Design, supply, erection testing and commissioning of 25 KV, Single Phase, AC OHE works in connection with the following works : a.Provision of AT supply in connection with mobility improvement and capacity augmentation in Igatpuri - Asvali section (26.00 KM) by providing Automatic Signaling (ABS). b.Provision of AT supply in connection Automatic Block Signaling (ABS) in Asvali -Nasik Section. c.Provision of AT supply in connection with Automatic Block Signaling (ABS) in both UP & DN direction in Nasik-Kasbesukene Section.
BSL_ELECT_TRD_07_2026~CR
BSL_ELECT_TRD_07_2026
Open
Works - General
12 Months
Nashik, Maharashtra
₹0
₹2.5 L
10 Feb 2026
16 Jan 2026
27 Jan 2026
A-Provision of AT supply in connection with mobility improvement and
Preparation of design & drawing for overhead equipment
Cement concrete for foundation & plinth in other than hard soil & rock. (Foundation should be M-15 type as per IS-456, i.e ratio 1:2:4)
Supply of galvanized steel for structure
Erection of galvanized steel for structure
Supply of galvanized small parts steel (SPS)
Erection of galvanized small parts steel (SPS)
Supply of Copper Jumper wire (160 sq mm)
Supply of P.G.Clamp (1030-3) complete assembly
Erection of any type jumper assembly such as G Jumper, AT Jumper, Isolator Jumper etc
Supply of solid core suspension insulator assembly for AT supply
Erection of solid core suspension insulator assembly for AT supply (Excluding material)
Supply of 25 KV DO fuse switch assembly including insulators
Erection of 25 KV DO fuse switch assembly including insulators
Supply of 25 KV / 240 V, 25 KVA AT complete assembly as per RDSO specificatuion
Erection, testing & commissioning of 25 KV / 240 V, 25 KVA AT complete assembly
"Supply of LV box assembly for 25 KVA auxiliary transformer as per drawing."
"Erection of LV box assembly for 25 KVA auxiliary transformer as per drawing."
Supply of 100 mm dia. (OD) 'A' class GI pipe with GI flat clamp & required hardware
Laying of 100 mm dia. (OD) 'A' class GI pipe with GI flat clamp & required hardware
Supply of anti climbing device with GI barbed wire etc for AT mast.
Erection of anti climbing device with GI barbed wire etc for AT mast.
Supply of Retro reflective type Location number plates.
Erection of Retro reflective type Location number plates including clamps & nut bolt.
Supply of 25 KV Caution Board in electrified area as per RDSO Drawing.
Erection of 25 KV Caution Board in electrified area as per RDSO Drawing including clamps & nut bolts.
Supply of 40mm X 6mm Galvanized Traction Bond
Fabrication & fixing of 40mm X 6mm Galvanized Traction Bond
Supply of 50mm X 6mm Galvanized Traction Bond
Fabrication & fixing of 50mm X 6mm Galvanized Traction Bond
Supply of single earth electrode
Erection of single earth electrode
"Transportation, Trenching, and Laying of LT/HT various size of PVC/XPLE cables/across along the Railway track"
Supply of RCC warning cover as per specification.
Laying of RCC warning cover as per specification.
Supply of cast iron cable marker as per drawing.
Erection of cast iron cable marker as per drawing.
Supply of 150 mm size RCC hume pipe along with collar / coupler etc.
Laying of 150 mm size RCC hume pipe along with collar / coupler etc.
Supply of DWC HDPE Pipe with one snap fit coupler and O ring fire resistant, antirodent of size 150 mm dia.
Horizontal direction drilling/boring without damage of surface road /track using Auger Machine (HDD machine). The bore shall be upto 200 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. This include insertion of different dia DWC-HDPE pipe
Laying of 2 X 185 sq. mm. Al. armoured cable through provided pipe on wall / structure
Laying of 2 X 185 sq. mm. Al. armoured cable by cleating on wall.
Supply of junction box assembly for 25 KVA AT Supply as per drawing.
Erection of junction box assembly for 25 KVA AT Supply as per drawing.
Supply of termination box assembly for 25 KVA AT Supply as per drawing.
Erection of terminationn box assembly for 25 KVA AT Supply as per drawing.
Supply of Control & distribution Panel with Auto change over switch, 155 Amp capacity (3 source type) for CLS supply, suitable for 25 KVA 'AT', as per RDSO specification latest.
Erection, testing & commissioning of Control & distribution Panel with Auto change over switch, 155 Amp capacity (3 source type) for CLS supply, suitable for 25 KVA 'AT', as per RDSO specification
Dismantling of LV box assembly
Dismantling of junction box assembly
Dismantling of termination box assembly
Dismantling of Control & Distribution Panel with auto change over switch for CLS supply complete with box including disconnection of cable connection.
Removal of Al.armoured cable cleated on wall.
Dismantling of 10 KVA/25 KVA/50 KVA 'AT' complete with all accessories with DO fuse, jumper
Dismantling OHE structures by cutting & transporting to Railway depot including loading and unloading.
B-Provision of AT supply in connection Automatic Block Signaling (ABS)
Preparation of design & drawing for overhead equipment
Cement concrete for foundation & plinth in other than hard soil & rock. (Foundation should be M-15 type as per IS-456, i.e ratio 1:2:4)
Supply of galvanized steel for structure
Erection of galvanized steel for structure
Supply of galvanized small parts steel (SPS)
Erection of galvanized small parts steel (SPS)
Supply of Copper Jumper wire (160 sq mm)
Supply of P.G.Clamp (1030-3) complete assembly
Erection of any type jumper assembly such as G Jumper, AT Jumper, Isolator Jumper etc
Supply of solid core suspension insulator assembly for AT supply
Erection of solid core suspension insulator assembly for AT supply (Excluding material)
Supply of 25 KV DO fuse switch assembly including insulators
Erection of 25 KV DO fuse switch assembly including insulators
Supply of 25 KV / 240 V, 25 KVA AT complete assembly as per RDSO specificatuion
Erection, testing & commissioning of 25 KV / 240 V, 25 KVA AT complete assembly
"Supply of LV box assembly for 25 KVA auxiliary transformer as per drawing."
"Erection of LV box assembly for 25 KVA auxiliary transformer as per drawing."
Supply of 100 mm dia. (OD) 'A' class GI pipe with GI flat clamp & required hardware
Laying of 100 mm dia. (OD) 'A' class GI pipe with GI flat clamp & required hardware
Supply of anti climbing device with GI barbed wire etc for AT mast.
Erection of anti climbing device with GI barbed wire etc for AT mast.
Supply of Retro reflective type Location number plates.
Erection of Retro reflective type Location number plates including clamps & nut bolt.
Supply of 25 KV Caution Board in electrified area as per RDSO Drawing.
Erection of 25 KV Caution Board in electrified area as per RDSO Drawing including clamps & nut bolts.
Supply of 40mm X 6mm Galvanized Traction Bond
Fabrication & fixing of 40mm X 6mm Galvanized Traction Bond
Supply of 50mm X 6mm Galvanized Traction Bond
Fabrication & fixing of 50mm X 6mm Galvanized Traction Bond
Supply of single earth electrode
Erection of single earth electrode
"Transportation, Trenching, and Laying of LT/HT various size of PVC/XPLE cables/across along the Railway track"
Supply of RCC warning cover as per specification.
Laying of RCC warning cover as per specification.
Supply of cast iron cable marker as per drawing.
Erection of cast iron cable marker as per drawing.
Supply of 150 mm size RCC hume pipe along with collar / coupler etc.
Laying of 150 mm size RCC hume pipe along with collar / coupler etc.
Supply of DWC HDPE Pipe with one snap fit coupler and O ring fire resistant, antirodent of size 150 mm dia.
Horizontal direction drilling/boring without damage of surface road /track using Auger Machine (HDD machine). The bore shall be upto 200 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. This include insertion of different dia DWC-HDPE pipe
Laying of 2 X 185 sq. mm. Al. armoured cable through provided pipe on wall / structure
Laying of 2 X 185 sq. mm. Al. armoured cable by cleating on wall.
Supply of junction box assembly for 25 KVA AT Supply as per drawing.
Erection of junction box assembly for 25 KVA AT Supply as per drawing.
Supply of termination box assembly for 25 KVA AT Supply as per drawing.
Erection of terminationn box assembly for 25 KVA AT Supply as per drawing.
Supply of Control & distribution Panel with Auto change over switch, 155 Amp capacity (3 source type) for CLS supply, suitable for 25 KVA 'AT', as per RDSO specification latest.
Erection, testing & commissioning of Control & distribution Panel with Auto change over switch, 155 Amp capacity (3 source type) for CLS supply, suitable for 25 KVA 'AT', as per RDSO specification
Dismantling of LV box assembly
Dismantling of junction box assembly
Dismantling of termination box assembly
Dismantling of Control & Distribution Panel with auto change over switch for CLS supply complete with box including disconnection of cable connection.
Removal of Al.armoured cable cleated on wall.
Dismantling of 10 KVA/25 KVA/50 KVA 'AT' complete with all accessories with DO fuse, jumper
Dismantling OHE structures by cutting & transporting to Railway depot including loading and unloading.
C-provision of AT supply in connection Automatic Block Signaling(ABS)
Preparation of design & drawing for overhead equipment
Cement concrete for foundation & plinth in other than hard soil & rock. (Foundation should be M-15 type as per IS-456, i.e ratio 1:2:4)
Supply of galvanized steel for structure
Erection of galvanized steel for structure
Supply of galvanized small parts steel (SPS)
Erection of galvanized small parts steel (SPS)
Supply of Copper Jumper wire (160 sq mm)
Supply of P.G.Clamp (1030-3) complete assembly
Erection of any type jumper assembly such as G Jumper, AT Jumper, Isolator Jumper etc
Supply of solid core suspension insulator assembly for AT supply
Erection of solid core suspension insulator assembly for AT supply (Excluding material)
Supply of 25 KV DO fuse switch assembly including insulators
Erection of 25 KV DO fuse switch assembly including insulators
Supply of 25 KV / 240 V, 25 KVA AT complete assembly as per RDSO specificatuion
Erection, testing & commissioning of 25 KV / 240 V, 25 KVA AT complete assembly
"Supply of LV box assembly for 25 KVA auxiliary transformer as per drawing."
"Erection of LV box assembly for 25 KVA auxiliary transformer as per drawing."
Supply of 100 mm dia. (OD) 'A' class GI pipe with GI flat clamp & required hardware
Laying of 100 mm dia. (OD) 'A' class GI pipe with GI flat clamp & required hardware
Supply of anti climbing device with GI barbed wire etc for AT mast.
Erection of anti climbing device with GI barbed wire etc for AT mast.
Supply of Retro reflective type Location number plates.
Erection of Retro reflective type Location number plates including clamps & nut bolt.
Supply of 25 KV Caution Board in electrified area as per RDSO Drawing.
Erection of 25 KV Caution Board in electrified area as per RDSO Drawing including clamps & nut bolts.
Supply of 40mm X 6mm Galvanized Traction Bond
Fabrication & fixing of 40mm X 6mm Galvanized Traction Bond
Supply of 50mm X 6mm Galvanized Traction Bond
Fabrication & fixing of 50mm X 6mm Galvanized Traction Bond
Supply of single earth electrode
Erection of single earth electrode
"Transportation, Trenching, and Laying of LT/HT various size of PVC/XPLE cables/across along the Railway track"
Supply of RCC warning cover as per specification.
Laying of RCC warning cover as per specification.
Supply of cast iron cable marker as per drawing.
Erection of cast iron cable marker as per drawing.
Supply of 150 mm size RCC hume pipe along with collar / coupler etc.
Laying of 150 mm size RCC hume pipe along with collar / coupler etc.
Supply of DWC HDPE Pipe with one snap fit coupler and O ring fire resistant, antirodent of size 150 mm dia.
Horizontal direction drilling/boring without damage of surface road /track using Auger Machine (HDD machine). The bore shall be upto 200 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. This include insertion of different dia DWC-HDPE pipe
Laying of 2 X 185 sq. mm. Al. armoured cable through provided pipe on wall / structure
Laying of 2 X 185 sq. mm. Al. armoured cable by cleating on wall.
Supply of junction box assembly for 25 KVA AT Supply as per drawing.
Erection of junction box assembly for 25 KVA AT Supply as per drawing.
Supply of termination box assembly for 25 KVA AT Supply as per drawing.
Erection of terminationn box assembly for 25 KVA AT Supply as per drawing.
Supply of Control & distribution Panel with Auto change over switch, 155 Amp capacity (3 source type) for CLS supply, suitable for 25 KVA 'AT', as per RDSO specification latest.
Erection, testing & commissioning of Control & distribution Panel with Auto change over switch, 155 Amp capacity (3 source type) for CLS supply, suitable for 25 KVA 'AT', as per RDSO specification
Dismantling of LV box assembly
Dismantling of junction box assembly
Dismantling of termination box assembly
Dismantling of Control & Distribution Panel with auto change over switch for CLS supply complete with box including disconnection of cable connection.
Removal of Al.armoured cable cleated on wall.
Dismantling of 10 KVA/25 KVA/50 KVA 'AT' complete with all accessories with DO fuse, jumper
Dismantling OHE structures by cutting & transporting to Railway depot including loading and unloading.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .