Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC H NO 154 VILLAGE SHIKARPUR PO NAJAFGARH NEW DELHI 110043 | WEST | DELHI | 110043 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹38.4 L+₹9,305 (0.24%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹41.1 L+₹2.7 L (7.06%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹41.5 L+₹3.2 L (8.31%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹42.0 L+₹3.6 L (9.50%)Rejected-Finance 08 PINK ENCLAVE MAHESH NAGAR BALAJI VIHAR GOPALPURA JAIPUR RAJASTHAN 302015 INDIA | JAIPUR | RAJASTHAN | 302015 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹98,840
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
SPL REPAIR TO BLDG NO H-22 OF 972 LT AD MSL REGT (SP) WORKSHOP UNDER GE (EAST) DELHI CANTT-10
2022_MES_531763_1
GE/DE-12/2022-23
Open Tender
Civil Works
Item Rate
120 days
GE (EAST) DELHI CANTT-10
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹98,840
Yes
6 Oct 2022
17 Jun 2022
30 Jul 2022
17 Jun 2022
27 Jul 2022
4 Jul 2022
Amount
M&L for 0.50mm thick prepainted galvalume aluminium zinc coated GI based semi corrugated/profile steel sheeting of any colour, having tensile strength of 550MPA as in roof covering, wall cladding with self tapping screws or 'L' type of 'J' type or cranked hook bolts in lieu of screws as per manufacturers instructions including dismantling translucent PVC or Asbestos cement corrugated sheets including ridges as in roof coverings, complete all as specified and as directed.
All as per item No 1 but steel sheet made out of plain sheet for Ridges/flashing as per size and shape required site condition complete all as specified and directed by the Engineer-in-Charge.
Taking down chowkhats or frames exc 1.5 Sqm but n.exc 4.0 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutter (without taking off shutters) not exceeding 1.5 Sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exceeding 1.00 Sqm but not exceeding 2.00 Sqm each.
Demolition of cement concrete (unreinforced) in ground floors and paving’s n exc 15cm thickness complete all as specified and directed by Engr-n-Charge.
Demolition of cement concrete (reinforced) of any position and any description not otherwise specifically provided for and including reinforcement required to facilitate demolition upto and including and removal of debris and rubbish out side MoD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) & removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for providing reinforced cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in kitchen slab, Chajjas, lintels complete all as specified and directed. Note : The rate quoted by the contractor is deemed to include the necessary scafoldings, supports etc. Nothing extra will be claimed on this account. The work will be executed upto G+4 Stories building.
S&F TMT bars upto 10mm dia and over, cut to length, bent to shape required,including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins,arches,pillars,etc but excluding ashlar facings dressed stone work and precast concrete articles including removal of debris and rubbish out side MoD land complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC of Reinforced concrete) pipe up to 150 mm bore set in cement mortar complete all as specified and directed.
Dismantling bricks tiles or terracing tiles single layer on roofs and including removing the waste materials to a distance of 500 meters complete all as specified and directed by Engr-in-Charge.
Demolition of mud /cement concrete on roofs any thickness including plastering and leeping including cleaning surface of roof with wire brush/mechanical brush throughly to remove old dirt and removal the same the existing premises, complete all as specified and directed by Engr-in-Charge.
M & L for PCC 1:2:4 type B-o using 12.5mm graded stone aggregate with WPC as in padding to maintain proper slope as required all as specified and directed by Engr-in-Charge.
