Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical QUALIFIED |
| 2 | Accepted-Technical | Accepted-Technical QUALIFIED |
| 3 | Accepted-Technical | Accepted-Technical QUALIFIED |
Tender Value
₹62.0 L
EMD Value
₹1.2 L
Closing Date
19 May 2026, 2:00 pmClosed
Office of the Executive Engineer TLMD III Udhampur
Office of the Executive Engineer TLMD III Udhampur
Protection Wall of 220 132 33 KV Grid Sub Station Ramban Udhampur
2026_PDD_308839_1
TLMD-III/Udh/03 of 2026-27 Dated 27-04-2026
Open Tender
Civil Works
Turn-key
180 days
Udhampur
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Office of the Executive Engineer TLMD III Udhampur
₹1.2 L
Office of the Executive Engineer TLMD III Udhampur
18 Jun 2026
28 Apr 2026
20 May 2026
28 Apr 2026
19 May 2026
28 Apr 2026
11 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1220/132/33 KV Grid Sub station Ramban | |||||
| 1.01 | Construction of protection wall in 1:6 RRM with base pad in 1:4:8 (including dismantling, disposal if any). The Thickness of Base pad is 0.10 mtr. The job includes exacavation, providing & supply of all constructional material, Mechanical & Manual transport, farm work, curing and completion in all respect | - | cu.m | 100 | - |
| 1.02 | Construction of Drain in 1:6 RRM with base pad in 1:4:8 (including dismantling, disposal if any) .The section of drain is 0.5 MtrX0.5 Mtr. The Thickness of Base pad is 0.20 mtr.The job includes exacavation, providing & supply of all constructional material, Mechanical & Manual transport, farm work, curing and completion in all respect | - | RM | 100 | - |
| 1.03 | Removal of malba from drain in 33kv yard, control room, around sba quarters and 132kv yard avg lead 850mtr | - | cu.m | 100 | - |
| 1.04 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 12.1.1 1.60 mm thick with zinc coating not less than 350 gram/m2 | - | Sq.m | 100 | - |
| 1.05 | Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde syntheticresin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminum primer on both sides & edges, including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodized aluminum (with 15 micron anodic coating) Tsections 35 x15x1.5 mm size main runners, cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer | - | Sq.m | 100 | - |
| 1.06 | Supply installation testing and commissioning of 36 W + (2 X 2) Feet LED surface or round Mounted light luminary fitting shape with minimum system lumen efficiacy of 100 lm/W with pressure Die cast Aluminium Heat sink and PF >0.5, THD <10%, CCT 5700 K , CRI 80. The LED with useful life of 50000 hrs at L70, seperate driver, heat sink, earthing provision. The input voltage range shall be 150 V to 270V. The fixture should have in-built Surge protection of 2 KV. The job includes AMC of lightening fixtures for a period of 2 years including replacement.Approved make :- Philips/GE/Crompton Greaves/Osram/Bajaj) | - | nos | 100 | - |
| 1.07 | Replacement of chain link fencing | - | Sq. m | 100 | - |
| 2220/132/33 KV Grid Sub station Udhampur | |||||
| 2.01 | DEMOLISGING OF PROTECTION AND FENCING WALL ALONG SIDE THE NATIONAL HIGHWAY AT 220/132/33KV GSS UDHAMPUR | - | - | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
Tendernotice_2.pdf
PDF • 0.95 MB
BOQ_1000390.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .