Loading…
Loading…
Tender Value
₹32.6 L
EMD Value
₹65,300
Closing Date
21 Jul 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
M AND P
3 conditions · 2 needing a document upload
I/we have read the General Conditions of Contract (GCC) with all Correction Slips up to date, NIT, Tender Document, Corrigendum (if issued) carefully and submitted all the relevant documents as per the requirement of Tender Document. I/we understand that if I/we failed to submit any required document, my bid will be liable for summarily rejection.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor has to submit a copy of valid Electrical Contractor License for carrying out installation work of voltage class involved, issued by any State/Central Government along with a supervisor competency certificate as per Regulation 29 of the Central Electricity Authority (Measure relating to Safety and Electric Supply) Regulation 2010 or latest / as per Rules 45 of the Indian Electricity Rules 1956 along with the tender documents, failing which the offer is liable to be rejected.
Electrification arrangement for construction of office block G+2.
RCF-EL-MTC-89-ET-26-27
RCF-EL-MTC-89-ET-26-27
Open
Works - General
90 Days
Kapurthala, Punjab
₹0
₹65,300
21 Jul 2026
29 Jun 2026
7 Jul 2026
45 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 32,63,323 | ||
| — | 500.00 | — | — | ||
| Supply ,wiring ,testing & commissioning of L/F Point wiring with 2x2.5Sqmm 1100 volt grade multistranded Copper wire conforming to IS 694-2010 and 1 Sqmm PVC insulated copper wire green colour as earth wire to be laid in existing conduit.Also Supply , fixing ,testing and commissioning of modular face plate and grid plate as required ar site 5/6amp 1 way modular switch on suitable GI recess/PVC box/flush wall box .All points to be connected with earth wire.Also keep loop to 150 mm long on every end point circuit and point wiring.as per Explanatory Note-1 Make: CPL,SSk, L&T,Anchor,Havels, Hager, Schneider ,KEI,Rallison. | — | — | — | 2,25,000 | |
| — | 85.00 | — | — | ||
| Supply ,wiring ,testing ,fixing and commissioning of 6 pin 16 Amp. plug point wiring with 2x4Sqmm 1100volt grade multistranded Copper wire conforming to IS 694-2010 and 1 Sqmm PVC insulated copper wire green colour as earth wire to be laid in existing conduit. Also Supply,fixing , testing and commissioning of 16amp.240volt switch socket modular type with modular face plate and grid plate ISI marked to be fixed on suitable GI recess /PVC BOX /Flush wall box. 10amp 1-way modular switch on suitable GI recess/PVC box/flush wall box. points to be connected with earth wire.Also keep loop to 150 mm long on every end point circuit and point wiring. as per Explanatory Note-2 Make: CPL,SSk, L&T,Anchor, Legrand,Havels, Hager, Schneider, KEI,Rallison only. | — | — | — | 41,650 | |
| — | 200.00 | — | — | ||
| Supply ,wiring ,testing ,fixing and commissioning of 6 Amp. plug point wiring with 2x2.5Sqmm 1100volt grade multistranded Copper wire conforming to IS 694-2010 from SPN DB with 2x4 sqmm copper wire conforming to IS 694-2010and 1 Sqmm PVC insulated copper wire green colour as earth wire to be laid in existing conduit. Also Supply, fixing, testing and commissioning of 5 pin socket and 6amp.240volt switch socket modular type with modular face plate and grid plate ISI marked to be fixed on suitable GI recess /PVC BOX /Flush wall box. 6amp 1 way switch on suitable GI recess/PVC box/flush wall box.All points to be connected with earth wire.Also keep loop to 150 mm long on every end point circuit and point wiring. as per Explanatory Note-3 Make: CPL, SSk,L&T, Anchor, Havells. Standard, Hager, | — | — | — | 80,000 | |
| — | 75.00 | — | — | ||
| Supply, fixing, testing and commissioning of pre fabricated 6 way SPN distribution board of sheet enclosed with DP MCB 32Amp.2 nos.,SP MCB 16A-02 nos .as per Explanatory Note-4 Make: L&T,Havells ,Legrand, SSk,Anchor,C&S,Siemens,Hager, ABB,Schneider. | — | — | — | 2,25,000 | |
| — | 2000.00 | — | — | ||
| Supply & laying of PVC conduit pipe (Medium Mechenical Strength) /casing Capping of 25mm dia, ISI marked in/on wall including bends, junction boxes and MS saddles etc and repair the same in original shape including white wash/ distemper after laying of pipe. as per Explanatory Note-5 Make should be ISI Marked Anchor ,Finolex only. | — | — | — | 1,20,000 | |
| — | 2500.00 | — | — | ||
| Supply, laying wiring, testing and commissioning of Circuit wiring with 2x4sq.mm multi stranded copper conductor wire, conforming to IS -694-2010, with 1sqmm green multi stranded copper wire as earth in existing conduit 25 mm dia. as per Explanatory Note-6 Make: Polycab, L&T,RR kable, KEI, Rallison, Havells,ECKO , Finolex. | — | — | — | 2,00,000 | |
| — | 120.00 | — | — | ||
| Supply ,fixing ,testing and commissioning of oscillating ,multi speed 400 mm sweep Bracket fan of make Crompton Greaves including connection etc. as per Explanatory Note-7 Make of Khaitan,Usha,Crompton,Havells,Orient. | — | — | — | 2,46,000 | |
| — | 150.00 | — | — | ||
| Supply ,fixing, testing and commissioning of 4 ft long,18/20 watt LED type light fitting ,light appearance white suitable for 230 volt 50HZ supply as per. Make of Bajaj, Surya, Philips, Goldwyn, Helonix,GE Crompton, Havells, Orient, Bajaj. | — | — | — | 30,000 | |
| — | 70.00 | — | — | ||
| Supply,Fixing ,testing and commissioning of ventilation fan with grill size 10'', FRP body and grill suitable for single phase 230 volt AC 50HZ supply. Make of Khaitan,Usha, Crompton,Havells, Orient. Note: To fixing of Ventilation Fan in cabin by cutting the wall of sheet of proper size will be in the scope of contractor. as per Explanatory Note-9 Make: Khaitan ,Usha ,Crompton ,Havells ,Orien, Bajaj. | — | — | — | 91,000 | |
| — | 8.00 | — | — | ||
| Supply ,fixing ,testing and commissioning of Evaporate air cooler as per explanatory note-10 | — | — | — | 82,128 | |
| — | 1.00 | — | — | ||
| Supply, installation testing & commissioning of MDB, incommer 400 -01 nos and outgoing 250 -08 nos as per explanatory note-11 | — | — | — | 2,49,175 | |
| — | 350.00 | — | — | ||
| Supply, laying & Installation of 4 x 400Sq.mm armoured cable as per Explanatory Note-12 | — | — | — | 6,77,250 | |
| — | 4.00 | — | — | ||
| Supplying & making cable End termination of following Aluminum Armoured PVC/XLPE cable. All material required including double compression brass gland, nuts, bolts, PVC tape crimping lugs etc. complete as required for 4x400 sqmm sizes of aluminum conductor cables. as per Explanatory Note-13(i) | — | — | — | 2,000 | |
| — | 14.00 | — | — | ||
| Supplying & making cable End termination of following Aluminum Armoured PVC/XLPE cable. All material required including double compression brass gland, nuts, bolts, PVC tape crimping lugs etc. complete as required for 4x50 sqmm sizes of aluminum conductor cables. as per Explanatory Note-13(ii) | — | — | — | 1,400 | |
| — | 7.00 | — | — | ||
| Supply, Installation, fixing of vertical TPN DB 6 way with 125 amp. MCCB including MCB TP 63 amp 06 nos as per Explanatory Note-14 | — | — | — | 1,68,000 | |
| — | 350.00 | — | — | ||
| Supply, laying & Installation of 4 x 50Sq.mm armoured cable as per Explanatory Note-15 | — | — | — | 1,13,750 | |
| — | 150.00 | — | — | ||
| Supply, Fixing testing & commissioning of Modular LED Ceiling Light 36 W Make Phillips, Havells, Cromption, Bajaj.Note:- All the required material are in contractor scope as per Explanatory Note-16 | — | — | — | 4,50,000 | |
| — | 3.00 | — | — | ||
| Installation testing and commissioning of Cassette Air conditioner 3 tone with all material copper material & accessories like refrigerant piping with nitride Sleeve insulation, interconnecting wiring from Indoor unit & Out door Unit, MS Powder coated Wall / Floor Standing stand for Out door Units. Cu pipe with suitable dia approx. length 20 ft for each AC to connect indoor unit to outdoor unit. As per Explanatory Note-17 | — | — | — | 24,000 | |
| — | 3.00 | — | — | ||
| Supply, Installation, Commissioning of MCCB 32 Amp. 3 Phase with neutral with suitable enclouser for cassette AC, as per Explanatory Note-18 Make : Cromption, Havells, L&T, Hagger, Schneider, Lagrand | — | — | — | 15,000 | |
| — | 2.00 | — | — | ||
| Supply, Testing & Commissioning of Maintenance free Earthing as per explanatory note-19 | — | — | — | 22,220 | |
| — | 20.00 | — | — | ||
| Supply, Installation, testing & commissioning of 65 mm GI Pipe as per explanatory notes-20 | — | — | — | 16,000 | |
| — | 350.00 | — | — | ||
| Excavation and Laying of cable trench under Road/Rly line/RCC/crossing/Pavement area for laying of cable 1 meter deep and 1 meter wide suitable for 6 nos 4x400 sq mm cable including repair the same. As per Explanatory Note-21 | — | — | — | 1,83,750 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tenderdocumentofficebuilding.pdf tender document
ATTACHMENT
Tenderdocumentofficebuilding.pdf
ATTACHMENT
Corrigendum-1.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .