RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Diesel Generators- DG Sets ( 2 pieces ) ( Under PAC ) Make koelgreengfe Model koelgreenkirloskarha294g1 Technical Specifications 1/5 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 15 15
Required20
Required25
Required30
Required40
Required62.5
Required82.5
Required100
Required125
Required160
Required180
Required200
Required250
Required320
Required380
Required400
Required500
Required600
Required750
Required50
Required140 Or higher No of Phase Three Phase Three Phase ENGINE Make of Engine KOEL GREEN/KIRLOSKAR * Model Number of Engine HA294G1 * Capacity of Engine (cc) 1880 * Engine Power (kWm) 15.1 * ISI Marking to IS :10001 for engine Yes * BIS license No
Requiredif applicable CM/L-0290641 * Type of Engine cooling Air Cooled Air Cooled Type of governer Mechanical Mechanical
RequiredElectronic Or higher Class of governer A2 A0
RequiredA1
RequiredA2 Or higher Number of cylinders (nos) 2 * No of Strokes (nos) 4 * Rated RPM of Engine (RPM) 1500 1500 Overload capacity for one hour for every 11 hours continuous running at full load (%) 1 * Specific Fuel Consumption (gm/kWh) 224 * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make KOEL GREEN/LEROY SOMER * AC GENERATOR(ALTER NATOR) model Number KG 40 E * Rating of AC Generator (KVA) 15 * 2/5 Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 89.6 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 3 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel Manual Manual IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
Required1.8
Required2 Or higher Thickness of Foam 20 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * Battery capacity (Ah) 130 * No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) TT-798 dt 12/11/2014 * Name and address of laboratory(Engine) NSIC TECHNICAL SERVICES CENTRE BHAVNAGAR RAJKOT * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) QF-EPGG/QAD/FR/044 dt 16/12/2012 * Name and address of laboratory(Alternator) WITNESSED BY DQA DGS&D BENGALURU * 3/5 DG set meet requirements of Enviro nmental(Protection) Rules 1986
Requiredin respect of noise and emission norms
Requiredas described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 1 1.0 Installation & Commissioning Without Installation Without Installation Agreed to STC of the Product Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.