M & L for 15 mm thick screed bed or bedding layer of cement mortar 1:4 on brick work or concrete surfaces using water proofing compound, from 1st to 4th floor including necessary scaffolding and safety, complete all as specified and directed
Supply Liquid Water Proofing compound
M&L water proofing treatment to roof slab with APP modified membrane weight not less than 3.5 kg/sqm and thickness of membrene not less than 3 mm water absorption of not more than 1% on mass within 24 hrs and water tightness/impermeability at 2 kgf/Cm2 on primed surface and applying hot bitumin @ 1.2 Kg/sqm for fixing APP membrene and seled joint with torch application. all as specified and directed with following description :- (a) Before laying APP membrene entire surface shall be plastered with 10 mm thick in CM 1:4 with using water proofing liquid 150 ml per bag of cement, curing , drying and applying evenly a coat of bituminous oil based primer @ 0.30 kg/sqm and then layibng APP modified membrene with 100 mm over lap in longitudinal direction and 100 mm over lap in transverse direction all joints and changes in all direction should be curved with cement at corners and cured well before laying the membrene. (Note : APP to be done by authorised applicator)
M&L Precast machine pressed cement concrete tiles, factory made, 250mm x 250mm x 20-25mm thick, pointed in cement mortar 1:3 in floors, laid over 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed.
S&F in repair stainless steel wire cloth, 0.56 mm nominal dia. of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed. Note- Welder with welding machine reqd to fix wiremesh in old steel windows
M&L hacking out old broken glass (any thickness and size quality or description from wooden frame glazed with putty,metal frame including punching or drilling out old glazing pins/spring clips) complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel wire cloth, 0.36 mm nominal dia. of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed.
M&L 4mm thick sheet glass, ordinary quality, in squares n.exc. 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-Charge.
M&L 5.5mm thick sheet glass, ordinary quality, in squares exc. 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-Charge.
M&L PVC pipe 150mm bore double socketed in any length with rubber ring joints complete all as specified and directed by Engineer- In- charge.
M&L PVC bend 150mm bore any radius complete all as specified and directed by Engineer- In- charge.
M&L PVC pipe 110mm bore double socketed in any length with rubber ring joints complete all as specified and directed by Engineer- In- charge.
M&L PVC bend 110mm bore any radius complete all as specified and directed by Engineer- In- charge.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
Dismantling structural steel work including doors, gates,rafter ,purlin etc similar works complete all as specified and directed
Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-n-Charge.
M&L brick work with sub class B bricks, straight or curved on plan exc 6 m mean radium built in CM 1:6 all as specified and as directed.
Brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed
M&L coloured vitrified tile 10mm thick (square/rectangular) polished, area of each tile exceeding 0.16 Sqm but not exceeding .36 Sqm in floors laid over screed bed of 15mm thick in CM (1:6) etc set and jointed in neat cement slurry and pointed white or coloured cement to match incl demolition of existing flooring complete all as specified and directed by Engineer-in-Charge.
All as per serial item No 34 above but on vetical surfaces like Jambs,Pillar ,Riser etc 10 mm rendering in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match over incl demolition complete all as specified and as directed.
S&F glazed ceramic coloured tiles of size 450x350x7mm thick in vertical surface and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over 10 mm thick backing coat in CM 1:4 complete all as specified and directed by Engr-in-Charge.
Taking down eaves ,gutters, and rain water pipes (any size or pattern) including all fitting
S&F 1.0 mm thick of laths steel sheet eaves gutters,galvanised class 3 half round with round edges.
S&F in repair 1.25mm thick of laths steel rolling shutters,without ball bearing,as specified including top cover, including bending to the required shape, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated complete gear operated type with bevel gear box and crank handle complete all as specified and directed by Engr-in-Charge.
M&L 35mm thick factory made glazed and Skelton shutter of second class hard wood (Hollock/Bija/Sal/Benteak) open rebated and prepared to receive wire cloth, glass etc (without sash bar ) edges of framing plain, chamfered or rounded , fitted with cut and mitered beads for securing glass , wire cloth etc, size of members of shutters as specified in SSR Part-I, Section-8, clause 8.20 (a) complete all as specified and directed by Engineer-in-Charge.
Aluminium alloy powder coated (50 micron) anodized door frame of section 100mm x 44 mm x 2 mm thick, door shutter of aluminium section of size 85 mm x 44 mm x 2 mm thick, top rail and both styles of size 100 mm x 44 mm x 2 mm thick, lock rail and bottom rail of size 115 mm x 44 mm x 2mm thick incl aluminium anodized snap beading and rubber packing & 5.5 mm thick colour designer glass (single/double leaf) incl 200 mm long tower bolt-2 Nos, 200 mm long Alm handle -02 Nos on each leaf, 4 lever lock brass 100 mm long mortice lock (Make :- Godrej), & double action floor door spring(Sandhu/Samrat) heavy duty suitable for 1 m wide shutter for each leaf, complete all as specified and as directed.
S&F powder coated three track aluminium (glazed/ gauged) window shutters sliding type incl 5.5mm thick glass or stainless steel wiremesh, without sash bar aluminium section weighting 0.55 Kg per mtr including frame and necessary joining cleats, glazing clips, rubber packing, anodised aluminium beading , sliding channel,roller screws including fittings complete all as per direction of Engr-in-charge.
M&L preparation new wood surface and applying two coats of synthetic enamel paint over a coat of pink primer of any description not otherwise described over 10cm width or girth complete all as specified and directed by Engineer-in-Charge.
M&L for painting to old wooden surface of any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M & L preparation of new surfaces of steel any description not otherwise described over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of Red-oxide Primer complete all as specified and directed by Engineer- In- charge.
M & L preparation of old surfaces of steel any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer- In- charge.
M&L 10-12 mm thick polymer modified readymix cement based plaster make ultratech (brand name readiplast) or equivalent in ratio of 1:4 on brick or concrete surface etc .on wall finished even and fair without using extra cement all as specified.
M/L preparation of new plastered surface of wall and applying two coats of cement base paint over a coat of alkali resitance primer l complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old scrapped/new decorated external wall surface of existing treatment by scrapping with TruCare Wall Sander : L01/H-01 (having mechanical vacuum mechanissm) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying high quality acrylic modified resin based texture of Dolpurtex Bricks copper-0587 Pattern or other any shade /pattern with anti alage and UV resistance property to be applied as in intermediate finished in desired pattern @ 43.04 kg/10 Sqm to form film of 1-1.50mm thickness after scrapping and properly cleaning the surfaces to remove loose particles from the plaster surfaces and applying coating with premium acrylic smooth exterior paints with silicone additives of required shage by two or more coat @1.43 Ltrs/10Sqm over and including one coat of premium quality primer over 2mm thick wall care putty complete all as specified and as directed by Engr-in-Charge. (Note: (a) Stage for perparation of surfaces shall be got approved from GE before applying the finishes. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator. (c) Crack shall be widened to form 'V" Shaped groove with help of Chiesel/Cutter. (d) Clean the area thorougly to make it free from dust and loose particles. (e) Applying a self priming coat (1:1) dilution with water and smart care textured crack filler over cracked edges and allow to dry it for 1-2 Hours. (f) Apply first coat of undiulated smart care textured crack filler on the crack using spatula or putty Knife. (g) Press the paste firmly in the crack to ensure full contract with the surface. (h) Spread smart care textured cracks filler upto at least three CM on either side of the crack for better adhesion. (j) Apply in consecutive perpendiculer layers to avoid leaving air pockets. (k) Allow to dry for minimum 06 Hrs than apply the second undiulated coat in the same manner as required. (l) This work to the building shall only be executed by making proper scafoling all around the bldg upto full hight and this stage shall be apporove by GE. The unit rate quoted by contractor shall deemed to include the above aspects. No Jhula work shall be allowed. Make : Asian Paints or equivalent make as decided by GE.
M & L preparation of old surfaces and apply two coats of oil bound distemper over one coat of primer complete all as specified and directed by Engineer- In- charge.
M & L preparation of new surfaces and applying two coats of oil bound distemper over one coat of primer complete all as specified and directed by Engineer- In- charge.
Box type Steel windows with double shutters (inside for wiremesh & out side for glass), hinges, steel handle, tower bolt and steel peg stay complete with Guard bars dovetailed or welded including a coat of red oxide after preparation of surface before fixing all as shown in drg No. TD-A sheet 1/3 to 3/3, complete all as specified and as directed. (Nothing extra shall be paid on this account) (Note: For measurement purposes out to out dimension of window shall be taken to arrive at par unit area).
S & F 35 mm thick factory made panelled shutters (Single panel/two panel) of second class hard wood, (Hollock ) plain framed with lock rail and panel of 9mm B. W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces with moulding (20mm to 12mm ) on both side of shutters. The size of rail and style as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer- In- charge.
S&F for 150 mm long Floor door stopper of aluminium alloy body and tongue anodised with hard draw steel spring fixed in floor, complete all as specified and directed by Engr-in-Charge.
M & L 125mm long Aluminium handle Powder coated cast type anodized complete all as specified and directed by Engineer- In- charge.
S&F for 200mm long aluminum anodized barrel tower bolt extruded aluminiun alloy section and fixed all as spd and directed.
S&F 100mm long butt Hinges, medium weight, cold rolled mild steel complete
S&F 300 mm long aluminum alloy anodized sliding door bolt with hasp and staple(bolt type)and fixing clips of sheet cast sec and fixing bolts and sliding bolts of extruded sec or cast aluminum alloy and fixed all as spd and directed.
M&L 100 mm thick PCC 1:2:4 type B1 using 20 mm graded aggregate as in flooring complete all as specified and as directed.
S&F MS framed work as in door or gates of angle or other section with gusset plates,rail, braces,etc and similar work incl primer conform-ing to Fe 410-0 or Fe 310-0 complete.
S&F MS angle iron, pipe, tube (Square/rectungualr) etc as in rafters, purlins ,ladder etc.complete all as specified and directed by Engineer-in-Charge.
M&L Kota stone slab 20-25 mm thick with uniform texture in floor with laid over and including 15 mm thick screed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
M&L kota stone slab with uniform texture of 20-25 mm thick in tread of steps, riser of steps, skirting, dado and pillars in one single piece (size decided by Engineer-in-Charge) laid over and including cement screed 15mm thick in cement morter 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing , bevelled edge of corner etc complete all as specified and directed.
Providing and fixing false ceiling at all height with GRG(Glass Fibre Reinforced Gypsum) False ceiling tiles of size 595x595mm of approved texture design and patterns having moisture content less than 2%,humadity resistance of 99%,NRC 0.85(with 50mm thick glass wool) as per IS 8225 :1987,Non combustible as per BS 476 (part-4)-1970 and light reflectance of 75-85% to be laid in true horizantal level suspended on inter locking metalT-grid of hot dopped galvanised iron section of 0.3 mm thick (galvanised@120grams per sqm including both sides) comprising of main -T runners of size 24x32 mm of length 3000mm.cross-T of size 24x26mm of length 1200mm and secondary intermediate cross T of size 24x26 mm of length 600mm to form grid module of size 600x600mm,suspended from ceiling using galvanised mild steel items(galvanised@80 grams per sqm) i.e 50mm long,8mm outer diameter M-6 dash fasteners,6mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2mm galvanised iron perimeter wall angle of size 24x24x0.4 mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl pluges at 450mm centre to centre and 40 mm long dry wall stainless steel screws, complete all as specified and as directed. (Make: Diamond Ceiling or equivelant make as decided by GE)
Taking down carefully old unserviceable copper/aluminium point wiring From existing conduit / batten type (light, fan, socket or power point) complete such as switches, ceiling rose, pendent holder, regulator and socket etc and making good the disturbed surface of complete all as directed.
M&L for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated un-sheathed and multistranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers except conduit junction box (junction box will be of MS) including FRLS, PVC insulated unsheathed 1.5 Sqmm multistranded copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for with & includig 3mm thick hylem sheet for mounting switch, socket ,fan regulator etc making good surface complete all as directed for the following :-
(a) One light point / fan point/ wall fan point/ bell/ buzzer controlled by one 1-way switch/ bell push.
(b) One socket outlet point 5 amps on the same board.
(c) One socket outlet point 5 amps on the independent board.
All as per srl item No 66 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire complete all as specified .
S & F of switch piano flush type 5 Amps SP one way all as specified.
S & F of switch piano type 15 Amps SP one way all as specified.
S & F of socket outlet 2-in-1,5 Amps flush type 3 pin 5 Amps multi purpose all as specified.
S & F of socket outlet 2 in 1 (multipurpose) 3 pin 5 and 15 Amps flush mounted type all as specified.
S&F ceiling rose surface bakelite 65 x50mm with two to threeterminals.
M & L of fan regulator stepped electronic flush type suitable for 1200/1400 mm sweep fan as per existing pattern.
Material and labour in replacement for Sub main wiring with 2 run of 10.0 Sqmm (nominal area) FR, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 10.00 Sqmm (nominal area) FR, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified
Material and labour in replacement for Sub main wiring with 2 run of 4.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 4.00 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified.
Material and labour in replacement of LT underground cable XLPE insulated, PVC Sheathed armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 4 core ISI marked including all connections with thimbles of suitable size, complete all as directed.
Supply and fixing in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections complete all as directed.
Supply and fixing in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 08 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections complete all as directed.
Supply and fixing in replacement of MCB C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed.
Supply and fixing in replacement of isolator 63 Amp, SPN type complete all as directed.
Supply and fixing in replacement of LED tube light fitting,20 watt. with and including all electric connections complete all as specified and as directed.
Supply and fixing in replacement of LED mirror light fitting 10 watt, cool/warm white and making all electric connections complete all as directed.
S & F in replacement of wall mounted light fitting metal body fancy type with opel glass for LED lamp with fixing accessories complete all as specified and as directed.
Supply and fixing in replacement of LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S&F in replacement of energy efficicent LED industrial light fittings incl powder coated PDC aluminium housing LED Highbay with reflector 200W complete with all fixing accessories as directed by Engr-in-charge.
Supply and fixing LED security light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed
Supply and fixing in replacement of security light fitting bracket, 1.0 mtr long made out of galvanized iron pipe of 40 mm dia size light grade bent to shape complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed.
Supply and fixing in replacement of sheet metal enclosure, SPN type with two pin & earth plug and socket (Industrial type DB) with and including one MCB SPN, C Curve type of capacity 20 Amp, 10 kA complete all as directed.
S & F in replacement of Exhaust fan 450 mm sweep metal type, DB incuding self closing louver and making all electric connections complete all as specified and directed.
S&F in replacement of copper bus bar chamber of rating 400Amp , 415 Volt with and including copper thimble and connecting accessories complete all as specified and directed.
S&F in replacement of change over switch off load type AC, 415 Volt, TPN 200Amp side handle operated heavy duty in sheet metal encloser complete all as specified and directed.
Excavation in trenches in loose/soft soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out including forming bottom surface for laying LT cable as specified and directed at site by Engineer-in-Charge.
Returning filling in soil including spreading, levelling, watering and well rammingin layers not exceeding 25 cm complete as specified and directed by the Engr-in-charge.
Removing exccavated soil not exceeding 50 mtr and depositing wheredirected at a level not exceeding 1.5 mtr above the starting point complete as specified and directed by the Engr-in-charge.
M&L for sand cushioning to under ground cable provided with layers of snad(8 cms deep before laying the cable and 15 cms deep after laying) complete all as specified and directed at site by Engineer-in-Charge.
Supply and laying burnt bricks class - B for protection of cable complete all asspecified and directed at site.
M&L for in replacement earthing complete with GI earth plate electrode 600 mmx 600mm x 6mm thick burried directly in ground not less than 2.25 mtrs below ground level, with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4 mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade for protection of earthing lead and GI pipe 20 mm dia for watering pipe with funnel, wire mesh, salt, charcoal dust and excavation complete all as directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .