| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-Finance | L1 | Accepted-Finance lowest bidder | |
| 2 | L2₹34.5 L+₹2.7 L (8.35%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹39.9 L+₹8.1 L (25.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹47.2 L+₹15.3 L (48.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | airstack india L4 | HIRA SINGH AND SONS L2 | R B ENTERPRISES L1 | Rohan Construction Company L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified. | 600 | Cum | 55 ₹33,000 | 100 ₹60,000 | 109 ₹65,400 | 50 ₹30,000 Lowest |
| 2.00 | All as per the description of srl item No 1 above but exc 1.50m but not exc 3.00 mtr in depth. | 250 | Cum | 60 ₹15,000 Lowest | 105 ₹26,250 | 129 ₹32,250 | 99 ₹24,750 |
| 3.00 | M&L for concrete bed to drain pipe/sewage pipe of any dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete PCC 1:4 : 8 type D-2 (Using 40mm graded stone agg) including demolition complete all as specified. | 55 | Cum | 110 ₹6,050 Lowest | 550 ₹30,250 | 399 ₹21,945 | 444 ₹24,420 |
| 4.00 | M&L for 100mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | 155 | RM | 500 ₹77,500 | 250 ₹38,750 Lowest | 309 ₹47,895 | 299 ₹46,345 |
| 5.00 | M&L for 150mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortarv incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | 600 | RM | 540 ₹3,24,000 | 350 ₹2,10,000 Lowest | 409 ₹2,45,400 | 380 ₹2,28,000 |
| 6.00 | M&L for 200mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | 450 | RM | 600 ₹2,70,000 | 450 ₹2,02,500 Lowest | 629 ₹2,83,050 | 480 ₹2,16,000 |
| 7.00 | M&L for 300mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | 250 | RM | 640 ₹1,60,000 Lowest | 950 ₹2,37,500 | 849 ₹2,12,250 | 680 ₹1,70,000 |
| 8.00 | Cutting into existing manholes for connecting new drains, of 100 mm to 300 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified. | 50 | Each Job | 300 ₹15,000 | 50 ₹2,500 Lowest | 59 ₹2,950 | 150 ₹7,500 |
| 9.00 | Demolition of Concrete of any description and in any position not otherwise specifically provided for. | 10 | Cum | 200 ₹2,000 | 50 ₹500 | 49 ₹490 Lowest | 250 ₹2,500 |
| 10.00 | M&L for PCC 1:4:8, Type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete. | 5 | Cum | 3,000 ₹15,000 | 1,100 ₹5,500 | 599 ₹2,995 Lowest | 2,222 ₹11,110 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
7 May 2026, 6:00 pmClosed
GE North Delhi Cantt-10
GE North Delhi Cantt-10
REPAIR REPLACEMENT TO SEWAGE LINE PATH HARDSTANDING AND OTHER CONNECTED BR ITEMS UNDER THE AOR OF AGE BRI OF GE NORTH DELHI CANTT10
2026_MES_759701_1
GE/North-163/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE NORTH DELHI CANTT 10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT 10
₹98,000
Yes
29 Jun 2026
9 Apr 2026
9 May 2026
9 Apr 2026
7 May 2026
23 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches, in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified. | - | Cum | - | - |
| 2 | All as per the description of srl item No 1 above but exc 1.50m but not exc 3.00 mtr in depth. | - | Cum | - | - |
| 3 | M&L for concrete bed to drain pipe/sewage pipe of any dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete PCC 1:4 : 8 type D-2 (Using 40mm graded stone agg) including demolition complete all as specified. | - | Cum | - | - |
| 4 | M&L for 100mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | - | RM | - | - |
| 5 | M&L for 150mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortarv incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | - | RM | - | - |
| 6 | M&L for 200mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | - | RM | - | - |
| 7 | M&L for 300mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | - | RM | - | - |
| 8 | Cutting into existing manholes for connecting new drains, of 100 mm to 300 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified. | - | Each Job | - | - |
| 9 | Demolition of Concrete of any description and in any position not otherwise specifically provided for. | - | Cum | - | - |
| 10 | M&L for PCC 1:4:8, Type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete. | - | Cum | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_850917.xls
BOQ • 0.33 MB
Gen163.pdf
Tender Documents • 1.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .