Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.5 L+₹2.3 L (5.71%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹44.0 L+₹3.7 L (9.26%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹46.4 L+₹6.2 L (15.4%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹47.4 L+₹7.2 L (17.9%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹47.6 L
EMD Value
₹95,200
Closing Date
23 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School Mhow (MP) - 453441
SPL REPAIR TO BLDG NO SM 259 AT YO 180 VIKRAM BATRA BLOCK ACCN AT THE INF SCHOOL UNDER GE MIS MHOW
2025_MES_710411_1
8791/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
150 days
GARRISON ENGINEER (MIS)
All as per Tender document
8 documents required · 8 mandatory
₹500
GE (MIS) Mhow
₹95,200
Yes
11 Jul 2025
26 May 2025
25 Jun 2025
26 May 2025
23 Jun 2025
9 Jun 2025
Amount
Demolition of brick work built in cement mortar including all quoins arches pillars etc complete all as specified and directed. Note : All demolished items shall be removed from Defence land as per dirns of Engr-in Charge.
M & L for Brick work with usingflyash brick modular size , straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for brick work with using flyash bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar (CM) 1:4 complete all as specified and directed.
Taking down cement plaster on brick wall /ceiling built in cement mortar including raking out joints , hacking for key scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar (1:6) on faces of brick work and finished the surface even and smooth without using extra cement complete as specified and directed
M&L for rendering 15 mm thick on fair faces of concrete/brick exterior surfaces in cement mortar 1:4 mixed with WPC as per manufacturer instruction, finished even and smooth without using extra cement complete as specified and directed. Note :- WPC shall be measured and paid for separately.
Supply only liquid water proofing chemical (used 200ml per bag of cement) ISI marked complete all as specified and directed.
M & L for rendering 10mm thick in cement mortar (1:3) as in ceiling on fair faces of brick work and finished the surface fair and even without using extra cement complete as specified and directed
M&L for applying 1mm thick wall care putty on wall on internal old/new wall/ceiling surfaces as per manufacture instruction complete all as specified and as directed
M & L for preparation of newly plastered surfaces of walls and apply two coats of oil bound distemper over a coat of primer white or tinted complete as specified and directed
M&L for preparation of new decorated surfaces of wall and apply two coats of Anti fungal weather coat acrylic emulsion paint or weather coat emulsion over and including a coat of exterior grade wall primer paint and one coat of 1 to 1.5mm thick white cement based putty complete all as specified and directed Note : (a) Each stage i.e preparation of surfaces, application of putty, application of primer,application of first coat and application of second coat will be got passed from Engr-in-Charge
M&L for applying three coats of white washing on new plastered surfaces of ceiling including preparation complete all as specified and as directed.
M&L for complete removal of existing treatment on old decorated surface of wall and applying two coat of oil emulsion distemper white/coloured over and including 1.5 to 2mm thick wall care based putty complete as specified and directed
M&L for complete removal treatment on old/new decorated surface of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and 1.5 to 2mm thick wall care putty complete all as specified and directed. Note : (a) Each stage i.e preparation of surfaces, application of putty, application of primer,application of first coat and application of second coat will be got passed from Engr-in-Charge
M & L for preparing old decorated plaster or un-plastered surfaces of ceiling and applying two coat of white wash complete all as specified and as directed.
M & L for providing complete water proofing treatment to sunken floor surfaces of RCC slab by the following specifications including taking down and cleaning of old surface as specified and directed :- (a) Provide PCC (1:1.5:3) type A0 with using 12.5mm graded stone aggregate in slope of average thickness 50mm mixed with and including liquid water proofing compound as approved by GE. (b) M&L rendering 15mm thick in CM 1:3 mixed with & including water proofing compound on sides of (Vertical surface) sunken floor slab. (c) Apply first coats fastflex with a stiff nylon brush and leave 4 to 6hrs for dry. (d) After 4 to 6hrs completion of first coat apply second coat the direction of 90 degree to the first coat and leave 4 to 6hrs for dry. (e) After 4 to 6hrs completion of second coat apply third coat the direction of 90 degree to the second coat and allow to dry for 4 to 6hrs. Note: NOTE:- Application of water proofing treatment shall be executed through expert team of manufacturers or their authorised applicator.
M&L for Plain cement concrete 1:5:10, type E-2 (using 40mm graded brick aggregate) as in filling of sunken portion complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate mixing with WPC levelling course in floor etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and directed.
M&L for light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
M&L for light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.06 sqm,vertical surfaces as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering incement mortar (CM) 1:4 complete all as specified and as directed.
M&L for Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L for glazed ceramic coloured wall tiles (textured and design as required) in vertical surface as in skirting/dado 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed.
Taking down chowkats or frames not exc. 1.5 sq.m. each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sq.m. n.exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
S&F Plain, solid, straight 2nd class hard wood frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
Taking down shutters exc 1.00 sqm but n.exc 2.00 Sqm each complete all as specified and directed.
Taking down door shutter from frame exc 1 Sqm but not exc 2 Sqm each and refixing the shutter in the same opening after easing and adjusting complete all as specified and directed.
S&G 2nd class hard wood 35 mm thick Plain , framed panelled factory made shutters (any number of panels), with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats complete all as speciifed and directed.
S&F 30 mm thick Flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed.
S & F 2nd class hard wood 35 mm thick Glazed and skeleton factory made shutters, open rebated and prepared to receive glass , gauze, etc, (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) fitted to chowkats complete all as specified and directed. Note : Wire mesh shall be measured and paid separately.
S & F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F powder coated aluminium door seal 30mm wide and length as per requirement of site including dust/insect arrestor complete all as specified and directed.
Cutting holes in brick/block walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required exc half brick n.exc one brick factory made complete all as specified and directed.
S & F mild steel bands, straps, support or stays for rainwater ventilating pipes including bolts if required, hook and eye, Hold fasts wall ties hooks for hanging fans, plain angle etc complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel over coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wooden surface applying one coat of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified and directed.
S&F powder coated aluminium sliding glazed windows with three track shutter sliding (two shutters glazed and one shutter wire mesh) with following specification and making good the adjacent side of jombs of windows by plastering in CM 1: 3 even and smooth complete all as specified and as directed by Engr-in-charge. (i) Windows frame of cross section 101mm x 44mm x 1.5mm thick. (Min) (ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm x1.1mm thick.(Min) (iii) Sliding shutter frame of cross section 40 x 18 x 1mm thick.(Min) (iv) 4 mm thick glass superior quality.(Min) (v) IDPE Rubber guasket for fixing of glass. (vi) Locking cleats per shutter -01 Nos.(Min) (vii) Sliding rollers per shutter - 02 Nos.(Min) (viii) Stainless steel wire cloth 0.30mm nominal dia of wire and average width of aperture 1.40mm for shutters 01 Nos. (Ix) fixing screw for frame with wall per windows- 08 Nos.
S&F MS Framed work such as grills,gratings, etc. with ends of barsshouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F powder coated aluminium ventilator cross section conforming to IS 63.5x38.10x1.5mm consisting of two partions upper portion shall have louvers with 3mm thick pin headed glass and aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56m fixed with aluminium beads and securing on outer face of frame and lower portion of ventilation shall be fixed with 3mm thick pin headed glass with IDPE rubber gasket including aluminium beads, including preparation of jombs all around in CM 1:3 finishing even and smooth complete all as specified and directed.
M&L for preparation of old steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of synthetic enamel paint.
S & F stainless steel butt hinges 100 mm long complete all as specified and directed.
S&F 150 mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm size aluminium anodized handle complete all as specified and directed.
S & F in repairs aluminium floor door stoppers double legged length 140mm with hard drawn steel spring fitted in floor complete all as specified and directed.
S&F 300 mm long aluminium alloy anodized sliding door bolts with Hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F mild steel 300mm ordinary rat tail rod springs including roller and roller plate complete all as specified and directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white colour (excluding fixing bolts, flushing cistern & flush pipe) including P or S Trap) and plastic water closet seat, white colour, closed pattern with flat bottom, & cover & mild steel CP or aluminised hinging device complete all as specified and directed.
S & F in repair wash hand basins, white colour,vitreous china,of size 550x400mm (flat back, or angle back type) including cutting for and pinning in ends of brackets or erecting stand inclusive of waste pipe, CP waste coupling etc complete all as specified and directed.
S & F in repair 32 mm bore low density polythene pipe (LDPE) of pressure rating 6 kgf / Sqcm for WHB and sink complete all as specified and directed.
S&F 15 mm dia bore basin mixture brass chromium plated with capstan heads screwed down high pressure with or without letter ‘HOT’ or ‘COLD’ with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair chromium plated brass wall mixer 3-in-1 fancy type with provison for both hand shower and overhead shower complete with wall flange (without hand & over head Shower screwd down for15 mm GI bore pipe complete all as specifed and directed.
S & F in repair over head shower with arm & flnge of chromium plated with or without swivel joints, any size, including fixing to 15mm dia steel pipe for required length or union complete all as specified and directed.
S & F in repair 15 mm bore bib taps long body, with wall flnge chromium plated cast copper alloy long body , screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S & F in repair 10 ltrs capacity PVC flushing cistern, low or high level, with inlet, ball valve, syphonic action type, float and handle, PVC Flush pipe , pull or push type including brackets complete as fixed complete all as specified and directed.
S & F in repair brass chromium plated angle cock 15 mm dia screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair fancy type chromium plated two way bib cock of 15mm bore two way bib cock screwed for iron pipe or brass ferrule etc complete all as specified and as directed.
S & F in repairs Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed 20mm dia complete all as specified and directed.
S & F in repair Bidet spray (Health faucet) with 1.20meter tube and holder, complete all as specified and directed.
S & F in repair CP Toilet paper holder complete all as specified and directed by Engineer-in-Charge.
S&F in repair soap dish (ovel) type Stainless Steel chromium plated of size not less than 50mm dia complete all as specified and directed.
S & F in repair corner shelf of 300 mm size with ABS brackets complete all as directed and specified.
S&F in repairs shelf glass assembly consisting of 5.5mm thick sheet glass,shelf 120mm wide with CP bracket guard and railing 600mm long complete all as specified and directed
S & F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and directed
S&F in repair Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed.
S & F in repair brass chromium plated towel rail 20 mm outer dia Bracket type, 60 cm long between flanges with and including chromium plated brass screws and wooden / plastic cleats, complete all as specified and directed.
S&F in repairs 25 mm dia stainless steel curtain rod incl S/S decorative brackets, at ends with arrangements as approved by GE complete all as specified and directed
Taking down steel tubing 15mm bore and connections complete all as specified and directed by Engineer - in – Charge.
S & F 20mm dia CPVC Pipe SDR 11 & plain CPVC SDR 11 all fittings such as Tee, Bend, Elbow, Socket Reducer etc incl jointing and testing concealed to walls and ceilings or laid in floors, complete all as specified and directed.
S & F of CPVC Male/Female Brass Threaded Adaptor (MTA/ MBTA or FTA/FBTA) for 20 mm dia pipe complete all as specified and directed.
Taking down steel tubing 25mm bore and connection complete all as specified and directed by Engineer - in - Charge.
S & F 25mm dia GI Pipe including jointing and testing galvanised steel water tubing medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in CM(1:3) to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in Stone/ brick walls complete all as specified and directed.
S&F 40mm dia GI Tubing as in spout pipe of medium grade including cutting in any length as required and fixed to wall & floor etc complete all as specified and directed.
S&F in repairs PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repairs PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm dia complete all as specified and directed.
S&F PVC junction single (single T) 110mm dia equal or unequal with access door complete all as specified and directed.
S&F PVC junction single (single T) 75mm dia equal or unequal with access door complete all as specified and directed.
S&F 100mm stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F 75mm stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
M&L in repair PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement
M&L in repair PVC (SWR) gully trap 125/110 mm, setting & jointing with solvent cement complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n exc. 15cm thickness (below or above ground level) complete all as specified and directed. Note : All demolished items shall be removed from Defence land as per dirns of Engr-in Charge.
M & L for chequered cement concrete tiles (glossy finish) 40 cm x 40 cm x 25 mm thick set ,jointed and pointed in neat cement slurry in floors with grey cement and no pigment laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) and necessary PCC coping ,type C1 1:3:6 including dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection including making joint at every 3 mtr interval and at corner and filled with mixture of bitumen and sand and finished even and smooth with extra cement and laid in alternate bays complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fittings complete etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc. complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC FRLS concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with Gl sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches and blank plates, Including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following:-
(a) One light/fan/bell point controlled by one, one way switch 5 Amps
(b) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
All as per item No 90.00 above but using 2.5 sq. mm single core copper conductor cable of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sq. mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S & F Modular Switch, single pole, one way, and 5/6 Amp single module complete all as specified and directed
S & F Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module complete all as specified and directed
S & F Modular Switch, single pole, one way, and 15/16 Amp single module complete all as specified and directed
S & F Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module complete all as specified and directed
S & F Modular Bell push modular 6 Amps single module complete all as specified and directed
S & F Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed.
S & F Celling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and as directed.
Supply, installation, commissioning and testing of factory made Meter box for single phase meter 217mm x 253mm x 115mm, made out of IP 65 thermo plastic PS polystyrene weather proof with multi level knock out for cable glands in different sizes at bottom of the box, rain water proof, wall thickness 3 mm including complete internal wiring with 2.5 sqmm copper wire complete all as specified and as directed by Engineer-in-Charge. Make: Hensel/L&T/Havells / Make as per Particular specification
S & F energy efficient exhaust fan of PVC body 225/230 mm sweep type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall or fixing in aluminium fabricated windows including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. Note: Cost of suitable opening wall for fixing exhaust fan is deemed to be included in the quoted rate.
RK CONSTRUCTION (BID ID -3324759)
Chitragupta Construction (BID ID -3334219)
M/S UnitedConstruction (BID ID -3333746)
SATHI ENTERPRISES (BID ID -3333123)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .