Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹32.2 L+₹2.9 L (9.81%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Not L1 bidder | |
| 3 | L3₹32.2 L+₹2.9 L (9.90%)Rejected-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L3 | Rejected-Finance Not L1 bidder | |
| 4 | L4₹38.1 L+₹8.8 L (29.9%)Rejected-Finance | L4 | Rejected-Finance Not L1 bidder |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
12 Jul 2021, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
MAINTENANCE REPAIR REPLACEMENT OF STREET LIGHT, EXTERNAL ELECTRIFICATION WORKS AND OTHER CONNECTED WORKS AT ASC COLLEGE, ASC SOUTH AND OTHER VARIOUS LOCATION UNDER GE CENTRAL BANGALORE
2021_MES_450980_1
8137E
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹70,000
Yes
27 Sept 2021
12 Jun 2021
14 Jul 2021
12 Jun 2021
12 Jul 2021
28 Jun 2021
12 Jun 2021 - 27 Jun 2021
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in hard/dense soil complete all as specified and directed.
All as per item No 1 above but exc 1.5 metre and not exc 3.0 metre deep.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Taking out/down old/unserviceable under ground HT/LT cables of any size and connections including pipes, cable protection bricks etc from trenches/duct/walls/poles/roof tops of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site as specified and directed. (Note : (i) Earth work shall be measured and paid separately under relevant items of this schedule. (ii) Old serviceable bricks shall be stacked at site for reuse including cleaning complete without any extra cost to the Department.)
M & L for Sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supply and laying well burnt bricks, locally available best quality bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
Laying only old serviceable bricks obtained against Sch 'A' item No 05.00 here-in-above/befpre, laid flat, dry with width of the bricks laid to axis of the cable for protection of cable all complete as specified and as directed by the Engr-in-Charge.
Supplying and laying un-reinforced precast conncrete cable cover type 2, size 300X180X40mm thick in trenches for protection of HT cable all as directed.
Provision of trenchless bore using mechanical nuematic drilling equipment for passing electric cables through HDPE pipe of 100mm dia under the existing bituminous/WBM road/PCC hard standings, depth range not less than 1.0 mtr and upto 1.5mtr and making good to the distrubed surfaces of road to match with its existing specifications all as specified and directed by engr-in-charge at site. Note : 1. Quoted rates deems to be inclusing of necessary earth work, transportation charges of Drilling machine, and cost of HDPE pipe and passing pipe through bore complete. 2. Any damage to MES assets caused during trenchless bore shall be recitfied by the contractor at his own cost.
S&F in replacement mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 40mm bore dia.
S&F in replacement mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 50mm bore dia.
S&F in repairs Modular Junction box made of SMC/FRP of size 240X130X95mm (weather proof) with locking arrangement, hinged door, suitable to accomodate 2 Nos of FRP insulators for taking branch connection of street light from LT UG cable including provision of MCB SP, 6-32A, 10 KA, 'C' Curve, 01 No complete fixed to street light pole with suitable size of mild steel FI clamps, nuts & bolts complete all as specified and directed. (Make - Sintex, CAT No : GSJB 2817 or equivalent model of make as per list of manufacturer attached).
Supply and fixing in repair PVC insulated three core 1.5 sqmm cable stranded copper conductor flexible cable with earth conductor complete all as directed.
S&F Rigid non-metallic PVC conduit of 20mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.
Laying only serviceable PVC insulated, armoured UG cable of any size, connecting, jointing using new glands, lugs etc and testing on completion complete all as directed. NOTE : - Old serviceable cable retrieved under item No 05 above shall be used for laying under this item.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, 2 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, 4 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, 4 core, nominal cross sectional area of main conductor 25 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, PVC insulated ,3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 25 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, PVC insulated ,3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 50 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, PVC insulated ,3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 70 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, PVC insulated ,3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 120 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 11000 Volts earthed, under ground HT cable, PVC insulated, armoured, 3 core, nominal cross sectional area of main conductor 95 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 11000 Volts earthed, under ground HT cable, PVC insulated, armoured, 3 core, nominal cross sectional area of main conductor 240 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
Supply, jointing and testing LT UG XLPE cable straight through joints (Tubular sleeve virson) including jointing materials and accessories complete, heat shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts cable of size 10 Sqmm, 2 Core complete all as specified and directed.
Supply, jointing and testing LT UG XLPE cable straight through joints (Tubular sleeve virson) including jointing materials and accessories complete, heat shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts cable of size 16 Sqmm, 4 Core complete all as specified and directed.
Supply, jointing and testing LT UG XLPE cable straight through joints (Tubular sleeve virson) including jointing materials and accessories complete, heat shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts cable of size 25 to 50 Sqmm, 4 Core complete all as specified and directed.
Supply and fixing heat shrinkable type cable end jointing kit for HT 11000 volts grade (Earthed) UG cables complete with jointing materials and acessories suitable for 3 core XLPE aluminium conductor cable of size 50 sqmm to 95 sqmm.
Supply and fixing heat shrinkable type cable end jointing kit for HT 11000 volts grade (Earthed) UG cables complete with jointing materials and acessories suitable for 3 core XLPE aluminium conductor cable of size 240 sqmm to 300 sqmm.
Supply and fixing jointing kit for HT 11 KV (Earthed) grade UG cables for straight through heat shrinkable type joint complete with jointing materials and acessories suitable for 3 core XLPE aluminium conductor cable of size 95 sqmm to 240 sqmm.
Supply and fixing jointing kit for HT 11 KV (Earthed) grade UG cables for straight through heat shrinkable type joint complete with jointing materials and acessories suitable for 3 core XLPE aluminium conductor cable of size 240 sqmm to 300 sqmm.
M & L for Cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint including taking down old rusted/damaged cross asrms complete all as specified and directed.
M & L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 150 mm height 150mm dia suitable for 11000 volts grade complete all as specified and directed.
M & L for disc type insulator (white or brown), porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, two-in-series assembly for tension with tension clamps for conductor worjing pressure 11000 volts grade all as directed.
S & F aluminium conductor steel reinforced (ACSR) conductor of size 1 of 6/1 x 2.11mm (Squirrel) including binding, straining in LT over head line including all jumper connection and binding on insulator with new wire/aluminium tape including taking down old ACSR complete all as specified and directed.
S& F in replacement MCCB, 4 pole, 415 volts, 25 kA breaking capacity, 63 Amps with adjustable thermal and adjustable megnetic release all as directed.
S& F in replacement MCCB, 4 pole, 415 volts, 25 kA breaking capacity, 160 Amps with adjustable thermal and adjustable megnetic release all as directed.
S& F in replacement MCCB, 4 pole, 415 volts, 25 kA breaking capacity, 200 Amps with adjustable thermal and adjustable megnetic release all as directed.
S& F in replacement MCCB, 4 pole, 415 volts, 25 kA breaking capacity, 250 Amps with adjustable thermal and adjustable megnetic release all as directed.
Trimming of tree branches around the HT or LT overhead conductor, poles & stays (not less than 3 metre) to clear the approach of overhead lines including removing of nest, wild grass creepers, unwanted vegetation, etc from pole/stay including cleaning of creepers climbed on poles and angles, channels and disposed off from site to nearby waste deposit complete all as specified and directed by the Engr-in-Charge. (Note : Horizontal distance of tree touching to overhead line shall be measured and paid.)
S&F cast iron cable route indicator with embrossing mark as HT cable, circular type, 75mm dia duly fixed with suitable MS flat iron member to be embeded in PCC (1:3:6) type C1 block of size 150x150x300mm deep in ground complete all as specified and directed. NOTE :- Route indicator shall be provided at 50 metre interval and at every turning point.
Dismantling air break GOD switch, vertical/horinzontal mounted including insulators and operating mechanism for repair/replacement of broken/damaged/worn out components and insulators complete all as directed.
Supply, installation, testing and commissioning HT 11 KV switch Air Break Gang Operated triple pole, horizontal type double break mechanically operated mounted on insulators and steel frame with operating mechanism system, work from ground level for current rating upto 400 Amps all as directed.
Taking down unserviceable HT lightning arrestor and supply & fixing new HT suitable for 11000 Volts grade metal oxide type (expulsion type) lightning arrestor with all acessories clamps for foxing, connection, discharge capacity 65 Kilo Amps complete all as directed.
Taking down damaged DO fuse assembly and supply & fixing new DO fuse assembly expulsion type fuse single pole 11000 Volts grade of current rating above 50 to Amps, mounted on 2 number insulators and steel frame work, connection with GOD using ACSR conductor jumpering wires and outgoing HT cables all as directed.
Material and labour for servicing of existing triple pole Gang Operated Switch (in position) with discharge switch triple pole horizontal, mechanically operated mounted on insulators and steel frame with operating mechanism and earth operating system, worked from ground level for current rating upto 400 Amps three phase including replacement of male and female blades, tinned copper flexible jumper, MS jumper carrier and greasing with suitable material complete all as directed. NOTE : - Qouted rate under this item shall deemed to be inclusive of the cost of all spares including cost of grease.
M & L for Preparation of old painted rusted steel/iron surfaces of 9 metre steel tubular electric pole including cross arms other acessories/fittings by scraping properly and applying one coat of aluminium paint including rewriting pole number using suitable tint paint making circular shape background and painting using synthetic enamel paint upto 80 cm height from the top of coping with multicolour strips as per colour code complete all as specified and directed.
M & L for Preparation of old painted rusted steel/iron surfaces of 11 metre steel tubular electric pole including cross arms other acessories/fittings by scraping properly and applying one coat of aluminium paint including rewriting pole number using suitable tint paint making circular shape background and painting using synthetic enamel paint upto 80 cm height from the top of coping with multicolour strips as per colour code complete all as specified and directed.
M & L for Preparation of old painted rusted steel/iron surfaces of four pole structure (ie four 11 metre electric pole and steel member frame works, cross arms and other acessories/fittings) by scraping properly and applying one coat of aluminium paint including rewriting pole number using suitable tint paint making circular shape background complete all as specified and directed.
M & L for preparation of old surfaces of 9 metre long RCC/Pre- stressed concrete electric pole and applying two coats of weather coat acrylic exterior paint (ie Apex Ultima of ASIAN Paints) over a coat of primer from 80 cm above coping upto top of pole and applying two coats of synthetic enamel paint upto 80 cm height from top of coping with multicolour strips as per colour code writing pole number including painting to steel members like cross arms, brackets, cable protection pipe, clamps etc using aluminium paint complete all as directed.
M & L for preparation of old surfaces of 11 metre long RCC/Pre- stressed concrete electric pole and applying two coats of weather coat acrylic exterior paint (ie Apex Ultima of ASIAN Paints) over a coat of primer from 80 cm above coping upto top of pole and applying two coats of synthetic enamel paint upto 80 cm height from top of coping with multicolour strips as per colour code writing pole number including painting to steel members like cross arms, brackets, cable protection pipe, clamps etc using aluminium paint complete all as directed.
S & F in repair LED post top of 25 Watt (CORAL (OPAL) of Havells make) new generation energy saving and environmental friendly long life aesthetically design with symmetrical light distribution spun aluminium landscape luminaire with high power LED as light source, IP-65 fixed on existing Gate post using new bolts nuts clamps connecting up by using 2.5 Sqmm copper conductor, multi-stranded copper conductor cable of required length complete all as specified and directed. (Make:- Havells Cat No CORALPT25WLED757PSYMTOPC or equivalent model of Bajaj/Philips/CG/Wipro/Eveready as approved).
S&F energy saving environmental friendly long life, with highly effective and efficient luminaire robust design LED street/building security light 1x 45 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 and wired with all accessories connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make: Havell's Cat No. ENDURAPEARLNEOSL45WLED757PASYTOPC or equivelant of make Bajaj/CG/Shakti/Wipro
S&F energy saving environmental friendly long life, with highly effective and efficient luminaire robust design LED street/building security light 1x 60 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 and wired with all accessories and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make: Havell's Cat No. ENDURAPEARLNEOSL60WLED757PASYTOPC or equivelant of make Bajaj/CG/Shakti/Wipro
S&F energy saving environmental friendly long life, with highly effective and efficient luminaire robust design LED street/building security light 1x 70 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 and wired with all accessories and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make: Havell's Cat No. ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivelant of make Bajaj/CG/Shakti/Wipro
S & F Street light bracket arm of length not less than 1.5 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with 2 pair 50X3mm size MS flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer in MS clamp complete all as specified and directed.
Supply and fixing LED driver 240 volts 200 watt for street light/ flood light complete all as directed. MAKE : - BAJAJ/HAVELLS/CG/WIPRO
Supply and fixing LED driver 240 volts 160 watt for street light/ flood light complete all as directed. MAKE : - BAJAJ/HAVELLS/CG/WIPRO
Supply and fixing LED driver 240 volts 70 watt for street light complete all as directed. MAKE : - BAJAJ/HAVELLS/CG/WIPRO
Supply and fixing LED driver 240 volts 60 watt for street light complete all as directed. MAKE : - BAJAJ/HAVELLS/CG/WIPRO
Supply and fixing LED driver 240 volts 45 watt for street light complete all as directed. MAKE : - BAJAJ/HAVELLS/CG/WIPRO
Supply and fixing LED driver 240 volts 25 watt for street light complete all as directed. MAKE : - BAJAJ/HAVELLS/CG/WIPRO
Supply and fixing street light controll analog type time switch 250 Volts single phase rating with complete connection all as directed. MAKE : - L&T/Havells/Legrand/ABB
Fabricate, install and testing in replacement factory made, pole mounted canopy headed single door outdoor type, weather proof totally enclosed street light controlling panel of size 55cm x 50cm x 40cm suitable for 3 phase 4 wire 440 volts made out of 3 mm thick CRCA sheet, cubical type, powder coated paint inside and outside, having front hinged door with neoprene rubber gasket including danger notice board/plate earth terminal point, bottom detachable gland plate with holes for incomming and outgoing cables provision fixing arrangement with clamps made out of Mild Steel flat iron 40X5mm including bolts & nuts andinternal connection using suitable size copper conductor cable complete with the following accessories:- (a) MCCB, 4 pole, 415 volts, 25 kA, 63 Amps Capacity with thermal load release relay- 1 No (for incoming) (b) Astro type time switch 110-240 volts suitable for 24 hours operation of street light. Make : - L&T/ Legrand/Havells/ABBB (c) Contactor three pole 40 Amps 415 volts coil operating voltage 230 volts. Make L&T MNX 40 or equivalent of Legrand/Havells/ABB (d) Auto manual switch 10 Amps - 02 Nos. Make : - L&T/Legrand/ABB (e) MCB TPN 32 Amps, 10 KA, 'C' curve - 02 Nos
Taking down damaged RCC electric pole any size/height and fixed in any position and Supply & fix/errection in true vertical position new 9.00 metre long steel tubular swaged pole complete with cast iron base plate , finial taper plug ,bolts, nuts & screws as specified type 410 SP -31 fixed in position including two coats of black bituminous painting externally upto planting depth and remaining portion two coats of aluminium paint over one coat of red oxide primer and making alternate black and white strips 30 cm height each (Total 5 strips), writing pole number (06 numbers letter/figure of 2" height) complete all as directed. NOTE :- Excavation and PCC works will be measured and paid seperately under respective items of BoQ.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded hard granite stone aggregate) in foundations for pole or in filling as directed by Engineer-in-charge.
PM&L for PCC 1:3:6 type C1 (using 20 mm graded hard granite stone aggregate) as in coping to Electric Pole including necessary form work and finishing the external surfaces of concrete with 10 mm thick plastering in CM (1:4) finished even and smooth complete all as directed. (Note Quoted rate is deemed to be inclusive of form work and plastering complete.)
Taking out existing stone metal/aggregate and stacking aside at site for reuse/re-spreading after cleaning, removing grass, vegitation etc including levelling the existing ground level by ramming etc and finally spreading the old stone metal/aggregate in existing location all as directed.
Supply and spreading stone metal/aggregate of size not exc 40mm at sub-station/transfomer yard levelled properly complete all as directed.
Material and labour for preparation old steel section (ie post and other steel members) and chain link fencing and applying one coats of aluminium paint complete all as directed.
Material and labour in repair for earthing complete with galvanized steel earth plate 60cmx60cmx6mm thick electrode, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip of 25 x 4 mm up to test point by means of nuts, bolts, check nuts and washers of GI including excavation and earth work, PCC 1:3:6 type C-1 pit, 20mm dia GI pipe medium grade, watering pipe and 32 mm bore GI pipe, light grade for protection of earth strip, MS angle iron frame 40x40x3mm , 40 mm thick RCC 1:2:4 type B-1 cover reinforced with 6 mm dia MS bars @ 75 mm C/C both ways and with MS handle made out of 12 mm dia bars, funnel , wire mesh etc complete all as shown in electrical plate No 5 of SSR part-I and connected to earthing test point all as specified or indicated including testing on completion complete. NOTE :- Qouted rate shall deemed to be included 7.50 metre long earth trips.
NAVREET CONSTRUCTION
M/S - KRUPA ELECTRICALS
RAMSON TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .