Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC Y 49 Y BLOCK HAUZ KHAS SOUTH WEST DELHI NEW DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | ₹4.1 Cr | L1 | Accepted-AOC Lowest contractor |
| 2 | L2₹5.0 Cr+₹87.0 L (21.1%)Rejected-Finance | ₹5.0 Cr+₹87.0 L (21.1%) | L2 | Rejected-Finance High rate in the contractor |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not responsive |
Tender Value
₹3.9 Cr
EMD Value
₹7.8 L
Closing Date
4 Oct 2021, 5:00 pmClosed
Executive Engineer (M)
CCS HAU, Hisr
Special repair renovation of Fletcher Bhawan at CCS HAU, Hisar (i.e. providing false ceiling and Granite stone flooring in circulation area of all floors, internal and external electrical work, Public health work, HVAC, Transformer, DG set etc.)
2021_HRY_188614_1
3252-C
Open Tender
Civil Works
Works
150 days
CCS HAU
Please refer Tender documents.
4 documents required · 4 mandatory
₹15,000
₹7.8 L
Yes
17 Nov 2021
17 Sept 2021
5 Oct 2021
17 Sept 2021
4 Oct 2021
17 Sept 2021
Amount
Civil work 1 to 33:- Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (HSR 5.70)
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: area beyond 3 sq. metres (HSR 5.29.2)
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 5.43.1 For thickness of tiles 10 mm to 25 mm (HSR 5.43.1)
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. (HSR 5.44)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platfonns, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.26.2 Granite of any colour and shade (HSR 8.26.2.2 ) Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (HSR 8.27.2) Granite work
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platfonn, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (HSR 8.28)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross 'T' of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main 'T' runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I (HSR 9.47.5)
Providing and Fixing 15 mm thick densifled tegular edged eco friendly light weight calcium silicate false celling tiles of approved texlure of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densifled edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixlures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main •r, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, noncombustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. (HSR 9.48)
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling (HSR 10.1)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, sqm Cat Eye or equivalent. (HSR 10.50.1)
Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. (HSR 10.51)
Providing and fixing 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with Second class teak wood (HSR 10.54.1)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)
Providing & Fixing decorative high pressure laminated sheet of plain/ wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick (HSR 12.12.2)
Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (HSR 30.19)
Flush pointing with cement mortar 1: 3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for prefixed flat tile bricks on top of mud phaska: With F.P.S. brick tiles (HSR 30.20.1)
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work (HSR 30.27.1)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work (HSR 30.28.1)
Regarding terracing of mud phaska covered with tiles or brick, in cement mortar by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1 :3 (1 cement : 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per direction of Engineer-in-Charge. (HSR 30.29)
Distempering with 1st quality acrylic distemper (ready made) having voe content less than 50 gm per litre. of approved manufacturer and of required shade and colour complete. as per manufacture r's specification. One or more coats on old work (HSR 30.34.1)
Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (One or more coat applied @ 0.90 litre/10 sqm). (HSR 30.37.2)
Applying epoxy mortar over leached, honey combed and spalled concrete surface and exposed steel reinforcement complete as per Technical Specification (HSR 35.21)
Providing and fixing High Pressure Laminated sheet (HPL) false ceiling at all height (Horizontal/vertical) consisting of following:- FRAME WORK Consisting of aluminium tube frame of size 25 mm x 38.10 mm x 2 mm @ 2 feet c/c fixed in position by suspenders of MS flat of size 1½" x 3/16" @ 4 feet c/c and steel rawal plug of approved make inclduing nuts & bolts CEILING WORK Consisting of HPL sheet of 6 mm thick of Green, Century and Sundek make fixed over aluminium tube frame properly by means of screws, nails etc., proper opending for light fittings and also petty items such as sealent, tape, rawal plugs, nails, screws etc., complete in all respect as per drawing & design. (NS)
Providing and fixing 12mm thick toughened glass (AIS, Modi Guard or Saint Gobion make) duly toughened by standardized plant, with required holes and cut outs as fixed panels at all height for glazing, fixed in position, complete in all respect as directed by Engineering-In-Charge. (NS)
Providing and fixing 12 mm thick toughened glass ( Saint Gobin make) for door shutter including making holes for fixing accessories such as handles, L-connectors and cut out for floor machine etc., complete in all respect as directed by the Engineer In Charge. (excluding cost of handles, connectors and floor machine). (NS)
Providing and fixing vitrified tiles of size 1200 mm x 600 mm wall tiles confirming to I.S.15622 (Thickness to be specified by the manufacturer) of approved make in all colours, shades as approved b y the Engineer-in- charge laid in any patterns as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment of matching shades, complete. (NS) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, JOHNSONS, RAK, ORIENT BELL & SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this. (NS)
Providing and fixing glass shutter accessories i.e. handle of Dorma make (Model XL-C3002A D type of size 300mm X 22mm) including cost of nuts, screws etc. complete in all respect. (NS)
Providing and fixing glass shutter accessories i.e. glass door package with lock (floor machine) of Dorma make (Model XL-C4001B) including cost of nuts, screws etc. complete in all respect. (NS)
Mirror polishing on marble work/Granite work/ Kota stone/ Terrazo Flooring or skirting etc work where ever required to give high gloss finish complete in all respect as directed by Engineer-in-charge. (NS)
Removing of existing damaged false ceiling with frame work (to be removed carefully)at all height and shifting the dismantlled material to maintenance store with a lead of 1 KM, complete in all respect as directed by the Engineer-In charge. (NS)
Cleaning at all height the stone surface and removing dirt, dust, bird sqm dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agent as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building/structure, complete in all respect as per direction of Engineer-in-charge (The rate is inclusive of all materials & labours involved) (NS)
Public health work 34 to 90:- Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded stone aggregate 20 mm nominal size)(HSR 6.1.2)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: (HSR 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)
Half brick masonry with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level. Cement mortar 1 :4 ( 1 cement :4 coarse sand) (HSR 7 .28.2)
12 mm cement plaster of mix 1 :6 (1 cement: 6 fine sand) (HSR 11.5.4)
12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT- I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS :12823, Grade 1, Type - II marked: (HSR 12.8.2)
Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm (HSR 12.98.2 )
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 150 x10 mm (HSR 12.99.4)
Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 100 mm (HSR 12.102.2)
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). (HSR 13.1.1 )
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 32 mm internal diameter (HSR 20.23.4)
40 mm internal diameter (HSR 20.23.5)
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 11.43 cm thick wall (HSR 20.26.1)
22.86 cm thick wall (HSR 20.26.2)
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside buildings, including cartage from divisional stores or nearest railway station to site of works. 32 mm internal diametre {HSR 20.31.4}
40 mm internal diametre {HSR 20.31.5}
Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site (HSR 20.36)
White vitreous chinaware Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISi Marked (HSR 22.1.9)
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia (HSR 22.14.2.1)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR 22.15)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (HSR 22.22.1)
Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (HSR 22.33)
Providing and fixing 8 mm dia C.P.S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (HSR 22.38)
Providing and fixing toilet paper holder C.P. brass (HSR 22.42.1)
Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (HSR 22.46)
Providing and fixing partitions for different type of urinals Large size 835mm x 355 mm White (HSR 22.50.1.2.1)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal outer dia Pipes (HSR 22.85.5)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes (HSR 22.86.2)
25 mm nominal outer dia Pipes (HSR 22.86.3)
32 mm nominal outer dia Pipes (HSR 22.86.4)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (HSR 22.103.3)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore (HSR 22.104.1)
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore (HSR 22.106.1)
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (HSR 22.107.1)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (HSR 22.108.1)
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (HSR 22.109)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (HSR 22.181)
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. C.P Brass Two Way (HSR 22.212.1.2)
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B 110 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.2)
90 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.3)
Supply of CPVC Union Couplings with brass internals of Prince/Supreme/Skipper make . (NS) (a) 32mm i/dia
(b) 40 mm i/dia
Supply of CPVC control valves of Prince/Supreme/Skipper make . (NS) (a) 32mm i/dia
(b) 40 mm i/dia
Supply and fixing of PVC floor traps (Heavy duty) of 90 mm o/dia outlet of Prince /Supreme/Skipper make, complete in all respect. (NS)
Supply and fixing of PVC gully traps (Heavy duty) of 100 mm dia size ( 4") with cover and frame of Prince/Supreme/skipper make complete in all respect. (NS)
Providing and fixing UPVC Elbows of Prince/Supreme/Skipper make. (NS) (a) 4" i/dia
(b) 3" i/dia
Providing and fixing UPVC Door juction of Prince/Supreme/Skipper make. (NS) (a) 4" x 4" x 4" i/dia
(b) 3" x 3" x 3" i/dia
Providing and fixing UPVC Cowls of Prince/Supreme/Skipper make. (NS) (a) 4" i/dia size
(b) 3" i/dia size
Providing and fixing Table top wash hand basin (Avior-R) Italian Collection of size 59.5 x 42 x 15.5 cm, star white, cat No. 91207 of Hindware make, complete in all respect. (NS)
Providing and fixing looking mirror 5.0 mm thikc mounted on asbestos sheet ground fixed in position by means of 4 Nos. C.P. brass screws and washers on rubber washers and rawl plugs embeded in wall or CP brass clamps with CP brass screws etc. complete in all respect. Make:- Saint Gobin/MODI/ATUL (NS) (a) Size 3'-0" x 2'-0"
(a) Size 6'-0" x 2'-0"
Providing and fixing sensor operated urinals (Alexa E-sense) italian Collection, of size 33 x 34.5 x 69 cm cat No. 96005, star white of Hindware Make, complete in all respect. (NS)
Providing and fixing sensor taps (Aquisense sensor tancet for wash basin with base flange) Model No. SNR-CHR-51011 of Jaquar Make, complete in all respect. (NS)
Electrical work 91 to 170:- Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. 25 mm dia (HSR 23.7.6.2)
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSR 23.8.10.1) 2 Modules
3 Modules (HSR 23.8.10.2)
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 23.8.11.1) 5 amp. 1 way switch
Blinking plate (HSR 23.8.11.10)
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. (HSR 23.22.4.1) 4-Way, SP&N (Horizontal)
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- MCB SP 6 to 32amp (HSR 23.22.5.1)
Control Cabling Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. (HSR 23.23.6.1) MS perforated cable tray painted with powder coating 100 X 50 X2mm
MS perforated cable tray painted with powder coating 200 X 50 X2mm (HSR 23.23.6.2)
MS perforated cable tray painted with powder coating 375 X 50 X2mm (HSR 23.23.6.3)
MS perforated cable tray painted with powder coating 600 X 50 X2mm (HSR 23.23.6.4)
Earthing with tinned copper earth plate 6D0mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. (HSR 24.1.4)
Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode (HSR 24.1.5)
Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.9)
Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.10)
S/E of recessed type <=42 watt full window glare free opal difffuse LED panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 5100 or above in cool day light (5600k to 6500k), Power factor >0.95, CRI (Ra) >80, LED lamp efficiency ≥140 lm/w, Average life >50000hours, complete with all accessories as required with connections. (Industrial) (NS) Make :- Havells , Bajaj
S/E of fancy pole 3 mtr. Long made out of cast iron base part and miled steel grooved pipe section and joined together by means of threaded joints alongwith a service window provided in the bottom part of the pole to accommodate a 6 amp. SP MCB and 30 amp. connector for mains connection. A cast aluminium embellishment shall be fitted to the grooved steel pole by grub screw fixing to enhance the decorative look of the pole. The pole shall be duly pre-treated by shot blasting process and painted in poly - urethane paint in approved colour shade having a minimum 300 salt spray hours quoting on the pole and should have minimum 90 micrones DFT. Pole Make: Twinkle, Homdec Lighting LED Specifications: LED should be ≤30 watt with cast aluminium housing diffuser translucent poly carbonate having quoting PU/Polyster LED should be ≤ 30 watt with separate driver placed integrally in luminaire housing. Driver should be of THD ≤ 10% and power factor above ≥0.95, External surge protection device of 10 KV should be provided. LED lumen should be ≥ 3600. The luminaire body shall be painted with exterior grade of poly - Urethane/polyster quoting in required colour shade. LED CCT should be 3000K ingress protection IP 65, power rating 230 Volts, AC 50 Hz.with suitable civil foundation etc. (NS) LED Make: Everlite/ MSL
S/E of Fazard Light 70 watt LED Type suitable for M.S. Powder coated white housing. Total system lumen of 70 watt LED should be 7000 or above in cool day light (3000k), Power factor >0.95, CRI (Ra) >80, LED lamp efficiency ≥110 lm/w, Average life >50000hours, complete with all accessories as required with connections. (NS)
S/E of Fazard Light 45 watt LED Type suitable for M.S. Powder coated white housing. Total system lumen of 45 watt LED should be 4950 or above in cool day light (3000k), Power factor >0.95, CRI (Ra) >80, LED lamp efficiency ≥110 lm/w, Average life >50000hours, complete with all accessories as required with connections. (NS)
Supply & Erection of Main Synchronizing L.T Panel outdoor type double door type having 01 No. ACB 1000A FP EDO 50KA for 500KVA DG Set , 01 No. ACB 800Amp FP EDO , 50KA for 320KVA DG Set , 01 No. ACB 1600A FP EDO for 1000KVA Transformer , 01 no. ACb for Outgoping Feeder FP 1600Amp EDO 50KA with complete set of Metering including R,Y,B LED's , Multifunction meters, CT's , control MCB , complete synchronizing panel with PLC and all control accessories to complete the system , 02 nos. MCCB FP 50KA 400Amp with ROM , 02 Nos. MCCB FP 50KA 250 Amp ROM switchgear Make L&T/ABB/Schneider with made out of 2mm thich CRCA sheet duly powder coated with siemens grey paint with base frame of 75*40*6mm M.S channel with 2000 Amp Copper busbar TPN with 1.0 sqmm current carring capacity with heat shrinkable seelve.Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993.i. IP 42 for indoor panels.ii. IP 55 for ODU panel. All MCCB’s shall be provided with operating mechanism for door interlock.All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.Providing cable clamps / supports within distribution boards cable alley.Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars.Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment. All meter shall be digital type. Current Transfomer shall be resin cast.All Panel Shall be BMS Compitable The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing complete in all respect. (NS) Make Newtech / M.K electric Services , Hisar.
Supply & Erection of Main L.T Panel outdoor type double door having 01 No. ACB 1600A FP EDO 50KA as incomer with complete set of Metering including R,Y,B LED's , Multifunction meters, CT's , control MCB , complete and all control accessories to complete the system ,01 No. ACB FP 800Amp EDO 50KA , 02 nos. MCCB FP 50KA 400Amp with ROM , 02 Nos. MCCB FP 50KA 250 Amp ROM , 02 nos. MCCB FP 35KA 200AMP WITH ROM switchgear Make L&T/ABB/Schneider with made out of 2mm thich CRCA sheet duly powder coated with siemens grey paint with base frame of 75*40*6mm M.S channel with 2000 Amp Copper busbar TPN with 1.0 sqmm current carring capacity with heat shrinkable seelve.Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993.i. IP 42 for indoor panels.ii. IP 55 for ODU panel. All MCCB’s shall be provided with operating mechanism for door interlock.All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.Providing cable clamps / supports within distribution boards cable alley.Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars.Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment. All meter shall be digital type. Current Transfomer shall be resin cast.All Panel Shall be BMS Compitable The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing complete in all respect. (NS) Make Newtech / M.K electric Services , Hisar.
Supply & Erection of Main UPS Panel having 01 No. MCCB FP200AMP 35KA AS INCOMER complete set of Metering including R,Y,B LED's , Multifunction meters, CT's , control MCB , complete and all control accessories to complete the system , 02 nos. MCCB FP 25ka KA 200Amp with ROM AS ups INCOMERS , 02 Nos. MCCB FP 25KA 200 Amp ROM FOR OUTGOING UPS , 01 nos. MCCB FP 25KA 200AMP WITH ROM for Outgoing of UPS switchgear Make L&T/ABB/Schneider with made out of 2mm thich CRCA sheet duly powder coated with siemens grey paint with base frame of 75*40*6mm M.S channel with 300 Amp Copper busbar TPN with 1.0 sqmm current carring capacity with heat shrinkable seelve.Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993.i. IP 42 for indoor panels.ii. IP 55 for ODU panel. All MCCB’s shall be provided with operating mechanism for door interlock.All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.Providing cable clamps / supports within distribution boards cable alley.Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars.Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment. All meter shall be digital type. Current Transfomer shall be resin cast.All Panel Shall be BMS Compitable The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing complete in all respect. (NS) Make Newtech / M.K electric Services , Hisar.
Supply & Erection of Main HVAC Panel outdoor type having 01 No. ACB 800AMP 50KA EDO AS INCOMER complete set of Metering including R,Y,B LED's , Multifunction meters, CT's , control MCB , complete and all control accessories to complete the system ,07 nos. MCCB FP 35KA 100Amp with ROM switchgear Make L&T/ABB/Schneider with made out of 2mm thich CRCA sheet duly powder coated with siemens grey paint with base frame of 75*40*6mm M.S channel with 1000 Amp Copper busbar TPN with 1.0 sqmm current carring capacity with heat shrinkable seelve.Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993.i. IP 42 for indoor panels.ii. IP 55 for ODU panel. All MCCB’s shall be provided with operating mechanism for door interlock.All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.Providing cable clamps / supports within distribution boards cable alley.Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars.Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment. All meter shall be digital type. Current Transfomer shall be resin cast.All Panel Shall be BMS Compitable The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing complete in all respect. (NS) Make Newtech / M.K electric Services , Hisar.
Supply & Erection of MCCB O/D type Enclosur for MCCB FP 25KA 100Amp complete set of Metering including R,Y,B LED's , , complete and made out of 2mm thick CRCA sheet duly powder coated with siemens grey paint with 100 Amp Copper busbar TPN with 1.0 sqmm current carring capacity with heat shrinkable seelve.Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993.i. IP 42 for indoor panels.ii. IP 55 for ODU panel. All MCCB’s shall be provided with operating mechanism for door interlock.All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.Providing cable clamps / supports within distribution boards cable alley.Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars.Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment. All meter shall be digital type. Current Transfomer shall be resin cast.All Panel Shall be BMS Compitable The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing complete in all respect. (NS) Make Newtech / M.K electric Services , Hisar.
Supply & laying of L.T 3.5 Core * 400 sqmm cable in sand & brick 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS ) CCI/Havells/ICL/Universal
Supply & laying of L.T 3.5 Core * 400 sqmm cable in Loose in existing trench , cable tray etc. 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS ) CCI/Havells/ICL/Universal
Supply & laying of L.T 3.5 Core * 240 sqmm cable in sand & brick 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS ) CCI/Havells/ICL/Universal
Supply & laying of L.T 3.5 Core * 240 sqmm cable in Loose in existing trench , cable tray etc. 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS ) CCI/Havells/ICL/Universal
Supply & laying of L.T 3.5 Core * 185 sqmm cable in sand & brick 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS) CCI/Havells/ICL/Universal
Supply & laying of L.T 3.5 Core * 185 sqmm cable in Loose in existing trench , cable tray etc. 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS ) CCI/Havells/ICL/Universal
Supply & laying of L.T 4Core * 50 sqmm cable in sand & brick 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect (NS) CCI/Havells/ICL/Universal
Supply & laying of L.T 4 Core * 50 sqmm cable in Loose in existing trench , cable tray etc. 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS )CCI/Havells/ICL/Universal (NS)
S/E of trenchless boring of road by HDD machine for laying required size of HDPE pipe 6" with socket reducer as per dia of cable at the end of pipe to closed the end of pipe to avoid entering of sand in pipe and all petty material required to complete the job as per entire satisfaction of the EIC. (NS)
S/E of XLPE(E) 1 KV HT Al. Conductor ar. Cable ISI mark laid in 1MV below ground level and sand bricks with all labour and material i/c digging and reflling complete (NS) CCI/Havells/ICL/Universal 50sqmm 3 core cable XLPE
S/E of XLPE(E) 1 KV HT Al. Conductor ar. Cable ISI mark laid in existing pipe/trenches/surface with all labour and material i/c digging and reflling of trench req. To complete the job. CCI/Havells/ICL/Universal (NS) 50sqmm 3 core cable XLPE
S/E of heat shrinkage type end termination kit outdoor type of suitable to accommodate 3 core 11 KV XLPE aluminum cable / ABC cable complete with all the kit contents including earth continuing connection along with 3 Nos crimpling type aluminum lugs of suitable capacity including making jointing etc. complete in all respect (NS) Suitable for 16 to 50 sqmm 3 core XLPE cable
Supply & laying of L.T 4 Core * 16 sqmm copper flexible unarmoured cable in Loose in existing trench , cable tray etc. including suitable Cu Lugs , Glands , connections complete in all respect (NS) CCI/Havells/ICL/Universal
Supply & laying of L.T 4Core * 10 sqmm cable in sand & brick 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect (NS) CCI/Havells/ICL/Universal
Supply & laying of L.T 4 Core * 10 sqmm cable in Loose in existing trench , cable tray etc. 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS ) CCI/Havells/ICL/Universal
S/E of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe.Havells , KEI , Polycab. (NS) Cable Size 1.5 sqmm (3/0.81)
Providing & fixing G.I. inerlocking fencing of size 3" x 3" or any other size made of 10 gauge wire fixed with RCC post by means of MS flat & amp; bolts / nuts (Items of MS flat and bolts / nuts shall be paid separately under HSR) including drilling holes in MS flatetc, complete in all respects as per architectural drawing and design. (NS)
S/E of coarse aggregate for concrete or stone ballast from quarried stone of size 53mm to 22.4mm.(NS)
Supply & Erection of HDPE pipe 75mm complete in all respect. (NS)
Supply & Erection of Angle Iron stand for Outdoor unit on roof for HVAC System with 50*50*6mm Angle complete with painting , grounting in all respect. With all petty matyerial required to complete the job. (NS)
HVAC SYSTEM EQUIPMENT (VRV) VARIABLE REFRIGERANT VOLUME/FLOW SYSTEM(With Heat Pump) Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . Make ;- Mitsubishi Heavy / O-General / Gree The bidder shall furnish de-areation values of VRF Outdoors at 43 Deg celcius mandatorily. VRV : 36 HP ODU
Ductable Type indoor unit - VRV SITC of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter fan section with low noise fan/dynamically balanced blower, multispeed motor , coil section with DX copper coil electronic expansion valve , corded remote control , outer cabinet , vibration isolators drain pan , other necessary supports etc. suitable for operation on single phase AC supply 230V +/- 10% , 50Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature.Make ;- Mitsubishi Heavy / O-General / Gree High Static ductable units ( minimum 110 pascal external static pressure ) 4 TR
4 Way Cassette Type indoor unit - VRV Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Make ;- Mitsubishi Heavy / O-General / Gree 2.4 TR
Wall mounted type indoor unit-VRF Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 3.1 0.6 TR each 18730 3.2 0.8 TR each 19312 3.3 1 TR each 19700 3.4 1.3 TR each 21176 3.5 1.45 TR each 21315 Make ;- Mitsubishi Heavy / O-General / Gree 0.6 TR
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required . Make : Mandev , Totaline , Mexflow , Parasmani 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller.(NS) Havells , KEI , Polycab
Providing and fixing and in position the following CPVC pipes for condensate drain duly insulated with kinny foam & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the indoor units upto the main header in the shaft dor vertical risers) (NS) Make:-Suprime, Polypack, Polycab, 25 mm dia
32 mm dia
AIR DISTRIBUTION SYSTEM Air Distribution Site Fabricated Duct Supply,Fabrication , Installation and testing of sheet metal ducts in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. (NS) Make:- Tata / Sail / Jindal 0.63mm (24 gauge) GSS
Supplying, installing, testing and balancing of aluminium supply/return air grills of various sizes. Each grill shall be with fixed horizontal front bar at Zero/15 Deg deflection through the collar and register. (NS) Aluminium Exh./return air grilles without damper of make as approved by Engineer-In-charge. Make :- Trox/RG Air System Control
Supplying, installing, testing and balancing of Aluminium Return air Diffuser without damper of make as approved by Engineer-In-charge. (NS)Make :- Trox/RG Air System Control
Supplying, installing, testing and balancing of Aluminium Volume control dampers for Slot Diffusers & supply air collar of Linear Grille of make as approved by Engineer-In-charge. (NS)Make :- Trox/RG Air System Control
INSULATION WORKS MECHANICAL INSULATION DUCT LINE ACOUSTIC TREATMENT Supply and Application of acoustic lining within the supply air duct Fiber Glass wool of 32kg./m³ density). as per specifications and drawings of make as approved by Engineer-In-charge. (NS) 10mm thick (For Duct) MAKE - INSU Sound BN (High performance and flexible versatile noise control application) 25mm thick (For Duct)
SITC of Thermal insulation material for Duct insulation shall be closed cell cross linked polyethylene foam. Thermal conductivity of the insulation material shall not exceed 0.032 W/moK at an average temperature of 25oC. Density of the material shall be 25-30 Kg/m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6: 1989 for fire propagation test and as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0.15ng/Pa.Sec.m. (NS) 9 MM Thick of make as approved by Engineer-In-charge. Make - K-Flex / Arma-Shel / Supreme 9 MM Thick
CABLING (POWER ) Power Cabling and Earthing: Supply, installation, testing & commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved) of make approved by Engineer In-charge. (NS)CCI/Havells/ICL/Universal Make:- KEI , Polycab, Finolex, RR Cable 4Cx10 Sqmm
4Cx16 Sqmm
Designing, Supply & erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 v. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT's) h) Metering set 60/5A/11 OV (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size I) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, De control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge Make : Kirloskar Green , Cummins . DG Set 320KVA
DG Set 500KVA
De-commissioning , Shifting , Re - commissioning of 800KVA transformer 11/0.433 KVA rating outdoor type with disconnection of existing HT/LT connections , earthing strips from transformer and shift within university premises and re erect with connectioning HT/Lt cables , jointing kits , earthing strips including correction of any harm during transportation , charging successfully complete in all respect entire cable network From transformer to main to L.T, panel fenced enclosure for transformer, and any other contingent thereto complete in all respect and directions of Engineer-in-charge. 800KVA
RCC FOUNDATIONS FOR 800kva Transformer Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per suitable design of manufacturer recommendations to provide levelled surface for placement of the transformer complete in all respects and as per directions of Engineer-in-charge. 800 KVA
2 X 100KVA - 200 KVA Solution Supply of 2 X 100 KVA/90 KW UPS with Battery Back-up : - UPS should have following specifications: True online double conversions, IGBT Rectifier & inverter based UPS. Latest Transformer Free Technology, Three phases Input/ three phase output with SMF batteries Suitable for 15 Min backup on Full load at 0.8 Average Load P.f. using 120 Ah X 40 Battery (ECV - upto 1.7V)with Each 100 KVA UPS, Input voltage range 340-478V at 100% load, 240-478 V @ 50% load. Online Mode Efficiency >= 96% for 50%, 75%, 100% Load and >95.5% for 25% Load ( Detailed Type Test report to be submitted to verify), Input power factor 0.99, input THDi less than 3% using latest Three Level IGBT Inverter Technology. Output THD is less than 3% for 100% Linear load. Crest factor 3:1, over load 125% for 10 min, 150% for 1 min. Overload Rating shall be available at 40 Degree C. Battery type should be Valve regulated lead-acid (VRLA) of make Exide/QUANTA/PANASONIC. Parallel communication port, RS232, USB, EPO and SNMP interface, BMS interface, Dust Filter at Air Inlet point are required. UPS should be provided with environment monitoring probe to measure temperature and humidity of UPS room thru SNMP software. LCD Display indicating all important parameters shall be available. SNMP software should be compatible to Microsoft windows XP, Windows Vista, Window 8, Window server 2003 R2, UPS software should be compatible to google chrome, Mozilla fire fox and Microsoft internet explorer. Battery open rack (top Covered), battery interlinks, battery MCCB in each Battery String, battery to UPS cable, parallel Communication Card, Parallel Cable as required should be provided with UPS systems. UPS Shall be able to work at 100 KVA / 100 KW @ 30 Degree C, 100 KVA / 80 KW @ 45 Deg C. High AC-AC Efficiency of 99% in ECO Mode / Energy Saving Mode. Energy Saving Mode should work in Parallel Operation also. UPS Approved Make : Nexus, ABB, GE, Gutor Battery Approved Make : Quanta / Exide / Panasonic Warranty : 2 Year UPS & Battery Both UPS shall be dispatched alongwith Factory test reports. NOTE :- UPS Shouldhave inbuilt Phase corrector function.
Mass International
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .