all as per manufacturer's instructions complete all as specified and directed.
Forming construction joints 30mm deep and 10mm wide (using diamond cutter), providing polyurethane backup rod 12mm dia and sealant with polyurethane sealant grade 'B' (minimum depth of sealant 12mm) complying with BS : 5212, BS 4254 and EN 41875-2003 priming the sides minimum MAF+30% with ten year performance guaranteee and and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surfaces and to give a neat finish to the sealant as shown on drawing and removing the masking tape after sealant is applied complete all as specified and directed.
Finishing surface of concrete roads, pavements by brooming while concrete is green complete all as specified and directed.
High density polythene film (transparent colour) in single layer of 400 micron thickness of virgin quality (as per ASTM D 2103, IS-2508) laid with side and end overlaping not less than 300mm complete all as specified and directed
Preparation of newly floor surfaces and applying two coat of exterior emulsion paint (weather coat) over a coat of primer 1st quality in different tints/shades in sigma/camouflaging pattern as approved complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY WORK Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed.
Dry tibba sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Galvanized steel water tubing light grade of 40mm bore with & including all fittings complete, fixed with MS clamp of 25x3mm flat iron to wall/pole or laid in floor or under road etc, complete all as specified and directed.
Boring Hole/Drilling (Horizontally) under the road / pavement / hard standing with the help of trenchless and necessary machine for inserting Galvanised steel pipe of size 80mm not less than one metre below ground level complete all as specified and directed. Note : GI pipe shall be measured and paid for seperately in respective items.
INTERNAL ELECTRIC SUPPLY WORK Point wiring for one light point controlled by one way switch with 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade including 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated including suitable size module boxes for housing of modular switches, sockets, regulators complete all as specified & directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc and 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
All as per serial item No. 48.00 here-in-before but for one 3 pin 6 Amp socket outlet controlled by one 6 Amp switch on same board complete all as specified and directed.
All as per serial item No. 48.00 here-in-before but for one 3 pin 6 Amp socket outlet controlled by one 6 Amp switch on independent board complete all as specified and directed.
Point wiring for one 3 Pin, 16 Amps socket outlet controlled by one 16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated including suitable size module boxes for housing of modular switches, sockets, regulators complete all as specified and directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/ Anchor/ Formica including machine screws and washer etc for fixing switches sockets etc and 2.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
Switch piano, flush type, Single Pole, one way, 6 Amp, 240 Volts (ISI Marked) fixed complete all as specified and directed.
Switch piano, flush type, Single Pole, one way, 16 Amp, 240 Volts (ISI Marked) fixed complete all as specified and directed.
Socket outlet 2 in 1, 5 pin, 16 Amps, flush type, 240 Volts (ISI Marked) fixed complete all as specified and directed.
Socket outlet 2 in 1, 5 pin, 6 Amps, flush type, 240 Volts (ISI Marked) fixed complete all as specified and directed.
Ceiling rose surface bakelite with two or three terminal PVC/Polycarbonate, isolated body (ISI Marked), 240 volts complete all as specified and directed.
Decorative ultra slim square profile LED tube light fittings of capacity 18 watt LED 6500 K, basic all purpose surface and wall mounted LED batten with extruded polycarbonate housing & integrated electronic driver complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 8 way (2 + 6 ways), 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed.
MCB, Single Pole, 6 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles complete all as specified & directed.
MCB, SPN, 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles complete all as specified & directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No. 3 of SSR Part-I and connection to main switch board/Test point/ panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exceeding 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, Mild Steel Funnel with wire mesh, 20mm bore, GI pipe medium grade, 1.50 metre long for watering and 15mm bore, GI pipe light grade, 7.50 metre long for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:2:4) type B-1, using 20mm graded stone aggregate with angle iron 40x40x5mm frame 60mm thick RCC cover with 6mm steel bars 100mm centre to centre both ways complete all as specified & as directed. Note : (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
MARUDHARA CONSTRUCTION COMPANY
Leelashah Enterprises
M/S VISHNOI ENTERPRISES
M/s Shree Construction Company
M/s Fateh Enterprises
M/s Bhagwati Construction Company
M/s PRABHU DAN DETHA AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .