ML and TP
ML for cleaning
Repair Maint AC
ML taking dwon defective AC unit
REPAIR MAINT AC
Taking Down defective compressor
SF temperature sensor probe
SF PCB Board
SF non functional PCB Board
SF Repair running Capacitor
SF repairs starting capacitor
SF repair indoor outdoor unit
SF repair delivery discharge valve
SF repairs copper tubing
SF repairs insulation copper tubing
supply and filling
Taking down indoor fan motor
Taking down out door fan M&L
T&P for servicing of the Split AC/Tower/window AC 1.5/2.0/3.0/4.0 ton capacity of any make
including oiling/greasing the blower motor
cleaning the evaporator condenser coils externally to remove the dust
replacement of defective thimbles
proper connections of wires etc and re-fixing the air conditioner at its origional position by the experienced ref mech all as directed by Engr-in-Charge (Note :- (i) Any u/s items other than specified above need to be replaced/gas charging etc shall be replaced & paid under seperately respective items.(ii) Servicing of split type AC of capacity 1.5/2.0 TR capacity of any make by washing the outdoor unit condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower
wipe and clean the unit with dry cloth
complete all as specified and directed by Engg-in charge.
M & L for cleaning flushing out the refrigeration system thoroughly with CTC
leak testing with CO2/N2 locating and rectifying the leaks by brazing with silver/copper rod
pressure testing
vaccumising and charging with refrigerant gas and topping up compressor oil
testing and commissioning complete for split type ACs of 1.5 Ton capacity complete all as specified and as directed. (Note : (i) The quoted rate shall deemed to be inclusive of refrigerant gas (R-32/R-22/R-410A/R-134A) (ii) Unit quoted rate shall deemed to be inclusive of Bid Number : GEM/2025/B/6331577 Dated : 04-07-2025 Bid Document 1/27
7952330
GEM/2025/B/6331577
Two Packet Bid
Repair Maint AC
30 days
Ganganagar, Rajasthan
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
2 yrs
₹2 L
20%
Exempted
4 Jul 2025
4 Jul 2025
9 Jul 2025
REPAIR MAINT AC UNIT
ML for cleaning
Repair Maint AC
ML taking dwon defective AC unit
REPAIR MAINT AC
Taking Down defective compressor
SF temperature sensor probe
SF non functional PCB Board
SF Repair running Capacitor
SF repairs starting capacitor
SF repair indoor outdoor unit
SF repair delivery discharge valve
SF repairs copper tubing
SF repairs insulation copper tubing
supply and filling
Taking down indoor fan motor
Taking down out door fan M&L
T&P for servicing of the Split AC/Tower/window AC 1.5/2.0/3.0/4.0 ton capacity of any make
including oiling/greasing the blower motor
cleaning the evaporator condenser coils externally to remove the dust
replacement of defective thimbles
proper connections of wires etc and re-fixing the air conditioner at its origional position by the experienced ref mech all as directed by Engr-in-Charge (Note :- (i) Any u/s items other than specified above need to be replaced/gas charging etc shall be replaced & paid under seperately respective items.(ii) Servicing of split type AC of capacity 1.5/2.0 TR capacity of any make by washing the outdoor unit condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower
wipe and clean the unit with dry cloth
complete all as specified and directed by Engg-in charge.
M & L for cleaning flushing out the refrigeration system thoroughly with CTC
leak testing with CO2/N2 locating and rectifying the leaks by brazing with silver/copper rod
pressure testing
vaccumising and charging with refrigerant gas and topping up compressor oil
testing and commissioning complete for split type ACs of 1.5 Ton capacity complete all as specified and as directed. (Note : (i) The quoted rate shall deemed to be inclusive of refrigerant gas (R-32/R-22/R-410A/R-134A) (ii) Unit quoted rate shall deemed to be inclusive of Bid Number : GEM/2025/B/6331577 Dated : 04-07-2025 Bid Document 1/27
transportation cost to workshop and back (if any)).
All as per Serial item No. 02 above but for 2.0/3.0 Ton capacity Split Acs complete ditto.
Material & Labour for taking down defective split type AC unit
shifting to work shop
taking out any type of defective compressor of capacity 1.5 T capacity from unit
replacing the compressor with new Inverter/Non Inverter compressor as suitable for existing
refixing the compressor in the unit
cleaning refrigeration system with CTC thoroughly
leak testing with refrigerant gas
testing at workshop
shifting to location
reinstalling the same in its original position
connecting up all electrical connections
testing and commissioning all as specified and directed. Note : Rate quoted is deemed to be inclusive of cutting
sealing the refrigeration tubing
replacement of strainer
refrigerant gas and CO2 etc.
required for the job including transportation. Make : Carrier/LG Amtrex/LLoyad/Voltas/Vidiocon/Blue Star
All as described in serial item No.04 and above
but 2 ton capacity compressor from AC unit.
All as described in serial item No.04 and above
but 3 ton and 4 ton capacity compressor from Tower AC unit.
Taking down the defective compressor from the window type ac unit and supply and fix new and factory sealed compressor of same make (including cleaning refrigeration circuit with
cleaning agents flushing through with CO2/N2
complete removal of dirt
oil and carbon etc pressure testing dehydrating
replacment of copper pipe
topping up com pressor oil ) testing and commissioning of window type AC units 1.5/2.0 Ton capacity.Note:- Charging of R-32/R-22 gas will be measured and paid under relevent item of schedule
S & F in replacement Temperature sensor probe in the main circuit suitable for 1.5/2.0/3.0 Ton capacity split/window ACs complete as per the existing make and specifications and as directed.
S & F in repairs PCB board suitable for 1.5/2.0/3.0/4.0 Ton capacity split/window ACs/tower ACs
non Inverter type complete as per the existing make and specifications and as directed.
S & F in repairs PCB board suitable for 1.5/2.0/3.0/4.0 Ton capacity split ACs/tower ACs
Inverter type complete as per the existing make and specifications and as directed.
S & F in non functional PCB board with new suitable for all split type Acs/Tower ACs of 1.5/2.0/3.0 Ton capacity complete indoor and outdoor of Inverter inverter type complete as per the existing make and specifications and as directed. Make : Carrier/LG Amtrex/LLoyad/Voltas/Vidiocon/Blue Star
S & F in non functional PCB board with new suitable for all split type Acs/Tower ACs of 1.5/2.0/3.0 Ton capacity complete Non inverter type complete as per the existing make and specifications and as directed. Make : Carrier/LG/Amtrex LLoyad/Voltas/Vidiocon/Blue Star
S & F in repairs Running capacitor of 45 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed. (Make: Epcos/Unistar/Crompton)
S & F in repairs Starting capacitor of 50 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed. (Make: Epcos/Unistar/Crompton)
S & F in repairs Starting capacitor of 80/100 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed. (Make: Epcos/Unistar/Crompton)
S & F in repairs indoor/outdoor unit fan motor capacitor of 4/6 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed. (Make: Epcos/Unistar/Crompton)
Taking down the unserviceable service valve of suction and liquid line and supply and fix Bid Details 2/27 new service valve suitable for 1.5/2.0/3.0 Ton capacity split type ACs including necessary nut & bolts
gaskets and brazing to the respective line with silver/copper rod and checking for the leakage complete all as per existing make and specifications and as directed.
S & F in repairs delivery/discharge valve suitable for 1.5/2.0/3.0 Ton capacity Split ACs all as per the existing make and specifications and as directed.
S & F in repairs copper tubing of 5/8" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs copper tubing of 3/8" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs copper tubing of 1/4" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs copper tubing of 1/2" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs Insulation for copper tubing of 5/8" dia of Split ACs complete all as per the existing make specification and as directed
S & F in repairs Insulation for copper tubing of 3/8" dia of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs Insulation for copper tubing of 1/4" dia of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs Insulation for copper tubing of 1/2" dia of Split ACs complete all as per the existing make specification and as directed.
S & F in repair Three core
multistranded copper flexible conductor cable
1100 vols grade ISI marked of size 2.5 sqmm complete all as specified and as directed.
Supply and filling R134A/R32/R410A/R600/R-22 Gas for all types of AC Units complete all as specified and as directed.
Taking down the indoor fan motor of evaporator unit air conditioner of any make/type of 1.5 Ton capacity and replacing the same with new motor of same rating
with copper winding
in the same position and testing etc complete all as specified and as directed. (Make : Carrier/LG/Amtrex/LLoyad/Voltas/Vidiocon/Blue Sta).
All as per Serial item No. 29 above but for 2.0 Ton capacity ACs complete ditto.
Taking down out door fan blower motor from air conditioner of any make/type of 1.5 Ton capacity and replacing the same with new motor of same rating
with copper winding
in the same position and testing etc complete all as specified and as directed. (Make : Carrier/LG/Amtrex LLoyad/Voltas/Vidiocon/Blue Star).
All as per Serial item No. 31 above but for 2.0 Ton capacity ACs complete ditto.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_7952330.pdf
GEM_BID
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
specificaton_sheet_2025-06-11-10-51-41_80f813489c48bc641ed25eb70aab6e4c.pdf
BOQ
boq_2025-06-11-10-51-41_775e41a45ae7c12c79cce7095db30a33.csv.pdf
BOQ
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .